kopia lustrzana https://gitlab.com/sane-project/backends
2001-04-30 Jochen Eisinger <jochen.eisinger@informatik.uni-freiburg.de>
* doc/sane-mustek_pp.man: Added information about CIS patches by Eddy De GreefDEVEL_2_0_BRANCH-1
rodzic
1af3146faa
commit
13bc8892af
|
@ -1,4 +1,4 @@
|
|||
.TH sane-mustek_pp 5 "30 September 2000"
|
||||
.TH sane-mustek_pp 5 "21 April 2001"
|
||||
.IX sane-mustek_pp
|
||||
.SH NAME
|
||||
sane-mustek_pp - SANE backend for Mustek parallel port flatbed scanners
|
||||
|
@ -24,9 +24,9 @@ SM 1200 ED Plus 1015 01 partly
|
|||
.br
|
||||
SE 12000 P 1505 05 no
|
||||
.br
|
||||
SE 600 CP 1015 00 no
|
||||
SE 600 CP 1015 00 no (*)
|
||||
.br
|
||||
SM 600 CP 1015 00 no
|
||||
SM 600 CP 1015 00 no (*)
|
||||
.br
|
||||
600 III EP Plus 1013/1015 00/01 yes
|
||||
.br
|
||||
|
@ -40,11 +40,16 @@ Gallery 4800 ???? ?? yes
|
|||
.br
|
||||
Viviscan Compact II 1013 00 yes
|
||||
.br
|
||||
MD985x 1015 01/05 no
|
||||
MD985x 1015 01/05 no (*)
|
||||
.br
|
||||
LT9891 1015 01 no
|
||||
LT9891 1015 01 no (*)
|
||||
.RE
|
||||
.PP
|
||||
(*) These scanners are currently not supported by the default driver,
|
||||
but patches are available; see
|
||||
.B CIS
|
||||
.BR Scanners .
|
||||
.PP
|
||||
Please note that this backend is still under construction. I don't know
|
||||
which scanners work or which will work in future releases.
|
||||
.PP
|
||||
|
@ -351,10 +356,50 @@ port 0x378
|
|||
|
||||
.SH CIS Scanners
|
||||
|
||||
Some Mustek Scanners use so called contact image sensors instead of CCDs (cold cathode devices). This scanners have a totally different protcol: although the seem to work they are far from being supported.
|
||||
Some Mustek Scanners use so called contact image sensors (CIS) instead of
|
||||
cold cathode devices (CCD). These scanners have a totally different
|
||||
protocol; they are currently not supported by the default driver.
|
||||
.PP
|
||||
Check out the homepage of Eddy De Greef for some patches for CIS...
|
||||
|
||||
However, patches are available that support most of the CIS type scanners.
|
||||
Check out the homepage of Eddy De Greef for these patches (see the
|
||||
.B SEE ALSO
|
||||
section).
|
||||
.PP
|
||||
These patches have been reported to work on the Mustek 600CP, 1200CP,
|
||||
and 1200CP+ models, and various OEM versions (LifeTec/Medion 9350, 9351,
|
||||
9850, 9851, 9858, 9890, and 9891; Trust Easy Connect 9600 plus;
|
||||
Targa Funline TS12EP).
|
||||
.PP
|
||||
When installing these patches, 3 additional options are available in the
|
||||
.B mustek_pp.conf
|
||||
configuration file (see
|
||||
.BR CONFIGURATION ):
|
||||
.BR cis600 ,
|
||||
.BR cis1200 ,
|
||||
.BR cis1200+ .
|
||||
.PP
|
||||
These options select the 600CP, 1200CP, or 1200CP+ version of the driver.
|
||||
One of them must be set.
|
||||
.PP
|
||||
The 600CP has a maximum resolution of 300x600 DPI, whereas the 1200CP
|
||||
and 1200CP+ have a maximum resolution of 600x1200 DPI. The option must
|
||||
match your scanner. If unsure, check the manual or the box.
|
||||
.br
|
||||
.B Choosing the wrong option could damage your scanner!
|
||||
.B Especially, using the 1200CP settings on a 600CP can be harmful.
|
||||
.B If the scanner starts making a loud noice, turn it off immediately !!!
|
||||
.PP
|
||||
The
|
||||
.B cis...
|
||||
options cannot be combined with the
|
||||
.BR use600
|
||||
option.
|
||||
.PP
|
||||
Currently, when installing the CIS patches, support for CCD type scanners is
|
||||
disabled. In future versions of the
|
||||
.B sane-mustek_pp
|
||||
backend, the CIS patches will be integrated and support for both types
|
||||
of scanners will co-exist.
|
||||
.SH FILES
|
||||
.TP
|
||||
.I @CONFIGDIR@/mustek_pp.conf
|
||||
|
|
Ładowanie…
Reference in New Issue