2001-01-17 Henning Meier-Geinitz <hmg@gmx.de>

* backend/mustek.c backend/mustek.desc backend/mustek.h
	  backend/mustek.CHANGES doc/sane-mustek.man:
	  Added 36 bit mode for Pro models. Removed support for "special"
	  modes, used options instead. Code cleanup. Updated manpage
	  concerning sane-find-scanner. New version: 1.0-104.
	* configure: regenerated from configure.in.
DEVEL_2_0_BRANCH-1
Henning Geinitz 2001-01-17 19:05:42 +00:00
rodzic f406a1bc40
commit 682d9ae42c
4 zmienionych plików z 26 dodań i 11 usunięć

Wyświetl plik

@ -1,5 +1,23 @@
CHANGES for the SANE Mustek backend
2001-01-17
* Pro: Do calibration only in Lineart, Gray and Color 24 modes.
2001-01-03
* Added 36 bit color mode for the Paragon Pro scanners.
2000-12-31
* Added function little_endian (from coolscan.c) to check the endianess of
the current architecture (needed for 16 bit frames).
* Added option for Gray fast
* Added option for bit depth (8 and 12 bits for the Pro models)
* Removed "special" modes from mode option
* Removed 48 bit options for the SE Plus. This mode seems to use only
interpolated information (but I may be wrong).
2000-12-31
* Released Mustek backend 1.0-103
2000-12-30
* Implemented calibration (color and gray mode) for the Paragon 1200 Pro.
It's not perfect and needs lots of tests. It may work for the Paragon

Wyświetl plik

@ -9,7 +9,7 @@
;
:backend "mustek" ; name of backend
:version "1.0-103" ; version of backend
:version "1.0-104" ; version of backend
:status :beta ; :alpha, :beta, :stable, :new
:manpage "sane-mustek" ; name of manpage (if it exists)
:url "http://hmg.home.pages.de/sane/"

Wyświetl plik

@ -97,8 +97,6 @@
#define MUSTEK_MODE_GRAY (1 << 1) /* grayscale 8 bits / pixel */
#define MUSTEK_MODE_COLOR (1 << 2) /* color 24 bits / pixel */
#define MUSTEK_MODE_HALFTONE (1 << 3) /* use dithering */
#define MUSTEK_MODE_GRAY_FAST (1 << 4) /* Pro series fast grayscale */
#define MUSTEK_MODE_COLOR_48 (1 << 5) /* color 48 bits / pixel */
/* Color band codes: */
#define MUSTEK_CODE_GRAY 0
@ -158,7 +156,9 @@ enum Mustek_Option
OPT_MODE_GROUP,
OPT_MODE,
OPT_FAST_GRAY_MODE,
OPT_RESOLUTION,
OPT_BIT_DEPTH,
OPT_SPEED,
OPT_SOURCE,
OPT_PREVIEW,
@ -241,7 +241,6 @@ typedef struct Mustek_Device
SANE_Int firmware_format;
/* firmware revision system: 0 = old, x.yz; 1 = new, Vxyz */
SANE_Int firmware_revision_system;
/* For SE scanners: which resolutions are allowed in color mode */
}
Mustek_Device;

Wyświetl plik

@ -1,4 +1,4 @@
.TH sane-mustek 5 "19 Nov 2000"
.TH sane-mustek 5 "31 Dec 2000"
.IX sane-mustek
.SH NAME
sane-mustek - SANE backend for Mustek flatbed scanners
@ -97,10 +97,8 @@ SCSI scanner or the port number at which the 600 II N can
be found (see section PARAGON 600 II N below). For SCSI
scanners, the special device name must be a generic SCSI device or a
symlink to such a device. The program
.IR find-scanner
helps to find out the correct device. It can be found in the
.IR tools
directory of the SANE distribution. Under Linux, such a device name
.IR sane-find-scanner
helps to find out the correct device. Under Linux, such a device name
could be
.I /dev/sga
or
@ -332,7 +330,7 @@ Example:
export SANE_DEBUG_MUSTEK=4
.SH "SEE ALSO"
sane\-scsi(5), sane-mustek_pp(5)
sane-find-scanner(1), sane\-scsi(5), sane-mustek_pp(5)
.SH AUTHOR
David Mosberger, Andreas Czechanowski, Andreas Bolsch (SE extensions),
Henning Meier-Geinitz
@ -342,7 +340,7 @@ high resolutions and wide scanareas.
Only 1, 8 and 24 bit modes are supported until now.
Calibration doesn't work yet.
Calibration doesn't work correctly for all scanners.
Some scanners (e.g. Paragon 1200 A3 + Pro, SE A3) need more testing.