Generated hwdb files listed the vendor ID instead of the product ID
which made udevd not recognizing scanner devices as such. Thanks to
Fabrice Bellet who spotted the problem.
Improving here means do not set LIBS/CFLAGS if library is not detected.
This prevents some unknown options based to ld when host is Linux and
target is mingw32/64. Further improvements are needed if one wants this
snmp support when cross compiling to really work.
Also, to make commit bisectable, updated all autofoo files using
'autoreconf -i -f' and repatching ltmain.sh.
Also, test-driver was missing from git repo but the Makefile.in
checked in expected it to exist.
udev now comes with a hardware database (hwdb) which is meant to replace large
rule files as the one typically shipped with sane. This should significantly
speed up the processing of usb add events.
Add the required output format and add a special udev output mode which is
produces the udev file to be used with hwdb.
Sample hwdb file: <https://dev.archlinux.org/~tomegun/20-sane.hwdb>.
Sample udev+hwdb rules file:
<https://dev.archlinux.org/~tomegun/53-sane.rules>.
Similar support was recently added to gphoto2:
<http://sourceforge.net/p/gphoto/code/14490/>.
The new udev rules file does not support old udev/kernels as these anyway
don't support hwdb.
Moreover, it does not come with GROUP=/MODE= or ACL support as this can easily
be done externally by hooking into the libsane_matched envvar. In particular
systemd-logind uses this to do its own ACL handling.
using backend debugging using SANE_DEBUG_xxx to be used for saned controlled
scanning when using socket activation. When only the socket is received we
use the existing code path.
Options were in README but removed at some point. They
are useful so add them back.
Document BACKENDS and PRELOADABLE_BACKENDS variables in
README as well as in configure --help output.
Add check for winsock2.h for socket.h replancement. Also, use this
check to add ws2_32 library. Also, switch all winsock.h references
to winsock2.h.
Add check for getuid and getpass; which are not on mingw.
Add a syslog() replacement that is basically a print(). This
is also used by vsyslog() replacement.
Comment out parts of replacement sigprocmask.c on mingw.
To support these configure.in changes, I need to rebuild all
related files with autoconf 2.68 and libtool 2.4. Hand ported
our sane-backend specific changes to newer ltmain.sh.
As we require pkg-config anyway, simply let sane-config use it to make
it compatible with multilib systems. Previously, sane-config contained
paths which were different on e.g. x86_64 and i386 which made the 64 and
32 bit versions conflict if installed in parallel.
Use ACLs for the scanner group instead of making the device root:scanner
with permissions 0664; designed to help with MFPs and play nice with
ConsoleKit.
create a place holder for low level commands
move low level functions to genesys_low.c
GL124 progresses
enable genesys_low debug and add DAC for LiDE 110
gl124 WIP
- gl847 cleanups
- genesys_low refactor
- gl124 starting version
GL124 WIP
- read scancnt/fedcnt,valid words coded
- memory layout coded
LiDE110 WIP
GL 124 WIP
- definition and use of get/set double/triple
- define register names
all mods done, ready to test
set fe OK
GL124 WIP : ready to test scans
GL124 WIP
GL124 WIP
- fixed analog fe issue: don't put afe regs in global set
GL124 : first light at 300 dpi
GL124 WIP
- 300 and 600 uncalibrated mostly ok (x coordinate rounding)
- 150 and 75 OK x-wise, y to be solved
solved rounding errors for gl124
re-add 400, 200 and 100 dpi modes
GL124 : tous x dpi OK
before adding line cropping
GL124 : line cropping almost finished
GL124 WIP : working line deletion
compute step rework
GL124 WIP : high speed table for dpi <= 300
move to scan area working
line skipping fix
new slope table for 600 dpi base
geometry and movement tuned
GL124 WIP : shading calibration almost working
working 600 dpi shading
GL124 : working shading calibration for all modes but 1200 dpi
working 1200 dpi shading
beta 1 of GL124 support
last tuning
update genesys.desc for LiDE 110
motor slope and start area tuning
shading coefficient computing clean up
add support for GL124 based CanoScan LiDE 110
feed almost OK up to 300 dpi
feeding is fixed
all issues fixed
Not quite ready to support pkg-config yet but go ahead and provide
basic support in configure to discourage distributions that are
patching pkg-config support in to no longer run "autoreconf -f"
and wiping out our custom libtool. sane-backends.pc will not
be installed currently.
Also, fixed a LDFLAGS bug in sane-config for GPHOTO2 support.
Signed-off-by: Chris Bagwell <chris@cnpbagwell.com>
resmgr library is only used (optionally) by
sanei_usb and sanei_scsi. So only need to
link it in for those backends. This was
a stray piece from initial cleanup of LIBS
in sane-backends 1.0.20.
Signed-off-by: Chris Bagwell <chris@cnpbagwell.com>