sane-sceptre.5
sane-sceptre(5) SANE Scanner Access Now Easy sane-sceptre(5)
NAME
sane-sceptre - SANE backend for SCEPTRE scanners
DESCRIPTION
The sane-sceptre library implements a SANE (Scanner Access Now Easy)
backend that provides access to Sceptre flatbed scanners. This backend
should be considered beta-quality software! Please report any strange
behavior to the maintainer of the backend or to the SANE mailing list.
At present, only one scanner is known to work with this backend:
Model Connection Type
--------------------------- -------------------
Sceptre VividScan S1200 SCSI
The make of this scanner is KINPO, so other scanners from that manufac-
turer may also work (eg. the S600).
OPTIONS
The options the backend supports can either be selected through command
line options to programs like scanimage or through GUI elements in
xscanimage or xsane.
Valid command line options and their syntax can be listed by using
scanimage --help -d sceptre
Scan Mode
--mode selects the basic mode of operation of the scanner valid choices
are Lineart, Halftone, Gray and Color. The Lineart and Halftone
mode are black and white only (1 bit). Gray will produce 256
levels of gray (8 bits). Color will produce a 24 bits color
image. The scanner supports 30 bits internally but it only
exports 24.
--resolution
selects the resolution for a scan. The scanner can do several
resolutions between 50 and 1200.
--halftone-pattern
selects the pattern mode that is used in Halftone mode. Valid
options are 1, 2, 3 and 4.
--gamma-correction
controls the scanner internal gamma correction. Valid options
are "Default", "User defined", "High density printing" "Low den-
sity printing" and "High contrast printing".
--custom-gamma
(color mode only) allows the user to specify a gamma table (see
the next 3 parameters).
--red-gamma-table
(color mode only) can be used to download a user defined gamma
table for the red channel. The table must be 256 bytes long.
--green-gamma-table
(color mode only) can be used to download a user defined gamma
table for the green channel. The table must be 256 bytes long.
--blue-gamma-table
(color mode only) can be used to download a user defined gamma
table for the blue channel. The table must be 256 bytes long.
--threshold
sets the threshold for black and white pixels in lineart mode.
Possible values are from 0 (darker) to 255 (lighter).
--preview
requests a preview scan. The resolution used for that scan is 30
dpi and the scan area is the maximum allowed. The scan mode is
user selected. The default is "no".
The geometry options
-l -t -x -y
control the scan area: -l sets the top left x coordinate, -t the
top left y coordinate, -x selects the width and -y the height of
the scan area. All parameters are specified in millimeters by
default.
CONFIGURATION FILE
The configuration file /usr/local/etc/sane.d/sceptre.conf supports only
one information: the device name to use (eg /dev/scanner).
FILES
/usr/local/lib/sane/libsane-sceptre.a
The static library implementing this backend.
/usr/local/lib/sane/libsane-sceptre.so
The shared library implementing this backend (present on systems
that support dynamic loading).
ENVIRONMENT
SANE_DEBUG_SCEPTRE
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend.
E.g., a value of 128 requests all debug output to be printed.
Smaller levels reduce verbosity.
LIMITATIONS
Resolutions
The windows TWAIN driver can be set to any resolution between 50
to 1200 (excluding software interpolation). This backend cannot.
Only a handful of resolution are available, although they should
be numerous enough.
BUGS
None known.
SEE ALSO
sane-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane(7)
AUTHOR
The package is actively maintained by Frank Zago.
http://www.zago.net/sane/#sceptre
sane-backends 1.0.18 April 21st, 2002 sane-sceptre(5)
Man(1) output converted with
man2html