sane-umax_pp(5)          SANE Scanner Access Now Easy          sane-umax_pp(5)


NAME

       sane-umax_pp  - SANE backend for Umax Astra parallel port flatbed scan-
       ners


DESCRIPTION

       The sane-umax_pp library implements a SANE (Scanner  Access  Now  Easy)
       backend  that  provides  access to Umax parallel port flatbed scanners.
       The following scanners work with this backend:

              Model:
              --------------------
              Astra 1220P
              HP3200C
              Astra 1600P
              Astra 2000P

       This backend handles 75x75, 150x150, 300x300, 600x600 and 600x1200  dpi
       scan resolutions, in color and gray levels. There is a software lineart
       mode.

       These scanners share the same ASIC. Only parts  such  as  CCD  and  ADC
       change  from  one  to  another.  They even all reports being UMAX Astra
       1220P via IEEE1284.  There isn't software way to recognize  them  prop-
       erly.  Under  windows, model is set by the driver installed, regardless
       of the hardware.

       EPP MODE ONLY
              The current version of the backend use only EPP mode to communi-
              cate  with the scanner. PS/2 and SPP mode aren't implemented. It
              is recommended that you set your parallel port to  EPP  in  BIOS
              with the current version of this backend.  ECPEPP will only work
              if you use a 2.4 kernel with ppdev character device support.

       This backend does support parport sharing only if  you  have  a  kernel
       with ppdev support.

       Note  that  if  you  don't  use the ppdev character device, the backend
       needs to run as root. To allow user access to the scanner run the back-
       end  through  the  network interface (See saned(1) and sane-net(5)).  A
       more relaxed solution (security wise) is to add suid bit to  the  fron-
       tend  (See  chmod(1)).  The backend drop root priviledges as soon as it
       can, right after gaining direct access to IO ports, which lessen  risks
       when being root.


DEVICE NAMES

       This backend expects device names of the form:

              port value

       Where  value  is the base address, or the ppdev device name of the port
       your scanner is attached to.  Known ports are 0x378, 0x278 and 0x3BC  .
       Or  the name of the parallel port character device user interface, such
       as /dev/parport0 for the linux ppdev, or /dev/ppi0 for FreeBSD ppi.
       Under linux, if you are not sure which port your scanner  is  connected
       to,  may  have a look at your /etc/modules.conf. Also typing dmesg|grep
       parport in a command shell should show you a line like:
       parport0: PC-style at 0x378 (0x778), irq 7, dma 3  [PCSPP,TRISTATE,COM-
       PAT,ECP,DMA]
       telling you about port address and mode.

       If  you  are  using  the linux ppdev character device, you will have to
       specify the device name, which is /dev/parport0 for the first  parallel
       port. Check the permissions on /dev/paraport0, many linux distributions
       restrict them for root only access. Get sure they are like:
       crw-rw-rw- 1 root root 99, 0 mai 20 2002 /dev/parport0
       crw-rw-rw- 1 root root 99, 1 mai 20 2002 /dev/parport1
       crw-rw-rw- 1 root root 99, 2 mai 20 2002 /dev/parport2
       crw-rw-rw- 1 root root 99, 3 mai 20 2002 /dev/parport3
       The same apply with the /dev/ppi0 character device under FreeBSD.

       You can rename any device using the

              name devname
              model model
              vendor vendor

       options. These options apply to the last port option.


CONFIGURATION

       Please make sure to edit umax_pp.conf before you use the backend.

       The contents of the umax_pp.conf file is a list of options  and  device
       names that correspond to Umax scanners.  Empty lines and lines starting
       with a hash mark (#) are ignored.

       The height  options  supported  are  red-brightness,  green-brightness,
       blue-brightness,  red-contrast,  green-contrast,  blue-contrast, astra,
       and buffer.

       Options red-brightness , green-brightness and blue-brightness allow you
       to  adjust  the  sensitivy  of your scanner for the given color. Values
       range from 0 (lowest brightness)  to  15  (highest).  If  the  advanced
       option  "Brightness"  isn't  checked  in the frontend, the backend does
       automatic brightness calibration, and do not use user provided  values.

       Options  red-contrast  ,  green-contrast and blue-contrast allow you to
       adjust the contrast of your scanner for the given color.  Values  range
       from 0 (lowest contrast) to 15 (highest).

       Option  astra  allows  you to change the model of your scanner. Current
       auto detection is based on side effects on scanning  when  using  1220P
       command set on other models, so it may fail on unkown hardware combina-
       tion. Valid values are 1220, 1600 and 2000. It  is  usefull  only  when
       autodetection  fails  to  detect  properly  your scanner model. If your
       scanner work properly but is reported wrongly, let it be that way.  The
       only  valid  case  to  change  the  model is when your scanner produces
       'black' or
        'inverted' scans.  In this case you can put the model. Be  aware  that
       it will prevent autodetection.

       Option  buffer  allows  you  to change the size of the scan buffer. The
       size must be specified in bytes. The  default  value  is  2  megabytes.
       Decreasing this value will improve the progress status reporting in the
       frontend, but will stall the scan more often.


FILES

       /usr/local/etc/sane.d/umax_pp.conf
              The  backend  configuration  file  (see  also   description   of
              SANE_CONFIG_DIR below).

       /usr/local/lib/sane/libsane-umax_pp.a
              The static library implementing this backend.

       /usr/local/lib/sane/libsane-umax_pp.so
              The shared library implementing this backend (present on systems
              that support dynamic loading).


ENVIRONMENT

       SANE_CONFIG_DIR
              This environment variable specifies the list of directories that
              may contain the configuration file.  Under UNIX, the directories
              are separated by a colon (`:'), under OS/2, they  are  separated
              by a semi-colon (`;').  If this variable is not set, the config-
              uration file is searched in two default directories: first,  the
              current     working     directory     (".")    and    then    in
              /usr/local/etc/sane.d.  If the value of the environment variable
              ends  with  the  directory separator character, then the default
              directories are searched after the explicitly specified directo-
              ries.   For  example,  setting SANE_CONFIG_DIR to "/tmp/config:"
              would   result   in   directories   "tmp/config",    ".",    and
              "/usr/local/etc/sane.d" being searched (in this order).

       SANE_DEBUG_UMAX_PP
              If  the  library  was  compiled with debug support enabled, this
              environment variable controls the debug level for this  backend.
              E.g.,  a  value  of 128 requests all debug output to be printed.
              Smaller levels reduce verbosity.

              level   debug output
              ------- ------------------------------
               0       nothing
               1       errors
               2       warnings & minor errors
               3       additional information
               4       debug information
               5       code flow (not supported yet)
               6       special debug information

       SANE_DEBUG_UMAX_PP_LOW
              This variable sets the debug level for the  SANE  interface  for
              the  Umax  ASIC. Note that enabling this will spam your terminal
              with some million lines of debug output.

              level   debug output
              ------- -------------------------------
               0       nothing
               1       errors
               8       command blocks
               16      detailed code flow
               32      dump datafiles
               255     everything


SEE ALSO

       sane(7), sane-net(5), saned(1)


       For latest bug fixes and information see
              http://umax1220p.sourceforge.net/


AUTHOR

       St?phane VOLTZ <svoltz@wanadoo.fr>, man page derived from mustek_pp man
       page by Jochen Eisinger <jochen.eisinger@gmx.net>


BUG REPORTS

       If  something doesn't work, please contact me. But I need some informa-
       tion about your scanner to be able to help you...

       SANE version
              run "scanimage -V" to determine this

       the backend version and your scanner hardware
              run "SANE_DEBUG_UMAX=255 scanimage -L 2>log"  as  root.  If  you
              don't  get any output from the umax_pp backend, make sure a line
              "umax_pp" is included into your  /usr/local/etc/sane.d/dll.conf.
              If  your  scanner  isn't  detected, make sure you've defined the
              right port address, or the correct device in your  umax_pp.conf.

       the name of your scanner/vendor
              also a worthy information. Please also include the optical reso-
              lution and lamp type of your scanner, both can be found  in  the
              manual of your scanner.

       any further comments
              if you have comments about the documentation (what could be done
              better), or you think I should know  something,  please  include
              it.

sane-backends 1.0.12-cvs       16 September 2003               sane-umax_pp(5)

Man(1) output converted with man2html