2c239fe63c | ||
---|---|---|
scripts | ||
simulations | ||
src | ||
tests | ||
.gitignore | ||
.travis.yml | ||
CHANGES | ||
HowToAddaNewMeter.txt | ||
LICENSE | ||
Makefile | ||
README.md | ||
XMLExtract.java | ||
check.sh | ||
configure | ||
install.sh | ||
test.sh | ||
uninstall.sh | ||
wmbusmeters.1 |
README.md
wmbusmeters
The program receives and decodes C1 or T1 telegrams (using the wireless mbus protocol) to acquire utility meter readings. The readings can then be published using MQTT, curled to a REST api, inserted into a database or stored in a log file.
The program runs on GNU/Linux, MacOSX and Raspberry Pi.
OS | Status |
---|---|
GNU/Linux & MacOSX |
Static Scan | Status |
---|---|
Linux G++ |
Run as a daemon
Remove the wmbus dongle (im871a or amb8465) from your computer.
make; sudo make install
will install wmbusmeters as a daemon that starts
automatically when an appropriate wmbus usb dongle is inserted in the computer.
Check the config file /etc/wmbusmeters.conf:
loglevel=normal
device=auto
logtelegrams=false
meterfiles=/var/log/wmbusmeters/meter_readings
logfile=/var/log/wmbusmeters/wmbusmeters.log
shell=/usr/bin/mosquitto_pub -h localhost -t wmbusmeters -m "$METER_JSON"
Then add a meter file in /etc/wmbusmeters.d/MyTapWater
name=MyTapWater
type=multical21
id=12345678
key=00112233445566778899AABBCCDDEEFF
Now plugin your wmbus dongle. Wmbusmeters should start automatically,
check with tail -f /var/log/syslog
and tail -f /var/log/wmbusmeters/wmbusmeters.log
The latest reading of the meter can also be found here: /var/log/wmbusmeters/meter_readings/MyTapWater
You can use several ids using id=1111111,2222222,3333333
or you can listen to all
meters of a certain type id=*
.
Run using config files
If you cannot install as a daemon, then you can also start wmbusmeters in your terminal using the config files in /etc/wmbusmeters.
wmbusmeters --useconfig=/
Or you can start wmbusmeters with your own config files:
wmbusmeters --useconfig=/home/me/.config/wmbusmeters
The files/dir should then be located here:
/home/me/.config/wmbusmeters/etc/wmbusmeters.conf
and
/home/me/.config/wmbusmeters/etc/wmbusmeters.d
Running without config files, good for experimentation and test.
wmbusmeters version: 0.9.2
Usage: wmbusmeters {options} <device> ( [meter_name] [meter_type] [meter_id] [meter_key] )*
As <options> you can use:
--c1 or --t1 listen to C1 or T1 messages when no meters are supplied
--debug for a lot of information
--exitafter=<time> exit program after time, eg 20h, 10m 5s
--format=<hr/json/fields> for human readable, json or semicolon separated fields
--logfile=<file> use this file instead of stdout
--logtelegrams log the contents of the telegrams for easy replay
--meterfiles=<dir> store meter readings in dir
--meterfilesaction=(overwrite|append) overwrite or append to the meter readings file
--n1a to --n1f listen to N1 messages (perhaps)
--oneshot wait for an update from each meter, then quit
--separator=<c> change field separator to c
--shell=<cmdline> invokes cmdline with env variables containing the latest reading
--shellenvs list the env variables available for the meter
--useconfig=<dir> load config files from dir/etc
--verbose for more information
As a <device> you can use:
"/dev/ttyUSB" to which a im871a/amb8465 dongle is attached,
or you can specify auto and wmbusmeters will look for a suitable dongle
on the device links /dev/im871a and /dev/amb8465.
"rtlwmbus:868.95M" to have wmbusmeters spawn:
"rtl_sdr -f 868.95M -s 1600000 - 2>/dev/null | rtl_wmbus"
(you might have to tweak 868.95M to nearby frequencies depending
on the rtl-sdr dongle you are using)
"rtlwmbus:<commandline>" to have wmbusmeters spawn
that commandline instead, the output is expected to be like rtl_wmbus.
As meter quadruples you specify:
<meter_name> a mnemonic for this particular meter
<meter_type> one of the supported meters
<meter_id> an 8 digit mbus id, usually printed on the meter
<meter_key> an encryption key unique for the meter
if the meter uses no encryption, then supply ""
Supported water meters:
Kamstrup Multical 21 (multical21)
Kamstrup flowIQ 3100 (flowiq3100)
Sontex Supercom 587 (supercom587)
Sensus iPERL (iperl)
Supported heat cost allocator:
Qundis Q caloric (qcaloric)
Work in progress:
Heat meter Kamstrup Multical 302 (multical302)
Electricity meter Kamstrup Omnipower (omnipower)
The wmbus dongles imst871a and amb8465 can only listen on one type of wmbus telegrams at a time. So you can listen to multiple meters as long as they all require the same radio mode C1 or T1. If you use rtl-sdr/rtl_wmbus, then you can listen to both C1 and T1 at the same time.
Usage examples
wmbusmeters /dev/ttyUSB0 MyTapWater multical21 12345678 00112233445566778899AABBCCDDEEFF
wmbusmeters will detect which kind of dongle is connected to /dev/ttyUSB0. It can be either an IMST 871a dongle or an Amber Wireless AMB8465. If you have setup the udev rules below, then you can use auto instead of /dev/ttyUSB0.
Example output:
MyTapWater 12345678 6.388 m3 6.377 m3 0.000 m3/h 8°C 23°C DRY(dry 22-31 days) 2018-03-05 12:02.50
(Here the multical21 itself, is configured to send target volume, therefore the max flow is 0.000 m3/h.)
Example format json output:
wmbusmeters --format=json auto MyTapWater multical21 12345678 00112233445566778899AABBCCDDEEFF MyHeater multical302 22222222 00112233445566778899AABBCCDDEEFF
{"media":"cold water","meter":"multical21","name":"MyTapWater","id":"12345678","total_m3":6.388,"target_m3":6.377,"max_flow_m3h":0.000,"flow_temperature":8,"external_temperature":23,"current_status":"DRY","time_dry":"22-31 days","time_reversed":"","time_leaking":"","time_bursting":"","timestamp":"2018-02-08T09:07:22Z"}
{"media":"heat","meter":"multical302","name":"MyHeater","id":"22222222","total_kwh":0.000,"total_volume_m3":0.000,"current_kw":"0.000","timestamp":"2018-02-08T09:07:22Z"}
Example format fields output:
wmbusmeters --format=fields auto GreenhouseWater multical21 33333333 ""
GreenhouseTapWater;33333333;9999.099;77.712;0.000;11;31;;2018-03-05 12:10.24
Eaxmple of using the shell command to publish to MQTT:
wmbusmeters --shell='HOME=/home/you mosquitto_pub -h localhost -t water -m "$METER_JSON"' auto GreenhouseWater multical21 33333333 ""
Eaxmple of using the shell command to inject data into postgresql database:
wmbusmeters --shell="psql waterreadings -c \"insert into readings values ('\$METER_ID',\$METER_TOTAL_M3,'\$METER_TIMESTAMP') \" " auto MyColdWater multical21 12345678 ""
You can have multiple shell commands and they will be executed in the order you gave them on the commandline. Note that to single quotes around the command is necessary to pass the env variable names into wmbusmeters.
You can use --debug
to get both verbose output and the actual data bytes sent back and forth with the wmbus usb dongle.
If the meter does not use encryption of its meter data, then enter an empty key on the command line. (you must enter "")
wmbusmeters --format=json --meterfiles auto MyTapWater multical21 12345678 ""
If you have a Multical21 meter and you have received a KEM file and its password, from your water municipality, then you can use the XMLExtract.java utility to get the meter key from the KEM file. You need to unzip the the KEM file first though, if it is zipped.
You can run wmbusmeters with --logtelegrams to get log output that can be placed in a simulation.txt file. You can then run wmbusmeter and instead of auto (or an usb device) provide the simulationt.xt file as argument. See test.sh for more info.
Builds and runs on GNU/Linux and MacOSX (with recent XCode)
make && make test
Binary generated: ./build/wmbusmeters
make HOST=arm
to cross compile from GNU/Linux to Raspberry PI.
Binary generated: ./build_arm/wmbusmeters
make DEBUG=true
Binary generated: ./build_debug/wmbusmeters
make DEBUG=true HOST=arm
Binary generated: ./build_arm_debug/wmbusmeters
make HOST=arm dist
(Work in progress...)
Binary generated: ./wmbusmeters_0.8_armhf.deb
System configuration
make install
installs /usr/bin/wmbusmeters
, /usr/sbin/wmbusmetersd
, wmbusmeters.service
and 99-wmbus-usb-serial.rules
.
This means that when a im871a/amb8465 dongle is inserted, then the appropriate /dev/im871a or /dev/amb8465 link is created. Also the wmbusmeters daemon will be automatically started/stopped whenever the im871a/amb8465 dongle is inserted/removed, and the daemon starts when the computer boots, if the dongle is already inserted.
If you do not want the daemon to start automatically, simply edit
/dev/udev/rules.d/99-wmbus-usb-serial.rules and remove ,TAG+="systemd",ENV{SYSTEMD_WANTS}="wmbusmeters.service"
from each line.
You can also start/stop the daemon with sudo systemctl start wmbusmeters
Source code
The source code is modular and it should be relatively straightforward to add more receivers and meters.
Read for example the text file: HowToAddaNewMeter.txt
Good documents on the wireless mbus protocol:
https://oms-group.org/download4all/
http://www.m-bus.com/files/w4b21021.pdf
https://www.infineon.com/dgdl/TDA5340_AN_WMBus_v1.0.pdf
http://fastforward.ag/downloads/docu/FAST_EnergyCam-Protocol-wirelessMBUS.pdf
http://www.multical.hu/WiredMBus-water.pdf
http://uu.diva-portal.org/smash/get/diva2:847898/FULLTEXT02.pdf
The AES source code is copied from:
https://github.com/kokke/tiny-AES128-C
TODO: CRC checks are still missing. If the wrong AES key is supplied you probably get zero readings and sometimes warnings about wrong type of frames.
There is also a lot of wmbus protocol implementation details that probably are missing. They will be added to the program as we figure out how the meters send their data.