2001-01-17 Henning Meier-Geinitz <hmg@gmx.de>
* backend/mustek.c backend/mustek.desc backend/mustek.h backend/mustek.CHANGES doc/sane-mustek.man: Added 36 bit mode for Pro models. Removed support for "special" modes, used options instead. Code cleanup. Updated manpage concerning sane-find-scanner. New version: 1.0-104. * configure: regenerated from configure.in.DEVEL_2_0_BRANCH-1
rodzic
f406a1bc40
commit
682d9ae42c
|
@ -1,5 +1,23 @@
|
|||
CHANGES for the SANE Mustek backend
|
||||
|
||||
2001-01-17
|
||||
* Pro: Do calibration only in Lineart, Gray and Color 24 modes.
|
||||
|
||||
2001-01-03
|
||||
* Added 36 bit color mode for the Paragon Pro scanners.
|
||||
|
||||
2000-12-31
|
||||
* Added function little_endian (from coolscan.c) to check the endianess of
|
||||
the current architecture (needed for 16 bit frames).
|
||||
* Added option for Gray fast
|
||||
* Added option for bit depth (8 and 12 bits for the Pro models)
|
||||
* Removed "special" modes from mode option
|
||||
* Removed 48 bit options for the SE Plus. This mode seems to use only
|
||||
interpolated information (but I may be wrong).
|
||||
|
||||
2000-12-31
|
||||
* Released Mustek backend 1.0-103
|
||||
|
||||
2000-12-30
|
||||
* Implemented calibration (color and gray mode) for the Paragon 1200 Pro.
|
||||
It's not perfect and needs lots of tests. It may work for the Paragon
|
||||
|
|
|
@ -9,7 +9,7 @@
|
|||
;
|
||||
|
||||
:backend "mustek" ; name of backend
|
||||
:version "1.0-103" ; version of backend
|
||||
:version "1.0-104" ; version of backend
|
||||
:status :beta ; :alpha, :beta, :stable, :new
|
||||
:manpage "sane-mustek" ; name of manpage (if it exists)
|
||||
:url "http://hmg.home.pages.de/sane/"
|
||||
|
|
|
@ -97,8 +97,6 @@
|
|||
#define MUSTEK_MODE_GRAY (1 << 1) /* grayscale 8 bits / pixel */
|
||||
#define MUSTEK_MODE_COLOR (1 << 2) /* color 24 bits / pixel */
|
||||
#define MUSTEK_MODE_HALFTONE (1 << 3) /* use dithering */
|
||||
#define MUSTEK_MODE_GRAY_FAST (1 << 4) /* Pro series fast grayscale */
|
||||
#define MUSTEK_MODE_COLOR_48 (1 << 5) /* color 48 bits / pixel */
|
||||
|
||||
/* Color band codes: */
|
||||
#define MUSTEK_CODE_GRAY 0
|
||||
|
@ -158,7 +156,9 @@ enum Mustek_Option
|
|||
|
||||
OPT_MODE_GROUP,
|
||||
OPT_MODE,
|
||||
OPT_FAST_GRAY_MODE,
|
||||
OPT_RESOLUTION,
|
||||
OPT_BIT_DEPTH,
|
||||
OPT_SPEED,
|
||||
OPT_SOURCE,
|
||||
OPT_PREVIEW,
|
||||
|
@ -241,7 +241,6 @@ typedef struct Mustek_Device
|
|||
SANE_Int firmware_format;
|
||||
/* firmware revision system: 0 = old, x.yz; 1 = new, Vxyz */
|
||||
SANE_Int firmware_revision_system;
|
||||
/* For SE scanners: which resolutions are allowed in color mode */
|
||||
}
|
||||
Mustek_Device;
|
||||
|
||||
|
|
|
@ -1,4 +1,4 @@
|
|||
.TH sane-mustek 5 "19 Nov 2000"
|
||||
.TH sane-mustek 5 "31 Dec 2000"
|
||||
.IX sane-mustek
|
||||
.SH NAME
|
||||
sane-mustek - SANE backend for Mustek flatbed scanners
|
||||
|
@ -97,10 +97,8 @@ SCSI scanner or the port number at which the 600 II N can
|
|||
be found (see section PARAGON 600 II N below). For SCSI
|
||||
scanners, the special device name must be a generic SCSI device or a
|
||||
symlink to such a device. The program
|
||||
.IR find-scanner
|
||||
helps to find out the correct device. It can be found in the
|
||||
.IR tools
|
||||
directory of the SANE distribution. Under Linux, such a device name
|
||||
.IR sane-find-scanner
|
||||
helps to find out the correct device. Under Linux, such a device name
|
||||
could be
|
||||
.I /dev/sga
|
||||
or
|
||||
|
@ -332,7 +330,7 @@ Example:
|
|||
export SANE_DEBUG_MUSTEK=4
|
||||
|
||||
.SH "SEE ALSO"
|
||||
sane\-scsi(5), sane-mustek_pp(5)
|
||||
sane-find-scanner(1), sane\-scsi(5), sane-mustek_pp(5)
|
||||
.SH AUTHOR
|
||||
David Mosberger, Andreas Czechanowski, Andreas Bolsch (SE extensions),
|
||||
Henning Meier-Geinitz
|
||||
|
@ -342,7 +340,7 @@ high resolutions and wide scanareas.
|
|||
|
||||
Only 1, 8 and 24 bit modes are supported until now.
|
||||
|
||||
Calibration doesn't work yet.
|
||||
Calibration doesn't work correctly for all scanners.
|
||||
|
||||
Some scanners (e.g. Paragon 1200 A3 + Pro, SE A3) need more testing.
|
||||
|
||||
|
|