// List of numbers that can be used to detect the meter driver from a telegram.
|
|
|
|
//
|
|
|
|
// meter driver, manufacturer, media, version
|
|
|
|
//
|
|
|
|
#define METER_DETECTION \
|
|
|
|
X(AMIPLUS, MANUFACTURER_APA, 0x02, 0x02) \
|
|
|
|
X(AMIPLUS, MANUFACTURER_DEV, 0x37, 0x02) \
|
|
|
|
X(AMIPLUS, MANUFACTURER_DEV, 0x02, 0x00) \
|
|
|
|
X(APATOR08, 0x8614/*APT?*/, 0x03, 0x03) \
|
|
|
|
X(APATOR162, MANUFACTURER_APA, 0x06, 0x05) \
|
|
|
|
X(APATOR162, MANUFACTURER_APA, 0x07, 0x05) \
|
|
|
|
X(CMA12W, MANUFACTURER_ELV, 0x1b, 0x20) \
|
|
|
|
X(COMPACT5, MANUFACTURER_TCH, 0x04, 0x45) \
|
|
|
|
X(COMPACT5, MANUFACTURER_TCH, 0xc3, 0x45) \
|
|
|
|
X(COMPACT5, MANUFACTURER_TCH, 0x43, 0x22) \
|
|
|
|
X(COMPACT5, MANUFACTURER_TCH, 0x43, 0x45) \
|
2021-04-10 15:58:32 +00:00
|
|
|
X(DME_07, MANUFACTURER_DME, 0x07, 0x7b) \
|
2021-03-07 19:10:44 +00:00
|
|
|
X(EBZWMBE, MANUFACTURER_EBZ, 0x37, 0x02) \
|
|
|
|
X(EURISII, MANUFACTURER_INE, 0x08, 0x55) \
|
|
|
|
X(EHZP, MANUFACTURER_EMH, 0x02, 0x02) \
|
|
|
|
X(ESYSWM, MANUFACTURER_ESY, 0x37, 0x30) \
|
|
|
|
X(FLOWIQ2200,MANUFACTURER_KAW, 0x16, 0x3a) \
|
|
|
|
X(FLOWIQ3100,MANUFACTURER_KAM, 0x16, 0x1d) \
|
|
|
|
X(ELF, MANUFACTURER_APA, 0x04, 0x40) \
|
|
|
|
X(EM24, MANUFACTURER_KAM, 0x02, 0x33) \
|
|
|
|
X(EMERLIN868,MANUFACTURER_ELR, 0x37, 0x11) \
|
|
|
|
X(EV200, MANUFACTURER_ELR, 0x07, 0x0d) \
|
|
|
|
X(EVO868, MANUFACTURER_MAD, 0x07, 0x50) \
|
|
|
|
X(FHKVDATAIII,MANUFACTURER_TCH, 0x80, 0x69) \
|
|
|
|
X(FHKVDATAIII,MANUFACTURER_TCH, 0x80, 0x94) \
|
|
|
|
X(FHKVDATAIV,MANUFACTURER_TCH, 0x08, 0x69) \
|
|
|
|
X(FHKVDATAIV,MANUFACTURER_TCH, 0x08, 0x94) \
|
|
|
|
X(HYDRUS, MANUFACTURER_DME, 0x07, 0x70) \
|
|
|
|
X(HYDRUS, MANUFACTURER_HYD, 0x07, 0x24) \
|
|
|
|
X(HYDRUS, MANUFACTURER_DME, 0x06, 0x70) \
|
|
|
|
X(HYDRUS, MANUFACTURER_DME, 0x16, 0x70) \
|
|
|
|
X(HYDROCALM3,MANUFACTURER_BMT, 0x0d, 0x0b) \
|
|
|
|
X(HYDRODIGIT,MANUFACTURER_BMT, 0x07, 0x13) \
|
|
|
|
X(EI6500, MANUFACTURER_EIE, 0x1a, 0x0c) \
|
|
|
|
X(IPERL, MANUFACTURER_SEN, 0x06, 0x68) \
|
|
|
|
X(IPERL, MANUFACTURER_SEN, 0x07, 0x68) \
|
|
|
|
X(IPERL, MANUFACTURER_SEN, 0x07, 0x7c) \
|
|
|
|
X(IZAR, MANUFACTURER_SAP, 0x15, -1) \
|
|
|
|
X(IZAR, MANUFACTURER_SAP, 0x04, -1) \
|
|
|
|
X(IZAR, MANUFACTURER_SAP, 0x07, 0x00) \
|
|
|
|
X(IZAR, MANUFACTURER_DME, 0x07, 0x78) \
|
|
|
|
X(IZAR3, MANUFACTURER_SAP, 0x00, 0x88) \
|
|
|
|
X(LANSENSM, MANUFACTURER_LAS, 0x1a, 0x03) \
|
|
|
|
X(LANSENTH, MANUFACTURER_LAS, 0x1b, 0x07) \
|
|
|
|
X(LANSENDW, MANUFACTURER_LAS, 0x1d, 0x07) \
|
|
|
|
X(LANSENPU, MANUFACTURER_LAS, 0x00, 0x14) \
|
|
|
|
X(LANSENPU, MANUFACTURER_LAS, 0x00, 0x0b) \
|
2021-04-13 09:00:57 +00:00
|
|
|
X(LSE_07_17, MANUFACTURER_LSE, 0x07, 0x17) \
|
2021-03-07 19:10:44 +00:00
|
|
|
X(MKRADIO3, MANUFACTURER_TCH, 0x62, 0x74) \
|
|
|
|
X(MKRADIO3, MANUFACTURER_TCH, 0x72, 0x74) \
|
|
|
|
X(MKRADIO4, MANUFACTURER_TCH, 0x62, 0x95) \
|
|
|
|
X(MKRADIO4, MANUFACTURER_TCH, 0x62, 0x70) \
|
|
|
|
X(MKRADIO4, MANUFACTURER_TCH, 0x72, 0x95) \
|
|
|
|
X(MKRADIO4, MANUFACTURER_TCH, 0x72, 0x70) \
|
|
|
|
X(MULTICAL21, MANUFACTURER_KAM, 0x06, 0x1b) \
|
|
|
|
X(MULTICAL21, MANUFACTURER_KAM, 0x16, 0x1b) \
|
|
|
|
X(MULTICAL302,MANUFACTURER_KAM, 0x04, 0x30) \
|
|
|
|
X(MULTICAL302,MANUFACTURER_KAM, 0x0d, 0x30) \
|
|
|
|
X(MULTICAL403,MANUFACTURER_KAM, 0x0a, 0x34) \
|
|
|
|
X(MULTICAL403,MANUFACTURER_KAM, 0x0b, 0x34) \
|
|
|
|
X(MULTICAL403,MANUFACTURER_KAM, 0x0c, 0x34) \
|
|
|
|
X(MULTICAL403,MANUFACTURER_KAM, 0x0d, 0x34) \
|
|
|
|
X(MULTICAL603,MANUFACTURER_KAM, 0x04, 0x35) \
|
|
|
|
X(MULTICAL803,MANUFACTURER_KAM, 0x04, 0x39) \
|
|
|
|
X(OMNIPOWER, MANUFACTURER_KAM, 0x02, 0x30) \
|
|
|
|
X(RFMAMB, MANUFACTURER_BMT, 0x1b, 0x10) \
|
|
|
|
X(RFMTX1, MANUFACTURER_BMT, 0x07, 0x05) \
|
|
|
|
X(TSD2, MANUFACTURER_TCH, 0xf0, 0x76) \
|
|
|
|
X(Q400, MANUFACTURER_AXI, 0x07, 0x10) \
|
|
|
|
X(QCALORIC, MANUFACTURER_QDS, 0x08, 0x35) \
|
|
|
|
X(SHARKY, MANUFACTURER_HYD, 0x04, 0x20) \
|
|
|
|
X(SUPERCOM587,MANUFACTURER_SON, 0x06, 0x3c) \
|
|
|
|
X(SUPERCOM587,MANUFACTURER_SON, 0x07, 0x3c) \
|
|
|
|
X(SONTEX868, MANUFACTURER_SON, 0x08, 0x16) \
|
|
|
|
X(TOPASESKR, MANUFACTURER_AMT, 0x06, 0xf1) \
|
|
|
|
X(TOPASESKR, MANUFACTURER_AMT, 0x07, 0xf1) \
|
|
|
|
X(ULTRIMIS, MANUFACTURER_APA, 0x16, 0x01) \
|
|
|
|
X(VARIO451, MANUFACTURER_TCH, 0x04, 0x27) \
|
|
|
|
X(VARIO451, MANUFACTURER_TCH, 0xc3, 0x27) \
|
|
|
|
X(WATERSTARM, MANUFACTURER_DWZ, 0x06, 0x02) \
|
|
|
|
X(WATERSTARM, MANUFACTURER_DWZ, 0x07, 0x02) \
|
|
|
|
X(WATERSTARM, MANUFACTURER_EFE, 0x07, 0x03) \
|
|
|
|
X(WHE46X, MANUFACTURER_LSE, 0x08, 0x18) \
|
|
|
|
X(WHE5X, MANUFACTURER_LSE, 0x08, 0x34) \
|
|
|
|
X(SENSOSTAR, MANUFACTURER_EFE, 0x04, 0x00) \
|
|
|
|
X(CCx01, MANUFACTURER_GSS, 0x02, 0x01) \
|
|
|
|
X(LSE_08, MANUFACTURER_LSE, 0x08, 0x01) \
|
|
|
|
X(WEH_07, MANUFACTURER_WEH, 0x07, 0xfe) \
|
|
|
|
|
|
|
|
|
|
|
|