help the SANE project. Added comments about possible problems
with old installaitions of SANE and /etc/ld.so.conf. Added section
"REPORTING BUGS".
Henning Meier-Geinitz <henning@meier-geinitz.de>
Generate sane-backends.html in doc/. New target: install-mostang.
Installs the sane standard (.ps, .ps.gz and html), the html manpages,
and sane-backends.html on www.mostang.com.
* PROJECTS: Added entry for the Fujitsu M3091DCd. Updated my email
address.
* TODO: Added entry for the Fujitsu M3091DCd and a combined Fujitsu
backend. Clarified that "printf" also shouldn't be used.
* backend/dll.desc: Added my email as contact address.
* backend/m3091.desc: New file for the Fujitsu M3091DCd.
* doc/sane-mustek.man: Updated URL.
* backend/mustek.CHANGES backend/umax.CHANGES backend/umax.FAQ
backend/umax.TODO: Moved to doc/mustek respectively doc/umax.
* doc/canon.CHANGES doc/canon.install2700F.txt doc/canon:
Moved canon-specific documentation to doc/canon.
* doc/mustek: New subdirectory for mustek-specific documentation.
* doc/sane-umax*.html doc/sane-umax*.jpg doc/sane-umax-doc.tex
doc/sane-umax-doc.dvi doc/umax: Moved all the umax-specific
documentation to new subdirectory umax.
* PROBLEMS: Point to pnm/saned security risks.
* TODO: Removed the entries about epson usb mis-detection and check
for installed sane versions.
* configure configure.in backend/Makefile.in: Added detection of older
versions of SANE. The pnm backend is now disabled by default.
* backend/dll.c backend/dll.desc: Fixed file descriptor leak (found by
Douglas Gilbert). New version: 1.0.2.
* backend/net.desc: Added Jochen Eisinger's email address as contact
for the net backend.
* doc/sane-pnm.man: Point to pnm/saned security risks.
* README: Updated xsane link.
* configure configure.in backend/dll.c backend/dll.desc
backend/net.c backend/net.desc include/sane/config.h.in
Yet another change in the version system for dll and net.
For sane_init return the version of the package but use
own internal version number in the source (printed with
debugging enabled) and in *.desc. The internal versions
of both net and dll are set to 1.0.1. Please increase the
build number with every change on the source files.
* doc/realeases.txt -> doc/releases.txt. Fixed spelling error.
Added entries about sane-backends.html, sane.ps, man pages,
platforms page.
* PROJECTS TODO: Added entry about E3 USB chipset.
* backend/dll.c backend/dll.desc: New version is 1.0.5. Version and
PACKAGE_VERSION is printed with debug level set to 1 or higher.
The version numbers of all backends that are loaded are printed
at debug level 3 or higher. Print error if backend with wrong
major version number is loaded. Some standardization changes
concerning the DBG messages.
* backend/net.c backend/net.desc: New version is 1.0.5. Version and
PACKAGE_VERSION is printed with debug level set to 1 or higher.
Some standardization changes concerning the DBG messages.
* backend/pnm.c: Return SANE_INFO_RELOAD_PARAMS even if the pnm
file doesn't exist or can't be loaded (from mh <crapsite@gmx.net>).
* doc/backend-writing.txt: Added AUTHORS to the list of things that
should be updated when including a new backend. Added points about
avoiding printf and exit in backends.
* doc/releases.txt: New file. This text summarizes some points to
pay attention to when a new release of sane-backends is made.
Additions and corrections are appreciated.
* doc/scanimage.man: Add some more information about the -V option.
* frontend/scanimage.c: The option -V now also prints the version of
the backend (ususally dll).
* backend/mustek.c backend/mustek.desc backend/mustek.CHANGES
Added detection of the TA for the Paragon 1200 SP Pro. Added
warning about not supported Trust scanners. Changed description
of contarst and brightness settings. Backend status is "stable"
now. New version: 1.0-106.
* acinclude.m4 aclocal.m4: Fixed comment concerning dc240.
* configure configure.in include/sane/config.h.in: Added test for
socklen_t in sys/socket.h. This fixes the compilation problem on
Irix.
* doc/sane-avision.man doc/sane-ricoh.man doc/sane-s9036.man
doc/sane-tamarack.man: find-scanner is now called
sane-find-scanner and installed on the system so it's not
necessary to point to the tools directory.
* frontend/scanimage.c: Fixed too long line in output.
* sane-config.in: Name is sane-config again (was sane-backends-config
due to the renaming of the package).
* TODO: Removed entry about net.c not compiling on Irix and
references to find-scanner in the man pages. Updated numbers of
the compilation warnings. Still too many, however.
* backend/sc240.c backend/dc240.h backend/dc240.conf
backend/dc240.desc backend/dll.conf doc/sane-dc240.man:
Added dc240 backend for the Kodak DC240 Digital camera (from
Peter Fales <peter@fales.com>).
* doc/Makefile.in: Added sane-dc240 in section 5.
* backend/Makefile.in: Added dc240.
* configure configure.in: If the jpeg libs are not available,
dc240 is also disabled.
* AUTHORS: Added entry for dc240 and updated email address of
Peter Fales.
* NEWS: First version of the news entry for 1.0.5.
* PROJECTS: Removed dc240. Added Microrec ScanMaker 3600.
* README: Added dc240.
* TODO: Removed dc240. Added entry about keep-alive mechanism in saned.
* sane-backends.lsm: Added dc240.
* testsuite/.cvsignore: New file. Added entry for Makefile.
* backend/bh.c backend/bh.h doc/sane-bh.man
added support for Copiscan 8000 series by Mark Temple
added options deskew and rotation
inquiry compares product to COPISCAN rather than COPISCAN II
* backend/bh.c backend/bh.conf backend/bh.h doc/sane-bh.man
Added new backend Bell and Howell Copiscan scanners
* backend/bh.desc
Updated version from (0.1) to 1.0-4
Referenced manpage
* backend/Makefile.in
Added bh to PRELOADABLE_BACKENDS
Added libsane-bh.la dependencies
* doc/Makefile.in
Added sane-bh.5 to SECT5
* backend/mustek.c backend/mustek.desc backend/mustek.h
backend/mustek.CHANGES doc/sane-mustek.man:
Added 36 bit mode for Pro models. Removed support for "special"
modes, used options instead. Code cleanup. Updated manpage
concerning sane-find-scanner. New version: 1.0-104.
* configure: regenerated from configure.in.
* tools/find-scanner.c: Removed. Now called sane-find-scanner.
* tools/sane-find-scanner: New file (was find-scanner).
* tools/.cvsignore tools/Makefile.in tools/README: Updated because
of name change. sane-find-scanner is installed now.
* README README.linux: Updated because of sane-find-scanner.
* frontend/scanimage.man: Updated because of sane-find-scanner.
* doc/sane-find-scanner.man: New file.
* doc/.cvsignore doc/Makefile.in: Added sane-find-scanner(1).
* TODO: Updated concerning sane-find-scanner. Added entry about
qcam /tmp file handling. Some spelling corrections.
* backend/mustek.CHANGES backend/mustek.c backend/mustek.desc
backend/mustek.h doc/sane-mustek.man: Added calibration for Pro
scanners and the SE 12000 SP Plus. Added option to use the full
legal size of the Paragon 1200 LS scanner. Added fast preview for
Pro scanners. Bug fixes. New version: 1.0-103.
* NEWS: Added date of release.
* TODO: Removed entries about PATH_MAX, sanei_scsi_find_devices, and
shm.h. Added entry about the necessity to check HAVE_SYS_SHM_H.
* configure configure.in include/sane/config.h.in: Default to
--enable-warnings again. Don't set "-ansi" for OS/2. Test for
sys/shm.h.
* backend/GUIDE: Moved to doc/backend-writing.txt.
* doc/backend-writing.txt: New file (moved from backend/GUIDE).
Added comments about sanei-backend.h and PATH_MAX.
* include/sane/sanei_backend.h: Added define for PATH_MAX (if
necessary).
* sanei/sanei_scsi.c: Implemented sanei_scsi_find_devices for FreeBSD
(from ports@FreeBSD.org).
* tools/Makefile.in: Use INSTALL_SCRIPT instead of INSTALL_PROGRAM for
sane-config (from ports@FreeBSD.org).
* doc/sane-scsi.man: Small changes/updates concerning Linux
2.2. Updated entries about Adaptec cards, NCR53c400/Domex 3181
cards, NCR 810 cards. Removed direct links to some backends.
* doc/sane-snapscan.man: Added link to new snapscan website.
* AUTHORS: Added Karsten Festag as maintainer of microtek2.
* backend/mustek.* doc/sane-mustek.man: Update to Mustek backend
1.0-100. Added option fast-preview that tries to use the fastest
mode available for preview. This is supported for the 3-pass
scanners (was option "preview in gray") and some of the
ScanExpress scanners (6000 SP, 12000 SP Plus). Use #include
"../include/sane/...". Put option force-wait into mustek.conf
(disabled). Removed block mode for Paragon 6000 SP and 8000 SP.
Code cleanup. More debug output. Details in backend/mustek.CHANGES.
* doc/.cvsignore: Added sane-as6e.5 and sane-nec.5.
* AUTHORS: Removed authors of xscanimage and xcam (now in
sane-frontends).
* README.unixware2, README.unixware7: X-frontends are no longer
included. Removed comments and sourcecode of "rev" (not supported/used
in backends/Makefile anymore).
* sane.lsm: X-frontends are no longer included. Used blanks instead of
tabs.
* doc/scanimage.man: Removed links to backends, added generic link
instead.
* doc/.cvsignore frontend/.cvsignore: X-frontends are no longer included.
* doc/scanimage.man doc/saned.man: updated description of password
file
* sanei/sanei_auth.c frontend/saned.c frontend/scanimage.c: replaced
index() by strchr(). Changed style of password file
* backend/net.c: the net backend now prepends net:host: to the
resource before calling the auth_callback function
* AUTHORS: Added FUKUDA Kazuya for the nec Backend. Used spaces instead
of tabs.
* PROJECTS: Removed entry about NEC. Added/updated entries about Mustek
USB scanners.
* README: Added link to sane-nec(5).
* TODO: Removed entries about sanei_authorize and plain text passwords.
* backend/Makefile.in backend/dll.conf backend/nec.conf backend/nec.c
backend/nec.desc backend/nec.h doc/Makefile.in doc/sane-nec.man:
Added nec backend for the NEC scanners PC-IN500/4C (from Kazuya Fukuda
<fukuda@pjs.nevt.nec.co.jp>)
* configure configure.in: Added test for /dev/urandom and
index() in string.h or strings.h
* backend/net.c: Fixed SANE_NET_AUTHORIZE call handling
* doc/net.tex: Clarified definition of SANE_NET_AUTHORIZE, added
definition of MD5 authorization
* doc/sane.tex: Upgraded to version 1.0.2, changed definition of
SANE_MAX_USERNAME_LEN & SANE_MAX_PASSWORD_LEN to 128 chars
* doc/saned.man: added description of SANE_CONFIG_DIR/saned.users
* doc/scanimage.man: added description of ~/.sane/pass and
--accept-md5-only
* frontend/saned.c: implemented user authorization on a per backend
basis
* frontend/scanimage.c: fixed bug (option -b wasn't present)
implemented auth_callback
* include/sane/sane.h: changed definition of SANE_MAX_USERNAME_LEN &
SANE_MAX_PASSWORD_LEN to 128 chars
* lib/Makefile.in sanei/Makefile.in: updated Makefiles