Added documentation for ma1509 backend.
rodzic
747619ae5f
commit
47d5a76da0
|
@ -3,6 +3,8 @@
|
|||
* backend/Makefile.in backend/dll.conf backend/ma1509.c
|
||||
backend/ma1509.conf backend/ma1509.h: Added new backend ma1509 for
|
||||
Mustek BearPaw 1200F scanners.
|
||||
* doc/Makefile.in doc/descriptions/ma1509.desc doc/sane-ma1509.man
|
||||
doc/sane.man doc/.cvsignore: Added documentation for ma1509 backend.
|
||||
|
||||
2003-02-23 Simon Munton <simon@munton.demon.co.uk>
|
||||
* backend/pie.c: increment BUILD (was missed in last change)
|
||||
|
|
|
@ -50,7 +50,8 @@ SECT5 = sane-abaton.5 sane-agfafocus.5 sane-apple.5 sane-as6e.5 sane-dll.5 \
|
|||
sane-umax_pp.5 sane-umax1220u.5 sane-sm3600.5 sane-usb.5 \
|
||||
sane-mustek_usb.5 sane-sceptre.5 sane-canon_pp.5 sane-canon630u.5 \
|
||||
sane-teco1.5 sane-teco2.5 sane-teco3.5 sane-test.5 sane-sp15c.5 \
|
||||
sane-coolscan2.5 sane-hpsj5s.5 sane-gt68xx.5 sane-artec_eplus48u.5
|
||||
sane-coolscan2.5 sane-hpsj5s.5 sane-gt68xx.5 sane-artec_eplus48u.5 \
|
||||
sane-ma1509.5
|
||||
SECT7 = sane.7
|
||||
MANPAGES = $(SECT1) $(SECT5) $(SECT7)
|
||||
READMES = README AUTHORS COPYING ChangeLog LICENSE NEWS PROBLEMS \
|
||||
|
@ -88,7 +89,8 @@ DISTFILES = Makefile.in backend-writing.txt descriptions.txt \
|
|||
sane-umax_pp.man sane-usb.man sane-v4l.man sane.man sane.png \
|
||||
sane.tex saned.man scanimage.man sane-sceptre.man sane-canon_pp.man \
|
||||
sane-teco1.man sane-teco2.man sane-teco3.man sane-test.man sane-sp15c.man \
|
||||
sane-hpsj5s.man gamma4scanimage.man sane-gt68xx.man sane-artec_eplus48u.man
|
||||
sane-hpsj5s.man gamma4scanimage.man sane-gt68xx.man sane-artec_eplus48u.man \
|
||||
sane-ma1509.man
|
||||
|
||||
.PHONY: all clean depend dist distclean html html-man install \
|
||||
install-mostang sane-html uninstall
|
||||
|
|
|
@ -0,0 +1,39 @@
|
|||
; SANE Backend specification file
|
||||
;
|
||||
; It's basically emacs-lisp --- so ";" indicates comment to end of line.
|
||||
; All syntactic elements are keyword tokens, followed by a string or
|
||||
; keyword argument, as specified.
|
||||
;
|
||||
; ":backend" *must* be specified.
|
||||
; All other information is optional (but what good is the file without it?).
|
||||
;
|
||||
|
||||
:backend "ma1509" ; name of backend
|
||||
:version "1.0-2" ; version of backend
|
||||
:status :alpha ; :alpha, :beta, :stable, :new
|
||||
:manpage "sane-ma1509" ; name of manpage (if it exists)
|
||||
:url "http://www.meier-geinitz.de/sane/ma1509-backend/" ; backend's web page
|
||||
|
||||
:devicetype :scanner ; start of a list of devices....
|
||||
; other types: :stillcam, :vidcam,
|
||||
; :meta, :api
|
||||
|
||||
:mfg "Mustek" ; name a manufacturer
|
||||
:url "http://www.mustek.com/"
|
||||
:url "http://www.mustek.com.tw/"
|
||||
:url "http://www.mustek.de/"
|
||||
|
||||
:model "BearPaw 1200 F" ; name models for above-specified mfg.
|
||||
:interface "USB" ; interface type of the device:
|
||||
; "SCSI", "USB", "Parport (EPP)",
|
||||
; "Parport (SPP)", "Parport (ECP)",
|
||||
; "Serial port" or "Propretiary".
|
||||
:status :alpha
|
||||
:comment "Works upto 600 dpi. No support for TA and ADF yet."
|
||||
|
||||
|
||||
; :comment and :url specifiers are optional after :mfg, :model, :desc,
|
||||
; and at the top-level.
|
||||
|
||||
|
||||
|
|
@ -0,0 +1,134 @@
|
|||
.TH sane-ma1509 5 "24 Feb 2003" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
||||
.IX sane-ma1509
|
||||
.SH NAME
|
||||
sane-ma1509 \- SANE backend for Mustek BearPaw 1200F USB scanner
|
||||
.SH DESCRIPTION
|
||||
The
|
||||
.B sane-ma1509
|
||||
library implements a SANE (Scanner Access Now Easy) backend that provides
|
||||
access to the Mustek BearPaw 1200F USB flatbed scanner. This scanner is based
|
||||
on the MA-1509 chipset. Other scanners that use this chip (if they exist) may
|
||||
also work.
|
||||
.PP
|
||||
This backend is ALPHA software. Be careful and remove the power plug
|
||||
immediately if your hear unusual noises.
|
||||
.PP
|
||||
More details can be found on the ma1509 backend homepage
|
||||
.IR http://www.meier-geinitz.de/sane/ma1509-backend/ .
|
||||
.PP
|
||||
Other Mustek USB scanners are supported by the gt68xx, mustek_usb and the
|
||||
plustek backends. See
|
||||
.BR sane-mustek_usb (5),
|
||||
.BR sane-gt68xx (5)
|
||||
and
|
||||
.BR sane-plustek (5)
|
||||
for details.
|
||||
.PP
|
||||
This backend can only work with scanners that are already detected by the
|
||||
operating system. See
|
||||
.BR sane-usb (5)
|
||||
for details.
|
||||
.PP
|
||||
If you own a scanner other than the Mustek BearPaw 1200F that works with this
|
||||
backend, please let me know this by sending the scanner's exact model name and
|
||||
the USB vendor and device ids (e.g. from
|
||||
.I /proc/bus/usb/devices
|
||||
or syslog) to me.
|
||||
|
||||
.SH "DEVICE NAMES"
|
||||
This backend expects device names of the form:
|
||||
.PP
|
||||
.RS
|
||||
.I special
|
||||
.RE
|
||||
.PP
|
||||
Where
|
||||
.I special
|
||||
is a path-name for the special device that corresponds to a USB scanner.
|
||||
With Linux, such a device name could be
|
||||
.I /dev/usb/scanner0
|
||||
or
|
||||
.IR libusb:001:002 ,
|
||||
for example.
|
||||
.PP
|
||||
|
||||
.SH CONFIGURATION
|
||||
The contents of the
|
||||
.I ma1509.conf
|
||||
file is a list of options and device names that correspond to Mustek BearPAw
|
||||
1200F scanners. Empty lines and lines starting with a hash mark (#) are
|
||||
ignored.
|
||||
.PP
|
||||
Instead of using the device name, the scanner can be autodetected by
|
||||
.B "usb vendor_id product_id"
|
||||
statements which are already included into
|
||||
.IR ma1509.conf .
|
||||
This is only supported with Linux 2.4.8 and higher and all systems that
|
||||
support libsub. "vendor_id" and "product_id" are hexadecimal numbers that
|
||||
identfy the scanner. If this doesn't work, a device name must be placed in
|
||||
.I ma1509.conf
|
||||
as described above.
|
||||
.PP
|
||||
To set the time the lamp needs for warm-up, use
|
||||
.B option
|
||||
.B warmup-time
|
||||
in
|
||||
.IR ma1509.conf .
|
||||
The time is given in seconds after the option. The default is 30 seconds.
|
||||
.SH FILES
|
||||
.TP
|
||||
.I @CONFIGDIR@/ma1509.conf
|
||||
The backend configuration file (see also description of
|
||||
.B SANE_CONFIG_DIR
|
||||
below).
|
||||
.TP
|
||||
.I @LIBDIR@/libsane-ma1509.a
|
||||
The static library implementing this backend.
|
||||
.TP
|
||||
.I @LIBDIR@/libsane-ma1509.so
|
||||
The shared library implementing this backend (present on systems that
|
||||
support dynamic loading).
|
||||
.SH ENVIRONMENT
|
||||
.TP
|
||||
.B SANE_CONFIG_DIR
|
||||
This environment variable specifies the list of directories that may
|
||||
contain the configuration file. Under UNIX, the directories are
|
||||
separated by a colon (`:'), under OS/2, they are separated by a
|
||||
semi-colon (`;'). If this variable is not set, the configuration file
|
||||
is searched in two default directories: first, the current working
|
||||
directory (".") and then in @CONFIGDIR@. If the value of the
|
||||
environment variable ends with the directory separator character, then
|
||||
the default directories are searched after the explicitly specified
|
||||
directories. For example, setting
|
||||
.B SANE_CONFIG_DIR
|
||||
to "/tmp/config:" would result in directories "tmp/config", ".", and
|
||||
"@CONFIGDIR@" being searched (in this order).
|
||||
.TP
|
||||
.B SANE_DEBUG_MA1509
|
||||
If the library was compiled with debug support enabled, this
|
||||
environment variable controls the debug level for this backend. Higher
|
||||
debug levels increase the verbosity of the output.
|
||||
|
||||
.SH "SEE ALSO"
|
||||
.BR sane (7),
|
||||
.BR sane-usb (5),
|
||||
.BR sane-gt68xx (5),
|
||||
.BR sane-plustek (5),
|
||||
.BR sane-mustek_usb (5),
|
||||
.BR sane-mustek (5),
|
||||
.BR sane-mustek_pp (5),
|
||||
.br
|
||||
.I http://www.meier-geinitz.de/sane/ma1509-backend/
|
||||
|
||||
.SH AUTHOR
|
||||
Henning Meier-Geinitz <henning@meier-geinitz.de>
|
||||
|
||||
.SH BUGS
|
||||
Resolutions higher than 600 dpi don't work
|
||||
.br
|
||||
Transparency adapter and automatic document feeder is not supported yet
|
||||
.br
|
||||
No support for "high-speed" mode (jpeg)
|
||||
.PP
|
||||
More detailed bug information is available at the MA-1509 backend homepage
|
||||
.IR http://www.meier-geinitz.de/sane/ma1509-backend/ .
|
|
@ -1,4 +1,4 @@
|
|||
.TH sane 7 "Nov 22th, 2002" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
||||
.TH sane 7 "Feb 24th, 2003" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
||||
.IX sane
|
||||
|
||||
.SH NAME
|
||||
|
@ -279,6 +279,11 @@ LEO FS-1130 scanner. See
|
|||
.BR sane-leo (5)
|
||||
for details.
|
||||
.TP
|
||||
.B ma1509
|
||||
The ma1509 backend supports the Mustek BearPaw 1200F USB flatbed scanner. See
|
||||
.BR sane-ma1509 (5)
|
||||
for details.
|
||||
.TP
|
||||
.B matsushita
|
||||
This backend supports some Panasonic KVSS high speed scanners. See
|
||||
.BR sane-matsushita (5)
|
||||
|
|