To add a meter type, make a copy of meter_multical21.cc to
|
||
|
meter_yourmeter.cc and add your meter to meters.h (eg
|
||
|
X(YOURMETER_METER) then adjust main.cc and meters.cc to know about
|
||
|
this new meter.
|
||
|
|
||
|
In meter_yourmeter.cc, search and replace multical21 for yourmeter,
|
||
|
possibly adding a new meter type in meters.h if your meter is not a
|
||
|
water meter and inheriting from that new meter type instead.
|
||
|
|
||
|
Then assuming that the payload is encrypted using the standard AES
|
||
|
encryption, and the decrypted content follows the standard DifVif
|
||
|
format, then you only have to change processContent in
|
||
|
meter_yourmeter.cc. For Multical21 when the frame type is 0x78, it
|
||
|
means that the content contains both headers and data. Thus after
|
||
|
parseDV is called, you can access the extracted data from the map.
|
||
|
|
||
|
For example: extractDVdouble(&values, "0413", &offset, &total_water_consumption_);
|
||
|
will retrieve the DifVif data 0x04 0x13 which means: 32bit/integer
|
||
|
storing Volume in litres. (If there are multiple 0413 data fieds in
|
||
|
the content, the second found will be stored under the key 0413_2,
|
||
|
0413_3 etc. )
|
||
|
|
||
|
When the frame is 0x79 it means a compact frame in the C1 protocol
|
||
|
that leaves out the DifVif headers! You have to know the format to
|
||
|
decode. Since I have yet to get the crc calculations to work, this
|
||
|
means that the format for multical21 is currently hardcoded, as can be
|
||
|
seen in the source line: hex2bin("02FF2004134413", &format_bytes); and
|
||
|
the comments above it. (You can see 0413 in this string.)
|
||
|
|
||
|
(The proper solution is to understand the crc and create a small
|
||
|
database of crcs to headers encoded into wmbusmeters. Thus we can
|
||
|
decode the compact frames immediately. Or if the crc is unknown we
|
||
|
have to wait until the long frame arrives to gather the crc->header
|
||
|
data and use that info for future compact frames.)
|
||
|
|
||
|
There are also vendor allowed extension points, like 02FF20 above,
|
||
|
that stores vendor specific bits of data, that happen to describe the
|
||
|
status bits of the meter, DRY, BURST, etc. Fortunately, it is possible
|
||
|
to parse and extract the data, even though you might not yet know what
|
||
|
it is.
|
||
|
|
||
|
Then unfortunately, in Multical21 it seems like they also truncate the
|
||
|
format in a non-standard way. The value 4413, is a vendor specific
|
||
|
code point, that is 32 bits in the full frame, but 16 bits in the
|
||
|
compact frame, even though the DifVif header is the same. I suppose
|
||
|
that is typical vendor specific quirk that has to be found out simply
|
||
|
by trial and error. The quirk is handled in the source code
|
||
|
by passing a lambda to parseDV that will override the length calculation
|
||
|
for a specific dif/vif combo.
|
||
|
|
||
|
But if you are lucky, a new meter might be entirely compliant with the
|
||
|
DifVif headers and makes no or very little use of vendor
|
||
|
extensions. (There is a difference in the frame format between C1 and
|
||
|
T1 see the omnipower stub). But as soon as you have found the difvif
|
||
|
data, it should be straight forward.
|
||
|
|
||
|
If you pass --debug to the commandline, wmbusmeters will print the
|
||
|
parse results of the data package on stdout. You can see what DifVif
|
||
|
data there is and adjust your code to fit. If your meter is using C1
|
||
|
mode, then simply try the multical21 meter and --debug. It will print
|
||
|
the parsing of the DifVif data and tell you the DifVif pairs
|
||
|
(DifVifVife triplets, or DifDifeVifVife quadruplets (though
|
||
|
quadruplets are not yet implemented)) even if the data comes from a
|
||
|
different type of meter.
|
||
|
|
||
|
It is very helpful if you have problems to email me (oehrstroem@gmail.com)
|
||
|
the --debug output, or just simply the telegram=|.........|.......| lines from the
|
||
|
debug output. These contain the decrypted output from the meter and
|
||
|
are very useful to replay the messages. The +... at the end can be
|
||
|
used to replay with the same timing as the messages arrived when
|
||
|
logging. This can be useful for testing the higher levels of the software
|
||
|
stack where the data is actually displayed to the user or alarms triggered.
|
||
|
|
||
|
Check in simulation.txt and test.sh for how to use this feature.
|