Henning Geinitz
a4e842d946
Minor cleanup from the jpeg move. Reverted frontend link order.
2003-07-26 21:40:06 +00:00
Henning Geinitz
3a5b52b174
Tag CCD scanners as unsupported and mention that they work in 1.0.9 or
...
earlier.
2003-07-25 07:46:56 +00:00
Henning Geinitz
d5ce45d9c5
Added Fujitsu 1200CUS to man page, .conf and .desc. Changed .conf file to be
...
more readable. Added RevScan 19200i to .conf file. Added Plustek U16B to
.desc and .conf, updated UT16B.
2003-07-25 07:41:58 +00:00
Henning Geinitz
1f2630a99f
Tag CCD scanners as unsupported and mention that they work in 1.0.9 or
...
earlier.
2003-07-22 21:01:16 +00:00
Oliver Schwartz
ad19d380ca
Changed status keywords for snapscan backend
2003-07-22 20:53:44 +00:00
Matthew Duggan
2c304633fd
2003-07-22 Matthew Duggan <stauff1@users.sourceforge.net>
...
* doc/descriptions/canon_pp.desc: Updated to use new status values.
2003-07-21 22:53:09 +00:00
Henning Geinitz
95a1714a1b
Added more information for Canon 9900F.
2003-07-21 21:09:37 +00:00
Stéphane Voltz
c6edbd0ebc
removed unwanted status line for backend
2003-07-21 16:40:38 +00:00
Stéphane Voltz
f6de2a3280
Fixed on forgotten status
2003-07-20 20:02:03 +00:00
Oliver Rauch
61e964a0a1
corrected wrong backend version number in umax.desc
2003-07-20 13:00:21 +00:00
Oliver Rauch
9f15735eea
Changed status messages in umax.desc
2003-07-20 12:56:39 +00:00
Frank Zago
a44da4ed1e
Updated specs to new format.
2003-07-19 15:37:08 +00:00
Frank Zago
38ee95dd3e
Added new inquiry.
2003-07-19 15:36:38 +00:00
Peter Fales
5bc3bef7a1
Remove status and correct typo in comment
2003-07-19 12:53:22 +00:00
Henning Geinitz
230881860d
Sorted (more or less) alphabetically. Added some Canon and Hewlett-Packard
...
scanners.
2003-07-19 12:14:57 +00:00
Henning Geinitz
79efce6bd9
Converted to use new :status values.
2003-07-19 12:04:09 +00:00
Henning Geinitz
b3fd92c684
Added support for detecting USB chipsets to sane-find-scanner.
2003-07-18 12:11:01 +00:00
Stéphane Voltz
4ef98a437a
- updated to use new :status
2003-07-15 05:10:07 +00:00
Henning Geinitz
dbba9c3560
Henning Meier-Geinitz <henning@meier-geinitz.de>
2003-07-10 17:51:59 +00:00
Henning Geinitz
e819bbe6ce
Added Corex and Relisys scanners. Updated Canon and HP scanners.
2003-07-10 17:50:10 +00:00
Henning Geinitz
8b2de7255e
Added Memorex, Visioneer and Xerox scanners. Updated information for Visioneer
...
scanners.
2003-07-01 11:05:25 +00:00
Henning Geinitz
28544822b0
Update version.
2003-06-28 21:06:06 +00:00
Henning Geinitz
e0a4557af6
Added Visioneer OneTouch 5800 USB.
2003-06-28 21:05:15 +00:00
Henning Geinitz
22a09b469e
Added Brother and Microtek scanners.
2003-06-25 21:06:48 +00:00
Michael Herder
a94b1f5493
*** empty log message ***
2003-06-20 09:52:01 +00:00
Michael Herder
2450d819c0
*** empty log message ***
2003-06-20 05:11:51 +00:00
Peter Fales
d952110045
Update status for dc240 and dc25
2003-06-19 22:21:10 +00:00
Simon Munton
46a88aa8af
Updated status fields in description file for PIE scanners
2003-06-19 20:29:53 +00:00
Eddy De Greef
3269c94dc0
Updated status fields of CIS type scanners.
2003-06-19 19:37:47 +00:00
Henning Geinitz
810a208634
Updated to new status system (this time, really!).
2003-06-19 15:52:26 +00:00
Henning Geinitz
e5a06cfc13
Updated to new status system. The status values are sometimes guessed from the
...
documentation.
2003-06-19 15:21:13 +00:00
Henning Geinitz
a106f6d8e7
Added Benq parport scanners.
2003-06-19 14:48:26 +00:00
Henning Geinitz
446df045df
Updated to new status system. Added "unmaintained" where appropriate. The
...
status values are sometimes guessed from the documentation.
2003-06-19 14:42:29 +00:00
Henning Geinitz
29635dcec2
Added RevScan 19200i. Updated device status entries.
2003-06-19 14:31:15 +00:00
Henning Geinitz
a688ca9867
Updated according to descriptions.txt.
2003-06-19 14:29:29 +00:00
Henning Geinitz
42ee3b2788
Changed unmaintained tag to lowercase.
2003-06-19 14:24:30 +00:00
Henning Geinitz
ac15bc78b3
Explained the new status values. Removed reference to emacs-lisp code for generation of HTML
...
files. Explained unsupported.desc.
2003-06-18 09:21:32 +00:00
Henning Geinitz
e05af61d7a
Added Canon D2400UF and IS 12.
2003-06-15 22:42:09 +00:00
Henning Geinitz
bc4e628309
Removed link to www.tamarack.net. Hostname is no longer in DNS.
2003-06-13 10:25:44 +00:00
Henning Geinitz
e7d9aefebe
Removed :new marker.
2003-06-13 10:22:05 +00:00
Henning Geinitz
496482374d
Added link for HP 5550c.
2003-06-13 10:20:10 +00:00
Henning Geinitz
f18e64db7b
Added Canon 8000F. More info for Avision/Umax scanners.
2003-06-09 09:21:18 +00:00
Henning Geinitz
b5fe663aa9
Added Microtek 336 CX.
2003-06-06 12:06:37 +00:00
Oliver Schirrmeister
f9bec2f06c
remove SP15 code
...
sane_open acturally opens the device you request
2003-06-06 09:47:24 +00:00
Henning Geinitz
4526a711f4
Don't check if the firmware is loaded. The check seems to confuse the USB system on some UHCI chips.
2003-06-05 09:58:45 +00:00
Henning Geinitz
aa54731584
Mention IPv6. Bump version number.
2003-05-30 18:10:04 +00:00
Henning Geinitz
2e543f6c77
Added link for Umax astra 4700.
2003-05-27 21:38:40 +00:00
Henning Geinitz
f8e1fdb037
Added link for Spot scanners.
2003-05-26 23:44:25 +00:00
Henning Geinitz
f1d003fd3c
Add option -nodepage to man2html to avoid missing lines in the html output.
2003-05-26 23:34:56 +00:00
Henning Geinitz
e5e72be57e
Added DigitDia 3600.
2003-05-25 11:00:24 +00:00
Henning Geinitz
c1c7ab1a46
Added more information for Artec and Visioneer/Primax scanners.
2003-05-22 20:08:35 +00:00
Henning Geinitz
18cf4247a3
Primax Compact 4800 SCSI is reported to work.
2003-05-22 20:06:53 +00:00
Gerhard Jaeger
04fe542971
Critical bugfix in CIS calibration, to make the devices CanoScan 650, 1220 and
...
1240 work again.
2003-05-18 16:58:18 +00:00
Henning Geinitz
ddfd143eaa
Added Mustek ScanMagic 9636P.
2003-05-18 15:21:03 +00:00
Henning Geinitz
ff87d2944d
Minor fix for Spot scanners.
2003-05-16 21:10:57 +00:00
Gerhard Jaeger
d5f59d5603
Major bug-fix release...
2003-05-15 17:19:32 +00:00
Henning Geinitz
5a5dd8adb0
Fixed wrong example.
2003-05-15 11:09:54 +00:00
Henning Geinitz
a821b8ae19
Updates for Canon scanners. Added Spot scanners.
2003-05-14 23:17:29 +00:00
Rene Rebe
dd890f193f
tiny typo - thanks Henning
2003-05-09 10:49:15 +00:00
Rene Rebe
caa3c7f853
update to the tatest avision backend including fix for segmentation-fault
...
when no config file is present.
2003-05-09 01:29:50 +00:00
Michael Herder
f9fecd629b
*** empty log message ***
2003-05-06 09:17:33 +00:00
Henning Geinitz
895ab09f6a
Disabled object_position. That should fix the Ricoh IS-420.
2003-05-03 16:13:59 +00:00
Oliver Rauch
ac69383660
umax scsi backend documentation update
2003-05-01 20:20:23 +00:00
Oliver Rauch
24f6d3563b
Update of umax-scsi backend
2003-05-01 20:19:31 +00:00
Henning Geinitz
735cc889d4
Updated info on Artec, Canon and HP scanners.
2003-04-30 23:23:59 +00:00
Henning Geinitz
6cbe39f1ef
Only use latex if available.
2003-04-30 23:12:17 +00:00
Oliver Schwartz
590274b705
SnapScan backend 1.4.26
2003-04-30 20:49:40 +00:00
Henning Geinitz
2b050f4e08
Added more information for the HP Scanjet 2300c.
2003-04-27 12:49:43 +00:00
Henning Geinitz
05c12190be
Added Genius 3x as working scanner, removed testing flag. Added Artec 2000 e+
...
to manpage. Added detection for the Plustek OpticPro U16B.
2003-04-27 12:43:43 +00:00
Henning Geinitz
2dc03a9113
Added Genius 3x as working scanner, removed testing flag. Added Artec 2000 e+
...
to manpage. Added detection for the Plustek OpticPro U16B.
2003-04-27 12:41:47 +00:00
Henning Geinitz
1b983df1ab
Added Visioneer OneTouch 4800 USB. Added more information for the Genius
...
ColorPage HR7X Slim and Microtek Scanport 3000.
2003-04-26 12:18:27 +00:00
Henning Geinitz
8c0e8054f7
Ricoh IS-420 doesn't seem to work out-of-the-box.
2003-04-26 12:15:24 +00:00
Henning Geinitz
594191313b
Added some more details for SCSI adapters.
2003-04-26 12:13:21 +00:00
Frank Zago
c5a46bf786
Updated version.
2003-04-24 03:55:07 +00:00
Frank Zago
3057afd6bf
Added new calibration algorithm.
2003-04-24 03:17:16 +00:00
Henning Geinitz
2a36b0592b
Removed Epson Perfection 660 (now supported by snapscan backend), Primax Jewel
...
4800 (teco2). Added Enhans/E-Lux j-6121 and Visioneer OneTouch 5300 USB.
2003-04-20 14:20:05 +00:00
Henning Geinitz
d539755da5
The lists of supported devices are now generated and installed by default.
2003-04-20 14:00:51 +00:00
Frank Zago
3c03bf82e6
Primax Jewel is now supported. Fixed a typo.
2003-04-19 15:59:08 +00:00
Frank Zago
500d1b48cb
Added support for Relisys AVEC II S3 (VM3564) and Primax Jewel 4800 (VM356A). Patch from Gerard Klaver.
2003-04-19 03:50:22 +00:00
Henning Geinitz
df67be5471
Added comments to explain the reasons for not including these backends into SANE.
2003-04-17 12:13:22 +00:00
Henning Geinitz
e08f5293e3
Removed. Website is dead. No response from author.
2003-04-17 11:50:51 +00:00
Henning Geinitz
adaec49a9b
Removed. Website has been dead for years. No response from author.
2003-04-17 11:46:36 +00:00
Henning Geinitz
89ed81095b
Added new marker.
2003-04-17 10:52:22 +00:00
Henning Geinitz
4380aba88d
Moved file as the backend is included now.
2003-04-17 09:30:57 +00:00
Henning Geinitz
517751ff09
Added hp5400 backend from Martijn van Oosterhout <kleptog@svana.org> and
...
Thomas Soumarmon <soumarmt@nerim.net>. Changed to use sanei_usb instead of
direct /dev/usb/scanner access. Added manual page. Fixed some portablility
issues and some warnings. Added SANE headers.
2003-04-17 09:19:25 +00:00
Henning Geinitz
a563d4735d
Added information about Hewlett-Packard and Mustek scanners.
2003-04-16 09:49:56 +00:00
Henning Geinitz
7caeb1476f
Added EXAMPLES section.
2003-04-16 09:12:23 +00:00
Henning Geinitz
441353962b
Mention alpha quality. Add maintainer address.
2003-04-15 14:55:10 +00:00
Henning Geinitz
1a4455d2dd
Removed, now included in SANE distribution.
2003-04-15 09:59:54 +00:00
Henning Geinitz
87387511b0
Added IBM backend for the IBM 2456, the Ricoh IS-420 and maybe the IS-410 and
...
IS-430 from mf <massifr@tiscalinet.it>. Added manual page, fixed some
warnings, Added detection for IS-410 and IS-430.
2003-04-15 09:54:00 +00:00
Henning Geinitz
b05d98e145
Updated HP Scanjet 35XX, Medion MD 6228, and Umax Astra 4700 entries. Added some Mustek
...
and Primax scanners.
2003-04-14 19:56:28 +00:00
Henning Geinitz
edd2bc1d13
Added SEE ALSO section.
2003-04-13 10:34:01 +00:00
Henning Geinitz
c07df2fa80
--batch format doesn't work, only --batch=format.
2003-04-11 19:26:40 +00:00
Henning Geinitz
f791da258c
Added Mustek P 3600 A3 Pro.
2003-04-11 09:53:09 +00:00
Henning Geinitz
4d31f673c9
Added information about #sane IRC channel. Formatting changes.
2003-04-11 09:48:14 +00:00
Henning Geinitz
eda0c4bc5e
Updated Mustek BearPaw 1200 CU Plus white strip value. Set Mustek ScanExpress
...
A3 USB to CCD. Black mark may be still wrong. Minor formatting changes in the
manpage. Decreased ScanExpress A3 USB status to alpha because of CIS/CCD
change.
2003-04-11 09:37:24 +00:00
Henning Geinitz
04dd7d101f
Added support for OS/2 (from Franz Bakan <fbakan@gmx.net>).
2003-04-10 08:36:10 +00:00
Nathaniel Rutman
2b0ea7786e
Removed last change in offset/gain calculation, which croaked for some
...
cases. Give up early if we can't talk on the USB.
Added option to force scanner recalibration.
2003-04-05 19:44:04 +00:00
Oliver Schwartz
e30553a7c5
SnapScan backend 1.4.25
2003-04-02 21:01:07 +00:00
Henning Geinitz
94c80d74aa
Artec website works again, I should have checked that before committing.
2003-04-02 14:48:34 +00:00
Henning Geinitz
a2e76b2942
Remove Chris Pinkham as active maintainer because his primary email address
...
bounces, the website is dead and he doesn't respond to mails to other
addresses. Marked email addresses and website as dead. Fixed AT3 misdectection
that was on the TODO list for some time.
2003-04-02 14:40:48 +00:00
Henning Geinitz
52c6a7f13d
Reorganization. Updated DEVELOPER'S DOCUMENTATION. Rewrote PROBLEMS in a more
...
user-centric way. Added "HOW CAN YOU HELP" section. Added paragraph about SANE
device lists. Updated CONTACT section. Minor additions to the gt68xx and
plustek entries. Minor spelling fixes.
2003-04-02 11:59:31 +00:00
Henning Geinitz
5669edd6d0
Added info about $PATH. Minor formatting fixes.
2003-04-02 09:27:41 +00:00
Henning Geinitz
088281c4e1
Added support for IPv6. Updated manpages. Patch from Julien BLACHE
...
<jb@jblache.org>.
2003-03-30 19:07:18 +00:00
Henning Geinitz
e1b27e1c18
Added Medion MD 6228, Microtek ScanPort 3000, and PIE Primefilm 1800u.
2003-03-29 23:53:41 +00:00
Rene Rebe
8ce6e0d515
Updated the avision backend to latest build. This includes user-space
...
USB support and OS/2 thread handling.
2003-03-25 01:43:35 +00:00
Henning Geinitz
bfa506e446
Added Canon CanoScan FB620U. Added more info for HP ScanJet 3500c.
2003-03-24 18:22:42 +00:00
Rene Rebe
aafe742829
fixed typo in the sanei_usb manpage
2003-03-23 22:55:48 +00:00
Henning Geinitz
d2ebe3dca4
Added Canon LIDE 50, IBM ADF Color Scanner, Plustek Spectra ADF.
2003-03-20 20:05:57 +00:00
Henning Geinitz
39a2dd7f0a
Added some Boeder, Brother, HP and Trust scanners.
2003-03-13 17:27:31 +00:00
Henning Geinitz
a84d4a611f
Added Packard Bell Diamond 1200 Plus to .desc and manpage. New flag to avoid
...
running stop_scan before doing a scan. The Windows firmware of the BearPaw
1200 CU Plus doesn't seem to like that.
2003-03-13 17:18:29 +00:00
Henning Geinitz
f87050d7b0
Removed link to everex (timeout).
2003-03-09 20:05:12 +00:00
Henning Geinitz
8d9c13ed82
Minor debug message updates. Fixed a little bug in sane_control_option (gamma
...
control). Removed the signal blocking again. That only hides the segfault in
sanei_scsi. Check if there are documents in ADF for Paragon 2. Otherwise
return error. Fix some minor issues in reading the config file.
2003-03-07 19:31:26 +00:00
Peter Fales
cd8e633206
Update Kodak URLs
2003-03-07 14:12:00 +00:00
Henning Geinitz
0bb508a879
Small requests are done with a response buffer of 8 bytes (instead of 64)
...
now. Looks like GT-6816 based scanners return 8 bytes if the firmware is
loaded and 64 bytes if it's not loaded. Changed GT-6816 firmware check to
ignore errors from above change. GT-6816 scanners work with the BSDs now (at
least once). Updated manpage concerning the BSDs.
2003-03-06 14:27:54 +00:00
Oliver Schirrmeister
f9d7350534
* backend/fujitsu.c, backend/fujitsu.h: renamed some variables
...
* backend/fujitsu.c: gray duplex scanning now works with the 4097D
when disconnect is enabled in the scsi-controller
* doc/descriptions/unsupported.desc: remove fujitsu fi4120C
* doc/descriptions/fujitsu.desc added fi4120C, ScanParter 93GX
2003-03-05 12:56:44 +00:00
Henning Geinitz
a4b5a465fd
Removed Umax AstraSlim (now supported by artec_eplus48u backend).
2003-03-04 23:58:23 +00:00
Henning Geinitz
bf357a6b9a
Changed the example to use /dev/sg0 instead of /dev/sge.
2003-03-04 23:55:47 +00:00
Gerhard Jaeger
ca786b2c28
Bug-fix update for Genius, HP2100c and EPSON Photo devices.
2003-03-03 14:34:20 +00:00
Henning Geinitz
a04ea4b251
Make sure that the firmware for plustek-like scanners is loaded. Didn't work
...
for Genius vivid3xe. Added both Genius scanners to man page. Removed warning
from Genius Vivid3xe.
2003-03-02 22:08:50 +00:00
Michael Herder
6520e41917
*** empty log message ***
2003-03-02 06:55:18 +00:00
Henning Geinitz
f8b385aca1
Updated Microtek scanners. Added Umax AstraSlim SE.
2003-03-01 17:39:57 +00:00
Henning Geinitz
175a070af6
Added Ricoh IS-430.
2003-03-01 17:38:27 +00:00
Ulrich Deiters
bf3546ca14
adjusted backend/canon-sane.c to use the new sanei_constrain_value()
...
made some cosmetic changes to reduce the number of compiler warnings
2003-02-28 09:35:24 +00:00
Henning Geinitz
4558610025
Added Compaq S4 100 and Microtek Scanmaker 4800.
2003-02-27 23:06:09 +00:00
Henning Geinitz
4b00890161
Added Genius Colorpage Vivid3xe. Added request_type and request fields to the
...
command set. Request is 0x01 or 0x04.
2003-02-27 17:31:52 +00:00
Ulrich Deiters
540656fd72
mentioned the new FB1200S in the man pages
2003-02-26 17:52:40 +00:00
Henning Geinitz
0dcf319756
Added :new token.
2003-02-26 15:34:27 +00:00
Henning Geinitz
113152bbed
Removed hp5400 series (now in hp5400.conf). Added Lexmark, Medion and Primax
...
scanners.
2003-02-26 14:31:38 +00:00
Henning Geinitz
1bbf2101e6
Added Visioneer OneTouch 8600.
2003-02-26 14:29:48 +00:00
Henning Geinitz
ccb0bbe80d
Added description for hp5400 backend. It supports the Hewlett-Packard 5400,
...
5470 and (maybe) 5490 scanners.
2003-02-26 14:25:46 +00:00
Stéphane Voltz
5ed8c99cb7
- changed 'gain' option name to 'brightness'
...
- changed 'highlight' option name to 'contrast'
2003-02-25 07:04:12 +00:00
Henning Geinitz
141a7159d9
Some parts concerning PRJECTS/.desc files are rewritten. Added information
...
about initializing global variables and sizeof (void *) != sizeof (int) (from
Martijn van Oosterhout <kleptog@svana.org>).
2003-02-24 21:16:44 +00:00
Henning Geinitz
d452194baa
Removed.
2003-02-24 21:06:31 +00:00
Henning Geinitz
47d5a76da0
Added documentation for ma1509 backend.
2003-02-24 21:05:18 +00:00
Frank Zago
d5a3bf7234
Added Mitsubishi to the list of vendors.
2003-02-22 19:45:24 +00:00
Frank Zago
3d92598acd
Added Relisys in the list of vendors. Bumped the revision date.
2003-02-22 18:43:45 +00:00
Henning Geinitz
3cf8377bee
Initialize global variables in sane_init.
2003-02-22 16:54:22 +00:00
Henning Geinitz
7e4fe2df10
Iniatialize global variables explicitely. Mention ma1509.
2003-02-22 16:48:02 +00:00
Henning Geinitz
8dedb6c862
Explicitely initialize global variables to avoid segfaults when calling
...
sane_init/sane_exit more than once.
2003-02-22 16:22:25 +00:00
Henning Geinitz
99a1cf050f
Add Ricoh IS-420.
2003-02-22 15:38:34 +00:00
Henning Geinitz
b0d7681738
Initialize global variables in sane_init to avoid segmentation faults when
...
sane_init/sane_exit is run more than once.
2003-02-22 15:37:19 +00:00
Henning Geinitz
a0251b6cc1
Added vid/pid 0x07b3/0x0400 to gt68xx.conf also. Added indormation about
...
Medion 4394. Mention ma1509 backend. Fix segfault when calling sane_open with
an empty device name.
2003-02-22 15:34:51 +00:00
Henning Geinitz
098f57adb0
Removed Fujitsu fi-4220C (now supported by fujitsu backend). Added Syscan
...
Travelscan 464. Updated HP scanners.
2003-02-20 18:18:44 +00:00
Oliver Schirrmeister
d74d4231ce
patch from <ron@roncemer.com>
...
fi4220 support
usb support
2003-02-20 13:33:07 +00:00
Henning Geinitz
f4ccae6565
Added Avision, Brother, and Umax scanners. Removed Mustek BearPaw 1200F.
2003-02-19 19:35:12 +00:00
Henning Geinitz
919fcac4c2
Added description of the ma1509 backend for Mustek BearPaw 1200F scanners.
2003-02-19 19:32:37 +00:00
Henning Geinitz
b9a6e5cc4a
Make sure that the result of the reader_process is interpreted
...
correctly. Block signals when waiting for a SCSI request to finish. Otherwise
we may get a segfault if the reader_process is terminated while waiting.
2003-02-17 12:05:56 +00:00
Henning Geinitz
57e852ea8a
List BearPaw 2400 CS Plus as supported. Make fast preview the default
...
(otherwise BP 2400 TA Plus wouldn't work with 12/16 bits). Added vid/pid
0x07b3/0x0400, that's another Plustek OpticPro 1248U.
2003-02-16 21:31:45 +00:00
Henning Geinitz
b92a3a30ef
Added Artec scanners.
2003-02-16 20:35:40 +00:00