- split coarse and fine cal to run independently
- add side option
- reset scan params to user request if calibration fails
- better handling of sane_cancel
- better handling of errors during sane_start and sane_read
The backend description comes from the epkowa.desc file
with appropriate changes to suit epson2.desc. The usb
device list is now generated from this file, skipping
the :unsupported models. This means epson2 now detects
32 more models.
Sometimes a "fatal error" is given back when the scanner is warming up.
The previousversion of the code checked for that issue only when
the ADF was in use.
Some subroutines have been moved from epson2.c to epson2-ops.c and
there's also a temporary fix for the networking code.
This is work in progress but should work.
- add side option to show which duplex image is being transferred
- convert front and simplex buffers to use much less ram
- add lowmemory option which makes duplex back buffer small too
- refactor image handling code to track eof's instead of lengths
- do color deinterlacing after reading from scanner, before buffering
ChangeLog to commit 1e381db161
For adding debug verbosity to sanei_usb.c patch, fixing the choice
of usb endpoints in the sanei_usb_open() seek for endpoints loop.
This commit adds some debug verbosity to the last committed sanei_usb.c patch
id 5b69fa8c6d
for fixing the choice of usb endpoints, in the sanei_usb_open() seek for endpoints loop.
- use average instead of min/max for fine offset and gain
- rewrite supported resolution list as x and y arrays
- merge x and y resolution options into single option
- move scan params into two new structs, s->u and s->s
- sane_get_parameters() just returns values from s->u
- dont call wait_scanner() in object_position()
- dont call ssm_*() from option handler
- refactor sane_start()
- read_from_buffer() can workaround missing res, modes and cropping
- set most DR-2xxx machines to use the read_from_buffer workarounds
- set default threshold to 90
- add option for button #3 of some machines
- don't eject paper during init
- add DR-2010 quirks
- switch counter to HARD_SELECT, not SOFT
Updated following files for Pixma MP730 support:
- backend/pixma_mp730.c:
Add width scan area fitting
Fix end scan sequence protocol
- sanei/sanei_usb.c:
In sanei_usb_open(), changed the "seek for endpoints" loop
so that it first looks for those interfaces (in config 0)
that have been detected as potential scanners in
sanei_usb_init()
- bug fix in read_panel()
- initialize vars in do_usb_cmd()
- set buffermode off by default
- clear page counter during init and sane_start()
- eject previous page during init and sane_start()
- improved SSM_BUFF macros
- moved set_window() to after ssm-*()
- add coarse calibration (AFE offset/gain & per-channel exposure)
- add fine calibration (per-cell offset/gain)
- free image and fine cal buffers in sane_close()
- compare page counter of small scanners only in non-buffered mode
- add back-side gray mirroring code for DR-2580C