Wykres commitów

1212 Commity (9f9339fd92a21b331c008b121dd0015d2a5474db)

Autor SHA1 Wiadomość Data
Ullrich Sigwanz 281726a0b2 adding monochrome modes 2004-10-07 22:37:08 +00:00
Gerhard Jaeger 3095319e39 Update. 2004-10-06 13:20:51 +00:00
Henning Geinitz 9f77cad58d Added link to artiscan 9600 project. Removed Genius ColorPage-EP. 2004-10-06 10:42:06 +00:00
Henning Geinitz 5d3abf887c New version: 0.96. Added Genius ColorPage-EP (from Karsten Festag
<karsten.festag@gmx.de>).
2004-10-06 10:36:57 +00:00
Henning Geinitz 85b457a282 sane-find-scanner can now load USB descriptors from /proc/bus/usb/devices dumps
(e.g. from the unsupported scanner web pages). Minor modifications to some of
the chipset tests.
2004-10-04 18:29:37 +00:00
Gerhard Jaeger b73080d6f8 Update. 2004-10-04 07:19:30 +00:00
Henning Geinitz a70f09e4ca Check for (size_t) -1 doesn't work on 64 bit platforms as size_t is 64 bits
there while the length of a data block is defined as 32 bits in the SANE network
standard (bug #300837).
2004-10-03 12:34:10 +00:00
Henning Geinitz 0379607466 Added Nikon LS-5000 ED. 2004-10-03 10:16:10 +00:00
Henning Geinitz f5aaa34eed Updates of supported scanners. 2004-10-02 16:21:37 +00:00
Henning Geinitz 38076118db Added several scanners. Removed Genius Vivid 1200 XE (actually supported by
gt68xx backend).
2004-10-02 15:56:16 +00:00
Oliver Rauch 47aa22cd1b *** empty log message *** 2004-09-30 22:20:28 +00:00
Oliver Schwartz 7e10ea5e46 Changed entry for Epson 2580 2004-09-27 18:51:49 +00:00
Gerhard Jaeger 7032ca30c1 Fixed Plustek entries. 2004-09-21 07:18:43 +00:00
Henning Geinitz 39f44b08c0 Added Compeye Simplex 1236C. 2004-09-19 15:25:22 +00:00
Gerhard Jaeger 0eea1cde70 Update. 2004-09-08 07:29:25 +00:00
Gerhard Jaeger caf65a14bf Added Microtek Scanmaker 5700,
ArtixScan 4000tf and Medion MD41985.
2004-09-08 07:29:00 +00:00
Henning Geinitz 1eddd0c6a5 Moved HP 35xx series to unsupported.desc because these scanners use a RTS8801
chip (no Genesys chipset).
2004-09-06 21:28:21 +00:00
Henning Geinitz 42aab25d25 Fixed firmware name for Mustek 1248 UB. Changed status to basic. Removed
"unsupported" warning.  Added workaround for shared memory compilation problem
on Windows. It's now possible to add a new vendor/product id line to gt68xx.conf
to test yet unsupported scanners without changing the source code.
2004-09-03 14:06:19 +00:00
Henning Geinitz 99ee355d03 Added Canon LiDE 35. 2004-09-03 11:37:52 +00:00
Henning Geinitz 8b7ddfd8a6 Added Lexmark X1130, Dell 1600n. Removed Canon LiDE 35 (now in genesys.desc) and
Epson Perfection 2480 (now in snapscan.desc).
2004-09-03 11:37:07 +00:00
Oliver Schwartz 199eab31b8 Added support for Epson 2480 2004-09-02 20:59:12 +00:00
Ullrich Sigwanz d6badf6687 removed niash_types.h 2004-08-31 18:43:58 +00:00
Ullrich Sigwanz 17dd1149b9 added warning about kernel version 2004-08-31 18:42:15 +00:00
Gerhard Jaeger 42dee92d8c Corrected LiDE35 name. 2004-08-30 12:16:08 +00:00
Gerhard Jaeger 62f74a479b Added Canon LiDE35. 2004-08-30 11:51:40 +00:00
Ullrich Sigwanz 6f92b1863e include warning about kernel version 2004-08-30 05:55:37 +00:00
Henning Geinitz 5ee41cb99f Added more clear comments. 2004-08-29 15:46:22 +00:00
Henning Geinitz f180126033 Added Epson 2580 and Nikon LS-50. 2004-08-29 15:44:55 +00:00
Stéphane Voltz 44065a4f5a - rename 'contrast' to 'offset' and 'highlight' to 'gain'.
Translations will need to be updated.
	- beginning of 610P/1220P codepath merge.
2004-08-25 19:51:58 +00:00
Henning Geinitz ce0b03e0bf Added Epson 2480 and Microtek Filmscan 35. 2004-08-24 16:12:50 +00:00
Henning Geinitz 3b1964354c Updated. 2004-08-19 18:07:17 +00:00
Henning Geinitz b61fcc4542 Added Lexmark and Xerox scanners. 2004-08-08 10:22:39 +00:00
Henning Geinitz b600c81c26 Added Mustek ScanExpress 1248 UB and new version of Mustek BearPaw 1200 CU Plus. 2004-08-08 10:00:02 +00:00
Gerard Klaver 456012cd96 url and status change 2004-08-04 16:32:23 +00:00
Gerard Klaver 67f90ced36 update info 2004-08-04 16:29:39 +00:00
Oliver Rauch a2e1375d62 *** empty log message *** 2004-08-04 11:26:51 +00:00
Henning Geinitz 713cdb5eb3 Testing list generation. 2004-08-03 18:03:51 +00:00
Henning Geinitz b723aeb859 Removed (backend now included). 2004-08-03 17:42:50 +00:00
Henning Geinitz 4f091999e8 Minor documentation updates. 2004-08-03 17:35:49 +00:00
Gerhard Jaeger 73b53d7811 Initial checkin. 2004-08-03 07:47:16 +00:00
Gerhard Jaeger 9cd6949c47 Added niash manpage. 2004-08-03 07:46:48 +00:00
Gerhard Jaeger 318b8add31 Added niash documentation stuff. 2004-08-03 07:46:22 +00:00
Gerard Klaver ce760e8fad added Logitech PageScan USB and Grantek Scopecam 2004-07-28 18:36:26 +00:00
Gerhard Jaeger 542c63509a Updated. 2004-07-26 15:14:14 +00:00
Karl Heinz Kremer 9318886c80 Updated version in epson.desc 2004-07-18 14:59:39 +00:00
Karl Heinz Kremer d909aa5f9b Moved RX-500 from unsupported.desc to epson.desc 2004-07-18 14:57:27 +00:00
Karl Heinz Kremer 51e5894920 Added RX-600 to epson.desc 2004-07-18 14:44:30 +00:00
Karl Heinz Kremer e4b49a2fa4 Added CX-5400 to epson.desc 2004-07-18 14:41:54 +00:00
Henning Geinitz 2dbe869cc0 Added some scanners. Removed Epson Perfection 3170 (now in epkowa). 2004-07-16 18:58:17 +00:00
Henning Geinitz 1a516e7a13 Added Epson Perfection 3170 Photo as it's reported to work with that backend. 2004-07-16 18:55:53 +00:00
Gerhard Jaeger 0d060705d3 Updated. 2004-07-16 12:04:45 +00:00
Gerhard Jaeger ff7b33f44f Update. 2004-07-16 11:37:19 +00:00
Gerhard Jaeger fdb647ead7 Fixed typo. 2004-07-16 11:35:07 +00:00
Gerhard Jaeger 57e14a1ea7 updated. 2004-07-16 11:34:01 +00:00
Gerhard Jaeger d0384d6d0f no longer needed. 2004-07-16 11:32:41 +00:00
Gerhard Jaeger 2c42298a29 Getting version information now out of the backends main file. 2004-07-16 11:32:04 +00:00
Henning Geinitz 8ae91c2ff6 Fixed manual page problems. 2004-07-12 17:30:30 +00:00
Henning Geinitz 1e15afbfb9 Removed dead link. 2004-07-09 19:24:47 +00:00
Henning Geinitz 00d9249273 New file. Added the scanners listed on the brother backend page. Used "untested"
status as we don't have confirmation that the backend actually works.
2004-07-09 16:03:48 +00:00
Gerhard Jaeger a17cba7eb2 Update. 2004-07-05 12:55:01 +00:00
Gerhard Jaeger a8577d20cb Changed status of CanoScan D660U. 2004-07-05 12:54:01 +00:00
Gerhard Jaeger 4ea5776b0a URL update. 2004-07-02 13:16:41 +00:00
Gerhard Jaeger 0610608f96 Update. 2004-07-02 13:14:20 +00:00
Gerhard Jaeger c71b8b0bce URL update, changed state of backend. 2004-07-02 13:13:44 +00:00
Gerhard Jaeger 925821e729 Removed unsupported devices, updated some states. 2004-07-02 13:06:20 +00:00
Frank Zago 2e06036a35 added support for Genius FS-1130 Colorpage Scanner. 2004-07-01 02:35:20 +00:00
Gerhard Jaeger ae16cd04b6 fixed floating point issues for SuSE kernels. 2004-06-30 13:43:27 +00:00
Henning Geinitz d7029b39f1 Added Microtek and Xerox scanners. 2004-06-28 18:36:28 +00:00
Henning Geinitz ae06a8a3c4 Yet another test. 2004-06-24 16:26:21 +00:00
Henning Geinitz 24c0c58a94 Test of list generation. 2004-06-24 16:14:44 +00:00
Gerhard Jaeger bba89aa83f removed Compac S4 100 (supported by the Plustek backend)
added various Plustek devices,
changed OpticPro m12 to OpticSlim M12
2004-06-24 08:02:40 +00:00
Rene Rebe 4897ea92fa * backend/avision.c, backend/avision.h, doc/sane-avision.man:
Fixed compilation warning (Bug #300399) and added a force-a3
  option, needed for A3 scanner returning bogus scan area definitions
2004-06-22 14:12:52 +00:00
Henning Geinitz 75a39c06d7 Updated to backend version 61. Lots of fixes for coarse calibration, scanning
speed and several scanners. For details, see gt68xx.CHANGES.
2004-06-18 09:49:32 +00:00
Henning Geinitz 99d1bc9aab New file. Lots of bugs and missing features for the gt68xx backend. 2004-06-18 09:45:50 +00:00
Stéphane Voltz 06ef6f1dbb - fixed overflows in 610P shading calibration coefficients
-  minor man update
	-  610P status change from minimal to good
2004-06-17 05:09:10 +00:00
Julien BLACHE 6de2f54c0c doc/Makefile.in: saned is in /usr/sbin, its manpage should go to section 8.
Fixed everything referring to saned(1) to refer to saned(8).
2004-06-13 15:25:13 +00:00
Mattias Ellert b9dfa61f90 Adding NEC Petiscan as unsupported 2004-06-13 13:44:38 +00:00
Henning Geinitz 875cc58b94 Fixed version number. 2004-06-10 09:05:25 +00:00
Henning Geinitz c94e8d952c Added Syscan TravelScan FS-531. 2004-06-08 16:25:12 +00:00
Henning Geinitz a33211805c Reduced scan area of Mustek Paragon 1200 A3 Pro. Removed warning
message. Increased support level to complete.
2004-06-08 11:34:02 +00:00
Gerhard Jaeger 8dee1e714a bumped up build number. 2004-06-08 09:31:14 +00:00
Henning Geinitz 7751b3b7eb Changed service name from "sane" to "sane-port". This is the
IANA registered service name for port 6566 (bug #300758).
2004-06-02 18:38:28 +00:00
Henning Geinitz 38a09ba8bc Mention special kernel patch. 2004-05-30 14:08:18 +00:00
Henning Geinitz d3b9dc8a6a Added Dell A920, Microtek 1850S and Plustek OpticPro m12. Removed HP,Scanjet
2300 (already in genesys.desc).
2004-05-28 18:40:01 +00:00
Henning Geinitz da5773b8cb Work around 8 char limit for dynamic loading on OS/2 (patch from Franz Bakan
<fbakan@gmx.net>).
2004-05-24 19:16:41 +00:00
Ulrich Deiters 19fed4c4f8 Ulrich Deiters: removed option "OPT_PAGE" from Canon-SCSI backend 2004-05-21 20:35:26 +00:00
Henning Geinitz e08afb1214 Added more Canon cartridge scanners. Updated Visioneer Paperport 3100b. 2004-05-18 18:59:22 +00:00
Ulrich Deiters 6be161afe4 Ulrich Deiters: memory leak plugged, option settings for FS2700 corrected 2004-05-17 15:09:57 +00:00
Gerhard Jaeger f311994cf3 update. 2004-05-15 13:58:07 +00:00
Gerhard Jaeger eb9dcc2269 bumped up build number. 2004-05-15 13:57:45 +00:00
Henning Geinitz 71fb04233f Added link to more info about Microtek ScanMaker 3630. 2004-04-30 17:27:13 +00:00
Oliver Schwartz df8e3cf73e Added Benq 640BT, Change status of Epson 1670 to 'good' 2004-04-29 16:08:54 +00:00
Henning Geinitz 019cf37cc9 Removed comments from some scanners as the chipset is known now. 2004-04-24 15:49:44 +00:00
Henning Geinitz c51bab3093 Added Lexmark X5130, UMAX Astra 4000 and 4600. 2004-04-24 15:48:19 +00:00
Jochen Eisinger 6586581435 2004-04-24 Jochen Eisinger <jochen@penguin-breeder.org>
* doc/sane-usb.man: added comment about devmode not working
	  with current (2.6.3-2.6.5) 2.6 kernels
2004-04-24 10:42:00 +00:00
Gerhard Jaeger a332b65436 updates. 2004-04-23 14:58:21 +00:00
Henning Geinitz f08a25de9d Added Canon IS-32. 2004-04-19 18:02:59 +00:00
Henning Geinitz f723898b2b Minor fixes for Mustek BearPaw 2448 TA Plus. 2004-04-19 18:01:48 +00:00
Gerhard Jaeger 5c295cea4b update. 2004-04-14 19:31:27 +00:00
Gerhard Jaeger 6f4c05ffaa added RevScan Orange R48Ti. 2004-04-14 19:21:53 +00:00
Gerhard Jaeger 2859bc1db2 added to make kernel-module compilation easier. 2004-04-14 19:14:13 +00:00
Henning Geinitz c187441e94 Minor fixes for Mustek A3 USB, Genius ColorPage Vivid4 and Mustek BearPaw 2448
CS/TA Plus.
2004-04-10 17:30:36 +00:00
Jochen Eisinger 82737c0daf 2004-04-10 Jochen Eisinger <jochen@penguin-breeder.org>
* tools/sane-find-scanner.c, doc/sane-mustek_pp.man,
	  doc/sane-find-scanner.man: added support for detecting
	  mustek parallel port scanners.
2004-04-10 09:39:16 +00:00
Henning Geinitz 31aff4be69 Testing website sane-backends-cvs.html generation scripts. 2004-04-06 16:51:54 +00:00
m. allan noah 7c77fd12d7 updated to be more accurate for usb scanners 2004-04-06 13:04:35 +00:00
Henning Geinitz 6d0f342927 Removed Canon D660. Now supported by plustek backend. 2004-04-04 19:13:27 +00:00
Henning Geinitz 3593f24a3d Added BGR color order for pixel mode. Plustek OpticPro U16B works
in color mode now. Made 600 dpi mode for Mustek BearPaw 2400 TA
	  Plus a bit faster. Changed Mustek ScanExpress A3 linedistance
	  correction. Added detection of Visioneer Onetouch 7300.
2004-04-04 18:59:49 +00:00
Gerhard Jaeger 733964f181 update. 2004-04-04 13:50:49 +00:00
Gerhard Jaeger 5912ce7583 added Canon D660U. 2004-04-04 13:50:06 +00:00
Henning Geinitz 8ec8a3a0f4 Added Relisys Episode scanner. 2004-04-02 20:52:59 +00:00
Henning Geinitz c83e7ec87c Added Avigramm Minidoc, Medion MD 41260, and Nikon LS 50 ED. Removed Genius
Colorpage Vivid III as it may work with the u12 backend.
2004-03-28 18:57:43 +00:00
Henning Geinitz 5c89f7f6a8 Added Agfa Studiostar. 2004-03-28 18:52:49 +00:00
Henning Geinitz 46ed7dab4d Plustek U16B: Added GT68XX_FLAG_SE_2400. Fixed color order.Increased debug level
for setup_scan. Fixed CCD ocarse calibration.
2004-03-28 18:26:38 +00:00
Peter Kirchgessner 7ca05daa2c Add environment SANE_HP_KEEPOPEN... 2004-03-27 14:10:43 +00:00
Peter Kirchgessner 815b2c5f09 Change backend version number 2004-03-27 14:09:14 +00:00
Henning Geinitz 7d872c2f94 Really add the Tevion MD 40420. 2004-03-25 20:24:52 +00:00
Henning Geinitz b816418bb9 Moved Plustek OpticPro S(T)28 to genesys.desc. 2004-03-25 20:22:24 +00:00
Henning Geinitz 781c5aeaeb Added Tevion MD 40420. Moved Plustek OpticPro S(T)28 to genesys.desc. 2004-03-25 20:21:36 +00:00
Henning Geinitz 7702a9e95c Added some Microtek and Agfa scanners. 2004-03-21 17:07:57 +00:00
Henning Geinitz d7e5361782 Added detection of Mustek ScanExpress 1200 FS. 2004-03-21 12:35:39 +00:00
Karl Heinz Kremer c7340906d0 Added Perfection 4870 and CX-6400 (removed this model from unsupported.desc) 2004-03-19 21:18:32 +00:00
Henning Geinitz aafcfe6a8e Genius Vivid 4xe now has color order RGB. Removed 50 dpi for Mustek BearPaw 2448
as that resolution doesn't work. Make sure that the lamp of the Mustek A3 USB
gets warmed up. It's a CIS scanner with a lamp. That code is untested. Full scan
starts scanning from the start position of the white strip now. Added detection
for Genius Vivid 1200 EX. Fixed product id of Mustek BearPaw 2448 TA Plus. Other
minor updates.
2004-03-19 18:55:35 +00:00
Henning Geinitz 12967b4bd1 Added Mustek A3 EP. Removed Plustek OpticPro ST48. 2004-03-14 19:55:27 +00:00
Henning Geinitz 516ed574a2 Added Plustek OpticPro ST48. 2004-03-14 19:26:34 +00:00
Henning Geinitz 3eadbfd8a5 Added scanner ids (from Marcel Pol). Added more documentation. Added "chmod
a+rw" alternative.
2004-03-14 18:25:02 +00:00
Henning Geinitz c34b2e9e31 Added Vantas 3000. Added some links. 2004-03-13 11:54:03 +00:00
Stéphane Voltz e973af58e8 - finished ECP support for 1220P/2000P
- added low level communication for 610P
	- added scanner detection for 610P
	- misc doc updates
2004-03-09 06:12:27 +00:00
Henning Geinitz 389b608312 Moved all scanners that may be supported by the genesys backend to
genesys.desc. Added links to scanner pages.
2004-03-08 20:30:10 +00:00
Henning Geinitz 72558a931e Moved all scanners that may be supported by the genesys backend to
genesys.desc. Added Agfa 1212 P.
2004-03-08 19:59:00 +00:00
Gerhard Jaeger fafecc251d Readded OpticPro S28. 2004-03-03 20:50:21 +00:00
Gerhard Jaeger 37cd071936 Update. 2004-03-03 20:44:26 +00:00
Gerhard Jaeger 92fd6b2c4d Fixed missing status. 2004-03-03 20:43:50 +00:00
Gerhard Jaeger a0549c7416 Updated Plustek section. 2004-03-03 20:42:05 +00:00
Henning Geinitz eff50aa24f Added link for HP ScanJet 8290. Added Logitec PageScan Color. 2004-03-02 21:31:35 +00:00
Henning Geinitz cae6ee91fd Added workaround for toggle = data0 chipset bug. Fixes bug #300323. 2004-03-02 21:00:46 +00:00
Frank Zago b8ce281b95 Potentially supported scanners by the genesys backend. 2004-03-02 04:13:26 +00:00
Frank Zago 1929019805 Added inquiry for Genius FS1130. 2004-03-02 03:29:51 +00:00
Karl Heinz Kremer 245d5b87dc Corrected typo: Default function level is B3, and not B5. 2004-03-02 00:33:21 +00:00
Henning Geinitz a2e686d667 Added support for asking for pressing a key before scanning a page in a batch
scan. Patch from Dominik Fischer <dom_fischer@web.de>.
2004-02-22 11:17:49 +00:00
Henning Geinitz 7824953c94 Added UMAX Astra 1600U as this scanner is reported to work as "well" as the 2000U. 2004-02-14 20:15:22 +00:00
Henning Geinitz 1f5674ee82 Added HP ScanJet 4670 and Tamarack Artiscan 9600 pro 36. Removed Plustek
OpticSlim 2400.
2004-02-14 20:13:37 +00:00
Henning Geinitz aa16ce14fd Fixed missing ChangeLog entries. Looks like they didn't get committed last time. 2004-02-14 18:56:39 +00:00
Frank Zago 04dec9382a Added partial support for models KV-SS55EX, KV-S2025C, KV-S2045C and KV-S2065L. 2004-02-12 01:59:53 +00:00
Henning Geinitz 820b9ba269 Added basic support for Plustek OpticSlim 2400. Fixed calibration debug output. 2004-02-10 19:02:03 +00:00
Frank Zago fafc1de3df Added new scanner Relisys RELI 4816, marked Relisys AVEC 2412 as tested. 2004-02-08 15:27:55 +00:00
Oliver Rauch af4a252e02 sane-umax: bugfix for DOR mode 2004-02-08 14:02:26 +00:00
Henning Geinitz 9e4cc8f137 Added Genius Colorpage Vivid 1200EX and Mustek Paragon 800 II EP. 2004-02-07 15:14:44 +00:00
Oliver Schwartz 7d7df459ee Fixed resolutions for Epson 1670 2004-02-01 13:32:26 +00:00
Henning Geinitz cbffe2300f Added Mustek BearPaw 4800TA Pro II. 2004-01-30 17:12:42 +00:00
Gerhard Jaeger da7ec7ea25 update. 2004-01-19 19:37:48 +00:00
Gerhard Jaeger fe3a5d46b9 initial checkin. 2004-01-19 19:37:29 +00:00
Henning Geinitz 6026b31f36 Debug options are only enabled if the debug level is 1 and higher. Added product
id 0x0402 for Plustek U16B.
2004-01-19 17:35:57 +00:00
Henning Geinitz aa55d8caf7 Added Lexmark X74. 2004-01-17 22:08:28 +00:00
Henning Geinitz afbce57aae scanimage is in section 1. 2004-01-17 22:07:57 +00:00
Gerard Klaver 6ca6597b05 Option hange from WHITE_LEVEL to WHITE_LEVEL_R, WHITE_LEVEL_G and WHITE_LEVEL_B and text update. 2004-01-15 18:17:57 +00:00
Gerhard Jaeger 4a17860c98 fixed wrong man-page reference, status updates. 2004-01-14 19:05:35 +00:00
Henning Geinitz 561b7501e1 Added Packard Bell Diamond 2450. 2004-01-13 21:07:16 +00:00
Henning Geinitz 8ad178343b Epson 1670 is supported by SnapScan backend now. 2004-01-13 21:05:01 +00:00
Henning Geinitz bbbc252993 Added several Canon, HP, Plustek, and UMAX scanners. 2004-01-13 21:03:10 +00:00
Gerhard Jaeger 3040657670 added missing explanation. Bug #300441. 2004-01-13 07:37:02 +00:00
Oliver Rauch c287806dc0 *** empty log message *** 2004-01-12 19:54:31 +00:00
Matthew Duggan 656a9d8be3 2004-01-12 Matthew Duggan <stauff1@users.sourceforge.net>
* backend/canon_pp-dev.c backend/canon_pp-io.c backend/canon_pp.c
          backend/canon_pp.h: Fix various compile warnings (Bug #300407).
          Also fix bug in parsing config file.
        * doc/descriptions/canon_pp.desc: Bump version number.
2004-01-11 22:24:07 +00:00
Henning Geinitz cf35c4fbf0 Fixed some broken links. 2004-01-11 18:08:26 +00:00
Oliver Rauch d3f4c2b73a *** empty log message *** 2004-01-10 11:24:26 +00:00
Oliver Rauch 7637643810 Updating umax documentation files 2004-01-10 11:13:14 +00:00
Henning Geinitz 6ae442bf94 Added HP Scanjet 4600 and Quato scanners. Updated Epson 1270. 2004-01-09 21:13:45 +00:00
Henning Geinitz e6c9fe3cf7 Only one option can be used at the same time. 2004-01-09 21:11:47 +00:00
Gerhard Jaeger 7d3ec3869c update. 2004-01-09 14:21:13 +00:00
Gerhard Jaeger b9afb831cd added u12 subdirectory. 2004-01-09 14:20:16 +00:00
Gerhard Jaeger 88d7765591 initial checkin. 2004-01-09 12:21:54 +00:00
Gerhard Jaeger b934b0b294 added ENVIRONMENT information and did some minor updates. 2004-01-09 12:20:53 +00:00
Gerhard Jaeger c1d7234ba6 Status updates. 2004-01-09 12:20:00 +00:00
Oliver Rauch 872a4544c9 umax backend: disabled quality calibration for umax Astra 2200 SU via USB 2004-01-07 23:01:48 +00:00
Gerhard Jaeger ba34f966e5 added u12 backend man-page. 2004-01-06 09:49:48 +00:00
Gerhard Jaeger eeb26db8d2 Fixed Vivid III entry. 2004-01-06 09:49:30 +00:00
Henning Geinitz 46dfbad619 Added Visioneer 8820 and TCE S450. 2004-01-05 21:47:08 +00:00
Gerhard Jaeger d219ef73a0 added u12 backend man-page. 2004-01-05 20:34:48 +00:00
Gerhard Jaeger a20efe37fb initial checkin. 2004-01-05 20:34:09 +00:00
Gerhard Jaeger d05c973c18 removed Plustek OpticPro U12, UT12, 1212U, Genius Colorpage Vivid III, as they
should be supported now.
2004-01-05 20:32:49 +00:00
Henning Geinitz a4dc00b0ed Fixed a bug in the stop scan function for Plustek U16b. Added support for Genius
Vivid4xe.
2004-01-05 18:16:04 +00:00
Henning Geinitz d565a760a8 Fixed URL. 2003-12-31 10:19:38 +00:00
Henning Geinitz fc8aa89a41 Added HP and Epson scanners. 2003-12-31 10:14:44 +00:00
Henning Geinitz 19274555a4 Updated/added several Medion scanners. 2003-12-27 12:39:14 +00:00
Henning Geinitz 25127cff78 Fixed wrong version number. 2003-12-25 20:51:18 +00:00
Henning Geinitz 1e871b6f1a Fixed typos. 2003-12-25 20:37:19 +00:00
Henning Geinitz 7c77cc90e1 Removed Mustek Paragon 600 II EP/ED. Added Genius Colorpage-EP. 2003-12-25 20:36:48 +00:00
Henning Geinitz 08486e6be4 Added support for Mustek Paragon 600 II EP (SCSI-over-parallel port). This is
based on a patch from James Perry. Support for libiee1284 is missing until
now. Closes bug #300143.
2003-12-25 20:27:49 +00:00
Henning Geinitz 234f24f694 Added information that this backend will be included soon. Fixed "Snapscan" to
"SnapScan" (bug #300394).
2003-12-25 08:47:16 +00:00
Henning Geinitz c12df77d86 Added more information about the Benq Scanprisa 640P, Boder SmartSCan Office,
and Trust CombiScan 19200.
2003-12-23 20:05:46 +00:00
Henning Geinitz 0777c60aa7 Don't include linux/videodev.h kernel header anymore. Use own defines
instead. Fixes bug #300324.
2003-12-21 22:51:42 +00:00
Henning Geinitz a16dfafd6a Fixed initial value for --fixed-constraint-range (bug #300388). 2003-12-21 20:59:59 +00:00
Gerhard Jaeger 4a8bf3059c new version, minor fixes. 2003-12-18 13:21:11 +00:00
Gerhard Jaeger 86ca2d087c new backend version. 2003-12-18 13:20:16 +00:00
Henning Geinitz 9eee10f70a Added Canon 3200F. 2003-12-16 20:45:53 +00:00
Henning Geinitz ff2e1ba2cc Removed (now again in mustek_pp backend). 2003-12-15 20:40:59 +00:00
Henning Geinitz dc41ea490d Added some scanners. 2003-12-15 20:39:59 +00:00
Eugene S. Weiss 746872a6db Fixed bug #300133
Fixed bug #300123

Small fix to man page.
2003-12-14 20:52:01 +00:00
Henning Geinitz 0de37be6f6 Updated code for Genius Vivid 4x and Mustek ScanExpress A3 USB. Added Genius
Colorpage Vivid3 V2 and Googlegear 2000 as supported devices.
2003-12-14 19:02:32 +00:00
Henning Geinitz a044f2a6ff Added and updated some scanners. 2003-12-14 16:49:07 +00:00
Michael Herder 6b33a0abf0 * backend/artec_eplus48u.c backend/artec_eplus48u.h
backend/artec_eplus48u.conf: added
                  experimental support for the Artec E+ Pro
	  fixed sane-Bugs-300261 (doesn't compile when
	  NDEBUG is defined)
2003-12-12 06:55:45 +00:00