Stéphane Voltz
4b17ba9ca0
umax_pp.c: cleanings and minor fix in option file reading
...
umax_pp_low.c umax_pp_low.h: *BSD support for /dev/ppi0
2003-04-18 12:53:55 +00:00
Henning Geinitz
517751ff09
Added hp5400 backend from Martijn van Oosterhout <kleptog@svana.org> and
...
Thomas Soumarmon <soumarmt@nerim.net>. Changed to use sanei_usb instead of
direct /dev/usb/scanner access. Added manual page. Fixed some portablility
issues and some warnings. Added SANE headers.
2003-04-17 09:19:25 +00:00
Henning Geinitz
87387511b0
Added IBM backend for the IBM 2456, the Ricoh IS-420 and maybe the IS-410 and
...
IS-430 from mf <massifr@tiscalinet.it>. Added manual page, fixed some
warnings, Added detection for IS-410 and IS-430.
2003-04-15 09:54:00 +00:00
Peter Kirchgessner
3b43770843
Second try to fix problem with null-pointer in sane_control_option
2003-04-14 19:29:37 +00:00
Peter Kirchgessner
b35cbffda9
check pointer received from sane_control_option()
2003-04-14 18:20:41 +00:00
Henning Geinitz
dfe765e251
Fixed some compilation warnings.
2003-04-13 13:25:15 +00:00
Henning Geinitz
d60a4441d1
Fixed warning for dll-preload.c.
2003-04-13 13:21:11 +00:00
Henning Geinitz
98894a03c6
Remove test for multi-pass.
2003-04-11 09:39:31 +00:00
Henning Geinitz
eda0c4bc5e
Updated Mustek BearPaw 1200 CU Plus white strip value. Set Mustek ScanExpress
...
A3 USB to CCD. Black mark may be still wrong. Minor formatting changes in the
manpage. Decreased ScanExpress A3 USB status to alpha because of CIS/CCD
change.
2003-04-11 09:37:24 +00:00
Henning Geinitz
04dd7d101f
Added support for OS/2 (from Franz Bakan <fbakan@gmx.net>).
2003-04-10 08:36:10 +00:00
Nathaniel Rutman
2b0ea7786e
Removed last change in offset/gain calculation, which croaked for some
...
cases. Give up early if we can't talk on the USB.
Added option to force scanner recalibration.
2003-04-05 19:44:04 +00:00
Henning Geinitz
4d4f8a4c64
Added some missing debug messages. Fixed a warning.
2003-04-04 10:26:20 +00:00
Henning Geinitz
2efe9ab441
Fixed some warnings.
2003-04-03 16:39:56 +00:00
Henning Geinitz
8fb02e0e36
Fixed a bunch of compilation warnings.
2003-04-03 16:20:47 +00:00
Henning Geinitz
967a3b2a37
Fixed some warnings.
2003-04-02 22:41:54 +00:00
Eddy De Greef
5eba8d93a2
One fatal and various minor bug fixes in mustek_pp.c.
2003-04-02 21:58:44 +00:00
Oliver Schwartz
4236b5982c
Enabled 1200 DPI for Acer 5000
2003-04-02 21:22:53 +00:00
Oliver Schwartz
e30553a7c5
SnapScan backend 1.4.25
2003-04-02 21:01:07 +00:00
Henning Geinitz
284ff7a543
Initialize global variables in sane_init.
2003-04-02 15:02:42 +00:00
Henning Geinitz
a2e76b2942
Remove Chris Pinkham as active maintainer because his primary email address
...
bounces, the website is dead and he doesn't respond to mails to other
addresses. Marked email addresses and website as dead. Fixed AT3 misdectection
that was on the TODO list for some time.
2003-04-02 14:40:48 +00:00
Henning Geinitz
27beb7d01b
Fixed comment headers. They were copied verbatim from the dll backend.
2003-04-02 14:04:06 +00:00
Henning Geinitz
088281c4e1
Added support for IPv6. Updated manpages. Patch from Julien BLACHE
...
<jb@jblache.org>.
2003-03-30 19:07:18 +00:00
Oliver Schirrmeister
bfdf791597
added fujitsu fi-4120C support
2003-03-28 14:46:17 +00:00
Karl Heinz Kremer
5652917dd6
Added workaround for GT-8000 scanner, fixed two warnings reported by der Mouse.
2003-03-26 23:18:58 +00:00
Rene Rebe
8ce6e0d515
Updated the avision backend to latest build. This includes user-space
...
USB support and OS/2 thread handling.
2003-03-25 01:43:35 +00:00
Ulrich Deiters
c6d5ebe9fb
Modified behaviour of the option "eject after each scan":
...
Eject is suppresed for film scanners after preview scans.
2003-03-22 16:31:52 +00:00
Henning Geinitz
341f58125e
Fixed segmentation fault when $PATH is not set.
2003-03-17 19:33:00 +00:00
Oliver Schirrmeister
86a3214291
patch from Ron Cemer <ron@roncemer.com>
...
fixes the broken "ADF empty" detection on the Fujitsu scanners
when connected via USB. It also fixes a sense-request issues,
which were required in order to determine whether the ADF is
empty. It also eliminates some duplicate code blocks.
renamed some functions
2003-03-14 18:21:22 +00:00
Henning Geinitz
a84d4a611f
Added Packard Bell Diamond 1200 Plus to .desc and manpage. New flag to avoid
...
running stop_scan before doing a scan. The Windows firmware of the BearPaw
1200 CU Plus doesn't seem to like that.
2003-03-13 17:18:29 +00:00
Oliver Schirrmeister
711bb118b4
displays the offending byte when something is wrong in the
...
window descriptor block.
2003-03-10 12:38:36 +00:00
Eddy De Greef
61c2a6aa24
Fixed two calibration bugs: one occasionally caused overexposed images
...
at all resolutions; the other one occasionally caused color inbalances
when scanning narrow areas at high resolutions.
2003-03-09 20:32:49 +00:00
Henning Geinitz
8d9c13ed82
Minor debug message updates. Fixed a little bug in sane_control_option (gamma
...
control). Removed the signal blocking again. That only hides the segfault in
sanei_scsi. Check if there are documents in ADF for Paragon 2. Otherwise
return error. Fix some minor issues in reading the config file.
2003-03-07 19:31:26 +00:00
Henning Geinitz
0bb508a879
Small requests are done with a response buffer of 8 bytes (instead of 64)
...
now. Looks like GT-6816 based scanners return 8 bytes if the firmware is
loaded and 64 bytes if it's not loaded. Changed GT-6816 firmware check to
ignore errors from above change. GT-6816 scanners work with the BSDs now (at
least once). Updated manpage concerning the BSDs.
2003-03-06 14:27:54 +00:00
Henning Geinitz
6a0dd9cd5e
Added missing option size (avoids crash on network scanning). Patch from Milon
...
Firikis <milonf@hotpop.com>.
2003-03-05 18:04:33 +00:00
Oliver Schirrmeister
f9d7350534
* backend/fujitsu.c, backend/fujitsu.h: renamed some variables
...
* backend/fujitsu.c: gray duplex scanning now works with the 4097D
when disconnect is enabled in the scsi-controller
* doc/descriptions/unsupported.desc: remove fujitsu fi4120C
* doc/descriptions/fujitsu.desc added fi4120C, ScanParter 93GX
2003-03-05 12:56:44 +00:00
Gerhard Jaeger
ca786b2c28
Bug-fix update for Genius, HP2100c and EPSON Photo devices.
2003-03-03 14:34:20 +00:00
Henning Geinitz
a04ea4b251
Make sure that the firmware for plustek-like scanners is loaded. Didn't work
...
for Genius vivid3xe. Added both Genius scanners to man page. Removed warning
from Genius Vivid3xe.
2003-03-02 22:08:50 +00:00
Michael Herder
6520e41917
*** empty log message ***
2003-03-02 06:55:18 +00:00
Ulrich Deiters
bf3546ca14
adjusted backend/canon-sane.c to use the new sanei_constrain_value()
...
made some cosmetic changes to reduce the number of compiler warnings
2003-02-28 09:35:24 +00:00
Henning Geinitz
4b00890161
Added Genius Colorpage Vivid3xe. Added request_type and request fields to the
...
command set. Request is 0x01 or 0x04.
2003-02-27 17:31:52 +00:00
Ulrich Deiters
4fe497b559
* modified the Canon SCSI backend (now version 1.12):
...
* backend/canon.c, canon-sane.c, canon.h: Added support for
the FB1200S flatbed scanner.
* backend/canon.c: Made the sense handler generate meaningful
status information for new scanner models (solved the Mandrake
crash problem).
* backend/canon.c, canon-sane.c, canon.h: Moved model-dependent
declarations and decisions to a common location.
* backend/canon-sane.c: Fixed the out-of-memory problem of
xscanimage when doing previews with scanners using hardware
scan resolutions only.
2003-02-26 13:50:00 +00:00
Stéphane Voltz
5ed8c99cb7
- changed 'gain' option name to 'brightness'
...
- changed 'highlight' option name to 'contrast'
2003-02-25 07:04:12 +00:00
Henning Geinitz
747619ae5f
Added new backend ma1509 for Mustek BearPaw 1200F scanners.
2003-02-24 21:04:08 +00:00
Simon Munton
d152930b5e
incremented BUILD in pie.c (missed in last change)
2003-02-23 17:12:51 +00:00
Simon Munton
0423675807
fixed segmentation faults in pie.c when sane_init/sane_exit called more than once
2003-02-23 13:32:52 +00:00
Stéphane Voltz
711f602c76
- reset global vars when needed
...
- fixed a bug when th device name used was ""
2003-02-23 08:54:16 +00:00
Henning Geinitz
3cf8377bee
Initialize global variables in sane_init.
2003-02-22 16:54:22 +00:00
Henning Geinitz
7e4fe2df10
Iniatialize global variables explicitely. Mention ma1509.
2003-02-22 16:48:02 +00:00
Henning Geinitz
8dedb6c862
Explicitely initialize global variables to avoid segfaults when calling
...
sane_init/sane_exit more than once.
2003-02-22 16:22:25 +00:00
Henning Geinitz
b0d7681738
Initialize global variables in sane_init to avoid segmentation faults when
...
sane_init/sane_exit is run more than once.
2003-02-22 15:37:19 +00:00
Henning Geinitz
a0251b6cc1
Added vid/pid 0x07b3/0x0400 to gt68xx.conf also. Added indormation about
...
Medion 4394. Mention ma1509 backend. Fix segfault when calling sane_open with
an empty device name.
2003-02-22 15:34:51 +00:00
Oliver Schirrmeister
b7fbc8a3aa
bugfixes: option RIF is available for the 3091 and 3092,
...
set availability of options THRESHOLD und VARIANCE
2003-02-20 14:48:55 +00:00
Oliver Schirrmeister
d74d4231ce
patch from <ron@roncemer.com>
...
fi4220 support
usb support
2003-02-20 13:33:07 +00:00
Stéphane Voltz
a7b7dfb309
- EPP mode set fix for direct hardware access
...
- icc compile fixes
2003-02-18 13:32:52 +00:00
Henning Geinitz
b9a6e5cc4a
Make sure that the result of the reader_process is interpreted
...
correctly. Block signals when waiting for a SCSI request to finish. Otherwise
we may get a segfault if the reader_process is terminated while waiting.
2003-02-17 12:05:56 +00:00
Henning Geinitz
57e852ea8a
List BearPaw 2400 CS Plus as supported. Make fast preview the default
...
(otherwise BP 2400 TA Plus wouldn't work with 12/16 bits). Added vid/pid
0x07b3/0x0400, that's another Plustek OpticPro 1248U.
2003-02-16 21:31:45 +00:00
Rene Rebe
2f8f90a79a
Update to the latest Avision backend release. It includes feature
...
and stability improvements and bug fixes. The sane man-page now
mentions that the avision backend supports more than the AV 630 CS ...
2003-02-16 17:35:05 +00:00
Karl Heinz Kremer
e1b2d70a16
Moved sanei_usb_init() to sane_init(). Thanks to Ron Cemer for the patch.
2003-02-15 21:09:47 +00:00
Karl Heinz Kremer
aae28825db
Fix problem with "usb <vendor> <product> syntax in config file
2003-02-15 18:18:58 +00:00
Peter Fales
fefaf27951
1) Don't coredump if gphoto2.conf file is missing. 2) Don't require
...
a speed to be set in gphoto2.conf if the serial port is not used.
2003-02-12 02:54:47 +00:00
Peter Fales
333db710cd
Added a (commented out) entry for gphoto2 in dll.conf
2003-02-12 02:16:42 +00:00
Peter Kirchgessner
71103c85e6
Fix a problem with ifdef/ifndef for threads
2003-02-11 22:34:11 +00:00
Stéphane Voltz
b2370c178e
- fixed a big bug related to color plane sync, which gave blur
...
pictures at > 75 dpi
- changed version number
2003-02-09 08:26:00 +00:00
Peter Fales
54d9e2729d
Fixes for Irix from Andrea Suatoni
2003-02-09 03:23:59 +00:00
Henning Geinitz
5b79536901
Fixed resolutions for BearPaw 1200 TA. Increase the lowest black for CCD
...
coarse calibration. Adjusted internal gamma correction. CCD scanners use
color mode for coarse+quality cal now. Preview isn't always in 8 bit mode now
(can be selected by option). Upper and lower limits for coarse calibration are
unified now. Added options for adjusting gain and offset.
2003-02-05 16:02:45 +00:00
Peter Kirchgessner
216c5cec42
Add OS/2-support for hp-backend
2003-02-02 17:03:36 +00:00
Gerhard Jaeger
7d13614480
*** empty log message ***
2003-01-31 12:36:44 +00:00
Jochen Eisinger
641376bc7f
2003-01-25 Jochen Eisinger <jochen.eisinger@gmx.de>
...
* backend/mustek_pp.c: fixed some character encoding issues in
debug messages
2003-01-26 13:45:33 +00:00
Jochen Eisinger
3c30357f9d
2003-01-24 Jochen Eisinger <jochen.eisinger@gmx.de>
...
* backend/mustek_pp_ccd300.c: continued on the CCD low-level driver.
There is still some bug in it, that keeps it from actually scanning
something...
2003-01-25 20:04:52 +00:00
Henning Geinitz
85dddb6ca0
Use "Color pattern" consistantly.
2003-01-24 14:00:11 +00:00
Henning Geinitz
f25fd9c455
Minor conversion fixes (from Andrea Suatoni <a.suatoni@telefonica.net>).
2003-01-24 13:52:52 +00:00
Gerhard Jaeger
ee94f0caf1
Minor fixes and prototype description updates, code cleanup, doc update.
2003-01-24 11:44:04 +00:00
Andras Major
36a01d3b84
*** empty log message ***
2003-01-23 23:41:21 +00:00
Eddy De Greef
2fe806cb51
Compile warning fix and minor debug message fixes.
2003-01-21 21:45:00 +00:00
Karl Heinz Kremer
0f701cfaa2
Added information about MFDs (multi-functional devices, scanners with
...
printers) to documentation and sane_usb.c file.
2003-01-19 19:17:29 +00:00
Henning Geinitz
6d895dbc7b
Removed wrong "untested" flag from Mustek AE USB and Lexmark X70/X73 scanners.
2003-01-18 11:46:15 +00:00
Frank Zago
4c36caa5ac
*** empty log message ***
2003-01-17 01:56:01 +00:00
Henning Geinitz
af90832aee
Bugfix for the X12USL(solved problems >600dpi), one for lineart mode with a
...
6400XL and one for Scanmaker 5 (crashes at sendgamma). From Karsten Festag
<karsten.festag@gmx.de>.
2003-01-16 22:07:18 +00:00
Jochen Eisinger
48d3828a13
2003-01-13 Jochen Eisinger <jochen.eisinger@gmx.de>
...
* backend/mustek_pp*, backend/Makefile: merged all mustek_pp
related files into one compile unit and removed illegal symbols
2003-01-13 19:49:47 +00:00
Nathaniel Rutman
b1d4dce599
calibration and gamma correction enhancements by M.Reinelt <reinelt@eunet.at>
2003-01-13 03:01:04 +00:00
Jochen Eisinger
47e110e473
2003-01-12 Jochen Eisinger <jochen.eisinger@gmx.de>
...
* doc/sane-mustek_pp.man, doc/descriptions/mustek_pp.desc,
backend/mustek_pp*: replaced the old mustek_pp backend with
version 12-alpha. This version fully supports CIS scanners but
removes support for 600dpi CCD scanners and the 300dpi CCD
support isn't yet working. In contrary to the old backend, this
version is based on information provided by Mustek. For now,
the backend exports lots of illegal symbols, this will be fixed
before code freeze. Also the .desc file is empty and will be updated
soon.
* AUTHORS: added Eddy De Greef who wrote the CIS hardware driver part
2003-01-12 19:44:26 +00:00
Abel Deuring
1f7adcf0d1
backend/sharp.*: fixed a segfault, when the SCAN command returned
...
an error; optional "relaxed" handling of transparency unit errors.
Abel
2003-01-12 14:17:19 +00:00
Henning Geinitz
be735bc16b
OPT_THRESHOLD fix. Avoid using "_" in option names. Set more options in
...
microtek2.conf to on by default. From Karsten Festag <karsten.festag@gmx.de>.
2003-01-11 22:15:14 +00:00
Henning Geinitz
1652b580a4
Removed hardcoded option size.
2003-01-10 17:15:12 +00:00
Gerhard Jaeger
8ba08fdfca
Update to version 0.45, added some new models and support for libusb.
2003-01-10 13:32:11 +00:00
Ulrich Deiters
ee88748aa6
fixed uninitialized variable; made SANE pay attention to return status of
...
do_focus() and do_gamma()
2003-01-10 07:11:33 +00:00
Peter Fales
fa0abed1cf
Fix OS/2 build error
2003-01-10 01:09:12 +00:00
Henning Geinitz
9f0d82980b
Updated manpage and .desc concerning Lexmark X70. Updated manpage concerning
...
kernel 2.4.21-pre3 containing the 1-endpoint fix. Fixed A3 USB resolution
setting. Updated A3 USB margins (Pedro Morais <morais@inocam.com>). Added
detection of Genius Colorpage Vivid3x. It's unknown if it works. Updated
.desc file. Don't print calib line warnings by default.
2003-01-09 18:05:01 +00:00
Henning Geinitz
a50e314cbe
Improved support for Scanmaker X12USL. Alpha support for Scanmaker
...
9800XL. Some bugfixes. (From Karsten Festag <karsten.festag@gmx.de>).
2003-01-09 00:40:45 +00:00
Oliver Schwartz
42f2440739
Update to snapscan backend 1.4.18
2003-01-08 21:45:28 +00:00
Oliver Rauch
0b681c7438
update to sane-umax build 39
2003-01-07 18:18:46 +00:00
Peter Fales
d8410c5ad2
backend/dc210.c, backend/dc240.c - use a more portable way to generate
...
serial port "breaks"
2003-01-07 15:43:41 +00:00
Matthew Duggan
e9220432d0
2003-01-07 Matthew Duggan <stauff1@users.sourceforge.net>
...
* backend/canon_pp-dev.c: Improve/fix detection logic.
* doc/descriptions/canon_pp.desc: Bump version number.
2003-01-07 05:14:28 +00:00
Peter Fales
58993e7e36
Irix fixes from mailing list
2003-01-07 01:15:16 +00:00
Peter Fales
5e464b1576
Fix compiler warning
2003-01-07 01:10:44 +00:00
Peter Fales
f37d33ccaa
Fix logic bugs from mailing list
2003-01-05 19:54:49 +00:00
Stéphane Voltz
34ba009415
- made /dev/parport0 the default device for scanning
...
- small picture quamity improvement
2003-01-05 07:37:54 +00:00
Karl Heinz Kremer
fa68479dcb
Removed one '//' comment.
2002-12-31 21:20:33 +00:00
Henning Geinitz
f63abd633e
Make sure that frontend bugs concerning the select fd are detected.
2002-12-30 13:44:27 +00:00
Henning Geinitz
b97a0721b5
Updated ScanExpress 2400 USB values. Added implementation of gt6801 lamp
...
control for CCD scanners. Added flag for SE 2400 USB, added some quirks in
gt68xx_gt6801.c. Fixed gt68xx_gt6801 -> lamp control. Adjusted Plustek 1248U
geometry and afe values. CCD gross calibration changed: start with the default
value from module struct. Is faster now for most cases. Only 2.5 mm of
calibration for GT-6801 scanners. Added "afe" option for gt68xx.conf for
selecting default afe values. Removed AFE and exposure SANE options. Added
documentation for afe option in gt68xx.conf. New version: 1.0-35.
2002-12-30 13:05:24 +00:00