Rename qwater55 to lse_07_17

pull/278/head
mblnk 2021-04-13 11:00:57 +02:00
rodzic 403017f640
commit 397bd7d3d8
4 zmienionych plików z 36 dodań i 36 usunięć

Wyświetl plik

@ -170,6 +170,7 @@ METER_OBJS:=\
$(BUILD)/meter_lansensm.o \
$(BUILD)/meter_lansenth.o \
$(BUILD)/meter_lansenpu.o \
$(BUILD)/meter_lse_07_17.o \
$(BUILD)/meter_mkradio3.o \
$(BUILD)/meter_mkradio4.o \
$(BUILD)/meter_multical21.o \
@ -181,7 +182,6 @@ METER_OBJS:=\
$(BUILD)/meter_piigth.o \
$(BUILD)/meter_q400.o \
$(BUILD)/meter_qcaloric.o \
$(BUILD)/meter_qwater55.o \
$(BUILD)/meter_rfmamb.o \
$(BUILD)/meter_rfmtx1.o \
$(BUILD)/meter_sharky.o \

Wyświetl plik

@ -69,6 +69,7 @@
X(LANSENDW, MANUFACTURER_LAS, 0x1d, 0x07) \
X(LANSENPU, MANUFACTURER_LAS, 0x00, 0x14) \
X(LANSENPU, MANUFACTURER_LAS, 0x00, 0x0b) \
X(LSE_07_17, MANUFACTURER_LSE, 0x07, 0x17) \
X(MKRADIO3, MANUFACTURER_TCH, 0x62, 0x74) \
X(MKRADIO3, MANUFACTURER_TCH, 0x72, 0x74) \
X(MKRADIO4, MANUFACTURER_TCH, 0x62, 0x95) \
@ -91,7 +92,6 @@
X(TSD2, MANUFACTURER_TCH, 0xf0, 0x76) \
X(Q400, MANUFACTURER_AXI, 0x07, 0x10) \
X(QCALORIC, MANUFACTURER_QDS, 0x08, 0x35) \
X(QWATER55, MANUFACTURER_LSE, 0x07, 0x17) \
X(SHARKY, MANUFACTURER_HYD, 0x04, 0x20) \
X(SUPERCOM587,MANUFACTURER_SON, 0x06, 0x3c) \
X(SUPERCOM587,MANUFACTURER_SON, 0x07, 0x3c) \

Wyświetl plik

@ -24,8 +24,8 @@
using namespace std;
struct MeterQWater55 : public virtual WaterMeter, public virtual MeterCommonImplementation {
MeterQWater55(MeterInfo &mi);
struct MeterLSE_07_17 : public virtual WaterMeter, public virtual MeterCommonImplementation {
MeterLSE_07_17(MeterInfo &mi);
// Total water counted through the meter
double totalWaterConsumption(Unit u);
@ -59,13 +59,13 @@ private:
};
shared_ptr<WaterMeter> createQWater55(MeterInfo &mi)
shared_ptr<WaterMeter> createLSE_07_17(MeterInfo &mi)
{
return shared_ptr<WaterMeter>(new MeterQWater55(mi));
return shared_ptr<WaterMeter>(new MeterLSE_07_17(mi));
}
MeterQWater55::MeterQWater55(MeterInfo &mi) :
MeterCommonImplementation(mi, MeterDriver::QWATER55)
MeterLSE_07_17::MeterLSE_07_17(MeterInfo &mi) :
MeterCommonImplementation(mi, MeterDriver::LSE_07_17)
{
setExpectedTPLSecurityMode(TPLSecurityMode::AES_CBC_IV);
@ -98,7 +98,7 @@ MeterQWater55::MeterQWater55(MeterInfo &mi) :
}
void MeterQWater55::processContent(Telegram *t)
void MeterLSE_07_17::processContent(Telegram *t)
{
/*
The following telegram corresponds to the Qundis QWater5.5 cold water meters I have here.
@ -110,25 +110,25 @@ void MeterQWater55::processContent(Telegram *t)
Even though my meters are definitely Qundis QWater5.5, the meters do not identify with
manufacturer code QDS but with LSE.
(qwater55) 0f: 0C dif (8 digit BCD Instantaneous value)
(qwater55) 10: 13 vif (Volume l)
(qwater55) 11: * 04400100 total consumption (14.004000 m3)
(qwater55) 15: 4C dif (8 digit BCD Instantaneous value storagenr=1)
(qwater55) 16: 13 vif (Volume l)
(qwater55) 17: * 40620000 due date consumption (6.240000 m3)
(qwater55) 1b: 42 dif (16 Bit Integer/Binary Instantaneous value storagenr=1)
(qwater55) 1c: 6C vif (Date type G)
(qwater55) 1d: * 9F2C due date (2020-12-31)
(qwater55) 1f: 02 dif (16 Bit Integer/Binary Instantaneous value)
(qwater55) 20: BB vif (Volume flow l/h)
(qwater55) 21: 56 vife (duration of limit exceed last lower is 2)
(qwater55) 22: * 0000 error code (0)
(qwater55) 24: 32 dif (16 Bit Integer/Binary Value during error state)
(qwater55) 25: 6C vif (Date type G)
(qwater55) 26: * FFFF error date (2127-15-31)
(qwater55) 28: 04 dif (32 Bit Integer/Binary Instantaneous value)
(qwater55) 29: 6D vif (Date and time type)
(qwater55) 2a: * 180DA924 device datetime (2021-04-09 13:24)
(lse_07_17) 0f: 0C dif (8 digit BCD Instantaneous value)
(lse_07_17) 10: 13 vif (Volume l)
(lse_07_17) 11: * 04400100 total consumption (14.004000 m3)
(lse_07_17) 15: 4C dif (8 digit BCD Instantaneous value storagenr=1)
(lse_07_17) 16: 13 vif (Volume l)
(lse_07_17) 17: * 40620000 due date consumption (6.240000 m3)
(lse_07_17) 1b: 42 dif (16 Bit Integer/Binary Instantaneous value storagenr=1)
(lse_07_17) 1c: 6C vif (Date type G)
(lse_07_17) 1d: * 9F2C due date (2020-12-31)
(lse_07_17) 1f: 02 dif (16 Bit Integer/Binary Instantaneous value)
(lse_07_17) 20: BB vif (Volume flow l/h)
(lse_07_17) 21: 56 vife (duration of limit exceed last lower is 2)
(lse_07_17) 22: * 0000 error code (0)
(lse_07_17) 24: 32 dif (16 Bit Integer/Binary Value during error state)
(lse_07_17) 25: 6C vif (Date type G)
(lse_07_17) 26: * FFFF error date (2127-15-31)
(lse_07_17) 28: 04 dif (32 Bit Integer/Binary Instantaneous value)
(lse_07_17) 29: 6D vif (Date and time type)
(lse_07_17) 2a: * 180DA924 device datetime (2021-04-09 13:24)
*/
int offset;
@ -172,40 +172,40 @@ void MeterQWater55::processContent(Telegram *t)
}
double MeterQWater55::totalWaterConsumption(Unit u)
double MeterLSE_07_17::totalWaterConsumption(Unit u)
{
assertQuantity(u, Quantity::Volume);
return convert(total_water_consumption_m3_, Unit::M3, u);
}
bool MeterQWater55::hasTotalWaterConsumption()
bool MeterLSE_07_17::hasTotalWaterConsumption()
{
return true;
}
double MeterQWater55::dueDateWaterConsumption(Unit u)
double MeterLSE_07_17::dueDateWaterConsumption(Unit u)
{
assertQuantity(u, Quantity::Volume);
return convert(due_date_water_consumption_m3_, Unit::M3, u);
}
string MeterQWater55::dueDate()
string MeterLSE_07_17::dueDate()
{
return due_date_;
}
string MeterQWater55::errorCode()
string MeterLSE_07_17::errorCode()
{
string status = to_string(error_code_);
return status;
}
string MeterQWater55::errorDate()
string MeterLSE_07_17::errorDate()
{
return error_date_;
}
string MeterQWater55::deviceDateTime()
string MeterLSE_07_17::deviceDateTime()
{
return device_date_time_;
}

Wyświetl plik

@ -61,6 +61,7 @@
X(lansenth, T1_bit, TempHygroMeter, LANSENTH, LansenTH) \
X(lansendw, T1_bit, DoorWindowDetector, LANSENDW, LansenDW) \
X(lansenpu, T1_bit, PulseCounter, LANSENPU, LansenPU) \
X(lse_07_17, S1_bit, WaterMeter, LSE_07_17, LSE_07_17) \
X(mkradio3, T1_bit, WaterMeter, MKRADIO3, MKRadio3) \
X(mkradio4, T1_bit, WaterMeter, MKRADIO4, MKRadio4) \
X(multical21, C1_bit|T1_bit, WaterMeter, MULTICAL21, Multical21) \
@ -75,7 +76,6 @@
X(tsd2, T1_bit, SmokeDetector, TSD2, TSD2) \
X(q400, T1_bit, WaterMeter, Q400, Q400) \
X(qcaloric, C1_bit, HeatCostAllocationMeter, QCALORIC, QCaloric) \
X(qwater55, S1_bit, WaterMeter, QWATER55, QWater55) \
X(sensostar, C1_bit|T1_bit, HeatMeter,SENSOSTAR, Sensostar) \
X(sharky, T1_bit, HeatMeter, SHARKY, Sharky) \
X(sontex868, T1_bit, HeatCostAllocationMeter, SONTEX868, Sontex868) \