# wmbusmeters
|
|
The program receives and decodes C1 or T1 telegrams
|
|
(using the wireless mbus protocol) to acquire
|
|
utility meter readings. The readings can then be published using
|
|
MQTT, inserted into a database or stored in a log file.
|
|
|
|
The program runs on GNU/Linux (standard x86) and Raspberry Pi (arm).
|
|
|
|
| OS | Status |
|
|
| ------------ |:-------------:|
|
|
|GNU/Linux & MacOSX| [![Build Status](https://travis-ci.org/weetmuts/wmbusmeters.svg?branch=master)](https://travis-ci.org/weetmuts/wmbusmeters) |
|
|
|
|
| Static Scan | Status |
|
|
| ------------- |:-------------:|
|
|
|Linux G++| [![Build Status](https://scan.coverity.com/projects/14774/badge.svg)](https://scan.coverity.com/projects/weetmuts-wmbusmeters) |
|
|
|
|
|
|
```
|
|
wmbusmeters version: 0.8
|
|
Usage: wmbusmeters {options} (auto | /dev/ttyUSBx)] { [meter_name] [meter_type] [meter_id] [meter_key] }*
|
|
|
|
Add more meter quadruplets to listen to more meters.
|
|
Add --verbose for detailed debug information.
|
|
--robot or --robot=json for json output.
|
|
--robot=fields for semicolon separated fields.
|
|
--separator=X change field separator to X.
|
|
--logfile=file
|
|
--meterfiles=dir to create status files below dir,
|
|
named dir/meter_name, containing the latest reading.
|
|
--meterfiles defaults dir to /tmp.
|
|
--c1 or --t1 listen to C1 or T1 messages
|
|
--shell=cmd invokes cmd with env variables containing the latest reading.
|
|
--shellenvs list the env variables available for the meter.
|
|
--oneshot wait for an update from each meter, then quit.
|
|
--exitafter=20h program exits after running for twenty hours,
|
|
or 10m for ten minutes or 5s for five seconds.
|
|
|
|
Specifying auto as the device will automatically look for usb
|
|
wmbus dongles on /dev/im871a and /dev/amb8465.
|
|
|
|
Supported water meters:
|
|
Kamstrup Multical 21 (multical21)
|
|
Kamstrup flowIQ 3100 (flowiq3100)
|
|
Sontex Supercom 587 (supercom587)
|
|
Sensus iPERL (iperl)
|
|
|
|
Work in progress:
|
|
Heat meter Kamstrup Multical 302 (multical302)
|
|
Electricity meter Kamstrup Omnipower (omnipower)
|
|
Heat cost allocator Qundis Q caloric (qcaloric)
|
|
```
|
|
|
|
No meter quadruplets means listen for telegram traffic and print any id heard,
|
|
but you have to specify if you want to listen using radio mode C1 or T1. E.g.
|
|
|
|
```
|
|
wmbusmeters --t1 /dev/ttyUSB0
|
|
```
|
|
|
|
You can listen to multiple meters as long as they all require the same radio mode C1 or T1.
|
|
So (currently) you cannot listen to a multical21 and a supercom587 with a single dongle at the same time.
|
|
|
|
# Usage examples
|
|
|
|
```
|
|
wmbusmeters /dev/ttyUSB0 MyTapWater multical21 12345678 00112233445566778899AABBCCDDEEFF
|
|
```
|
|
|
|
wmbusmeters will detect which kind of dongle is connected to /dev/ttyUSB0. It can be either an IMST 871a dongle or an Amber Wireless AMB8465. If you have setup the udev rules below, then you can use auto instead of /dev/ttyUSB0.
|
|
|
|
Example output:
|
|
|
|
`MyTapWater 12345678 6.388 m3 6.377 m3 0.000 m3/h 8°C 23°C DRY(dry 22-31 days) 2018-03-05 12:02.50`
|
|
|
|
(Here the multical21 itself, is configured to send target volume, therefore the max flow is 0.000 m3/h.)
|
|
|
|
Example robot json output:
|
|
|
|
`wmbusmeters --robot=json auto MyTapWater multical21 12345678 00112233445566778899AABBCCDDEEFF MyHeater multical302 22222222 00112233445566778899AABBCCDDEEFF`
|
|
|
|
`{"media":"cold water","meter":"multical21","name":"MyTapWater","id":"12345678","total_m3":6.388,"target_m3":6.377,"max_flow_m3h":0.000,"flow_temperature":8,"external_temperature":23,"current_status":"DRY","time_dry":"22-31 days","time_reversed":"","time_leaking":"","time_bursting":"","timestamp":"2018-02-08T09:07:22Z"}`
|
|
|
|
`{"media":"heat","meter":"multical302","name":"MyHeater","id":"22222222","total_kwh":0.000,"total_volume_m3":0.000,"current_kw":"0.000","timestamp":"2018-02-08T09:07:22Z"}`
|
|
|
|
Example robot fields output:
|
|
|
|
`wmbusmeters --robot=fields auto GreenhouseWater multical21 33333333 ""`
|
|
|
|
`GreenhouseTapWater;33333333;9999.099;77.712;0.000;11;31;;2018-03-05 12:10.24`
|
|
|
|
Eaxmple of using the shell command to publish to MQTT:
|
|
|
|
`wmbusmeters --shell='HOME=/home/you mosquitto_pub -h localhost -t water -m "$METER_JSON"' auto GreenhouseWater multical21 33333333 ""`
|
|
|
|
Eaxmple of using the shell command to inject data into postgresql database:
|
|
|
|
`wmbusmeters --shell="psql waterreadings -c \"insert into readings values ('\$METER_ID',\$METER_TOTAL_M3,'\$METER_TIMESTAMP') \" " auto MyColdWater multical21 12345678 ""`
|
|
|
|
You can have multiple shell commands and they will be executed in the order you gave them on the commandline.
|
|
Note that to single quotes around the command is necessary to pass the env variable names into wmbusmeters.
|
|
|
|
You can use `--debug` to get both verbose output and the actual data bytes sent back and forth with the wmbus usb dongle.
|
|
|
|
If the meter does not use encryption of its meter data, then enter an empty key on the command line.
|
|
(you must enter "")
|
|
|
|
`wmbusmeters --robot --meterfiles auto MyTapWater multical21 12345678 ""`
|
|
|
|
If you have a Multical21 meter and you have received a KEM file and its password,
|
|
from your water municipality, then you can use the XMLExtract.java utility to get
|
|
the meter key from the KEM file. You need to unzip the the KEM file first though,
|
|
if it is zipped.
|
|
|
|
You can run wmbusmeters with --logtelegrams to get log output that can be placed in a simulation.txt
|
|
file. You can then run wmbusmeter and instead of auto (or an usb device) provide the simulationt.xt
|
|
file as argument. See test.sh for more info.
|
|
|
|
# Builds and runs on GNU/Linux:
|
|
|
|
`make && make test`
|
|
|
|
Binary generated: `./build/wmbusmeters`
|
|
|
|
`make HOST=arm`
|
|
|
|
Binary generated: `./build_arm/wmbusmeters`
|
|
|
|
`make DEBUG=true`
|
|
|
|
Binary generated: `./build_debug/wmbusmeters`
|
|
|
|
`make DEBUG=true HOST=arm`
|
|
|
|
Binary generated: `./build_arm_debug/wmbusmeters`
|
|
|
|
`make HOST=arm dist`
|
|
|
|
(Work in progress...)
|
|
Binary generated: `./wmbusmeters_0.8_armhf.deb`
|
|
|
|
# System configuration
|
|
|
|
Add yourself to the dialout group to get access to the newly plugged in im871A USB stick.
|
|
Or even better, add this udev rule:
|
|
|
|
Create the file: `/etc/udev/rules.d/99-usb-serial.rules` with the content
|
|
```
|
|
SUBSYSTEM=="tty", ATTRS{idVendor}=="10c4", ATTRS{idProduct}=="ea60", SYMLINK+="im871a",MODE="0660", GROUP="yourowngroup"
|
|
SUBSYSTEM=="tty", ATTRS{idVendor}=="0403", ATTRS{idProduct}=="6001", SYMLINK+="amb8465",MODE="0660", GROUP="yourowngroup"
|
|
```
|
|
|
|
When you insert the wmbus USB dongle, a properly named symlink will be
|
|
created: either `/dev/im871a` or `/dev/amb8465`. These symlinks are
|
|
necessary if you want to pass "auto" to wmbusmeters instead of the
|
|
exact serial port /dev/ttyUSBx.
|
|
|
|
# Source code
|
|
|
|
The source code is modular and it should be relatively straightforward to add more receivers and meters.
|
|
|
|
Read for example the text file: HowToAddaNewMeter.txt
|
|
|
|
# Good documents on the wireless mbus protocol:
|
|
|
|
https://oms-group.org/download4all/
|
|
|
|
http://www.m-bus.com/files/w4b21021.pdf
|
|
|
|
https://www.infineon.com/dgdl/TDA5340_AN_WMBus_v1.0.pdf
|
|
|
|
http://fastforward.ag/downloads/docu/FAST_EnergyCam-Protocol-wirelessMBUS.pdf
|
|
|
|
http://www.multical.hu/WiredMBus-water.pdf
|
|
|
|
http://uu.diva-portal.org/smash/get/diva2:847898/FULLTEXT02.pdf
|
|
|
|
http://projekter.aau.dk/projekter/da/studentthesis/wireless-mbus-based-extremely-low-power-protocol-for-wireless-communication-with-water-meters(6e1139d5-6f24-4b8a-a727-9bc108012bcc).html
|
|
|
|
The AES source code is copied from:
|
|
|
|
https://github.com/kokke/tiny-AES128-C
|
|
|
|
TODO: CRC checks are still missing. If the wrong AES key
|
|
is supplied you probably get zero readings and
|
|
sometimes warnings about wrong type of frames.
|
|
|
|
There is also a lot of wmbus protocol implementation details that
|
|
probably are missing. They will be added to the program
|
|
as we figure out how the meters send their data.
|