- use average instead of min/max for fine offset and gain
- rewrite supported resolution list as x and y arrays
- merge x and y resolution options into single option
- move scan params into two new structs, s->u and s->s
- sane_get_parameters() just returns values from s->u
- dont call wait_scanner() in object_position()
- dont call ssm_*() from option handler
- refactor sane_start()
- read_from_buffer() can workaround missing res, modes and cropping
- set most DR-2xxx machines to use the read_from_buffer workarounds
- set default threshold to 90
- add option for button #3 of some machines
- don't eject paper during init
- add DR-2010 quirks
- switch counter to HARD_SELECT, not SOFT
- Updated the list of supported devices (HP 5500C which is similar to
4570C, 5500C which is similar to 4500C) - only strings/comments, no
code was changed
- Updated backend version
- Updated man page
- Updated backend version
- Added HP ScanJet 4500C as completely supported
- Added HP ScanJet 5500C as untested
- HP ScanJet 4570C/5550C/5590/7650 marked as completely supported
* configure, configure.in: version 1.0.21cvs
* doc/releases.txt: minor updates for new build system
* doc/descriptions/canon_dr.desc, doc/descriptions/coolscan3.desc,
doc/descriptions/rts8891.desc, doc/descriptions/xerox_mfp.desc:
remove :new tag
with newer automake.
* backend/Makefile.am, tools/sane-config.in: Add missing
$GPHOTO2_LDFLAGS so library can be found.
* tools/Makefile.am: Add mising $SCSI_LIBS to sane-find-scanner.
doc/descriptions/fujitsu.desc: add S1500 usb ids and status
* backend/canon_dr.c: update credits
* doc/sane-fujitsu.man doc/sane-canon_dr.man: update version numbers,
dates, credits and known issues
* doc/saned.man: remove section about uncontrolled data port range
- return cmd status for reads of sensor options
* backend/canon_dr.c, doc/descriptions/canon_dr.desc: backend v26
- return cmd status for reads of sensor options
- allow rs to adjust read length for all bad status responses
- fix DR-2510C duplex deinterlacing code
- rewrite sane_read helpers to read until EOF
- update sane_start for scanners that dont use object_position
- dont call sanei_usb_clear_halt() if device is not open
- increase default buffer size to 4 megs
- set buffermode on by default
- hide modes and resolutions that DR-2510C lies about
- read_panel() logs front-end access to sensors instead of timing
- rewrite do_usb_cmd() to use remainder from RS info
* doc/desciptions/canon_dr.desc: backend v24, update DR-2510C comment
- rewrite all image data processing code
- handle more image interlacing formats
- re-enable binary mode on some scanners
- limit some machines to full-width scanning
* doc/desciptions/canon_dr.desc: v23, improved comments
- pad gray deinterlacing area for DR-2510C
- override tl_x and br_x for fixed width scanners
* doc/descriptions/canon_dr.desc: backend v19, update comments
- add byte-oriented duplex interlace code
- add RRGGBB color interlace code
- add basic support for DR-2580C, DR-2050C, DR-2080C, DR-2510C
- add more unknown setwindow bits
- add support for 16 byte status packets
- clean do_usb_cmd error handling (call reset more often)
- set status packet size from config file
- rewrite config file parsing to reset options after each scanner
- add config options for vendor, model, version
- dont call inquiry if those 3 options are set
- remove default config file from code
- add initial gray deinterlacing code for DR-2510C
- rename do_usb_reset to do_usb_clear
* doc/descriptions/canon_dr.desc: backend v18, update model status
* backend/canon_dr.conf.in: added better comments and new options
to sane-config missed during fix to stop using LIBS to link everything.
Add back in code to move LDFLAGS out of $GPHOTO2_LIBS and into
GPHOTO2_LDFLAGS.