kopia lustrzana https://gitlab.com/sane-project/backends
Updated Mustek BearPaw 1200 CU Plus white strip value. Set Mustek ScanExpress
A3 USB to CCD. Black mark may be still wrong. Minor formatting changes in the manpage. Decreased ScanExpress A3 USB status to alpha because of CIS/CCD change.merge-requests/1/head
rodzic
04dd7d101f
commit
eda0c4bc5e
|
@ -1,3 +1,12 @@
|
|||
2003-04-11 Henning Meier-Geinitz <henning@meier-geinitz.de>
|
||||
|
||||
* backend/gt68xx.c backend/gt68xx_devices.c doc/sane-gt68xx.man
|
||||
doc/descriptions/gt68xx.desc doc/gt68xx/gt68xx.CHANGES: Updated
|
||||
Mustek BearPaw 1200 CU Plus white strip value. Set Mustek
|
||||
ScanExpress A3 USB to CCD. Black mark may be still wrong. Minor
|
||||
formatting changes in the manpage. Decreased ScanExpress A3 USB
|
||||
status to alpha because of CIS/CCD change.
|
||||
|
||||
2003-04-10 Henning Meier-Geinitz <henning@meier-geinitz.de>
|
||||
|
||||
* backend/test.c backend/test.h doc/descriptions/test.desc: Added
|
||||
|
|
|
@ -48,7 +48,7 @@
|
|||
|
||||
#include "../include/sane/config.h"
|
||||
|
||||
#define BUILD 44
|
||||
#define BUILD 45
|
||||
#define MAX_DEBUG
|
||||
#define WARMUP_TIME 30
|
||||
#define CALIBRATION_HEIGHT 2.5
|
||||
|
|
|
@ -337,7 +337,7 @@ static GT68xx_Model mustek_1200cuplus_model = {
|
|||
SANE_FIX (217.0), /* Size of scan area in mm (x) */
|
||||
SANE_FIX (299.0), /* Size of scan area in mm (y) */
|
||||
|
||||
SANE_FIX (5.0), /* Start of white strip in mm (y) */
|
||||
SANE_FIX (9.0), /* Start of white strip in mm (y) */
|
||||
SANE_FIX (0.0), /* Start of black mark in mm (x) */
|
||||
|
||||
SANE_FIX (0.0), /* Start of scan area in TA mode in mm (x) */
|
||||
|
@ -357,7 +357,7 @@ static GT68xx_Model mustek_1200cuplus_model = {
|
|||
|
||||
SANE_TRUE, /* Is this a CIS scanner? */
|
||||
GT68XX_FLAG_NO_STOP /* Which flags are needed for this scanner? */
|
||||
/* Everything untested */
|
||||
/* Tested by Hamersky Robert r.hamersky at utanet.at */
|
||||
};
|
||||
|
||||
static GT68xx_Model mustek_2400cuplus_model = {
|
||||
|
@ -701,9 +701,10 @@ static GT68xx_Model mustek_a3usb_model = {
|
|||
{0x157, 0x157, 0x157}, /* Default exposure parameters */
|
||||
SANE_FIX (2.0), /* Default gamma value */
|
||||
|
||||
SANE_TRUE, /* Is this a CIS scanner? */
|
||||
SANE_FALSE, /* Is this a CIS scanner? */
|
||||
0 /* Which flags are needed for this scanner? */
|
||||
/* Tested by Pedro Morais <morais@inocam.com> */
|
||||
/* Tested by Pedro Morais <morais@inocam.com>, changes to CCD by hmg, white
|
||||
strip/black mark untested */
|
||||
};
|
||||
|
||||
static GT68xx_Model lexmark_x73_model = {
|
||||
|
|
|
@ -1,6 +1,6 @@
|
|||
:backend "gt68xx"
|
||||
:status :beta
|
||||
:version "1.0-44"
|
||||
:version "1.0-45"
|
||||
:manpage "sane-gt68xx"
|
||||
:url "http://www.meier-geinitz.de/sane/gt68xx-backend/"
|
||||
:comment "Only the USB scanners mentioned below are supported. For other Mustek BearPaws, look at the Plustek and the MA-1509 backend."
|
||||
|
@ -64,8 +64,8 @@
|
|||
|
||||
:model "ScanExpress A3 USB"
|
||||
:interface "USB"
|
||||
:status :beta
|
||||
;:comment ""
|
||||
:status :alpha
|
||||
:comment "Calibration may be wrong. Please contact me if you have such a device."
|
||||
|
||||
:model "ScanExpress 2400 USB"
|
||||
:interface "USB"
|
||||
|
@ -97,9 +97,9 @@
|
|||
:comment "works, only product id 0x4002 is supported"
|
||||
|
||||
:model "Ultima 2000 e+"
|
||||
:status :untested
|
||||
:status :alpha
|
||||
:interface "USB"
|
||||
:comment "Testers welcome"
|
||||
:comment "works, only limited testing until now"
|
||||
|
||||
|
||||
:mfg "Boeder"
|
||||
|
|
|
@ -1,5 +1,12 @@
|
|||
gt68xx.CHANGES -*-text-*-
|
||||
|
||||
V 1.0-45 (2003-04-11)
|
||||
|
||||
- Updated Mustek BearPaw 1200 CU Plus white strip value.
|
||||
- Set Mustek ScanExpress A3 USB to CCD. Black mark may be still wrong.
|
||||
- Minor formatting changes in the manpage.
|
||||
- Decreased ScanExpress A3 USB status to alpha because of CIS/CCD change.
|
||||
|
||||
V 1.0-44 (2003-03-13)
|
||||
|
||||
- Added Packard Bell Diamond 1200 Plus to .desc and manpage.
|
||||
|
|
|
@ -62,7 +62,7 @@ More details can be found on the gt68xx backend homepage
|
|||
.IR http://www.meier-geinitz.de/sane/gt68xx/ .
|
||||
.PP
|
||||
The Artec E+ 48U and its clones are supported by the artec_eplus48u backend, see
|
||||
.BR sane-artec_eplus48u (5)
|
||||
.BR sane\-artec_eplus48u (5)
|
||||
for details.
|
||||
.PP
|
||||
This is BETA software. Especially if you test new or untested scanners, keep
|
||||
|
@ -81,7 +81,7 @@ the models mentioned above, please let me know.
|
|||
If libusb-0.1.6 or later is installed, this section can be skipped. The
|
||||
scanner should be found by sane-find-scanner without further actions. For
|
||||
setting permissions and general USB information looks at
|
||||
.BR sane-usb (5).
|
||||
.BR sane\-usb (5).
|
||||
.PP
|
||||
The scanners based on the GT-6816 (Mustek BearPaw TA and BearPaw Plus models,
|
||||
the Packard Bell and the Lexmark scanner) need a Linux kernel 2.4.12 or newer.
|
||||
|
@ -236,13 +236,13 @@ export SANE_DEBUG_GT68XX=4
|
|||
|
||||
.SH "SEE ALSO"
|
||||
.BR sane (7),
|
||||
.BR sane-usb (5),
|
||||
.BR sane-artec_eplus48u (5)
|
||||
.BR sane-plustek (5),
|
||||
.BR sane-ma1509 (5),
|
||||
.BR sane-mustek_usb (5),
|
||||
.BR sane-mustek (5),
|
||||
.BR sane-mustek_pp (5)
|
||||
.BR sane\-usb (5),
|
||||
.BR sane\-artec_eplus48u (5)
|
||||
.BR sane\-plustek (5),
|
||||
.BR sane\-ma1509 (5),
|
||||
.BR sane\-mustek_usb (5),
|
||||
.BR sane\-mustek (5),
|
||||
.BR sane\-mustek_pp (5)
|
||||
.br
|
||||
.I @DOCDIR@/gt68xx/gt68xx.CHANGES
|
||||
.br
|
||||
|
|
Ładowanie…
Reference in New Issue