Wykres commitów

3449 Commity (4962b35abd7426b7b51a00d907a538a2a38dc859)

Autor SHA1 Wiadomość Data
Olaf Meeuwissen 22b17e232a Fix various types of unused variable warnings 2015-09-25 20:53:42 -04:00
Alessandro Zummo 86ba3c634f epson2: updated supported scanners 2015-09-22 00:44:38 +02:00
m. allan noah 87bfd53512 Run autofoo for recent changes 2015-09-19 13:39:38 -04:00
Olaf Meeuwissen 20a0ed547e [epson/epson2] Use separate lists of supported USB devices
The epson and epson2 backends shared a list of supported USB devices
generated from the epson2.desc file.  The epson backend doesn't even
claim to support a large number of the devices listed there.   This
change makes the backends use their own lists, generated from their
own *.desc files.
2015-09-19 13:39:37 -04:00
Olaf Meeuwissen 1c2b28307f Prevent access to memory that was not allocated 2015-09-19 13:39:37 -04:00
Olaf Meeuwissen f152b40faf Prefer string concatenation over copying
The `ibuf.product` byte array may contain embedded NUL characters.  In
that case the revision will not be visible as part of dev->sane.model.
2015-09-19 13:39:37 -04:00
Ilya Gordeev 16dc9c87a6 Fix memory clobbering issue in sane.model creation 2015-09-19 13:39:37 -04:00
Ilya Gordeev 98e4ee4084 Fix out-of-bounds array access 2015-09-19 13:39:37 -04:00
m. allan noah a1a04f7462 Use c90 compatible comments 2015-09-19 13:39:37 -04:00
Olaf Meeuwissen 9dd31f977c Move test on first array element into the loop 2015-09-19 12:02:57 -04:00
Sandro Mani 898270810d Fix string type option descriptor's size value 2015-09-19 12:02:57 -04:00
Eduard - Gabriel Munteanu ac1bf8d754 magicolor: add support for magicolor 4690MF
Currently, this works for USB, but the network OID needs to be
filled in properly.

Signed-off-by: Eduard - Gabriel Munteanu <edgmnt@gmail.com>
2015-09-19 12:02:57 -04:00
Eduard - Gabriel Munteanu afd22f7722 magicolor: complete support for duplex ADF
This is needed to fully-support scanners like magicolor 4960MF.

Signed-off-by: Eduard - Gabriel Munteanu <edgmnt@gmail.com>
2015-09-19 12:02:57 -04:00
Eduard - Gabriel Munteanu d0c3b22d7d magicolor: fix USB device detection
Only the generic device was being picked.

Signed-off-by: Eduard - Gabriel Munteanu <edgmnt@gmail.com>
2015-09-19 12:02:57 -04:00
Rolf Bensch 348d59f859 fix typo in debug output 2015-09-18 08:55:25 +02:00
Rolf Bensch d0745a10da for all adf scanners restrict maximum page height for flatbed scans 2015-09-18 08:52:36 +02:00
Stéphane Voltz 2fd04ccf84 warning fixes 2015-09-16 18:57:03 +02:00
Stéphane Voltz 65747277cc ifdef'ed temporaly disabled code since 2004 2015-09-16 18:38:11 +02:00
Stéphane Voltz 35d7d39550 Merge remote-tracking branch 'gitlab/pu/protect-niash-option-access-315132' into niash 2015-09-16 18:16:55 +02:00
Stéphane Voltz 45df679214 fix stdup declaration
- we need to include sane/config.h first  to use strdup
2015-09-16 17:49:45 +02:00
Olaf Meeuwissen db83bf44de niash.c: Add argument screening to sane_control_option
This prevents access to non-existing array elements as well as
potential NULL dereferences.

Fixes #315132.
2015-09-14 18:24:39 +09:00
Stéphane Voltz 6c7f9f6a3b fix #300134 and file test logic
- mktmp never returns NULL, so test logic was borken
- use mkstemp instead of mktemp
2015-09-14 06:46:51 +02:00
Paul Newall 26572efbd1 redundant variable bitposn and redundant function kodakaio_rxflush commented out 2015-09-13 19:34:17 +01:00
Alessandro Zummo 2e15add10a epsonds: fixed comment about usb ids format 2015-09-10 17:13:33 +02:00
Alessandro Zummo d9e4ff311a epson2: fixed comment about usb ids format 2015-09-10 17:12:32 +02:00
Alessandro Zummo bd93d92a93 epson2: fix resolutions for Epson 4870/4990 2015-09-10 16:48:11 +02:00
Alessandro Zummo a5c2607755 epson2: upated supported models 2015-09-10 16:09:40 +02:00
m. allan noah f8725993d3 artec_eplus48u.c: fix HOME env bug #315071 (from Jörg Frings-Fürst) 2015-09-08 21:52:02 -04:00
Rolf Bensch 697d834023 Pixma backend version 0.17.22 2015-09-03 20:09:46 +02:00
Rolf Bensch af4b717297 MP990 needs specific reordering pixels for 4800 dpi 2015-09-03 20:07:17 +02:00
m. allan noah 7566619e53 rebuild with automake 1.14.1 2015-08-31 20:58:30 -04:00
Yuri Chornoivan 648d933c56 Fix minor typos in messages and comments 2015-08-31 20:31:54 -04:00
Niels Ole Salscheider e47cb8d2b4 Do not use STRINGIFY for LIBDIR but pass "LIBDIR" from build system 2015-08-31 20:31:54 -04:00
Klaus Kämpf 5337625f3a New backend pieusb
This commit adds support for (slide) scanners based
on Pacific Image Electronics (PIE) oem scan hardware.

It is known to match the following USB scanners

  PIE PowerSlide 3600       Untested
  PIE PowerSlide 3650       Untested
  PIE PowerSlide 4000       Untested
  PIE PowerSlide 5000       Untested
  Reflecta CrystalScan 7200 Untested
  Reflecta ProScan 7200     Untested
  Reflecta DigitDia 4000    Untested
  Reflecta DigitDia 5000    Untested
  Reflecta DigitDia 6000    Ok

The backend is based on work by Jan Vleeshouwers and Michael Rickmann.

Special thanks to Stéphane Voltz for the code review.

Add pieusb to backend/Makefile.am
Add pieusb to doc/Makefile.am
Add missing sanei/sanei_ir.c, sanei/sanei_ir.h, adapt Makefile.am
configure.ac: Add 'pieusb' to ALL_BACKENDS
ChangeLog: Add pieusb as new backend
Mark infrared functions as internal: sane_ir_* -> sanei_ir_*
sanei/sanei_ir.c: fix memory leaks
pieusb: rename cmdGetMode and cmdSetScanHead
	... to their sanei_pieusb_cmd_... equivalent
pieusb: rename definition_list_head to pieusb_definition_list_head
Add pieusb to AUTHORS
pieusb: copyright 2012-2015
pieusb: don't include sanei_thread.h
2015-08-31 21:07:12 +02:00
m. allan noah 9ca9cd2f56 fujitsu backend v127
- separate iX100 from iX500 settings
- iX100 has gray and lineart
2015-08-25 19:49:37 -04:00
m. allan noah 8516da91b4 canon_dr backend v51
- DR-C125 does not invert_tly, does need sw_lut
2015-08-25 19:33:51 -04:00
m. allan noah 2cb3140903 fujitsu backend v126
- initial support for iX100
- add late_lut support for iX500/iX100
2015-08-23 20:52:49 -04:00
m. allan noah 2f68498ee5 canon_dr backend v1.0.50
- DR-C125 adds duplex padding on back side
- initial support for DR-C225
2015-08-23 20:52:49 -04:00
Rolf Bensch 12bca33625 Pixma backend version 0.17.21 2015-08-10 23:20:56 +02:00
Rolf Bensch 2f4c0c16c4 EOF is a bjnp timeout error 2015-08-10 23:19:58 +02:00
Stéphane Voltz 6e9f6de1bc fix for #300132
- free memory allocated by sane_get_devices()
2015-08-10 21:49:38 +02:00
Stéphane Voltz e8c11a0849 fix for #300131
- free memory allocated by sane_get_devices()
2015-08-10 21:47:41 +02:00
Stéphane Voltz c3f0904b80 fix for #300130
- free memory allocated by sane_get_devices()
2015-08-10 21:42:09 +02:00
Stéphane Voltz f73b2e3dbf fix for #300129
- free memory allocated by sane_get_devices()
2015-08-10 21:38:16 +02:00
Stéphane Voltz 39695d73c2 fix for #300127
- free memory allocated by sane_get_devices()
2015-08-10 21:34:24 +02:00
Stéphane Voltz 7fb21d541a fix for #300126
- free memory allocated by sane_get_devices()
2015-08-10 21:30:19 +02:00
Stéphane Voltz 5129434b99 fix for #300124
- free memory allocated by sane_get_devices()
2015-08-10 21:27:33 +02:00
Stéphane Voltz 0e78307bdc fix for #300122
- free device list allocated in sane_get_devices()
2015-08-10 21:20:26 +02:00
Stéphane Voltz c39bc5ac07 fix for #300121
- free device list allocated in sane_get_devices()
2015-08-10 21:18:15 +02:00
Stéphane Voltz debdba5b8c fix for #300120
- free device list allocated in sane_get_devices()
2015-08-08 22:04:37 +02:00
Stéphane Voltz 1f1385ea67 fix memleaks in pnm backend
- fix memleaks reported in bug #313553
2015-08-08 21:31:05 +02:00
Rolf Bensch 9188678fc0 Pixma backend version 0.17.20 2015-08-07 23:21:04 +02:00
Rolf Bensch 3133c5e17a EOF isn't an usb timeout error
- this fixes usb communication problems e.g. with OpenSuse
- revoke parts of 3c5cc2a and cea03f3
2015-08-07 23:19:33 +02:00
Stéphane Voltz 425edc705e more timing issue fixing
- add another usleep() to take care of LiDE 1110/210 scan issue on some
	hardware (fast ones ?).
2015-08-06 09:06:10 +02:00
Stéphane Voltz bf65dbdd9c no color filter when using LEDADD 2015-08-06 09:01:35 +02:00
Stéphane Voltz e38641eaef fix LiDE35 GPIO setup 2015-08-06 09:01:35 +02:00
Stéphane Voltz f3914a544e fix type in lEDDADD code path 2015-08-06 09:01:35 +02:00
Alessandro Zummo d0e7675e60 epson2: added support for Perfection V800 (Nick Stroustrup) 2015-07-31 22:01:19 +02:00
Stéphane Voltz 4eea901305 fix for #315104
- allocate gamma tables even if 'warm' boot
2015-07-31 08:10:13 +02:00
Stéphane Voltz 09daef4a68 timing issue fix
- fix a timing issue on USB3 hardware (or maybe on fast recent hardware)
	debugged and tracked by John S. Weber <jweber53@gmail.com>
2015-07-30 14:28:53 +02:00
Stéphane Voltz 00c9ac83bf disable despeckle parameter at init
- since swdespeck is disabled at init, also disable despeckle diameter
2015-07-30 14:01:13 +02:00
Stéphane Voltz 82adbf6ad2 use fabs for floating point numbers 2015-07-30 14:01:13 +02:00
Rolf Bensch 061df1202b Pixma backend version 0.17.19 2015-07-29 19:10:02 +02:00
Rolf Bensch e9155caf1e MG7500 doesn't need special image format post processing 2015-07-29 19:07:04 +02:00
Rolf Bensch e9f161895d new scanner Canon PIXMA MG3600 Series 2015-07-29 19:05:54 +02:00
Louis Lagendijk 43bca22e0c backend/sane_pixma.c: added missing return in case there is no error 2015-06-27 19:04:45 +02:00
Louis Lagendijk 50a85b744c Added backend version in debug output of pixma_bjnp.c 2015-06-27 18:19:31 +02:00
Stéphane Voltz 8c515798a6 some LiDE 120 support improvement 2015-06-11 21:26:07 +02:00
Rolf Bensch 7491584574 Pixma backend version 0.17.18 2015-05-18 22:51:02 +02:00
Rolf Bensch 0ab1f99f63 new scanner Canon i-SENSYS MF8300 Series 2015-05-18 22:49:58 +02:00
Alessandro Zummo 980b4f6b06 epson2: fix compilation error 2015-05-15 20:01:32 +02:00
Alessandro Zummo 10c5ec697b epsonds: streamlined device detection 2015-05-13 00:01:24 +02:00
Alessandro Zummo 66a15edbcf epson2: consolidate cleanup 2015-05-12 03:18:37 +02:00
Alessandro Zummo 025f886f4b epson2: fix error message 2015-05-12 03:10:22 +02:00
Alessandro Zummo b2aefab4cb epsonds: enable double feed detection 2015-04-26 23:11:37 +02:00
Alessandro Zummo ccd15dc966 Revert "epsonds: enable double feed detection"
This reverts commit 005c3928a5.
2015-04-26 23:09:08 +02:00
Alessandro Zummo 005c3928a5 epsonds: enable double feed detection 2015-04-26 22:44:01 +02:00
Stéphane Voltz f6896e0de4 use expiration time option
- use expiration  time option value to managed cached entries
- changelog for genesys build #2506
2015-04-12 10:14:50 +02:00
Stéphane Voltz 1549a56b75 add cache expiration time option 2015-04-12 09:53:38 +02:00
Stéphane Voltz a039e9efd1 don't clear cache when loading cache file
- don't clear just loaded cache entries when loading another cache file
- improve logging
2015-04-12 08:55:24 +02:00
Alessandro Zummo 2aed026154 epsonds: use maximum area for ADF 2015-04-08 02:29:20 +02:00
Alessandro Zummo 0d6f925e75 epsonds: support resolution ranges in pleace of a fixed list on selected scanners 2015-04-08 01:37:54 +02:00
Alessandro Zummo f9e3a6e871 epsonds: fix Makefile.in 2015-04-08 00:21:59 +02:00
Rolf Bensch 6ca6d038e3 Pixma backend version 0.17.17 2015-04-07 22:04:56 +02:00
Rolf Bensch 0bddd4cb09 fix MP990 TPU scan 2015-04-07 22:01:38 +02:00
Alessandro Zummo 02ae5c07ea epsonds: optimize the img callback 2015-04-07 00:20:43 +02:00
Alessandro Zummo 225e00ceae epsonds: send scanning parameter all at once 2015-04-07 00:20:43 +02:00
Alessandro Zummo c3545da14d epsonds: code cleanup, fix initial hang 2015-04-07 00:20:43 +02:00
Alessandro Zummo d72f4663c0 epsonds: driver for Epson ESC/I-2 scanners 2015-04-07 00:20:43 +02:00
Rolf Bensch c063b8fa8f update copyright 2015-04-03 19:19:02 +02:00
Rolf Bensch 858e73da7e Pixma backend version 0.17.16 2015-04-03 19:09:34 +02:00
Rolf Bensch 9241d3ec28 new Canon scanners MF210, MF220, MF810/820, MF5900 and MF6100
all scanners need further testing
2015-04-03 19:07:57 +02:00
m. allan noah 0177d39642 epjitsu backend v28
call get_hardware_status before starting scan
2015-03-23 20:52:54 -04:00
m. allan noah 71ffcfe30e canon_dr backend v49
initial support for DR-C125 and possibly DR-C225
2015-03-18 20:49:15 -04:00
Stéphane Voltz 128c8931b3 add putative support for LiDE 120 2015-03-17 22:23:21 +01:00
Alessandro Zummo 5d3c2edb8f epson2: fixed depth > 8bit (thanks to Thomas M.) 2015-03-15 01:18:36 +01:00
Alessandro Zummo a73d9e1ab0 epson2: cancel requests were not handled correctly 2015-03-15 01:18:36 +01:00
René Rebe ca97cb22bd reverted 4d38523bda, the long commit message
is a nice fairy tale, not more - of course the ponter deref copies the whole
params, and most other packends do it the same way: grep *params *.c, and
consult your local C "assembler frontend" bible, ...
2015-03-07 18:56:54 +00:00
René Rebe 9511c27e59 fixed new avision feature bits for 32-bit build 2015-03-07 18:51:14 +00:00
René Rebe f69a1ad50e removed unnecessary feature_type2 clutter by using a uint64_t to share all bits 2015-03-07 11:16:47 +00:00
René Rebe e05607323d fixed duplex for some avision scanners 2015-03-07 10:50:36 +00:00
René Rebe d5c7e22328 fixed multiple Avision regressions: most scanner basically did not
work at all anymore, ... range initilaizer, clobbering paper-length
window bits, ...) introduced over the past years, added support for
newer ASIC gamma table size, added AV220D2+ ID
2015-03-07 05:07:27 +00:00
m. allan noah 15deba5c57 epjitsu backend v27
- don't override br_x and br_y
- call change_params after changing page_width
2015-03-02 20:31:46 -05:00
Stéphane Voltz f5e4a4bf8e improve LiDE 210 head parking reliability 2015-03-02 21:08:31 +01:00
Stéphane Voltz 0f990e4a99 add reverse parameter to gl124_feed 2015-03-02 17:35:20 +01:00
Stéphane Voltz debf0101f7 improve park failure detection 2015-03-02 17:25:22 +01:00
Stéphane Voltz 1eb35fe4cb final tuning for LiDE 220 support 2015-03-01 21:43:08 +01:00
Stéphane Voltz 470594e18b initial support for LiDE 220 2015-02-26 22:26:00 +01:00
Rolf Bensch f78057e8db Pixma backend version 0.17.15 2015-02-21 11:20:41 +01:00
Rolf Bensch 7d7025838e new scanners Canon PIXMA MX490 Series and E480 Series 2015-02-21 11:18:40 +01:00
Rolf Bensch bf60fd1f61 MG6400 doesn't need special image format post processing 2015-02-21 10:34:52 +01:00
Ilia Sotnikov 9d9cefb7a7 * Invert pixels in case of TMA Negatives source has been selected.
Thanks for Will Kranz who reported this.
2015-01-20 12:33:49 +03:00
Paul Newall 6b1455a8cf kodakaio device connection and disconnection moved to sane_start and sane_cancel to fix bug when scanner disconnected after 30s idle 2014-12-31 10:26:07 +00:00
Paul Newall 06fae35262 kodakaio params.depth corrected for lineart, color mode made the default. 2014-12-19 22:52:48 +00:00
m. allan noah 67417622cb bump version number of fujitsu backend 2014-12-16 08:29:58 -05:00
m. allan noah fb8693bf09 fujitsu: remove command counting code
This code was a crude workaround for a problem with a
better solution at the USB library layer. Remove it.
2014-12-12 20:40:07 -05:00
m. allan noah a429b8a0ed fujitsu backend v124
- support resolution controlled max page-height (fi-6/7xxx scanners)
- reorder scanner sections in init_model chronologically
2014-12-09 20:52:06 -05:00
Rolf Bensch e1f7a7d452 Pixma backend version 0.17.14 2014-11-18 09:16:37 +01:00
Rolf Bensch 5e7dc373c8 MF8200C: ADF supports max. 300DPI
- use adftpu_max_dpi to set max. resolution for ADF
2014-11-18 09:14:46 +01:00
Rolf Bensch 98125c97d6 mf8[25]00 use generation 2 protocols 2014-11-18 09:04:18 +01:00
Rolf Bensch 1fa16a1aab also use has_paper() for generation 2 scanners 2014-11-18 09:03:13 +01:00
Rolf Bensch 681c8366b5 Remove firmware checking for HP5370c scanners 2014-11-15 14:40:49 +01:00
m. allan noah 7a590f362e fujitsu backend v123
workaround Linux USB3 bugs by adding command counting code and
sending an even number of reads and writes during disconnect_fd
2014-11-06 20:48:40 -05:00
Rolf Bensch ccdd519ece Pixma backend version 0.17.13 2014-10-29 09:16:06 +01:00
Rolf Bensch fdfde41ed1 new Canon scanners
MAXIFY MB5000, MB5300, MB2000, MB2300
  PIXMA MG7500, MG6600, MG5600, MG2900, E460
  *all scanners need further testing*
2014-10-29 09:14:50 +01:00
m. allan noah 41c31ac0e9 fujitsu backend v122
- add support for object_position halt
- call object_position halt in check_for_cancel when requested
2014-10-28 19:19:46 -04:00
Rolf Bensch 869e3f75a6 Pixma backend version 0.17.12 2014-10-27 17:17:07 +01:00
Rolf Bensch 027f9e4ed4 MG3500 doesn't need special image post processing 2014-10-27 16:04:22 +01:00
Rolf Bensch a93c243c26 calibration can finish with 0x01 or 0x02 2014-10-20 17:56:46 +02:00
Rolf Bensch b7e8e035a4 increase calibration timeout 2014-10-20 17:54:46 +02:00
Rolf Bensch a69a613a25 new scanner imageCLASS D530 2014-10-20 17:14:23 +02:00
Rolf Bensch 54358f27e1 Canon Pixma MG5500 Series is working 2014-09-18 21:54:28 +02:00
Rolf Bensch cb25926d05 Pixma backend version 0.17.11 2014-09-16 11:47:27 +02:00
Rolf Bensch ea54338db7 MX530 doesn't need image post processing 2014-09-16 11:18:12 +02:00
Paul Newall d2bbf502c7 kodakaio: Added lineart mode and threshold option. 2014-09-13 23:26:04 +01:00
Paul Newall 4a49f58700 Fixed colour compensation error in kodakaio 2014-09-07 13:38:58 +01:00
Louis Lagendijk b4856a8a31 pixma_bjnp.c: added explicit error message for the case where the
scanner closes the TCP-connection
2014-08-23 14:36:05 +02:00
Louis Lagendijk 3ce1cec6a3 pixma_bjnp.c: Open TCP-connection only from bjnp_activate. bjnp_open should not intiate
a connection. This solves issues where the scanner closes it's TCP-connection after a
period of no activity.
2014-08-23 14:25:56 +02:00
Rolf Bensch a3a2d2038d MX720 has button support 2014-08-16 21:56:46 +02:00
Rolf Bensch 1afd805389 MX720 doesn't need image post processing 2014-08-16 16:45:06 +02:00
Rolf Bensch 7908858a3a MX720 has duplex adf 2014-08-16 16:44:02 +02:00
Rolf Bensch 99eac9c6eb Pixma backend version 0.17.10 2014-08-16 12:25:55 +02:00
Rolf Bensch 3f6a17bcbd new scanners Canon i-SENSYS MF8200C Series and MF8500C Series 2014-08-16 12:15:36 +02:00
m. allan noah 1e04f18ed1 canon_dr backend v48
- set another unknown byte in buffermode for ssm2
- add another gettimeofday call at end of do_usb_cmd
- don't print 0 length line in hexdump
- mark DR-7080C as working
- default DR-G1100 and DR-G1130 to 8 meg buffers
2014-08-06 21:42:00 -04:00
m. allan noah 68bc35d36a fujitsu: don't print 0 length line in hexdump 2014-08-06 21:42:00 -04:00
Rolf Bensch a0e2df7254 new scanners Canon Pixma E400, E560, MX470 and MX530 2014-07-25 20:51:53 +02:00
m. allan noah 44bdd65b51 canon_dr backend v47
initial DR-G1130 support
add usb ids for many recent scanners
2014-07-14 20:02:05 -04:00
m. allan noah 683f6d71f4 epjitsu backend v26
- add resolution scaling
- fix 150 dpi settings for fi-60F and fi-65F
- make adf_height_padding variable
- make white_factor variable
2014-07-02 09:48:55 -04:00
Stéphane Voltz 42e3246117 fix gain calibration
- enable GMMENB during calibration scan in simple_scan, otherwise there
  is 'color clamping' with default asic table
2014-06-29 08:38:48 +02:00
m. allan noah a7aa92f54d epjitsu backend v25
- initial support for fi-65F
- initial support for S1100
2014-06-12 21:25:14 -04:00