Hamlib/tests/rotctl.1

286 wiersze
10 KiB
Groff
Czysty Zwykły widok Historia

.\" Hey, EMACS: -*- nroff -*-
.\" First parameter, NAME, should be all caps
.\" Second parameter, SECTION, should be 1-8, maybe w/ subsection
.\" other parameters are allowed: see man(7), man(1)
.TH ROTCTL "1" "April 25, 2010" "Hamlib" "Rotator Control Program"
.\" Please adjust this date whenever revising the manpage.
.\"
.\" Some roff macros, for reference:
.\" .nh disable hyphenation
.\" .hy enable hyphenation
.\" .ad l left justify
.\" .ad b justify to both left and right margins
.\" .nf disable filling
.\" .fi enable filling
.\" .br insert line break
.\" .sp <n> insert n+1 empty lines
.\" for manpage-specific macros, see man(7)
.SH NAME
rotctl \- control antenna rotators
.SH SYNOPSIS
.B rotctl
[\fIOPTION\fR]... [\fICOMMAND\fR]...
.SH DESCRIPTION
Control antenna rotators.
\fBrotctl\fP accepts \fIcommands\fP from the command line as well as in
interactive mode if none are provided on the command line.
.PP
.\" TeX users may be more comfortable with the \fB<whatever>\fP and
.\" \fI<whatever>\fP escape sequences to invode bold face and italics,
.\" respectively.
Keep in mind that \fBHamlib\fP is BETA level software.
While a lot of backend libraries lack complete rig support, the basic functions
are usually well supported. The API may change without publicized notice,
while an advancement of the minor version (e.g. 1.1.x to 1.2.x) indicates such
a change.
.PP
Please report bugs and provide feedback at the e-mail address given in the
REPORTING BUGS section. Patches and code enhancements are also welcome.
.SH OPTIONS
This program follows the usual GNU command line syntax, with long
options starting with two dashes (`-').
Here is s summary of the supported options:
.TP
.B \-m, --model=id
Select rotator model number. See model list (use 'rotctl -l').
.sp
NB: \fBrotctl\fP (or third party software) will use rig model 1901
when using \fBrpc.rotd\fP or rig model 2 for NET rotctl (rotctld).
.TP
.B \-r, --rot-file=device
Use \fIdevice\fP as the file name of the port the rotator is connected.
Often a serial port, but could be a USB to serial adapter or USB port device.
Typically /dev/ttyS0, /dev/ttyS1, /dev/ttyUSB0, etc.
.sp
Default is \fB/dev/rotator\fP (may be a symbolic link to the actual device).
.TP
.B \-s, --serial-speed=baud
Set serial speed to \fIbaud\fP rate. Uses maximum serial speed from rotator
backend capabilites as default.
.TP
.B \-t, --send-cmd-term=char
Change the termination \fIchar\fP for text protocol when using the \fIsend_cmd\fP command.
The default value is <CR>. Non ASCII printable characters can be specified as an
ASCII number, in hexadecimal format, prepended with 0x. You may pass an empty string
for no termination char. The string -1 tells rotctl to switch to binary protocol.
See the \fIsend_cmd\fP command for further explanation.
.TP
.B \-L, --show-conf
List all config parameters for the rotor defined with -m above.
.TP
.B \-C, --set-conf=parm=val[,parm=val]*
Set config parameter. e.g. --set_conf=stop_bits=2
.sp
Use -L option for a list.
.TP
.B \-u, --dump-caps
Dump capabilities for the rotor defined with -m above and exit.
.TP
.B \-l, --list
List all model numbers defined in \fBHamlib\fP and exit.
.TP
.B \-v, --verbose
Set verbose mode, cumulative (see DIAGNOSTICS below).
.TP
.B \-h, --help
Show summary of these options and exit.
.TP
.B \-V, \-\-version
Show version of \fBrotctl\fP and exit.
.PP
\fBN.B.\fP Some options may not be implemented by a given backend and will
return an error. This is most likely to occur with the \fI\-\-set-conf\fP
and \fI\-\-show-conf\fP options.
.PP
Please note that the backend for the rotator to be controlled,
or the rotator itself may not support some commands. In that case,
the operation will fail with a \fBHamlib\fP error code.
.SH COMMANDS
Commands can be entered either as a single char, or as a long command name.
Basically, the commands do not take a dash in front of them, as
the options do. They may be typed in when in interactive mode
or provided as argument(s) in command line interface mode.
.PP
Since most of the \fBHamlib\fP operations have a \fIset\fP and a \fIget\fP method,
an upper case letter will be used for \fIset\fP method whereas the
corresponding lower case letter refers to the \fIget\fP method. Each operation
also has a long name; in interactive mode, prepend a backslash to enter a long
command name.
.sp
Example: Use "\\get_info" to see the rotor's info.
.PP
Please note that the backend for the rotator to be controlled,
or the rotator itself may not support some commands. In that case,
the operation will fail with a \fBHamlib\fP error message.
.PP
A summary of commands is included below (In the case of "set" commands the
quoted string is replaced by the value in the description. In the case of "get"
commands the quoted string is the key name of the value returned.):
.TP
.B P, set_pos 'Azimuth' 'Elevation'
Set position: Azimuth and Elevation as double precision floating point values.
.TP
.B p, get_pos
Get position: 'Azimuth' and 'Elevation' as double precision floating point values.
.TP
.B M, move 'Direction' 'Speed'
Move the rotator in a specific direction at the given rate.
.sp
Values are integers where Direction is defined as 2 = Up, 4 = Down, 8 = Left,
and 16 = Right. Speed is an integer between 1 and 100. Not all backends that
implement the move command use the Speed value. At this time only the gs232a
utilizes the Speed parameter.
.TP
.B S, stop
Stop the rotator.
.TP
.B K, park
Park the antenna.
.TP
.B C, set_conf 'Token' 'Value'
Set a configuration parameter. It is safe to give "Token" a value of '0'
(zero). "Value" may be a string up to 20 characters.
.br
See -L output
.TP
.B R, reset 'Reset'
Reset the rotator.
.sp
Integer value of '1' for Reset All.
.TP
.B _, get_info
Get misc information on the rotator.
.sp
At the moment returns 'Model Name'.
.TP
.B w, send_cmd 'Cmd'
Send raw command string to the rotator.
.br
<CR> (or send-cmd-term, see \fI-t\fP option) is appended automatically at the end
of the command for text protocols.
For binary protocols, enter values as \\0xAA\\0xBB
.PP
\fBLocator Commands\fP
.PP
These commands offer conversions of Degrees Minutes Seconds to other formats,
Maidenhead square locator conversions and distance and azimuth conversions.
.TP
.B L, lonlat2loc 'Longitude' 'Latitude' 'Loc Len [2-12]'
Returns the Maidenhead locator for the given 'Longitude' and 'Latitude'.
.sp
Both are floating point values. The precision of the returned square is
controlled by 'Loc Len' which should be an even numbered integer value between
2 and 12.
.sp
For example, "+L -170.000000 -85.000000 12\\n" returns "Locator: AA55AA00AA00\\n".
.TP
.B l, loc2lonlat 'Locator'
Returns 'Longitude' and 'Latitude' in decimal degrees at the approximate
center of the requested grid square (despite the use of double precision
variables internally, some rounding error occurs). West longitude is
expressed as a negative value. South latitude is expressed as a negative
value. Locator can be from 2 to 12 characters in length.
.sp
For example, "+l AA55AA00AA00\\n" returns "Longitude: -169.999983\\nLatitude:
-84.999991\\n".
.TP
.B D, dms2dec 'Degrees' 'Minutes' 'Seconds' 'S/W'
Returns 'Dec Degrees', a signed floating point value.
.sp
Degrees and Minutes are
integer values and Seconds is a floating point value. S/W is a flag with '1'
indicating South latitude or West longitude and '0' North or East (the flag is
needed as computers don't recognize a signed zero even though only the Degrees
value only is typically signed in DMS notation).
.TP
.B d, dec2dms 'Dec Degrees'
Returns 'Degrees' 'Minutes' 'Seconds' 'S/W'.
.sp
Values are as in dms2dec above.
.TP
.B E, dmmm2dec 'Degrees' 'Dec Minutes' 'S/W'
Returns 'Dec Degrees', a signed floating point value.
.sp
Degrees is an integer
value and Minutes is a floating point value. S/W is a flag with '1'
indicating South latitude or West longitude and '0' North or East (the flag is
needed as computers don't recognize a signed zero even though only the Degrees
value only is typically signed in DMS notation).
.TP
.B e, dec2dmmm 'Dec Deg'
Returns 'Degrees' 'Minutes' 'S/W'.
.sp
Values are as in dmmm2dec above.
.TP
.B B, qrb 'Lon 1' 'Lat 1' 'Lon 2' 'Lat 2'
Returns 'Distance' 'Azimuth' where Distance is in km and Azimuth is in degrees.
.sp
All Lon/Lat values are signed floating point numbers.
.TP
.B A, a_sp2a_lp 'Short Path Deg'
Returns 'Long Path Deg' or -RIG_EINVAL upon input error..
.sp
Both are floating point values within the range 0.00 to 360.00.
.TP
.B a, d_sp2d_lp 'Short Path km'
Returns 'Long Path km'.
.sp
Both are floating point values.
.SH EXAMPLES
Start \fBrotctl\fP for RotorEZ using COM1:
.sp
$ rotctl -m 401 -r /dev/ttyS0
.sp
Start \fBrotctl\fP using \fBrpc.rotd\fP and querying the position:
.sp
$ rotctl -m 101 -r localhost \\get_pos
.sp
Connect to a running \fBrotctld\fP with rotor model 2 ("NET rotctl") on the
local host and specifying the TCP port:
.sp
$ rotctl -m 2 -r localhost:4533
.SH DIAGNOSTICS
The \fB-v\fP, \fB--version\fP option allows different levels of diagnostics
to be output to \fBstderr\fP and correspond to -v for BUG, -vv for ERR,
-vvv for WARN, -vvvv for VERBOSE, or -vvvvv for TRACE.
.PP
A given verbose level is useful for providing needed debugging information to
the email address below. For example, TRACE output shows all of the values
sent to and received from the radio which is very useful for radio backend
library development and may be requested by the developers.
.SH EXIT STATUS
\fBrotctl\fP exits with:
.br
0 if all operations completed normally;
.br
1 if there was an invalid command line option or argument;
.br
2 if an error was returned by \fBHamlib\fP.
.SH BUGS
.PP
This suspiciously empty section...
.SH REPORTING BUGS
Report bugs to <hamlib-developer@lists.sourceforge.net>.
.PP
We are already aware of the bug in the previous section :-)
.SH AUTHOR
Written by Stephane Fillod, Nate Bargmann, and the Hamlib Group
.PP
<http://www.hamlib.org>.
.SH COPYRIGHT
Copyright \(co 2000-2010 Stephane Fillod
.br
Copyright \(co 2010 Nate Bargmann
.br
Copyright \(co 2000-2010 the Hamlib Group
.PP
This is free software; see the source for copying conditions.
There is NO warranty; not even for MERCHANTABILITY
or FITNESS FOR A PARTICULAR PURPOSE.
.SH SEE ALSO
.BR hamlib (3),
.BR rpc.rotd (8)
.BR rotctld (8)