gb-schematics/AGS-CPU-11/CHANGELOG.markdown

46 wiersze
881 B
Markdown

2021-07-26 15:36:46 +00:00
# Change Log
## [Unreleased]
2023-07-18 17:49:31 +00:00
## Rev E - 2023-07-18
2023-07-13 07:51:12 +00:00
### Changed
- Upgrade to KiCad 7.0 file formats
2023-07-13 07:54:52 +00:00
- Remove Farad/Henry units since it's obvious (e.g. 100nF -> 100n)
2023-07-13 07:51:12 +00:00
2022-01-02 11:49:09 +00:00
## Rev D - 2022-01-02
### Added
- Voltage ratings of electrolytic capacitor CP1
### Changed
- Upgraded to KiCad 6.0 file formats
- Removed test point references, since they're not present on
the original board and cause confusion with TP0-9 button signals
2021-07-26 15:36:46 +00:00
## Rev C - 2021-07-26
### Fixed
- Location of pull-up resistor R7. It's on the SoC side *before* the series resistor array RA1
- Capacitor C2 value. 34pF is not a standard value, and apparently AGB uses the exactly same circuit and 33pF -> most likely it's 33pF in AGS too.
## Rev B - 2021-03-03
### Added
- Proper symbol for transformer T1
### Fixed
- Incorrect pinout of transistor Q1
## Rev A - 2020-10-16
### Added
- Initial release