The backend description comes from the epkowa.desc file
with appropriate changes to suit epson2.desc. The usb
device list is now generated from this file, skipping
the :unsupported models. This means epson2 now detects
32 more models.
- use average instead of min/max for fine offset and gain
- rewrite supported resolution list as x and y arrays
- merge x and y resolution options into single option
- move scan params into two new structs, s->u and s->s
- sane_get_parameters() just returns values from s->u
- dont call wait_scanner() in object_position()
- dont call ssm_*() from option handler
- refactor sane_start()
- read_from_buffer() can workaround missing res, modes and cropping
- set most DR-2xxx machines to use the read_from_buffer workarounds
- set default threshold to 90
- add option for button #3 of some machines
- don't eject paper during init
- add DR-2010 quirks
- switch counter to HARD_SELECT, not SOFT
- Updated the list of supported devices (HP 5500C which is similar to
4570C, 5500C which is similar to 4500C) - only strings/comments, no
code was changed
- Updated backend version
- Updated man page
- Updated backend version
- Added HP ScanJet 4500C as completely supported
- Added HP ScanJet 5500C as untested
- HP ScanJet 4570C/5550C/5590/7650 marked as completely supported
* configure, configure.in: version 1.0.21cvs
* doc/releases.txt: minor updates for new build system
* doc/descriptions/canon_dr.desc, doc/descriptions/coolscan3.desc,
doc/descriptions/rts8891.desc, doc/descriptions/xerox_mfp.desc:
remove :new tag
with newer automake.
* backend/Makefile.am, tools/sane-config.in: Add missing
$GPHOTO2_LDFLAGS so library can be found.
* tools/Makefile.am: Add mising $SCSI_LIBS to sane-find-scanner.
doc/descriptions/fujitsu.desc: add S1500 usb ids and status
* backend/canon_dr.c: update credits
* doc/sane-fujitsu.man doc/sane-canon_dr.man: update version numbers,
dates, credits and known issues
* doc/saned.man: remove section about uncontrolled data port range
- return cmd status for reads of sensor options
* backend/canon_dr.c, doc/descriptions/canon_dr.desc: backend v26
- return cmd status for reads of sensor options
- allow rs to adjust read length for all bad status responses
- fix DR-2510C duplex deinterlacing code
- rewrite sane_read helpers to read until EOF
- update sane_start for scanners that dont use object_position
- dont call sanei_usb_clear_halt() if device is not open
- increase default buffer size to 4 megs
- set buffermode on by default
- hide modes and resolutions that DR-2510C lies about
- read_panel() logs front-end access to sensors instead of timing
- rewrite do_usb_cmd() to use remainder from RS info
* doc/desciptions/canon_dr.desc: backend v24, update DR-2510C comment
- rewrite all image data processing code
- handle more image interlacing formats
- re-enable binary mode on some scanners
- limit some machines to full-width scanning
* doc/desciptions/canon_dr.desc: v23, improved comments
- pad gray deinterlacing area for DR-2510C
- override tl_x and br_x for fixed width scanners
* doc/descriptions/canon_dr.desc: backend v19, update comments
- add byte-oriented duplex interlace code
- add RRGGBB color interlace code
- add basic support for DR-2580C, DR-2050C, DR-2080C, DR-2510C
- add more unknown setwindow bits
- add support for 16 byte status packets
- clean do_usb_cmd error handling (call reset more often)
- set status packet size from config file
- rewrite config file parsing to reset options after each scanner
- add config options for vendor, model, version
- dont call inquiry if those 3 options are set
- remove default config file from code
- add initial gray deinterlacing code for DR-2510C
- rename do_usb_reset to do_usb_clear
* doc/descriptions/canon_dr.desc: backend v18, update model status
* backend/canon_dr.conf.in: added better comments and new options
to sane-config missed during fix to stop using LIBS to link everything.
Add back in code to move LDFLAGS out of $GPHOTO2_LIBS and into
GPHOTO2_LDFLAGS.
issues, by Mattias Ellert.
* backend/fujitsu.c: backend v89, fi-4750 has no serial number support
* doc/descriptions/fujitsu.desc: backend v89, remove 'MAC/TWAIN' text
* doc/sane-fujitsu.man: backend v89
* backend/.cvsignore: ignore *.loT
Add tools/openbsd to distribution package.
* include/Makefile.am: include files should have been installed
under sane/ directory when converted to automake.
* doc/Makefile.am: Cleanup. Use automake's built in support to
install docs within subdirectories.
doc/Makefile to use automake. Main difference is that
no longer installs man pages for backends that are not
compiled. Moved install ownership of $top_srcdir docs
to $top_srcdir's Makefile.
* doc/descriptions/epjitsu.desc, doc/descriptions/fujitsu.desc: version
* doc/descriptions/umax1220u.desc: correct status of 1600U
* doc/descriptions/xerox_mfp.desc: status = new
Updated backends with EXTRA_* files to allow Makefile's
to always pass in BACKEND_NAME to be fixed to backend name
instead of filename; while still making sure that
SANE_DEBUG_${BACKEND}* exist as documented in man pages.
Add references to epson and epson2 man pages about
SANE_DEBUG_EPSONx_SCSI and _NET options.
Created an epson2 man page; based mostly on epson page.
Fix a few bugs with "all" and "uninstall" targets to work when
$(builddir) != $(srcdir). Added $(DESTDIR) to uninstall target.
Made $(distdir) related to current directory to match automake.
- round pixels_per_line down to arbitrary limits for fi-4990 & fi-4860
- fi-4860 returns random garbage to serial number queries
- initialize *info to 0 in sane_control_option()
* doc/descriptions/fujitsu.desc: backend v85, improve status/comments
* frontend/scanimage.c: initialize *info, fix buffer overwalk
- add all documented request sense codes to sense_handler()
- fix color jpeg (remove unneeded BGR to RGB swapping code)
- add macros for LUT data
* backend/canon_dr.conf.in: add DR-2080C usb ID
* doc/descriptions/canon_dr.desc: backend v10, add DR 3020
- rename read/send_counter to read/send_panel
- enable control panel during init
- add options for all buttons
- call TUR twice in wait_scanner(), even if first succeeds
- disable rif
- enable brightness/contrast/threshold options
* doc/descriptions/canon_dr.desc, doc/sane-canon_dr.man: backend v8
- jpeg support (size rounding and header overwrite)
- call object_position(load) between pages even if buffering is on
- use request sense info bytes on short scsi reads
- byte swap color BGR to RGB
- round image width down, not up
- round image height down to even # of lines
- always transfer even # of lines per block
- scsi and jpeg don't require reading extra lines to reach EOF
- rename buffer option to buffermode to avoid conflict with scanimage
- send ssm_do and ssm_df during sane_start
- improve sense_handler output
* doc/descriptions/canon_dr.desc: backend v7
doc/descriptions/canon_dr.desc: backend v5
- remove EOF ejection code
- add SSM and GSM commands
- add dropout, doublefeed, and jpeg compression options
- disable adf backside
- fix adf duplex
- read two extra lines (ignore errors) at end of image
- only send scan command at beginning of batch
- fix bug in hexdump with 0 length string
- DR-7580 support
backend/fujitsu.[ch], backend/fujitsu-scsi.h: backend v79
- add usb ids for several models
- print additional hardware capability bits
- detect front-side endorser
- disable endorser-side controls if only one side installed
- add quirks for fi-6x70
* backend/epjitsu.[ch], backend/epjitsu-cmd.h: backend v 13, 14 and 15:
- add working page-height control
- add working brightness, contrast and threshold controls
- add disabled threshold curve and geometry controls
- move initialization code to sane_get_devices, for hotplugging
- support S300 on USB power
- support S300 225x200 and 600x600 scans
- support for automatic paper length detection (parm.lines = -1)
- expose hardware buttons/sensors as options for S300
* doc/descriptions/epjitsu.desc: change S300 status to good
- add independent maximum area values for flatbed
- override said values for fi-4220C, fi-4220C2 and fi-5220C
* doc/descriptions/fujitsu.desc: bump version, add 2 untested scanners
- add fi-6130 usb ID
- correct overscan dimension calculation
- provide correct overscan size overrides for fi-5110C and fi-4x20C2
- fi-5750C can't handle 10 bit LUT via USB
- add halftone type and pattern options
- support M3097G with IPC and CMP options via modified VPD response
* doc/descriptions/fujitsu.desc, doc/sane-fujitsu.man: backend v68,
- manpage cleanup
use model and serial to build sane.name (idea from Ryan Duryea),
allow both serial_name and device_name to sane_open scanner,
simulate missing VPD data for M3097G, probe scanner for color
interlacing mode instead of hardcoding, other minor cleanups
doc/descriptions/hp3900.desc, doc/descriptions/hp5590.desc,
doc/descriptions/hpljm1005.desc, doc/descriptions/hs2p.desc:
remove 'new' tag from sane 1.0.19 backends
* doc/descriptions/fujitsu.desc, backend/fujitsu.conf.in:
add fi-5530C2 usb ID
* backend/cardscan.c: correct version number
* backend/epjitsu.conf.in: improved firmware directions
* backend/fujitsu.[ch]: update to backend v 1.0.61
- page code 32 is not color interlacing, rename to 'unknown'
- increase number of bytes in response buffer of init_ms()
- protect debug modification code in init_ms() if NDEBUG is set
- proper async sane_cancel support
- re-enable JPEG support
- replace s->img_count with s->side
- sane_get_parameters(): dont round up larger than current paper size
- sane_start() rewritten, shorter, more clear
- return values are SANE_Status, not int
- hide unused functions
Reorganize code by splitting the main() function into a series of functions.
Factorize common code between the old network code and the AF-indep code. There's now only one version of main().
- added: Pixma MP210, MP470, MP520, MP610
- added: MultiPASS MP710
- declared untested: MP140, MP220, MultiPASS MP740
- declared experimental and untested: MP970
Bugs and fixes
- multipage documents scan no more fails with non-ADF MPs
- IO Fail bug when scanning large pages e.g. with Xsane
- implement send_time message form MP710, MP730 family
- run indent -gnu on all pixma_* source files.