gb-schematics/AGS-CPU-11/CHANGELOG.markdown

881 B

Change Log

[Unreleased]

Rev E - 2023-07-18

Changed

  • Upgrade to KiCad 7.0 file formats
  • Remove Farad/Henry units since it's obvious (e.g. 100nF -> 100n)

Rev D - 2022-01-02

Added

  • Voltage ratings of electrolytic capacitor CP1

Changed

  • Upgraded to KiCad 6.0 file formats
  • Removed test point references, since they're not present on the original board and cause confusion with TP0-9 button signals

Rev C - 2021-07-26

Fixed

  • Location of pull-up resistor R7. It's on the SoC side before the series resistor array RA1
  • Capacitor C2 value. 34pF is not a standard value, and apparently AGB uses the exactly same circuit and 33pF -> most likely it's 33pF in AGS too.

Rev B - 2021-03-03

Added

  • Proper symbol for transformer T1

Fixed

  • Incorrect pinout of transistor Q1

Rev A - 2020-10-16

Added

  • Initial release