Julien BLACHE
2db8ec7d98
Add the Epson Stylus DX-5050 (04b8:082b).
2007-07-31 11:48:49 +00:00
Julien BLACHE
ff5387ffa0
Apply patch from Nils Philippsen, turning 3 logical AND into bitwise AND (SANE bug #304363 ).
2007-07-30 13:42:39 +00:00
Julien BLACHE
964eccff2c
Add Epson Stylus DX-5000 (04b8:082b) based on several reports.
2007-07-30 13:36:52 +00:00
Julien BLACHE
ef05fcdbad
Add Epson Stylus DX4050 (04b8:082f) based on several reports.
2007-07-30 13:32:34 +00:00
Julien BLACHE
08f6df7b48
Add a RUN rule to the udev rules to automatically disable USB suspend for all known scanners.
...
This effectively works around the hardware bugs exposed by CONFIG_USB_SUSPEND.
Works only with kernels >= 2.6.22 where /sys/bus/usb/devices/*/power/level exists.
2007-07-29 18:39:54 +00:00
m. allan noah
86c976274a
update to backend v1.0.51, fix jpeg bug when using adf
2007-07-27 00:54:07 +00:00
Julien BLACHE
d5d762f96e
Revert my last commit and rework the one before to produce a backward compatible udev rules file. Yay.
2007-07-26 21:23:27 +00:00
Gerhard Jaeger
c9fbdd4073
* doc/plustek/Plustek-USB.changes: Update
...
* backend/plustek.c: Bumped build number
* backend/plustek-usbhw.c: Force output bit set on misc I/O,
when lamp is switched
* doc/descriptions/unsupported.desc: Updated some Plustek entries
2007-07-26 20:42:18 +00:00
Julien BLACHE
8dc1f4493c
Update udev rules for use with Linux >= 2.6.22 and CONFIG_USB_DEVICE_CLASS=n.
2007-07-25 09:21:18 +00:00
Wittawat Yamwong
c4af52e84a
Updated pixma backend to version 0.13.1
...
Added PIXMA MP960
2007-07-19 22:17:21 +00:00
m. allan noah
44e085b331
update website in manpage
2007-07-16 00:42:24 +00:00
m. allan noah
048161249d
* doc/descriptions/fujitsu.desc: update website and fi-60F status
...
* Authors, backend/dll.conf.in: added cardscan backend
2007-07-16 00:39:24 +00:00
m. allan noah
41761fede4
add new backend for Corex CardScan 800c, small-format sheetfed usb scanner
...
for cards/receipts, etc.
2007-07-15 01:46:47 +00:00
m. allan noah
5973ebe12d
add new models and fix bug in man page
...
drop sanei_thread.lo from libsane-fujitsu.la (fujitsu backend single threaded)
2007-07-15 00:59:14 +00:00
Gerhard Jaeger
aec768f551
* tools/check-usb-chip.c: Try to distinguish the various
...
GenesysLogic GeneScan ASICS - GL841, GL842 and GL843
2007-07-11 20:55:03 +00:00
m. allan noah
e343cc59cf
* backend/fujitsu.[ch], backend/fujitsu-scsi.h: update to v1.0.50,
...
add JPEG support, usb command sending and scan params cleanups
* include/sane/sane.h: add SANE_FRAME_JPEG
* frontend/scanimage.c: dont crash on unknown frame types
2007-07-10 16:07:25 +00:00
Gerhard Jaeger
05868435b9
* backend/plustek-usb.h backend/plustek-usbdevs.c backend/plustek.c:
...
Added flag to allow only 1- and 8-bit scanmodes. The Q-Scan does
not seem to support 14-bit modes.
2007-07-10 09:02:22 +00:00
Gerhard Jaeger
5b31b57a3a
doc/descriptions/plustek.desc: Fixed web entries
2007-07-10 06:19:10 +00:00
Gerhard Jaeger
b0778e41a9
* backend/plustek-usb*.[ch] backend/plustek.[ch]:
...
Added sheetfed device Q-Scan USB001 from Portable Peripherals
Fixed Mustek Bearpaw and made some speedup (bugreports #304343 and
#301763 )
Fixed calibration for senororders other that RGB
* doc/descriptions/plustek.desc: Bumped version and added Q-Scan
* doc/descriptions/unsupported.desc: Removed Q-Scan
* doc/sane-plustek.man doc/plustek/Plustek-USB.changes: Update
2007-06-29 08:40:33 +00:00
m. allan noah
26d0e072ee
update to v 1.0.49. add fi-5750C and S510
2007-06-28 17:53:09 +00:00
Julien BLACHE
5dcf165795
Switch sanei_scsi to the SG_IO ioctl interface, instead of the
...
asynchronous SG3 read/write interface.
Makes it possible to use SCSI scanners in 32/64bit mixed environments,
thanks to the ioctl 32bit compatibility layer, which is NOT possible
using the SG3 interface.
2007-06-21 19:35:53 +00:00
Gerhard Jaeger
dd7aa7403b
* doc/plustek/Plustek-PARPORT.changes: Update.
...
* backend/plustek_pp.c: Bumped build number.
* backend/plustek-pp_drv.c backend/plustek_pp_sysdep.h:
Make the Kernelmodule work with Kernels > 2.6.15 w/o DEVFS
2007-06-18 20:29:45 +00:00
Ilia Sotnikov
9f6424d266
+ Use libtool instead of ar/ranlib, which correctly handles dependencies
...
(eg. for parallel makes)
2007-06-12 06:40:29 +00:00
Mattias Ellert
a75a509bcc
Updated localization files
2007-05-08 11:46:24 +00:00
Ilia Sotnikov
18160038f1
* backend/hp5590_low.c: don't use libusb structs directly, define
...
necessary of them by ourselves ('struct usb_ctrl_setup' -> 'struct
usb_in_usb_ctrl_setup')
* backend/hp5590_low.c: renamed 'struct usb_bulk_setup' to 'struct
usb_in_usb_bulk_setup' to show its internal usage
2007-04-29 15:08:43 +00:00
Troy Rollo
23862a0072
Add ChangeLog entry for recent changed to the HP3500 backend.
2007-04-24 23:29:43 +00:00
Ilia Sotnikov
19ac33fc60
*** empty log message ***
2007-04-24 18:18:11 +00:00
Mattias Ellert
78ff28cb83
Adding new external backend hp5590
2007-04-21 16:17:56 +00:00
Julien BLACHE
d1d46d8d2a
Remove bogus check in get_identity2_information().
2007-04-21 10:12:48 +00:00
m. allan noah
ae29b20e4b
simple whitespace change to see if cvs changes survived gforge cron scripts
2007-04-19 14:01:29 +00:00
Julien BLACHE
a0fd0edb03
Use mode 0664 for usbfs device nodes; allows everybody on the system to use lsusb.
2007-04-17 19:21:13 +00:00
Julien BLACHE
83a22d6ab9
backend/microtek2.c: Add missing braces.
2007-04-17 19:11:29 +00:00
m. allan noah
e00626d917
whitespace change to test sane-commit list
2007-04-17 00:51:14 +00:00
m. allan noah
9eeb345e6a
update to v1.0.48
2007-04-16 23:54:27 +00:00
Wittawat Yamwong
efced87595
Remove Canon PIXMA MP160 & MP600 from unsupported. (supported by pixma)
2007-04-14 23:32:40 +00:00
Mattias Ellert
833ae68aca
Moved 3 scanners from unsupported to hp3900
2007-04-13 20:17:05 +00:00
m. allan noah
9e506f4cfc
update backend to v1.0.47
2007-04-13 15:49:08 +00:00
Wittawat Yamwong
459d5c7e8e
* Updated to version 0.13.0
...
* Added MP160, MP180, MP460, MP510 and MP600
* Fixed a buffer-overflow bug in sane_read()
2007-04-09 20:41:25 +00:00
Jochen Eisinger
d620d407bb
2007-04-5 Jochen Eisinger <jochen@penguin-breeder.org>
...
* README.openbsd, tools/README, tools/openbsd/attach,
tools/openbsd/detach: add notes about device permissions on
OpenBSD and provide some example scripts for hotplugd(8).
2007-04-05 07:41:02 +00:00
m. allan noah
ed0e4af3d5
fix SANE_Parameters description
2007-04-02 19:07:46 +00:00
Julien BLACHE
7691b81b51
Remove leftovers from a previous experiment.
2007-03-21 16:10:29 +00:00
Julien BLACHE
17ca143dc2
Adding hal FDI output mode, from David Zeuthen <davidz@redhat.com>
2007-03-18 09:31:10 +00:00
Oliver Rauch
5b38d6f1d6
*** empty log message ***
2007-03-17 15:51:54 +00:00
Earle F. Philhower III
c5c85c5515
Added lineart and halftone scan modes, updated man page with new options
2007-03-08 21:49:23 +00:00
Gerhard Jaeger
b851bf539a
* doc/plustek/Plustek-USB.changes: Update.
...
* backend/plustek.c: Bumped build number.
* backend/plustek-usb.c: Fixed typo.
* backend/plustek-usbdevs.c: Added CanoScan to all Canon
device strings, identified one more Plustek device as U24.
* backend/plustek-usbhw.c: Fixed button handling for Plustek/
KYE devices and added some more debug messages.
2007-03-05 19:50:32 +00:00
Giuseppe Sacco
1436f82ab6
Corrected a few typo in previous translation
2007-02-24 09:54:00 +00:00
Giuseppe Sacco
b6b3beea4b
Italian translation update
2007-02-24 09:16:51 +00:00
Jochen Eisinger
78e9962f4b
2007-02-11 Jochen Eisinger <jochen@penguin-breeder.org>
...
* doc/sane-mustek_pp.man: clean up markup, bug #304392
2007-02-11 17:36:31 +00:00
Henning Geinitz
218a1080d0
Polish translation fix (from Jakub Bogusz <qboosh at pld-linux.org>, bug #304410 ).
2007-02-11 13:19:35 +00:00
Gerhard Jaeger
3766614f83
* sanei/sanei_scsi.c: Fixed retrieval of HZ.
2007-02-07 07:16:53 +00:00
Henning Geinitz
1a0fe6ab1a
Added UMAX Astra 2850. Added Canon Imagerunner series.
2007-01-28 16:31:53 +00:00
Henning Geinitz
e8a59a97df
Added UMAX Astra 2850.
2007-01-28 15:58:09 +00:00
Henning Geinitz
5c7517ed50
Added .conf entry for Pluste OpticPro S12 and S24. Updated .desc file.
2007-01-28 15:41:18 +00:00
m. allan noah
4ed45d56e4
updated to backend version 1.0.45
2007-01-28 15:20:04 +00:00
Oliver Rauch
1b9030b925
*** empty log message ***
2007-01-27 22:07:40 +00:00
m. allan noah
4eabb3820c
updated to backend version 1.0.44, updated maintainer email addy
2007-01-27 01:42:13 +00:00
Jochen Eisinger
50a260fee3
2006-01-21 Jochen Eisinger <jochen@penguin-breeder.org>
...
* doc/descriptions/mustek_pp.desc: Cybercom is a CIS scanner
2007-01-21 21:51:00 +00:00
Mattias Ellert
17e9115fdd
Fixed the "three-valued boolean" bug
2007-01-21 13:29:21 +00:00
Mattias Ellert
448ba7e84d
Changelog entries
2007-01-20 23:21:54 +00:00
Alessandro Zummo
7a34d599e5
* sanei/sanei_tcp.c: added a missing include
...
* backend/epson2.c: fixed a bug while moving scanner data,
removed support for line mode (block or ext modes will be used).
2007-01-20 20:59:05 +00:00
Mattias Ellert
c2df6b9677
Fix autogenerated files
2007-01-20 09:55:10 +00:00
Mattias Ellert
cc8acd0d7e
Adding Visioneer Strobe Pro USB to unsupported
2007-01-19 14:52:14 +00:00
Henning Geinitz
6beb33d016
Added and updated several scanners.
2007-01-15 23:14:06 +00:00
Julien BLACHE
7d15d5b06b
Add missing return status check in sane_start(), preventing an ugly segfault later on.
2007-01-08 18:45:50 +00:00
Julien BLACHE
aae12092de
Fix man warnings.
2007-01-08 18:40:30 +00:00
Alessandro Zummo
bf5a1290f7
* epson2: restructured code once more, splitted
...
in multiple files, added networking
support, added FS G extended handshaking mode,
make proper use of extended commands when possible
* sanei/sanei_tcp.c: read now wait until all
the requested data is available.
2006-12-18 00:13:09 +00:00
Alessandro Zummo
99770af682
coolscan2: fixed coolscan2 infrared to work
...
as advertised in the man page. RGBA format will come soon.
2006-12-13 22:46:24 +00:00
Alessandro Zummo
35d54905e8
epson2: removed calls to alloca(), code reorganization fixed a bug
...
with request_extended_status (reply length is 33 on older scanners).
include/.cvsignore: added two more entries
2006-12-12 01:12:07 +00:00
Pierre Willenbrock
6a7fb3235a
* backend/genesys_devices.c: reduced height of calibration area
...
* backend/genesys_gl841.c: fixed bug in offset calibration(offset values were
not clamped to 0..255)
2006-12-10 14:06:18 +00:00
Ulrich Deiters
b06eb2220b
Ulrich Deiters: disentangled some pointer arithmetics in canon-sane.c
2006-12-10 12:28:42 +00:00
Alessandro Zummo
48b02b3489
epson2: reordered includes, replaced __FUNCTION__, use the new byteorder macros
...
moved acbyteorder.m4 to m4/byteorder.m4, added m4/stdint.m4
2006-12-07 19:28:02 +00:00
Alessandro Zummo
326e3c131c
Added acbyteorder.m4 macro for endianness conversion
2006-12-06 20:37:00 +00:00
Pierre Willenbrock
dba2f29195
* backend/genesys_devices.c: fixed gamma settings(1.0 now)
...
* backend/genesys.c backend/genesys_gl841.c: improved calibration for dark
shades
2006-12-02 21:57:08 +00:00
Alessandro Zummo
735130b0ff
Added missing bits for epson2 driver.
2006-12-02 14:47:21 +00:00
Alessandro Zummo
57e12f246a
fixed spelling. :)
2006-11-30 23:47:57 +00:00
Alessandro Zummo
b1db719d88
Added (esperimental) epson2 driver.
2006-11-30 23:46:23 +00:00
Alessandro Zummo
b400664851
2006-12-01 Alessandro Zummo <a.zummo@towertech.it>
...
* Added sanei_tcp interface.
2006-11-30 23:23:19 +00:00
Henning Geinitz
cfc1f96ba8
SCX-4200 is reported to work.
2006-11-27 19:49:06 +00:00
Gerhard Jaeger
06323b4597
* doc/plustek/Plustek-USB.changes: update.
...
* backend/plustek.c: bumped build number, fixed option
descriptors, see bug #303786 .
2006-11-22 20:30:32 +00:00
Henning Geinitz
f3f6ce01a7
Updated status of Brother MFC-7420.
2006-11-22 20:19:05 +00:00
Henning Geinitz
db352cc1b7
Updated status of UMAX 2000.
2006-11-22 20:17:30 +00:00
Henning Geinitz
b8b81f00d5
Added several scanners, fixed the USB id for Microtek 4850 (bug #304151 ).
2006-11-22 20:16:09 +00:00
m. allan noah
5e81563b60
updated external desc
2006-11-06 13:55:50 +00:00
Henning Geinitz
3f8864e7e7
Project is unmaintained.
2006-10-31 19:26:26 +00:00
Henning Geinitz
9b46fe372c
Added HP Photosmart C5100 and ScanJet 8390.
2006-10-31 19:22:19 +00:00
Henning Geinitz
8cd0f282a9
Added Canon Canoscan 4400F, LiDE 70, Corex Cardscan 700 C, Umax Astra 4900,
...
Visioneer Onetouch 7700. Updated other scanners.
2006-10-24 20:53:47 +00:00
Henning Geinitz
c04d8433d5
Updated based on sane-devel information.
2006-10-24 20:50:22 +00:00
Henning Geinitz
a39c0a4620
Updated (from Jonathan Bravo Lopez <jkdsoft at gmail.com>).
2006-10-24 20:47:13 +00:00
Henning Geinitz
c8d597168f
Major bugfix and few small changes (noticed by Jaroslaw Gorny) (bug #303962 ).
2006-10-24 20:12:51 +00:00
Henning Geinitz
2df19bcd0b
Added Support for Genius Colorpage SF600.
2006-10-03 21:24:39 +00:00
Henning Geinitz
a0b7aed86d
Added EDT BizCardReader 900C. Moved Genius ColorPage-SF600 to gt68xx.desc. Minor
...
updates.
2006-10-03 21:19:31 +00:00
Henning Geinitz
6bff1fdf4b
Added examples on how to set the scan area in the manual page (bug
...
#303802 ). Mention how to separate parameters from options in --help and manpage
(bug #303819 ).
2006-10-03 18:39:35 +00:00
Henning Geinitz
316075f0c4
Changed status of HP Scanjet 4370 to "minimal" (bug #303839 ).
2006-10-03 17:57:56 +00:00
Giuseppe Sacco
12e964d64f
Italian translation update
2006-09-24 11:32:45 +00:00
m. allan noah
2eb55005c6
update to v1.0.43
2006-09-19 12:04:54 +00:00
Stéphane Voltz
63fa40d277
- fixed color calibration for 1220P, whit is really white, no more
...
greenish tint
- mail address update
2006-09-18 04:59:52 +00:00
Henning Geinitz
276cf032ee
Updated Polish translation (from Jakub Bogusz, bug #303769 ).
2006-09-14 18:47:20 +00:00
Henning Geinitz
69914baf00
Added several scanners.
2006-09-14 18:14:13 +00:00
Oliver Schwartz
00e6616499
Bugfix for firmware download by Paul Smedley
2006-09-03 10:00:11 +00:00
m. allan noah
3a78258ac5
update to v1.0.42
2006-09-01 00:31:45 +00:00