Wykres commitów

1796 Commity (1e381db161cfa319427e80bb0ae4d198f725aceb)

Autor SHA1 Wiadomość Data
Jochen Eisinger 30342e4b07 2008-05-07 Jochen Eisinger <jochen@penguin-breeder.org>
* doc/sane-mustek_pp.conf: fix catman warning. Reported by
	  Raymond Chen.
2008-05-07 06:35:51 +00:00
Stéphane Voltz 1eb416ba47 - description update for untested HP4400 model
- 150 dpi mode fix for HP4470 models sold with XPA
2008-05-06 20:00:32 +00:00
Earle F. Philhower III 7502fa5b83 Add lineart and halftone (were supported but not documented in manpage) 2008-05-06 01:52:22 +00:00
Nicolas Martin 3f86915941 Description and man updates for PIXMA MX300. 2008-05-05 21:20:50 +00:00
Nicolas Martin 9ee0385130 Code cleanup patch to imageClass backend (pixma) by Dennis Lou. 2008-05-04 17:34:20 +00:00
Julien BLACHE 11008838c8 Fix leftover SANE_STATUS_SUCCESS. 2008-05-03 17:06:58 +00:00
Julien BLACHE 4daf488f4a Replace occurrences of SANE_STATUS_SUCCESS with SANE_STATUS_GOOD. 2008-05-03 16:57:32 +00:00
m. allan noah 16f5a83f8d fujitsu: support new fi-6x20
epjitsu: mention new S300M
2008-04-23 01:55:34 +00:00
Nicolas Martin 8e5710ca1c Updated release version of pixma backend. 2008-04-22 19:30:14 +00:00
Nicolas Martin fcc26f51e1 Update descriptions for Canon ImageCLASS series MFPs. 2008-04-21 19:24:46 +00:00
Nicolas Martin 20cbe6eb4f Update man pages for Canon ImageCLASS series MFPs. 2008-04-21 19:24:07 +00:00
m. allan noah 39458249b5 backend version 1.0.58:
- page code 32 is not color interlacing, rename to 'unknown'
- increase number of bytes in response buffer of init_ms()
- protect debug modification code in init_ms() if NDEBUG is set
- proper async sane_cancel support
- re-enable JPEG support
- replace s->img_count with s->side
- sane_get_parameters(): dont round up larger than current paper size
- sane_start() rewritten, shorter, more clear
- return values are SANE_Status, not int
- hide unused functions
2008-04-20 01:31:29 +00:00
Nicolas Martin 983e8c0eeb Update for MP970 (yet for color scan, all resolutions) and bug fix for MP220 at 1200 dpi (reported to work OK) 2008-04-15 21:27:34 +00:00
Mattias Ellert 8196a0f471 Format warning fixes, man page fixes 2008-04-12 17:49:49 +00:00
Julien BLACHE 90a1c88e0d saned can now drop privileges when running in standalone mode. 2008-04-10 16:55:36 +00:00
Julien BLACHE 9c6fea1943 Add standalone daemon mode, building upon the AF-indep/IPv6 debug mode.
Reorganize code by splitting the main() function into a series of functions.
Factorize common code between the old network code and the AF-indep code. There's now only one version of main().
2008-04-06 15:21:47 +00:00
Nicolas Martin d9d44cbe72 Added a tempo before failing in NO PAPER in ADF scan, declared MX850, changed MP970 to Generation 3. 2008-04-02 20:13:48 +00:00
Stéphane Voltz b85ec879da - rts8891 backend inclusion 2008-03-22 14:33:36 +00:00
Nicolas Martin 52ec47a434 Added Canon PIXMA MX700, declared MX300 and MX310, and updated some descriptions. 2008-03-16 16:33:53 +00:00
Stéphane Voltz 5be6af9c72 - removed scanners supported by the lexmark backend from
unsupported.desc
	- umax_pp small copyright refresh
2008-03-02 15:01:13 +00:00
Gerard Klaver 430d0d77ed Update with Dexxa 4800 support information 2008-03-01 12:32:02 +00:00
Nicolas Martin 9b78a1bf11 Update for PIXMA MP140 now working with pixma backend 2008-02-24 09:25:38 +00:00
Nicolas Martin bf6f5936e8 Update for PIXMA MP140 now working with pixma backend 2008-02-24 09:24:49 +00:00
Nicolas Martin 5ff80f5f36 Changed MP140 comment to not working yet 2008-02-22 21:43:46 +00:00
Nicolas Martin 8b5f920250 Set MP140 as experimental, cause not working yet with backend 2008-02-22 21:42:30 +00:00
Nicolas Martin 67ee16dc69 Changed name: MultiPass MP710 and MP740 to Pixma MP710 and MP740 2008-02-18 20:50:56 +00:00
Nicolas Martin 2738f8f5b8 Changed name: MultiPass MP710 and MP740 to Pixma MP710 and MP740 2008-02-18 20:49:46 +00:00
Nicolas Martin e9d79945fd Back to previous external backend list, and comment updates 2008-02-18 20:40:34 +00:00
Nicolas Martin a1265b6dad New models changes:
- added: Pixma MP210, MP470, MP520, MP610
 - added: MultiPASS MP710
 - declared untested: MP140, MP220, MultiPASS MP740
 - declared experimental and untested: MP970
Bugs and fixes
 - multipage documents scan no more fails with non-ADF MPs
 - IO Fail bug when scanning large pages e.g. with Xsane
 - implement send_time message form MP710, MP730 family
 - run indent -gnu on all pixma_* source files.
2008-02-17 15:49:43 +00:00
Jonathan Bravo Lopez e1f9664106 Added support for a new scanner: HP ScanJet G2710
Minor changes
2008-02-13 06:35:26 +00:00
m. allan noah 5158f5113b sane 1.0.19-cvs 2008-02-11 02:50:55 +00:00
m. allan noah 753706f6e7 fix broken DISTFILES, etc 2008-02-10 23:02:31 +00:00
m. allan noah 1e572167d7 SANE 1.0.19 release 2008-02-10 20:32:40 +00:00
m. allan noah 2c5ba93ff4 add usb id 2008-02-09 23:57:59 +00:00
m. allan noah 65fa50cd4d add usb ids 2008-02-08 00:27:50 +00:00
Mattias Ellert 22efa538b7 Fix warnings about ignored --datarootdir 2008-02-03 06:59:36 +00:00
m. allan noah a330f4b2d8 fix snapscan bug, add LiDE 600F 2008-01-29 17:48:42 +00:00
Alessandro Zummo 6322e207ef added epson2 .desc file 2008-01-23 17:06:46 +00:00
m. allan noah 6f8f3765f1 remove 'new' flag 2008-01-23 01:51:09 +00:00
m. allan noah 587744776e add DBG calls to hpljm1005, hide 'compression arg' option in fujitsu 2008-01-23 01:21:21 +00:00
m. allan noah 5afcaa4489 adding hpljm1005 backend (i know, i know, so much for feature freeze :)
latest .fr updates
2008-01-18 01:27:22 +00:00
m. allan noah 58045b775b updated fr translation from Yann E. MORIN, added S500M usb id to fujitsu 2008-01-17 01:03:43 +00:00
m. allan noah 522ec3b895 oops- added wrong id for CX-6600 2008-01-09 00:52:05 +00:00
m. allan noah 777c3f4d9c added cx-6300 (same as 64 and 6600?) 2008-01-08 01:58:32 +00:00
m. allan noah 45665e35c8 missed one 2008-01-07 09:41:55 +00:00
m. allan noah 17a7caebaf various description updates to clean up the bug tracker. 2008-01-07 09:37:56 +00:00
m. allan noah a006d79939 mark epson unsupported, remove ricoh and fujitsu from unsupported list 2008-01-06 21:38:58 +00:00
m. allan noah dc61dc4471 add new hs2p backend for ricoh is450 series scanners 2008-01-03 02:42:32 +00:00
m. allan noah d3cc1b13a8 backend version 1.0.10- fix missing function 2007-12-19 22:14:19 +00:00
Mattias Ellert 4bb074f81c New translation keys for hp3900 backend. Updated Swedish translation 2007-12-19 10:47:04 +00:00
m. allan noah 5a574ccb66 html converter only likes lowercase hex 2007-12-18 03:08:13 +00:00
m. allan noah 38f280276d Updated company name. 2007-12-18 02:36:55 +00:00
m. allan noah 559212e96e Adding v1.0.9 of the epjitsu backend: supports Epson-based Fujitsu scanners,
currently the fi-60F flatbed and ScanSnap S300 duplex ADF machines
2007-12-18 02:02:51 +00:00
Gerhard Jaeger 7b92571b3b Update 2007-12-17 14:27:16 +00:00
Jonathan Bravo Lopez 694ad19785 Added files for 'hp3900' backend 2007-12-13 00:28:45 +00:00
Jonathan Bravo Lopez 46376814f2 Added files for 'hp3900' backend 2007-12-13 00:26:08 +00:00
Gerhard Jaeger b441de8774 * doc/sane-plustek.man doc/plustek/Plustek-USB.changes: Update 2007-11-23 16:48:07 +00:00
m. allan noah b4e05e5e23 update to backend version 1.0.53
- add ID for S510
 - note jblache's NUM_OPTS type fix
2007-11-18 01:48:20 +00:00
Gerhard Jaeger a933814615 Update 2007-11-16 08:40:56 +00:00
Julien BLACHE eb850185bb Update epkowa.desc for iScan! 2.10.0. 2007-11-12 09:10:09 +00:00
Mattias Ellert 93e856b53f Cross compilation fixes and libtool update 2007-11-10 07:12:55 +00:00
Gerhard Jaeger 85c089c91d Added support for TravelScan464 2007-11-08 19:53:14 +00:00
Gerhard Jaeger cae6a9f758 Update 2007-11-08 19:52:00 +00:00
Gerhard Jaeger 09742ab30a Updated some entries 2007-11-08 19:47:12 +00:00
Bertrik Sikken 231ed7da30 Added DCP-8060 after report on sane-devel 20071021 2007-10-31 18:38:17 +00:00
Bertrik Sikken 4d198b6708 Mark DCP-110C as good, based on user report from sane-devel 20071011 2007-10-31 18:27:19 +00:00
Julien BLACHE f5a4d0af2b Added the Epson DX-6000 (04b8:082e) based on user report. 2007-10-28 09:57:44 +00:00
Julien BLACHE 4cf4d8dd7f Add an optional connection timeout option for the net backend. This can be used to prevent the backend from hanging for several minutes when the saned server is unresponsive. 2007-10-24 10:32:46 +00:00
Bertrik Sikken e510006077 Added Epson Stylus DX4450 description 2007-10-08 18:50:52 +00:00
Bertrik Sikken ca35c21cfc Added Brother MFC-2500 description 2007-10-08 18:44:23 +00:00
Bertrik Sikken c64f523589 Added CanoScan LiDE 90 description 2007-10-07 11:15:42 +00:00
Bertrik Sikken abe3c7326d Added Plustek OpticSlim 500 description 2007-10-07 11:11:08 +00:00
Bertrik Sikken b57a00502f Added Visioneer 9420 description 2007-10-07 11:05:20 +00:00
Bertrik Sikken ff482a9207 Updated Agfa Duoscan T2000XL description 2007-10-07 10:54:30 +00:00
Bertrik Sikken f7d50cd5e4 Added Kodak i260 description 2007-10-07 10:48:44 +00:00
Bertrik Sikken 1d3e9cfe89 Updated Visioneer Onetouch 8900 description 2007-10-07 10:42:34 +00:00
Bertrik Sikken 2af6357bc5 Added Lexmark X3450 description 2007-10-07 10:29:16 +00:00
Bertrik Sikken aed8b74913 Added Ricoh IS450 description 2007-10-07 10:01:52 +00:00
Bertrik Sikken 6f0b681ea5 Added DR-4010C description 2007-10-07 09:40:06 +00:00
Bertrik Sikken f1bd5626d8 Added Benq 5450 description 2007-10-07 09:26:09 +00:00
Julien BLACHE 2b3275c001 Mark the Brother DCP-117C support as good and add USB IDs, based on user report. 2007-10-02 09:41:26 +00:00
Stéphane Voltz dce6df9182 - moved experimental version to current tree 2007-10-01 04:27:24 +00:00
Stéphane Voltz 8c638f5802 - added the 'Genius ColorPage-Life Pro' as supported by the
umax_pp backend
2007-10-01 03:53:56 +00:00
Bertrik Sikken 55d33cf903 Added Plustek PL812 description 2007-09-28 13:50:19 +00:00
Bertrik Sikken eff43923d4 Added Benq 5550 description 2007-09-28 13:44:21 +00:00
Bertrik Sikken 6bf8170e17 Added ScanMaker S400 description 2007-09-28 13:10:11 +00:00
Bertrik Sikken ed31842a08 Added Fujitsu fi-60F description 2007-09-28 12:59:55 +00:00
Bertrik Sikken 214252d178 Added Microtek ScanMaker 3860 description 2007-09-28 12:44:31 +00:00
Julien BLACHE 929f057596 Fix typos in backend-writing.txt. 2007-09-27 09:30:25 +00:00
Julien BLACHE 82602663f3 Added pointer to http://code.google.com/p/kvss905c/ for the Panasonic KV-SS905C and Panasonic KV-S3105C scanners. 2007-09-26 18:49:51 +00:00
Bertrik Sikken 2b00ac844a Added Nikon LS-9000 ED description 2007-09-25 19:36:41 +00:00
Bertrik Sikken 35a0a657c8 Added Canon DR-7580 description 2007-09-25 18:46:35 +00:00
Bertrik Sikken 45c0fb7cc1 Added Tamarack Artiscan 2400FS description 2007-09-25 18:28:47 +00:00
Bertrik Sikken 53f7c2d377 Added Primax Onetouch 8920 description 2007-09-25 18:20:26 +00:00
Bertrik Sikken d6dbb069ab Added Microtek artixscanDI 2020 description 2007-09-25 17:57:39 +00:00
Bertrik Sikken a19a40ae0b Fixed uppercase USB id for Samsung SCX-4725FN 2007-09-23 22:47:32 +00:00
Bertrik Sikken 78c236c327 Updated Brother MFC-9180 status (see Formulardaten mail on sane-devel, 2007/5/11 2007-09-23 21:54:53 +00:00
Bertrik Sikken 753deea4ab Added Hewlett-Packard ScanJet G4050 description. 2007-09-23 21:48:17 +00:00
Bertrik Sikken 9c3ffc119d Added Plustek PL806 description. 2007-09-23 21:31:10 +00:00
Bertrik Sikken d2b5f0bbe8 Added Visioneer Strobe XP 300 description. 2007-09-23 21:16:31 +00:00
Bertrik Sikken 96c6e7b163 Fixed Hewlett-Packard Scanjet G4000 link. Added G4010. 2007-09-23 21:06:00 +00:00
Bertrik Sikken 222682dbfc Added Samsung SCX-4725FN description. 2007-09-23 20:37:17 +00:00
Bertrik Sikken 5ba33efd1c Added Lexmark X1250 and X1290 descriptions. 2007-09-23 20:23:36 +00:00
Bertrik Sikken fdd9ab1be6 Added Hewlett-Packard Photosmart C3180 info 2007-09-23 19:30:35 +00:00
Bertrik Sikken d40a256e14 Removed Genius ColorPage Slim 1200 because it is already listed as 'untested' for the gt68xx backend 2007-09-23 18:56:00 +00:00
Bertrik Sikken 3b88cf6cd2 Added PIE PF3650 description 2007-09-23 18:34:58 +00:00
Bertrik Sikken ba47afd344 Added LexMark X8350 info 2007-09-23 18:13:04 +00:00
Gerhard Jaeger 1b3fc23141 #305009 removed UMAX3400, as it is supported by the Plustek backend 2007-09-17 06:03:26 +00:00
Stéphane Voltz 84e356fdf4 - fixed wrongly commited changes, for real this time
previous fixed was only for MAIN, not HEAD version.
2007-09-02 19:30:41 +00:00
Stéphane Voltz c0ee8a2143 - mail address update
- minor man update
2007-08-27 04:58:53 +00:00
Stéphane Voltz 6213a520ac * release candidate for inclusion in CVS main:
- X1200 fully working on USB 1.1, USB 2.0 needs more testing
	- clean-ups
2007-08-27 04:39:45 +00:00
Henning Geinitz 4b83c2d24c Added Artec Ultima 2000 e+, Nortek Myscan 1200, NeatReceipts Scanalizer
Professional, Genius Colorpage Slim-1200. Name and email address changes.
2007-08-19 13:30:46 +00:00
Julien BLACHE f4a6016611 Added various USB IDs. 2007-08-18 12:06:36 +00:00
Henning Geinitz 6ca105af27 Added. 2007-08-12 16:58:06 +00:00
m. allan noah b2666cada5 scanimage: bugfix, dont round up negative user input values
fujitsu.desc: add/consolidate new models
2007-08-08 12:46:02 +00:00
Julien BLACHE 94f0ce1b00 Add the Epson Stylus CX-6600 (04b8:0813) based on user report. 2007-08-03 11:34:31 +00:00
Julien BLACHE 6d6e4271e0 Add the Epson Stylus Photo RX-700 (04b8:0810). 2007-08-03 11:31:15 +00:00
Julien BLACHE 2db8ec7d98 Add the Epson Stylus DX-5050 (04b8:082b). 2007-07-31 11:48:49 +00:00
Julien BLACHE 964eccff2c Add Epson Stylus DX-5000 (04b8:082b) based on several reports. 2007-07-30 13:36:52 +00:00
Julien BLACHE ef05fcdbad Add Epson Stylus DX4050 (04b8:082f) based on several reports. 2007-07-30 13:32:34 +00:00
Gerhard Jaeger 890735a81e Updated some Plustek entries 2007-07-26 20:41:24 +00:00
Gerhard Jaeger 6dd0fcb533 Update 2007-07-26 20:36:08 +00:00
Wittawat Yamwong c4af52e84a Updated pixma backend to version 0.13.1
Added PIXMA MP960
2007-07-19 22:17:21 +00:00
m. allan noah 44e085b331 update website in manpage 2007-07-16 00:42:24 +00:00
m. allan noah 048161249d * doc/descriptions/fujitsu.desc: update website and fi-60F status
* Authors, backend/dll.conf.in: added cardscan backend
2007-07-16 00:39:24 +00:00
m. allan noah 41761fede4 add new backend for Corex CardScan 800c, small-format sheetfed usb scanner
for cards/receipts, etc.
2007-07-15 01:46:47 +00:00
m. allan noah 5973ebe12d add new models and fix bug in man page
drop sanei_thread.lo from libsane-fujitsu.la (fujitsu backend single threaded)
2007-07-15 00:59:14 +00:00
Gerhard Jaeger 1af405f31d Fixed web entries 2007-07-10 06:18:46 +00:00
Gerhard Jaeger a775aebc03 Update, added Q-Scan 2007-06-29 08:36:54 +00:00
Gerhard Jaeger 64382b400b Bumped version and moved Q-Scan to plustek.desc 2007-06-29 08:34:54 +00:00
m. allan noah 26d0e072ee update to v 1.0.49. add fi-5750C and S510 2007-06-28 17:53:09 +00:00
Gerhard Jaeger 7d94e07e0b Update. 2007-06-18 20:27:05 +00:00
Mattias Ellert aa25569539 Adding hp5590 man page to build 2007-05-20 06:22:25 +00:00
Ilia Sotnikov 345ef5a7fe + Added description for 'hp5590' backend which supports
HP ScanJet 5550/5590/7650 scanners
2007-04-24 17:58:33 +00:00
Ilia Sotnikov 89e6972d5c - Removed as 'hp5590' backend is not external anymore 2007-04-24 17:57:34 +00:00
Ilia Sotnikov bb31b94180 + Added files for 'hp5590' backend which supports HP ScanJet 5550/5590/7650
scanners
2007-04-24 17:56:36 +00:00
Mattias Ellert 78ff28cb83 Adding new external backend hp5590 2007-04-21 16:17:56 +00:00
Troy Rollo ee413cf781 HP3500 backend:
Improve speed and reduce noise of most resolutions
	Deal with an escape code discovered in the scanner's protocol
	Use hardware detailed calibrations for resolutions up to 300
	Use improved software detailed calibration for other resolutions
	Add more debug information
	Drop the 25dpi resolution
	Make 200dpi the default (the same as the Windows frontend)
	Add code (not used yet) to deal partially with grayscale and
		lineart scanning
	Use I18N strings where appropriate
2007-04-21 07:19:14 +00:00
m. allan noah 51965d59ec move some models to 'untested', everything else to good! 2007-04-15 19:20:55 +00:00
m. allan noah 641a50e7e5 add a couple models, move some discontinued ones. 2007-04-15 19:02:53 +00:00
Wittawat Yamwong efced87595 Remove Canon PIXMA MP160 & MP600 from unsupported. (supported by pixma) 2007-04-14 23:32:40 +00:00
Mattias Ellert 833ae68aca Moved 3 scanners from unsupported to hp3900 2007-04-13 20:17:05 +00:00
m. allan noah 47cb655c19 update to backend v1.0.47 2007-04-13 15:50:20 +00:00
Wittawat Yamwong 459d5c7e8e * Updated to version 0.13.0
* Added MP160, MP180, MP460, MP510 and MP600
* Fixed a buffer-overflow bug in sane_read()
2007-04-09 20:41:25 +00:00
m. allan noah ed0e4af3d5 fix SANE_Parameters description 2007-04-02 19:07:46 +00:00
m. allan noah 5f60b3ac4a add usbid 2007-03-09 02:15:18 +00:00
Gerhard Jaeger 58e17e99cc Update. 2007-03-05 20:14:07 +00:00
Jochen Eisinger 78e9962f4b 2007-02-11 Jochen Eisinger <jochen@penguin-breeder.org>
* doc/sane-mustek_pp.man: clean up markup, bug #304392
2007-02-11 17:36:31 +00:00
Oliver Rauch f522eb92d4 *** empty log message *** 2007-01-29 21:41:00 +00:00
Henning Geinitz e486896f0e Added Canon Imagerunnerseries. 2007-01-28 16:58:19 +00:00
Henning Geinitz 313a5f80b6 Added .conf entry for Pluste OpticPro S12 and S24. Updated .desc file. 2007-01-28 15:58:40 +00:00
Henning Geinitz e8a59a97df Added UMAX Astra 2850. 2007-01-28 15:58:09 +00:00
m. allan noah 4eabb3820c updated to backend version 1.0.44, updated maintainer email addy 2007-01-27 01:42:13 +00:00
Jochen Eisinger 50a260fee3 2006-01-21 Jochen Eisinger <jochen@penguin-breeder.org>
* doc/descriptions/mustek_pp.desc: Cybercom is a CIS scanner
2007-01-21 21:51:00 +00:00
Mattias Ellert cc8acd0d7e Adding Visioneer Strobe Pro USB to unsupported 2007-01-19 14:52:14 +00:00
Henning Geinitz 7bb5933bca Updated. 2007-01-15 23:46:37 +00:00
Julien BLACHE 0973fd051c Fix man warnings. 2007-01-08 19:02:09 +00:00
Julien BLACHE aae12092de Fix man warnings. 2007-01-08 18:40:30 +00:00
Henning Geinitz cfc1f96ba8 SCX-4200 is reported to work. 2006-11-27 19:49:06 +00:00
Gerhard Jaeger 06323b4597 * doc/plustek/Plustek-USB.changes: update.
* backend/plustek.c: bumped build number, fixed option
  descriptors, see bug #303786.
2006-11-22 20:30:32 +00:00
Henning Geinitz f3f6ce01a7 Updated status of Brother MFC-7420. 2006-11-22 20:19:05 +00:00
Henning Geinitz db352cc1b7 Updated status of UMAX 2000. 2006-11-22 20:17:30 +00:00
Henning Geinitz b8b81f00d5 Added several scanners, fixed the USB id for Microtek 4850 (bug #304151). 2006-11-22 20:16:09 +00:00
m. allan noah 5e81563b60 updated external desc 2006-11-06 13:55:50 +00:00
Henning Geinitz 3f8864e7e7 Project is unmaintained. 2006-10-31 19:26:26 +00:00
Henning Geinitz 9b46fe372c Added HP Photosmart C5100 and ScanJet 8390. 2006-10-31 19:22:19 +00:00
Henning Geinitz 8cd0f282a9 Added Canon Canoscan 4400F, LiDE 70, Corex Cardscan 700 C, Umax Astra 4900,
Visioneer Onetouch 7700. Updated other scanners.
2006-10-24 20:53:47 +00:00
Henning Geinitz c04d8433d5 Updated based on sane-devel information. 2006-10-24 20:50:22 +00:00
Henning Geinitz 2df19bcd0b Added Support for Genius Colorpage SF600. 2006-10-03 21:24:39 +00:00
Henning Geinitz a0b7aed86d Added EDT BizCardReader 900C. Moved Genius ColorPage-SF600 to gt68xx.desc. Minor
updates.
2006-10-03 21:19:31 +00:00
Henning Geinitz 6bff1fdf4b Added examples on how to set the scan area in the manual page (bug
#303802). Mention how to separate parameters from options in --help and manpage
(bug #303819).
2006-10-03 18:39:35 +00:00
Henning Geinitz 316075f0c4 Changed status of HP Scanjet 4370 to "minimal" (bug #303839). 2006-10-03 17:57:56 +00:00
Gerard Klaver 18af0fc806 removed, updated file is in /doc/descriptions 2006-09-27 17:27:23 +00:00
m. allan noah 2eb55005c6 update to v1.0.43 2006-09-19 12:04:54 +00:00
Henning Geinitz 69914baf00 Added several scanners. 2006-09-14 18:14:13 +00:00
m. allan noah 3a78258ac5 update to v1.0.42 2006-09-01 00:31:45 +00:00
Gerhard Jaeger e44b51c218 * doc/plustek/Plustek-PARPORT.changes: update.
* backend/plustek-pp.h backend/plustek-pp_ptdrv.c backend/plustek_pp.c:
  fixed "not homing" problem, the sensor did not return when
  the driver gets the _IOCTL_STOP command
  fixed compilation issue for kernels > 2.6.15
  fixed compiler warning conditions
2006-08-29 08:57:02 +00:00
m. allan noah 5bbc2fef6c update to v1.0.41 2006-08-28 23:45:25 +00:00
Wittawat Yamwong 12bade88f5 * Removed Smartbase MP360 (supported by pixma backend) 2006-08-27 12:59:42 +00:00
Wittawat Yamwong 788b7eb0aa * add MP360,MP530 and MP800R product ID 2006-08-27 12:54:36 +00:00
Wittawat Yamwong 090ccc5e72 update 2006-08-27 12:44:35 +00:00
m. allan noah e47693e107 updated to v 1.0.40 2006-08-27 00:49:43 +00:00
Karl Heinz Kremer 0da1bfb49a Added V700/V750 scanner information 2006-08-23 21:45:51 +00:00
Eddy De Greef 0cbdbd66d1 doc/sane-mustek_pp.man: URL update. 2006-08-22 08:08:17 +00:00
Jon Chambers 5b5b49783f updated driver info 2006-08-12 12:59:40 +00:00
Gerhard Jaeger 7ab8ce6e13 * doc/plustek/Plustek-USB.changes: update.
* backend/plustek.c: bumped build number.
* backend/plustek-usbdevs.c: lowered speed for LiDE20/30 when
  using low resolutions.
* backend/plustek-usb.c: fixed warning condition.
2006-08-11 05:42:02 +00:00
Gerhard Jaeger 51780b8362 Updated comments. 2006-08-09 14:13:16 +00:00
Gerhard Jaeger 67ae886d9c * doc/plustek/Plustek-PARPORT.changes doc/plustek/Plustek-USB.changes
doc/u12/U12.changes: update.
* backend/artec_eplus48u.c backend/plustek.c backend/plustek_pp.c
  backend/u12.c: changed sane.type to "flatbed scanner" only.
* backend/plustek-usbdevs.c: fixed LiDE20/30 motor settings
2006-08-09 12:47:58 +00:00
Henning Geinitz 68983bed4e Updated info about plugins and other comments (patch from Olaf Meeuwissen
<olaf.meeuwissen@avasys.jp>).
2006-08-01 19:45:37 +00:00
m. allan noah 4d357d0fa1 updated to backend v1.0.39 2006-07-18 00:08:10 +00:00
m. allan noah 6a453bd191 update to backend v1.0.38 2006-07-15 15:15:52 +00:00
m. allan noah 8b9df6bcbf update to backend v1.0.37 2006-07-15 01:17:33 +00:00
m. allan noah 05aa6cc323 update to v1.0.36 2006-07-06 23:47:13 +00:00
m. allan noah cdbe31d245 update to backend v1.0.35 2006-07-05 22:46:42 +00:00
m. allan noah f9927937af update fujitsu backend to v 1.0.34 2006-07-05 00:42:05 +00:00
Wittawat Yamwong 4e7271defb Updated status of MP760 and MP780. 2006-07-01 12:21:22 +00:00
Gerhard Jaeger 3354675a85 * doc/plustek/Plustek-USB.changes: Update
* backend/plustek.c: Fixed problem when trying to select bit-depth.
2006-06-30 11:53:48 +00:00
Henning Geinitz d57dca63cb Typo fix. 2006-06-29 17:47:49 +00:00
m. allan noah b998ccced7 add S500 usb id and status. 2006-06-27 18:22:00 +00:00
m. allan noah b4d76b6923 update to backend v 1.0.33, add fi-5900 usb id, print sane version during
sane_init.
2006-06-24 17:48:53 +00:00