Oliver Schwartz
cb8f353952
Added 16 bit option for Epson scanners (untested)
2005-09-28 21:33:11 +00:00
Julien BLACHE
92fa96f61c
tools/udev/convert-usermap.sh: Don't print 0x when matching VID and PID.
2005-09-28 21:06:10 +00:00
Julien BLACHE
7ed2585674
tools/udev/convert-usermap.sh: Added a script to convert hotplug/libsane.usermap to a udev rules file. udev 070 + linux 2.6.14 will deprecate hotplug.
...
tools/README: updated.
2005-09-28 20:37:43 +00:00
Henning Geinitz
0ba5bee76d
Added link to genesys homepage.
2005-09-28 19:32:22 +00:00
Henning Geinitz
78d9dfe426
Removed duplicate entry.
2005-09-28 19:24:25 +00:00
Henning Geinitz
259a745dd4
Print more clear output if no USB scanners are found. Point to manual page. Warn
...
if libusb support hasn't been built.
2005-09-26 12:13:51 +00:00
Henning Geinitz
d60289794e
Added external lexmark backend. Moved Lexmark X11?? devices to
...
lexmark.desc. Based on patch from Fred Odendaal <freshshelf@rogers.com>.
2005-09-25 12:01:25 +00:00
Oliver Schwartz
13c07cf87d
Removed debugging code for Epson scanners
2005-09-25 08:19:12 +00:00
Henning Geinitz
b27183004c
Ignore EBUSY from usb_set_configuration. This function fails, if a different
...
interface of the same device is claimed (e.g. by usblp).
2005-09-23 12:52:35 +00:00
Henning Geinitz
e3e00e9d91
Added progress indicator to scanimage (based on patch from Mario Goppold
...
<mgoppold@tbz-pariv.de>). Updated copyright information, added links to
sane-devel mailing list.
2005-09-23 12:05:51 +00:00
Henning Geinitz
f59a22e563
Added warning message that's printed when libusb or its header file is not
...
available.
2005-09-23 10:54:16 +00:00
Henning Geinitz
c3a9d77397
Mention in addition to the listed libraries, their header files are also
...
neccessary. A missing usb.h is a common problem when building SANE (--> no USB
support).
2005-09-23 10:51:41 +00:00
Mattias Ellert
21f94b0264
Fix SANE_DEBUG_SANEI_PV8630
2005-09-22 19:02:25 +00:00
Frank Zago
111fe1fedd
*** empty log message ***
2005-09-19 20:00:13 +00:00
Henning Geinitz
2428065ee4
Added Canon PIXMA MP750.
2005-09-18 11:16:53 +00:00
Henning Geinitz
ac100ab017
Mustek Paragon 600 II EP works. Mentioned "parport0".
2005-09-18 11:11:46 +00:00
Henning Geinitz
78bbdb61fd
Added some hints about number of files.
2005-09-18 10:53:30 +00:00
Henning Geinitz
872c187d42
Fixed segfault that may happen with Mustek ScanExpress A3 USB.
2005-09-18 10:48:18 +00:00
Mattias Ellert
e4e7e71db6
New date for good libusb from CVS
2005-09-17 04:48:55 +00:00
Mattias Ellert
007bd9e9f6
Fix disabling of locking when locking group does not exist
2005-09-07 16:50:02 +00:00
Henning Geinitz
ee26d224ec
Added Genius ColorPage Slim 1200.
2005-09-07 15:54:57 +00:00
Oliver Schirrmeister
d79d95d0aa
bugfixes for the M3092, enabled dropoutcolor for all fi-* scanners.
...
Tested with the fi-5650
2005-09-07 11:44:45 +00:00
Henning Geinitz
f3d0b6f763
Updated Russian translation (from Vitaly Lipatov <LAV@vl3143.spb.edu>).
2005-09-05 20:02:53 +00:00
Oliver Schwartz
304b667a6a
Fixed debugging code for epson scanners
2005-09-03 10:52:11 +00:00
Henning Geinitz
e790e335e8
Added HP PSC 750.
2005-09-02 19:06:11 +00:00
Henning Geinitz
8b797c6eb6
Added Epson Perfection 4490 Photo.
2005-09-02 18:52:18 +00:00
Henning Geinitz
149b4c3923
Added detection for SQ113 chip (e.g. Mustek BearPaw 2448 TA Pro).
2005-09-01 20:41:12 +00:00
Henning Geinitz
aa209997b7
Genius ColorPage Vivid 1200 X is reported to work. Genius ColorPage Vivid 4 XE
...
seems to be the same as 4 X, it just doesn't have buttons. Cleanup of .desc
file. Fixed gain setting. Mustek ScanExpress A3 USB 600 dpi color scanning works
now.
2005-09-01 20:01:50 +00:00
Henning Geinitz
5c4b3d9a0e
Mustek BearPaw 2448 TA Pro has status "good" now.
2005-08-31 20:45:53 +00:00
Henning Geinitz
e401121ef1
Removed Mustek 1800 A3 Pro (this is actually a P3600 A3 Pro).
2005-08-31 20:44:47 +00:00
Henning Geinitz
e80ac97c60
New external Backend for Mustek BearPaw 2448 TA Pro.
2005-08-30 20:22:27 +00:00
Henning Geinitz
1c9f419660
Removed Mustek BearPaw 2448 TA Pro (now supported by external Mustek USB2
...
backend). Added comments about that backend to some other scanners that may be
supported later.
2005-08-30 20:21:26 +00:00
Henning Geinitz
e51df58fc8
Canon LiDE 60 is GL841 based.
2005-08-29 16:43:43 +00:00
Henning Geinitz
8f789e594c
Changed status of Canon 636u too "good".
2005-08-28 14:37:33 +00:00
Henning Geinitz
f191ed670d
Brother MFC-5440CN is reported to work (bug #302105 ).
2005-08-27 11:06:57 +00:00
Stéphane Voltz
8c463cfb76
- added EPP support for UMAX Astra 610P
2005-08-24 05:35:06 +00:00
Henning Geinitz
492e322adf
Added Canon LiDE 60. Reflecta Digitdia 3600 is not GL841-based.
2005-08-23 16:30:28 +00:00
Stéphane Voltz
f9f48fafa4
- Added rts8858c (used by lexmark X1100 series) detection
2005-08-22 18:59:26 +00:00
Henning Geinitz
d202ddbe93
Mention problems with library names.
2005-08-22 17:18:26 +00:00
Henning Geinitz
821ca4d53c
Added some Genius scanners. Fixed Visioneer Onetouch 7300 USB. Added Plustek
...
OpticSlim 2400.
2005-08-22 15:48:48 +00:00
Gerhard Jaeger
e65d96c5b0
* doc/plustek/Plustek-USB.changes: Update.
...
* backend/plustek.c: Bumped build number.
* backend/plustek-usb.c backend/plustek-usbscan.c: Fixed problem,
when trying to scan at resolutions beyond the optical one
(sensor stops too early).
* tools/hotplug/libsane.usermap: Added USB ID for LiDE25.
2005-08-22 07:29:14 +00:00
Henning Geinitz
dc9efdd920
Marked microtek2 backend as unsupported. Changed link to point to old website
...
directly. Listed Microtek ScanMaker 9800XL as supported (bug #301515 ).
2005-08-21 14:41:54 +00:00
Mattias Ellert
dcec1b5385
Updated from libtool 1.5.18.
2005-08-21 08:12:42 +00:00
Henning Geinitz
93d43e0be8
Increased number limit of scanners that can work with this backend to 50. Added
...
support for Genius ColorPage Vivid 1200 X (untested).
2005-08-20 17:54:34 +00:00
Henning Geinitz
46be471fd0
Disabled link to backend homepage which doesn't seem to contain anything
...
sane-related.
2005-08-19 15:59:01 +00:00
Henning Geinitz
3c38ba02f4
Enabled GT68XX_FLAG_NO_STOP for Mustek BearPaw 2400 CU Plus. Some of these
...
scanners don't seem to like that command.
2005-08-19 15:54:31 +00:00
Henning Geinitz
e50187fb8f
Fixed check for usbcalls.h on OS/2 (patch from Paul Smedley <paul@smedley.info>).
2005-08-19 15:26:50 +00:00
Gerhard Jaeger
269fd05fb2
* doc/plustek/Plustek-USB.changes: Update.
...
* backend/plustek-usb.h backend/plustek-usbdevs.c: Removed obsolete
_WAF_BLACKFINE. LiDE20 does not seem to have a reliable black
calibration area, so the devices now will switch off the lamp
for dark calibration.
* backend/plustek-usbcal.c backend/plustek-usbscan.c: Cleanup.
* backend/plustek-usbshading.c: Fixed line statistics and added
calibration data output.
* backend/plustek.c: Bumped build number.
2005-08-19 11:56:52 +00:00
Henning Geinitz
b19e6c5262
Fixed the problem concerning scanning on *BSD. Scanning only worked once (bug
...
#300597 ). Fixed compilation warnings.
2005-08-18 19:26:09 +00:00
Henning Geinitz
9f9339fd92
Min. libusb version is 0.1.8.
2005-08-17 18:01:37 +00:00
Julien BLACHE
94ad270193
Added USB IDs for the sm3600-supported scanners. If you know the exact model name corresponding to the above IDs, please mail sane-devel:
...
0x05da/0x40b3, 0x05da/0x40b8, 0x05da/0x40ca, 0x05da/0x40dd, 0x05da/0x40ff
2005-08-17 16:36:49 +00:00
Henning Geinitz
621dc84b90
Added check for Toshiba M011 chips as used in Microtek ScanMaker 3600, 3700, and
...
3750.
2005-08-16 20:28:46 +00:00
Oliver Schwartz
0f98b4adfe
Removed C++-style comment
2005-08-16 20:15:10 +00:00
Henning Geinitz
a2f1183de1
Removed direct dependence of sm3600 on libusb. Used sanei_usb instead. Based on
...
patch from Francois Revol <revol@free.fr>. Updated documentation
accordingly. Fixed compilation warnings.
2005-08-16 19:50:34 +00:00
Henning Geinitz
ee11f5abcf
Added check for combination of a PowerVision PV8630 (USB->parport bridge) and
...
National Semiconductor LM9830 as used in the HP 4200. Fixed compilation warning.
2005-08-16 18:23:42 +00:00
Henning Geinitz
53fe9ae549
Don't print anything else but the found messages in "-q" mode.
2005-08-16 18:19:41 +00:00
Oliver Schwartz
159782bd7f
Make compileable again
2005-08-16 17:19:20 +00:00
Henning Geinitz
921f7d7cbc
Added Canon PIXMA MP780 and Lexmark P6250.
2005-08-16 09:32:21 +00:00
Oliver Schwartz
7f9b7c4646
Added temporary debug code for 2480/2580 distinction
2005-08-15 18:56:55 +00:00
Oliver Schwartz
59fc80c118
Added support for Epson 3490/3590 (thanks to Matt Judge)
2005-08-15 18:06:38 +00:00
Gerhard Jaeger
a4a88fccbf
* doc/plustek/Plustek-USB.changes: Update.
...
* doc/descriptions/plustek.desc: Updated version number.
* backend/plustek.h. backend/plustek-usb.h backend/plustek-usbcalfile.c
backend/plustek-usbimg.c backend/plustek-usbmap.c
backend/plustek-usbdevs.c backend/plustek-usbscan.c: Cleanup.
* backend/plustek.c: Bumped version and build number.
Activated IPC between reader-process and parent.
* backend/plustek-usbio.c: usbio_DetectLM983x() now returns error if
register could not be red, usbio_ResetLM983x() checks for reg7
value before writing.
* backend/plustek-usbhw.c: Added button support for Plustek/Genius
devices. Changed behaviour of usb_IsScannerReady().
Added special misc I/O setup for CIS devices (usb_ResetRegisters).
* backend/plustek-usb.c: Minor fix for startup reset.
Removed unnecessary calls to usbio_ResetLM983x().
* backend/plustek-usbshading.c: Readded kCIS670 to add 5% extra to
LiDE20 fine calibration.
* backend/plustek-usbcal.c: Tried to use the settings from SANE-1.0.13.
Added _TWEAK_GAIN to allow increasing GAIN during lamp coarse
calibration. Added call to speedtest function.
2005-08-15 15:02:22 +00:00
Henning Geinitz
3ae9b03454
Don't exit with error when trying to set inactive options. This especially
...
happens in connection with geometry options and the v4l backend (bugs #300321 ,
#301977 ).
2005-08-14 14:51:06 +00:00
Henning Geinitz
46cfa92d35
Enabled backtracking by default. This is slower but avois bumping the scan head
...
at the end of the scan area and also missing parts of the scanned
image. Increased safety margin for backtracking. This fixes the "garbled image"
bug. Set default gamma value to 2. Manpage update. Status set to "basic".
2005-08-14 12:59:32 +00:00
Henning Geinitz
dccf9e2fa2
Added Changelog-1.0.16 to DISTFILES.
2005-08-14 08:22:32 +00:00
Henning Geinitz
2ce6d33e26
Moved CPPFLAGS definition down to avoid problems with libtool tests for -fPIC.
2005-08-13 16:02:50 +00:00
Henning Geinitz
78a02e266b
Removed (backend is now included).
2005-08-13 15:32:12 +00:00
Henning Geinitz
3c5ea794ba
Added hp4200 backend. Code from Julien BLACHE's sane-backends-extras debian
...
package, based on Frank Zago's patches based on Adrian Perez Jorge's code. Fixed
compilation warnings. Fixed bug when no sane device was given. Code indented by
indent -gnu. Added man page.
2005-08-13 15:30:02 +00:00
Henning Geinitz
6953fd4e2c
Removed ":new".
2005-08-13 15:18:48 +00:00
Gerhard Jaeger
3a4c35c470
* backend/plustek_pp.c: Bumped build number.
...
* backend/plustek_pp-genericio.c: Fixed bug, that causes ASIC96003/1
based devices to move their sensors too fast in lineart mode at
200 and 300dpi.
* doc/plustek/Plustek-PARPORT.changes: Update.
2005-08-10 20:41:09 +00:00
Henning Geinitz
784791758e
Added Hewlett-Packard Scanjet 4370.
2005-08-09 17:16:32 +00:00
Henning Geinitz
4b2d240870
Minor fixes for usbcalls interface (patch from Paul Smedley <paul@smedley.info>).
2005-08-09 16:28:38 +00:00
Gerhard Jaeger
4877fb0d98
* acinclude.m4 configure: Locking feature will be disabled on OS/2
...
per default (according to Paul Smedley <paul@smedley.info>).
* doc/plustek/Plustek-USB.changes: Update.
* backend/plustek.c: Bumped build number.
* doc/plustek/Plustek-USB.txt doc/descriptions/plustek.desc
doc/sane-plustek.man backend/plustek-usb.c backend/plustek-usbdevs.c:
Added support for CanoScan LiDE25.
2005-08-08 07:43:14 +00:00
Henning Geinitz
b29ea31da2
Fixed some compilation warnings.
2005-08-07 15:53:03 +00:00
Henning Geinitz
2d224c4a75
Added support for usb functionality on OS/2 using the usbcalls interface (patch
...
from Paul Smedley <paul@smedley.info>).
2005-08-07 14:26:33 +00:00
Henning Geinitz
5cd850ee6a
Updated from libtool 1.5.18.
2005-08-07 13:03:32 +00:00
Oliver Schwartz
f283eedc6b
Corrected date in ChangeLog
2005-08-07 12:38:33 +00:00
Oliver Schwartz
417ef8eac5
Use first known device if no device is specified
2005-08-07 12:37:29 +00:00
Henning Geinitz
1ee59e30eb
Typo fix.
2005-08-07 12:32:37 +00:00
Henning Geinitz
92b8f5e33f
Updated version. Enabled compilation warnings.
2005-08-07 12:08:07 +00:00
Henning Geinitz
26a01ae380
****** Release of sane-backends 1.0.16. End of code freeze ******
2005-08-07 10:05:21 +00:00
Henning Geinitz
34a5bc2fb8
New version 1.0.16.
2005-08-07 10:04:34 +00:00
Stéphane Voltz
9857b4cf6c
- fixed endianess issue in genesys backend when creating
...
slope table
2005-08-05 12:18:35 +00:00
Henning Geinitz
bf897c3502
Updated Danish translation (from Mogens Jaeger <mogensjaeger@get2net.dk).
2005-08-02 17:21:34 +00:00
Mattias Ellert
3758711bdb
Update Swedish translation.
2005-08-02 15:09:21 +00:00
Eddy De Greef
2fd060fe23
Updated URL for additional CIS driver info.
2005-08-01 19:14:50 +00:00
Henning Geinitz
5c255ba9e0
Updated.
2005-07-31 15:44:13 +00:00
Henning Geinitz
292d5db30a
---- CODE FREEZE FOR SANE 1.0.16 ---
2005-07-31 15:38:28 +00:00
Henning Geinitz
a1a5e6de83
Disabled compilation warnings.
2005-07-31 15:37:53 +00:00
Karl Heinz Kremer
4c4a945d1b
Applied Olaf Meuwissen's patch to add new device IDs.
2005-07-30 16:52:28 +00:00
Henning Geinitz
4fcd19f065
Avoid error messages in locking test. Make sure that io/cam/cam.h header file
...
will be detected correctly.
2005-07-30 16:39:00 +00:00
Henning Geinitz
443cfa28bb
libsane and documentation is installed correctly again.
2005-07-30 14:15:50 +00:00
Henning Geinitz
faf4c8c57e
Added Xerox Workcentre 470cx. Added link for Canon DR-2080C.
2005-07-30 13:42:46 +00:00
Gerard Klaver
acd978ec7e
Update teco2.c .h sane-teco2.man teco2.desc teco2.txt
2005-07-29 20:44:12 +00:00
Julien BLACHE
51cc4e0797
Added various Epson IDs from Olaf Meeuwissen; reodered some misplaced Epson entries.
2005-07-29 10:15:00 +00:00
Julien BLACHE
051d5c0d3a
Added Visioneer OneTouch 7300 (0x0444,0x0211), from Derek J Frye.
2005-07-29 10:03:50 +00:00
Gerhard Jaeger
ea61868394
* doc/descriptions-external/epkowa.desc: Updated according to
...
the info provided by Olaf Meeuwissen <olaf.meeuwissen@avasys.jp>
2005-07-25 09:12:30 +00:00
Henning Geinitz
9c81b97d4a
Added unsupported scanners from hp_rts88xx.desc. Removed HP ScanJet 3770 (now in
...
hp3770 backend). Added Lexmark X75 PrinTrio.
2005-07-24 21:01:52 +00:00
Henning Geinitz
e137eecca5
Added external hp3770 and hp8200 backends.
2005-07-24 20:59:21 +00:00
Henning Geinitz
cd7606938a
Moved unsupported devices to unsupported.desc.
2005-07-24 20:57:45 +00:00
Henning Geinitz
b5089cfd10
Brother DCP 7025 is reported to work (bug #301960 ).
2005-07-24 20:56:37 +00:00
Giuseppe Sacco
10ab7e64db
italian translation update
2005-07-22 09:10:41 +00:00
Julien BLACHE
06972e5d57
Added HP ScanJet 7400C (0x03f0, 0x0801).
2005-07-22 07:25:25 +00:00
Henning Geinitz
aaf3c69627
Testing commit messages.
2005-07-21 18:02:41 +00:00
Henning Geinitz
67eb059c49
Testing commit mails.
2005-07-21 17:55:50 +00:00
Henning Geinitz
e74185c76b
Testing commit messages.
2005-07-21 17:50:13 +00:00
Gerhard Jaeger
547c0bb0a7
* doc/plustek/Plustek-USB.changes: Update.
...
* backend/plustek.c: Bumped build number.
* backend/plustek-usbcal.c: Fixed lampsettings for CIS devices.
2005-07-21 10:01:18 +00:00
Oliver Schwartz
74190c064c
Changed TPO scanning area for 2480/2580, reenabled 2400 DPI for 2480/2580
2005-07-20 21:37:29 +00:00
Oliver Schwartz
260f7d83eb
ZETA changes for SnapScan backend
2005-07-18 17:37:37 +00:00
Henning Geinitz
1276d174e7
---- FEATURE FREEZE FOR SANE 1.0.16 ---
2005-07-17 18:32:44 +00:00
Henning Geinitz
2342c2c6f2
Updated.
2005-07-17 18:31:43 +00:00
Henning Geinitz
00e9b16d58
Removed "const" to make gcc on OS/2 happy.
2005-07-17 16:18:34 +00:00
Henning Geinitz
9cf32060ac
Make sure that all the necessary files will be in the distribution .tar.gz file.
2005-07-17 12:27:59 +00:00
Henning Geinitz
6c3427c52d
Changes to support SANE on ZETA. Not all
...
patches have been applied yet, but it's a start. The backends
are not installed as shared libs but as add-ons, which are shared libs
but in a specific folder in [/system|~]/config/add-ons/ named SANE/.
The install target has been changed to account for this,
Some files don't exist in BeOS/ZETA (ipc.h, ...).
Bbackend function names get a prefix, I suppose to avoid namespace clashes.
Though we do have a libdl to implement dl_open, the native way is prefered.
Added a --with-docdir= configure arg.
BeOS has a broken get[name|addr]info() from bind. This is fixed in ZETA R1.
libtool needs -no-undefined. Various VPATH fixes.
Check for <be/drivers/USB_scanner.h>, but not used yet.
No S_IFSOCK (sockets are fds to /dev/net/api). Stub pio code, untested.
Patch from Francois Revol <revol@free.fr>.
2005-07-15 21:59:25 +00:00
Henning Geinitz
2dd4b1822c
Fixed comment (we still use 30 seconds USB timeout by default).
2005-07-15 18:16:35 +00:00
Henning Geinitz
e479c32503
Better 4->8 bit depth expansion algorithm (from Mattias Ellert
...
<mattias.ellert@tsl.uu.se>).
2005-07-15 18:12:49 +00:00
Oliver Schwartz
74ff64ae24
Updated descriptions for Epson 1670, 2480 and 2580
2005-07-15 17:43:39 +00:00
Rene Rebe
e5a5f45497
Updated the Avision backend with the latest off-site maintained version:
...
fixed segmentation faults for some modes, many many new devices, two
different duplex modes are supported, vast speedup of multi page batch scans,
buttons as well a 7-segment LED readout and some quirks for old scanners not
filling all fields
2005-07-15 09:12:27 +00:00
Rene Rebe
e5193fdcae
Added support to set the USB timeout.
2005-07-15 09:02:02 +00:00
Henning Geinitz
38cc925c4b
Changed resolution from 75 to 100 dpi and changed 16 bit/color to 12 based on a
...
user report for the Visioneer OneTouch 7300. Updated .desc. Moved check for
stable lamp to its own function. Mustek ScanExpress A3 USB: Use CIS
calibration. Use lamp warmup. Fixed CCD on GT6801 scanning (color scanning was
broken due to a change in motormode_2.
2005-07-10 20:58:58 +00:00
Henning Geinitz
56e3295552
Make sure that getopt is not built on OS/2 (from Franz Bakan <fbakan@gmx.net>).
2005-07-09 13:19:51 +00:00
Henning Geinitz
1cfaf7a3ce
Updated Danish translation (from Mogens Jaeger <mogensjaeger@get2net.dk>). Made
...
sure that no errors occur because xgettext/xmsgfmt think that "%" is a C format
string. Regenerated all po files.
2005-07-09 12:58:20 +00:00
Frank Zago
e3aceaf492
*** empty log message ***
2005-07-07 11:57:27 +00:00
Gerhard Jaeger
ae92358fed
* doc/plustek/Plustek-USB.changes: Update.
...
* backend/plustek.c: Fixed scanarea calculation.
* backend/plustek-usbshading.c: Fixed fine-white calibration.
2005-07-07 09:59:26 +00:00
Gerhard Jaeger
5b97232b43
* doc/descriptions-external/epkowa.desc: Updated according to
...
the info provided by Olaf Meeuwissen <olaf.meeuwissen@avasys.jp>
2005-07-05 06:46:14 +00:00
Gerhard Jaeger
0a91e0b533
* backend/plustek.[ch] backend/plustek-usbscan.c
...
backend/plustek-usbshading.c backend/plustek-usbdevs.c
backend/plustek-usbdevs.c backend/plustek-usbimg.c
backend/plustek-usbmap.c backend/plustek-usbhw.c
backend/plustek-usbcal.c backend/plustek-usb.[ch]:
Added button support, did some cleanup, added IPC between
reader- and parent-process.
2005-07-04 09:55:01 +00:00
Ulrich Deiters
a97d0bf43c
inserted definition for SSIZE_MAX
2005-07-04 07:01:53 +00:00
Henning Geinitz
161a58ace0
Updated for sane-backends 1.0.16.
2005-07-03 16:12:10 +00:00
Henning Geinitz
3db60263e8
Typo/formatting fixes.
2005-07-03 13:58:21 +00:00
Henning Geinitz
9932061d41
Removed. Scanners have been moved to doc/descriptions/genesys.desc and
...
doc/descriptions/unsupported.desc.
2005-07-03 13:50:45 +00:00
Henning Geinitz
74cd84acb5
Added links to scanners with GL646 and GL841 chipsets. Moved all unsupported
...
scanners from doc/descriptions-external/genesys.desc to unsupported.desc. Minor
fixes for other scanners.
2005-07-03 13:46:52 +00:00
Henning Geinitz
cb0ed1be00
Used "Medion/Lifetec/Tevion/Cytron" as manufacturer as in the other
...
backends. Used "ScanJet 2300C" as model name as in other backends.
2005-07-03 13:40:08 +00:00
Henning Geinitz
e9f761d067
Don't check the result of usb_find_busses(). Based on patch from Julien BLACHE
...
<jb@jblache.org>.
2005-07-03 13:35:48 +00:00
Ulrich Deiters
20aff8e022
restored actual version of the Canon-SCSI backend
2005-07-01 19:21:55 +00:00
Stéphane Voltz
8f102afe79
- fixed missing modifications for genesys backend inclusion
2005-06-30 19:46:06 +00:00
Gerhard Jaeger
68a968ecd3
* tools/RenSaneDlls.cmd backend/dll.c: Fixed OS/2 restriction for
...
dlopening DLLs on OS/2, as it only works for 7.3 filenames for
some reason (patches by Franz Bakan <fbakan@gmx.net>
2005-06-30 08:19:06 +00:00
Gerhard Jaeger
38e6ad0adb
* backend/plustek.c: Fixed "double free" problem in sane_exit.
...
* doc/plustek/Plustek-USB.changes: Update.
2005-06-27 07:09:15 +00:00
Mattias Ellert
a21fe44c4f
sane-desc needs $(LIBLIB)
2005-06-26 09:56:24 +00:00
Henning Geinitz
67b85ddb0d
Added "Ethernet" to list of possible interfaces.
2005-06-19 16:08:34 +00:00
Henning Geinitz
8cd6e6533f
Added several models, updated others.
2005-06-19 16:04:20 +00:00
Henning Geinitz
dbbc9e7820
Removed misleading comment.
2005-06-19 15:59:52 +00:00
Henning Geinitz
61409cb5bd
Removed Samsung SCX-4216F (supported by samsung backend). Dell 1600n has also
...
network connection.
2005-06-19 15:56:23 +00:00
Henning Geinitz
d4b441310f
Added Canon CanoScan LiDE 500F.
2005-06-12 14:57:46 +00:00
Henning Geinitz
7dda4a0306
Fixed comments.
2005-06-04 13:45:26 +00:00
Henning Geinitz
04e085c532
New. Listed scanners supported by the new external brother2 backend.
2005-06-04 13:43:03 +00:00
Henning Geinitz
6de5708e4f
Added Genius ColorPage-SF600.
2005-06-04 13:33:13 +00:00
Karl Heinz Kremer
a245023c10
Added CX-4600 to desc file.
2005-05-31 01:14:55 +00:00
Henning Geinitz
6fd1ee367e
Start exposure with the settings from the scanner entry. CIS
...
Calibration and exposure uses a broader spectrum now. Expsoure
limit is increased to 50 loops. Genius Vivid 4x is reported to
work so the UNTESTED label is removed now. Visioneer 7300 is
reported to work so the UNTESTED label is removed now. Genius
ColorPage Vivid 1200XE: Removed UNTESTED label. Fixed
resolutions. Adjusted margins. Fixed color order. Fixed
linedistance. Adjusted AFE. Mustek ScanExpress 1248 UB: Fixed
margins. Adjusted AFE. Adjusted exposure. Adjusted
gamma. Changed status to "complete". Mustek BearPaw 2400 CU
Plus: Adsusted exposure and AFE parameters. Hopefully stripes
and similar trouble are gone now. Mustek BearPaw 1200 CU:
Increased exposure to avoid vertical lines. Updated manual page.
2005-05-29 19:58:56 +00:00
Henning Geinitz
ceaa2ddade
Updated, mostly concerning kernel scanner driver (deprecated). Minor fixes.
2005-05-29 19:55:15 +00:00
Henning Geinitz
95be6202fa
Status of Samsung SCX-4100 is "good" asit's reported to work.
2005-05-29 19:52:39 +00:00
Henning Geinitz
350c73aba3
Fixed missing link for Genius ColorPage-Slim 1200 USB2.
2005-05-28 18:56:25 +00:00
Henning Geinitz
e75fa70160
Added Avision DS310F. Added link for the UMAX Astra 4000.
2005-05-28 18:42:07 +00:00
Henning Geinitz
03e378e10b
Mention RPC codes explicitely and explain what request and reply means. based on
...
patch from Johannes Berg <johannes@sipsolutions.net>.
2005-05-26 14:28:01 +00:00
Henning Geinitz
c63843df35
Mention RPC codes explicitely and explain what request and reply means. based on
...
patch from Johannes Berg <johannes@sipsolutions.net>.
2005-05-26 09:30:47 +00:00
Jochen Eisinger
66ff43083a
2005-05-25 Jochen Eisinger <jochen@penguin-breeder.org>
...
* doc/descriptions/mustek_pp.desc: added scanner
2005-05-25 13:24:03 +00:00
Julien BLACHE
2917422aa2
doc/sane-find-scanner.man, doc/gamma4scanimage.man: spelling fixes from A Costa.
2005-05-23 16:44:44 +00:00
Henning Geinitz
ebd956bcae
Changed status of Medion MD 6471 to "basic". Removed comment about not-existing
...
backend.
2005-05-22 13:41:49 +00:00
Henning Geinitz
cfb5d0856a
Added Konica Minolta Dimage 5400 2. Fixed bus type for Mustek 800 II EP.
2005-05-22 13:38:34 +00:00
Oliver Schwartz
649853f7e1
Disabled 2400 DPI for Epson 2480
2005-05-22 11:50:24 +00:00
Henning Geinitz
1b1eb09205
Regenerated translation files. Updated German translation.
2005-05-20 17:31:07 +00:00
Henning Geinitz
7d0d083b8d
Mustek BearPaw 1200 CU Plus model 0x21b works now. Fixed firmware and offset
...
settings. Calibration is not completely ok yet, however. Code cleanup for
setup_scan (only one function for all chipsets). Simplified line mode/pixel
mode setting Updated TODO. Mustek BearPaw 2448 TA Plus is now only "basic". Too
much trouble for "good". Removed option "fast preview". By default for preview
mode 8 bits/pixel are used. Fixed indentation. Full scan really scans from y=0
on gt6816 scanners now.
2005-05-20 17:21:56 +00:00
Henning Geinitz
e659b95cc0
Added Kodak i30 and Minolta Dual Scan IV. Updated link to Konica Minolta website.
2005-05-16 13:06:05 +00:00
Henning Geinitz
31b676a0f5
Minor updates and line-wrap fixes.
2005-05-16 13:03:18 +00:00
Frank Zago
6e2052d795
*** empty log message ***
2005-05-15 19:38:56 +00:00
Julien BLACHE
e93887d425
libsane.usermap: Added Epson Stylus RX620 (04b8/0811). From Mike Talbot.
2005-05-13 11:00:26 +00:00
Gerhard Jaeger
c411be9bd6
* backend/plustek-pp_misc.c: Applied patch (see bug #301605 ).
...
* doc/plustek/Plustek-PARPORT.changes: Update.
* backend/plustek-pp.c: Bumped build number.
2005-05-11 14:46:39 +00:00
Gerhard Jaeger
b13a55e34c
* sanei/sanei_access.c: Added PATH_MAX, in case it's
...
not defined by any header (i.e. OS/2).
2005-05-10 06:51:57 +00:00
Mattias Ellert
6219f5471c
Readme update
2005-05-07 19:08:56 +00:00
Henning Geinitz
ea9ad9a396
Plustek OpticSlim 2400: Fixed list of resolutions. That fixed the
...
preview. Removed "untested" warning. Adjusted scan area. Updated gt68xx.TODO.
Find firmwares independent of capitalization (bug #301580 ).
2005-05-07 17:16:30 +00:00
Julien BLACHE
155790c61d
libsane.usermap: Added Microtek ScanMaker 3700 (05da/40cb). From Ian Beckwith.
2005-05-07 09:18:09 +00:00
Gerard Klaver
c33139cc82
- indent -gnu
...
- free (devlist) added so memory allocated by sane_get_devices() will be released (bugreport 300128)
- added more DEBUG lines and some small fixes.
2005-05-06 21:12:21 +00:00
Henning Geinitz
b3669f8d6e
Added options to set the time after which the lamp of the A3 Pro is shut off
...
and to shut it off immediately.
2005-05-05 17:28:38 +00:00
Henning Geinitz
2cba59f874
Added Dell 922.
2005-05-05 15:53:22 +00:00
Peter Fales
88df3af0bb
When no port is specified in the gphoto2.conf config file, an attempt
...
was being made to strdup() a bad pointer.
2005-05-05 03:52:03 +00:00
Henning Geinitz
486e6b24a9
Fixed link.
2005-04-29 18:22:11 +00:00
Henning Geinitz
3d75c6a2bd
Added ScanPartner 600C (bug #301528 ).
2005-04-29 17:22:43 +00:00
Julien BLACHE
390e9b4884
backend/v4l.c: duplicate capability.name in attach() so that each device is listed with its actual name, not with the name of the last discovered device. Reported by Andreas Hartmann.
2005-04-28 21:18:41 +00:00
Mattias Ellert
23b39a25f1
Missing braces
2005-04-28 12:49:01 +00:00
Gerhard Jaeger
3f893c5e03
* doc/descriptions/plustek.desc: Added UMAX Astranet ia101.
2005-04-27 07:35:10 +00:00
Julien BLACHE
32f60c3e82
Added Epson Stylus CX3650 (04b8/080e).
2005-04-26 11:30:22 +00:00
Gerhard Jaeger
a838a5886c
* include/sane/sanei_pp.h, sanei/sanei_pp.c: Added outb_eppdata
...
functionality (thanks to Anderson Lizardo).
* backend/plustek-pp_procs.h, backend/plustek-pp_io.c,
backend/plustek-pp_misc.c: Fixed compilation problem for kernel
module with gcc-3.4 compiler.
* doc/plustek/Plustek-PARPORT.changes: Update.
* backend/plustek-pp.c: Bumped build number.
2005-04-25 09:53:43 +00:00
Henning Geinitz
e57dff602e
Marked Kazuya Fukuda as active.
2005-04-24 10:47:17 +00:00
Henning Geinitz
a76c30cfd0
Added Canon PIXMA MP110.
2005-04-24 10:44:11 +00:00
Henning Geinitz
790d3bcc90
Added Primax Colorado 2200 USB.
2005-04-24 10:42:08 +00:00
Henning Geinitz
0003d79b8e
Added Mustek TwainScan II SP (bug #301217 ).
2005-04-24 10:34:52 +00:00
Henning Geinitz
99402cb85b
Fixed Minolta Scan Dual III entry (bug #301512 ).
2005-04-24 10:19:10 +00:00
Julien BLACHE
2f4b6644c9
Add an FAQ section to the LICENSE file.
2005-04-23 18:16:18 +00:00
Julien BLACHE
ddf8fb6874
Added Genius ColorPage Vivid3xe (0458/2017), from Ramiro Aceves through Debian BTS.
2005-04-23 15:51:18 +00:00
Gerhard Jaeger
e605d0bd27
* doc/plustek/Plustek-USB.changes: Update.
...
* backend/plustek.c: Bumped build number.
2005-04-18 07:50:25 +00:00
Gerhard Jaeger
5c3bb8a294
* backend/plustek-usbhw.c, backend/plustek-usbscan.c: Fixed
...
problem, that has been reported in conjunction with backtracking
and sensor-speedup option.
2005-04-18 07:33:29 +00:00
Henning Geinitz
64c2b9df30
Added and updated several scanners.
2005-04-17 21:36:47 +00:00
Gerard Klaver
9ae13c1e70
-update sanei/sanei_usb.c
...
-update include/sanei_usb.h
-update frontend/scanimage.c
-update doc/scanimage.man
2005-04-15 21:36:51 +00:00
Mattias Ellert
de7ed8a4eb
Add missing SANE_I18N, Regenerate .po files accordingly, Update Swedish translations
2005-04-13 12:50:08 +00:00
Mattias Ellert
ec08c32e02
Man page fixes
2005-04-12 06:01:14 +00:00
Gerhard Jaeger
156b2f1923
* acinclude.m4, configure.in, configure: the locking feature will
...
now be disabled, when the selected group could not be set.
The configuration script should not fail any longer.
2005-04-11 07:49:54 +00:00
Julien BLACHE
5c9ba87bb1
hp5400: make non-SANE-standard functions static.
2005-04-10 12:20:50 +00:00
Jochen Eisinger
ecdbf48171
2005-04-10 Jochen Eisinger <jochen@penguin-breeder.org>
...
* backend/mustek_pp.c, backend/mustek_pp.conf, sanei/sanei_pa4s2.c,
include/sane/sanei_pa4s2.h, doc/sane-mustek_pp.man: added global
option "no_epp" to work around a known bug in the linux parport
code.
2005-04-10 11:53:16 +00:00
Julien BLACHE
457cbd6cd2
doc/sane.man: another typo fix from A Costa.
2005-04-02 10:16:11 +00:00
Gerhard Jaeger
1ed8917ee6
* README: Added some info about the --enable-locking switch.
2005-04-01 14:26:26 +00:00
Gerhard Jaeger
d8c607e6b9
* tools/hotplug/libsane.usermap: Added some Plustek devices.
...
* mkinstalldirs: Added -o and -g options for changing the
owner and group of an installed directory.
* acinclude.m4, configure.in, configure: Added --enable-locking
and --with-group to enable device locking via sanei_access-lib
and to specify the group of the locking directory.
* include/sane/config.h.in: ENABLE_LOCKING has been added
by automake/autoconf.
* backend/Makefile.in: Added installation of
$(localstatesanedir)/lock/sane, were the lockfile should go to.
Also added linking of sanei_access to the plustek backend.
* include/Makefile.in: Added sane/sanei_access.h.
* sanei/Makefile.in: Added sanei_access.c.
* include/sane/sanei_access.h sanei/sanei_access.h: Initial checkin.
2005-04-01 14:05:25 +00:00
Gerhard Jaeger
77c59b49d0
* doc/descriptions/unsupported.desc
...
doc/descriptions-external/genesys.desc: Moved some Plustek
devices over to the genesys descriptions.
2005-04-01 08:05:47 +00:00
Julien BLACHE
ede7cccaec
Fix typos in scanimage.man, patch from A Costa.
2005-03-31 11:12:18 +00:00
Earle F. Philhower III
02e0cf229e
Fix endianness problems in gray mode
2005-03-22 04:35:43 +00:00
Gerard Klaver
300349a7ed
added samsung.desc
2005-03-17 13:48:16 +00:00
Henning Geinitz
204e51eb70
Removed Microtek ScanMaker 4800 (supported by sm3840 now).
2005-03-16 18:13:27 +00:00
Earle F. Philhower III
e1da48acae
SM3840: Added SM4800, PPC endianness fix, Makefile deps fix
2005-03-16 08:09:19 +00:00
Henning Geinitz
b2852924f2
Added and updated various scanners.
2005-03-13 17:48:27 +00:00
Gerard Klaver
2af1a79792
update sane-teco2.man (text) and teco2.c (use of __unused__)
2005-03-04 19:57:25 +00:00
Julien BLACHE
13f51314cb
Add missing quotes in the grep line.
2005-03-03 13:47:39 +00:00
Julien BLACHE
207c751982
tools/hotplug-ng/libsane.hotplug: allow for several spaces between fields in the db file.
2005-03-02 21:23:59 +00:00
Julien BLACHE
44c5b6e6d4
Replace \t with [[:space:]] when greeping for the device in the db file.
2005-02-28 12:51:56 +00:00
Julien BLACHE
309228e9db
Added new hotplug/hotplug-ng hook with scripts and documentation.
2005-02-21 21:00:57 +00:00
Henning Geinitz
98f01c7975
Removed (backend included in SANE).
2005-02-20 20:18:30 +00:00
Henning Geinitz
76f6d02fdb
Removed (backend included in SANE).
2005-02-20 20:14:40 +00:00
Henning Geinitz
46d59a14aa
Removed Genius ColorPage-Vivid Pro II, now in external backend. Added Visioneer
...
9000.
2005-02-20 19:09:24 +00:00
Gerhard Jaeger
907ba41091
doc/decriptions-external: Added new external backend geniusvp2.
...
Fixed KHKs log entry: 2995-02-10 :)))))
2005-02-14 07:54:53 +00:00
Karl Heinz Kremer
1c6f3c7dde
Added configuration information for GT-6500 (fix for bug #301100 )
2005-02-11 01:01:56 +00:00
Karl Heinz Kremer
7ab0f24737
Added CX-3600 and 3650 to epson.desc.
2005-02-11 00:53:30 +00:00
Oliver Schwartz
79672dfb5b
Added IDs for Benq 5250C and 5000S
2005-02-08 22:17:53 +00:00
Gerhard Jaeger
0855e0a008
* sanei/sanei_pp.c: Cleanup, uses now static array for
...
parport management instead of dynamically allocated.
Fixes at least a potential memory leak.
2005-02-08 11:32:57 +00:00
Oliver Schwartz
0791d7494a
Renamed 'Benq' to 'Benq (Acer)' in desc files
2005-02-06 18:00:41 +00:00
Henning Geinitz
df67487415
Added Polish translation (from Jerzy Szczudlowski <jerzy-guest@users.alioth.debian.org>).
...
See bug #301054 .
2005-02-06 17:35:00 +00:00
Henning Geinitz
5872d567fc
Updated status.
2005-02-06 16:58:54 +00:00
Henning Geinitz
36a7051f52
Added new external backend sm3840.
2005-02-06 16:52:59 +00:00
Henning Geinitz
3ba4918baf
Added several scanners. Minor fixes.
2005-02-06 16:33:42 +00:00
Gerhard Jaeger
8c5371dc50
* tools/hotplug/libsane.usermap: Added Epson CX6600 based on patch
...
submitted by Aurelien Jarno <lists@aurel32.net>.
2005-02-04 07:57:47 +00:00
Ullrich Sigwanz
3e7028d23b
added ID for Silitek-HP-ScanJet-3400c-Clone
2005-02-03 18:48:42 +00:00
Oliver Rauch
133b172756
coolscan.c: added initialization dev->scanning = SANE_FALSE
2005-01-19 21:59:35 +00:00
Oliver Schwartz
e50a436ce0
Added ID for Benq 5250C
2005-01-18 20:36:13 +00:00
Henning Geinitz
b06269e68f
Fixed some macros (patch from esr@thyrsus.com).
2005-01-16 18:00:01 +00:00
Henning Geinitz
a11bdc452e
Added ColorPage-Vivid Pro II.
2005-01-16 17:38:22 +00:00
Karl Heinz Kremer
b978e39044
Added RX-425
2005-01-16 16:44:06 +00:00
Henning Geinitz
a97e4510b2
Added Trust SCSI Scan 19200 -Excellence Series-.
2005-01-16 16:42:51 +00:00
Karl Heinz Kremer
ba3e39794f
Added IDs for RX-425 (from bug report #301114 )
2005-01-16 16:37:11 +00:00
Henning Geinitz
cc24365c6e
Added Epson Stylus RX425 based on bug report #301114 .
2005-01-16 16:29:25 +00:00
Henning Geinitz
cf5ab73b93
Added UMAX Astraslim 6000.
2005-01-16 16:23:27 +00:00
Henning Geinitz
825d4ec752
Added several scanners and updated the status of others based on user comments.
2005-01-12 19:51:27 +00:00
Julien BLACHE
c0b5478ad2
Credit Ubuntu and Martin Pitt for the change to libusbscanner.
2005-01-12 16:48:35 +00:00
Julien BLACHE
bc3f82ea44
tools/hotplug/libusbscanner: Use sysfs to determine the device number instead of guessing
2005-01-12 16:47:27 +00:00
Gerhard Jaeger
9a8d652e89
* doc/plustek/Plustek-USB.changes: Update.
...
* backend/plustek.c: Bumped build number. Copyright Update.
* backend/plustek-usbscan.c backend/plustek-usbshading.c:
Using now PhyDpi.y as selector for the motor MCLK setting.
Copyright Update.
* backend/plustek-usbdevs.c:
Tweaked motor settings for EPSON and CANON1200.
Copyright Update.
* backend/plustek-*.[ch]: Copyright Update.
2005-01-12 11:39:46 +00:00
Henning Geinitz
5fc132b67d
Added Guillemot scanner.
2005-01-10 19:36:11 +00:00
Karl Heinz Kremer
86bc7cfc04
Added SCSI version of GT-5000 to supported list.
2005-01-09 23:12:53 +00:00
Karl Heinz Kremer
bc91d375dc
"flaming hack to get USB scanners working without timeouts under linux"
...
submitted by "Steve" (in comment to bug #300830 )
2005-01-09 15:33:56 +00:00
Julien BLACHE
ed5831c99f
tools/sane-find-scanner: Added a hint about switching the scanner on and connecting it to the computer before doing anything else.
2004-12-29 15:39:12 +00:00
Gerard Klaver
d369be08dd
update /doc/descriptions/backends-external/hpaio.desc and stv680.desc
2004-12-26 19:44:12 +00:00
Henning Geinitz
9d7eae7d02
Added several scanners.
2004-12-26 16:13:14 +00:00
Karl Heinz Kremer
634e4a9210
Added USB IDs for CX-4600 and CX-3650.
2004-12-18 15:15:15 +00:00
Gerard Klaver
adfe3b8a2c
info new external backend
2004-12-15 15:18:48 +00:00
Oliver Schwartz
c94edf0864
Added quality calibration for Epson 2480 (by Simon Munton)
2004-12-09 23:21:48 +00:00
Henning Geinitz
b1b75afd4a
Disabled stop_scan command for Mustek BearPaw 2448 TA Plus.
2004-12-07 19:32:13 +00:00
Henning Geinitz
fab4c4d951
Added Benq 320p.
2004-12-05 18:15:50 +00:00