* applied a patch by Douglas Gilbert to sanei_scsi.c
it solves the Problem that the scanner is not
found on linux systems when the order of the
scsi devices is not coverd by the order of
devices listed by /proc/scsi/scsi, it prefers
new kernel 2.4 methods when available
for existing sane installations and plustek memory access violation.
Added Canon FB620S and FS2710 backend and entries about Tru64
compilation problems and installation procedure for translations.
Generate sane-backends.html in doc/. New target: install-mostang.
Installs the sane standard (.ps, .ps.gz and html), the html manpages,
and sane-backends.html on www.mostang.com.
* backend/artec.c: Fixed bug causing possible dereference of a NULL
pointer.
* backend/artec.desc: Modified USB entry to say AS6E scanner supported
by SANE AS6E backend.
* PROJECTS: Added entry for the Fujitsu M3091DCd. Updated my email
address.
* TODO: Added entry for the Fujitsu M3091DCd and a combined Fujitsu
backend. Clarified that "printf" also shouldn't be used.
* backend/dll.desc: Added my email as contact address.
* backend/m3091.desc: New file for the Fujitsu M3091DCd.
* doc/sane-mustek.man: Updated URL.
* backend/mustek.CHANGES backend/umax.CHANGES backend/umax.FAQ
backend/umax.TODO: Moved to doc/mustek respectively doc/umax.
* doc/canon.CHANGES doc/canon.install2700F.txt doc/canon:
Moved canon-specific documentation to doc/canon.
* doc/mustek: New subdirectory for mustek-specific documentation.
* doc/sane-umax*.html doc/sane-umax*.jpg doc/sane-umax-doc.tex
doc/sane-umax-doc.dvi doc/umax: Moved all the umax-specific
documentation to new subdirectory umax.
* backend/agfafogus.c: Moved PATH_MAX after sanei_backend.h include
to avoid warning. Changed printf to DBG.
* backend/mustek.c backend/mustek.CHANGES backend/mustek.desc: Added
support for translating options. Used only PACKAGE_VERSION for
output. Updated email address. New version: 1.0-107.
* include/sane/sanei_backend.h include/sane/saneopts.h: Added macro
SANE_I18N. It's used to mark strings that can be translated and
used by a frontend. Usually these are option titles and descriptions
as well as the contents of string lists. Used this macro to mark
the translatable strings in saneopts.h. More translation support
will follow.
* PROBLEMS: Point to pnm/saned security risks.
* TODO: Removed the entries about epson usb mis-detection and check
for installed sane versions.
* configure configure.in backend/Makefile.in: Added detection of older
versions of SANE. The pnm backend is now disabled by default.
* backend/dll.c backend/dll.desc: Fixed file descriptor leak (found by
Douglas Gilbert). New version: 1.0.2.
* backend/net.desc: Added Jochen Eisinger's email address as contact
for the net backend.
* doc/sane-pnm.man: Point to pnm/saned security risks.
* AUTHORS: Added Michael Herder and me for pnm. Updated my email
address.
* TODO: Removed pnm entry about adding more options. Added entry about
epson backend freezing when trying to detect non-epson USB scanner.
Added entry about adding contact adresses to .desc files. Added
comment about me working on a sane man page. Removed entry about OS/2
problems in sanei_scsi.c.
* configure configure.in: Removed a newline in --help message.
* backend/pnm.c: Added several options: gamma tables
(-> arrays), resolution option (word list), read only test option
(SANE_CAP_SOFT_DETECT), several options for returning status codes
in sane_read (all of this is from Michael Herder <crapsite@gmx.net>).
Added build version info, print version information in sane_init.
Use ../include/sane/ for includes. Version is 1.0.1.
* backend/pnm.desc: Updated contact info and version.
* backend/dc210.desc backend/dc240.desc backend/microtek2.desc:
Update contact information for backends. dc240 status is :NEW.
* TODO: added entries about as6e status shouldn't be :new, and
installing all documentation files.
* README: Updated xsane link.
* configure configure.in backend/dll.c backend/dll.desc
backend/net.c backend/net.desc include/sane/config.h.in
Yet another change in the version system for dll and net.
For sane_init return the version of the package but use
own internal version number in the source (printed with
debugging enabled) and in *.desc. The internal versions
of both net and dll are set to 1.0.1. Please increase the
build number with every change on the source files.
* doc/realeases.txt -> doc/releases.txt. Fixed spelling error.
Added entries about sane-backends.html, sane.ps, man pages,
platforms page.
* PROJECTS TODO: Added entry about E3 USB chipset.
* backend/dll.c backend/dll.desc: New version is 1.0.5. Version and
PACKAGE_VERSION is printed with debug level set to 1 or higher.
The version numbers of all backends that are loaded are printed
at debug level 3 or higher. Print error if backend with wrong
major version number is loaded. Some standardization changes
concerning the DBG messages.
* backend/net.c backend/net.desc: New version is 1.0.5. Version and
PACKAGE_VERSION is printed with debug level set to 1 or higher.
Some standardization changes concerning the DBG messages.
* backend/pnm.c: Return SANE_INFO_RELOAD_PARAMS even if the pnm
file doesn't exist or can't be loaded (from mh <crapsite@gmx.net>).
* doc/backend-writing.txt: Added AUTHORS to the list of things that
should be updated when including a new backend. Added points about
avoiding printf and exit in backends.
* doc/releases.txt: New file. This text summarizes some points to
pay attention to when a new release of sane-backends is made.
Additions and corrections are appreciated.
* doc/scanimage.man: Add some more information about the -V option.
* frontend/scanimage.c: The option -V now also prints the version of
the backend (ususally dll).
* backend/mustek.c backend/mustek.desc backend/mustek.CHANGES
Added detection of the TA for the Paragon 1200 SP Pro. Added
warning about not supported Trust scanners. Changed description
of contarst and brightness settings. Backend status is "stable"
now. New version: 1.0-106.
* acinclude.m4 aclocal.m4: Fixed comment concerning dc240.
* configure configure.in include/sane/config.h.in: Added test for
socklen_t in sys/socket.h. This fixes the compilation problem on
Irix.
* doc/sane-avision.man doc/sane-ricoh.man doc/sane-s9036.man
doc/sane-tamarack.man: find-scanner is now called
sane-find-scanner and installed on the system so it's not
necessary to point to the tools directory.
* frontend/scanimage.c: Fixed too long line in output.
* sane-config.in: Name is sane-config again (was sane-backends-config
due to the renaming of the package).
* TODO: Removed entry about net.c not compiling on Irix and
references to find-scanner in the man pages. Updated numbers of
the compilation warnings. Still too many, however.
* backend/sc240.c backend/dc240.h backend/dc240.conf
backend/dc240.desc backend/dll.conf doc/sane-dc240.man:
Added dc240 backend for the Kodak DC240 Digital camera (from
Peter Fales <peter@fales.com>).
* doc/Makefile.in: Added sane-dc240 in section 5.
* backend/Makefile.in: Added dc240.
* configure configure.in: If the jpeg libs are not available,
dc240 is also disabled.
* AUTHORS: Added entry for dc240 and updated email address of
Peter Fales.
* NEWS: First version of the news entry for 1.0.5.
* PROJECTS: Removed dc240. Added Microrec ScanMaker 3600.
* README: Added dc240.
* TODO: Removed dc240. Added entry about keep-alive mechanism in saned.
* sane-backends.lsm: Added dc240.
* testsuite/.cvsignore: New file. Added entry for Makefile.
* backend/mustek.c backend/mustek.desc backend/mustek.h
backend/mustek.CHANGES: Fixed grascale gamma for the 600 II N.
Fixed ADF problems when selecting windows smaller than the
whole scan area. Fixed linedistcnace corrections issues concerning
ADF and concerning 1200SP V 1.00. New version: 1.0-105.
* backend/bh.c backend/bh.h doc/sane-bh.man
added support for Copiscan 8000 series by Mark Temple
added options deskew and rotation
inquiry compares product to COPISCAN rather than COPISCAN II
* AUTHORS: Added Tom Martone.
* PROJECTS: Removed bh (now included in sane).
* README: Added entry for sane-bh(5).
* TODO: Removed bh. Updated BearPaw entry. Added entry about v4l
problem.
* backend/v4l.c: Changed comment as v4l is part of the sane package.
* backend/bh.c backend/bh.conf backend/bh.h doc/sane-bh.man
Added new backend Bell and Howell Copiscan scanners
* backend/bh.desc
Updated version from (0.1) to 1.0-4
Referenced manpage
* backend/Makefile.in
Added bh to PRELOADABLE_BACKENDS
Added libsane-bh.la dependencies
* doc/Makefile.in
Added sane-bh.5 to SECT5
* backend/mustek.c backend/mustek.desc backend/mustek.h
backend/mustek.CHANGES doc/sane-mustek.man:
Added 36 bit mode for Pro models. Removed support for "special"
modes, used options instead. Code cleanup. Updated manpage
concerning sane-find-scanner. New version: 1.0-104.
* configure: regenerated from configure.in.
* tools/find-scanner.c: Removed. Now called sane-find-scanner.
* tools/sane-find-scanner: New file (was find-scanner).
* tools/.cvsignore tools/Makefile.in tools/README: Updated because
of name change. sane-find-scanner is installed now.
* README README.linux: Updated because of sane-find-scanner.
* frontend/scanimage.man: Updated because of sane-find-scanner.
* doc/sane-find-scanner.man: New file.
* doc/.cvsignore doc/Makefile.in: Added sane-find-scanner(1).
* TODO: Updated concerning sane-find-scanner. Added entry about
qcam /tmp file handling. Some spelling corrections.
* backend/mustek.CHANGES backend/mustek.c backend/mustek.desc
backend/mustek.h doc/sane-mustek.man: Added calibration for Pro
scanners and the SE 12000 SP Plus. Added option to use the full
legal size of the Paragon 1200 LS scanner. Added fast preview for
Pro scanners. Bug fixes. New version: 1.0-103.
Added bit-depth selection again.
Fixed problem with bilevel scanning with Perfection610: The
line count has to be an even number with this scanner.
Several initialization fixes regarding bit depth selection.
This version goes back into the CVS repository, the 1.0.4
release is out and therefore the code freeze is over.
Some general cleanup, added more comments
* TODO: Removed entry about net/saned crashes.
* backend/net.c: Fixed segfault when using SANE_TYPE_STRING options
(e.g. scanimage on localhost). Added checks to prevent other
segfaults. Fixed some warnings.
* backend/snapscan.desc: Changed to use new homepage.
* NEWS: Added date of release.
* TODO: Removed entries about PATH_MAX, sanei_scsi_find_devices, and
shm.h. Added entry about the necessity to check HAVE_SYS_SHM_H.
* configure configure.in include/sane/config.h.in: Default to
--enable-warnings again. Don't set "-ansi" for OS/2. Test for
sys/shm.h.
* backend/GUIDE: Moved to doc/backend-writing.txt.
* doc/backend-writing.txt: New file (moved from backend/GUIDE).
Added comments about sanei-backend.h and PATH_MAX.
* include/sane/sanei_backend.h: Added define for PATH_MAX (if
necessary).
* sanei/sanei_scsi.c: Implemented sanei_scsi_find_devices for FreeBSD
(from ports@FreeBSD.org).
* tools/Makefile.in: Use INSTALL_SCRIPT instead of INSTALL_PROGRAM for
sane-config (from ports@FreeBSD.org).
2000-12-22 Henning Meier-Geinitz <hmg@gmx.de>
* configure configure.in: Changed version to 1.0.4 and package to
sane-backend (from Oliver Rauch <Oliver.Rauch@Wolfsburg.DE).
* sane.lsm Removed (renamed to sane-backends.lsm).
* sane-backends.lsm New file. Package name is sane-backends instead
of sane and added additional maintainer: Oliver Rauch (from
Oliver Rauch <Oliver.Rauch@Wolfsburg.DE).
* doc/sane-scsi.man: Small changes/updates concerning Linux
2.2. Updated entries about Adaptec cards, NCR53c400/Domex 3181
cards, NCR 810 cards. Removed direct links to some backends.
* doc/sane-snapscan.man: Added link to new snapscan website.
* backend/mustek.c backend/mustek.desc backend/mustek.CHANGES:
Fixed wrong comment in encode_resolution. Added missing test for
return status in sane_start. Fixed wrong calculation of tlx and
tly for Pro series scanners. Increased version number.
* NEWS: Updated backend versions. Added point about compilation fixes
on Irix and FreeBSD.
* backend/mustek.c backend/mustek.desc backend/mustek.CHANGES:
Fixed problem with lamp control of SE scanners and reduced
length of scan area for Paragon 1200 SP PRO. Removed warning for
this scanner. Increased version number.
* TODO: Updated. Added point about plustek-share.h using c++ comment
and reminder to check config.in.h. Removed entriy about as6e.c stat
result check.
* backend/as6e.c backend/as63.h: Comitted patch from Eugene Weiss
<eweiss@sas.upenn.edu>. Fixes: Use only DBG (no printfs). Check result
of stat. Add GPL header.
* removed usage of gettext, problem with -lintl should be solved:
- removed usage of gettext from lib/getopt.c
- removed test for libintl/gettext in configure[.in] - removed intllib from frontend/Makfile.in
Removed changes regarding 12/14 bit support because of SANE
feature freeze for 1.0.4.
The following fixes are in the software compared to the version
prior to the feature freeze:
- refresh UI after a change in the scan mode setting (was not updated
when going from Binary to Gray or vice versa)
- Read values for "line distance" from the scanner instead of using
hardcoded values. This makes sure the backend always uses the correct
values regardless of firmware version.
- Fixed an "off-by-one" error in the color reordering routine that
caused weird artifacts in some instances.
wrong old installation of libsane.la
$(INSTALL_PROGRAM) libsane.la $(libdir)/libsane.la
to this:
$(LIBTOOL) $(MINST) $(INSTALL_PROGRAM) libsane.la $(libdir)/libsane.la
Oliver Rauch
* AUTHORS: Added Karsten Festag as maintainer of microtek2.
* backend/mustek.* doc/sane-mustek.man: Update to Mustek backend
1.0-100. Added option fast-preview that tries to use the fastest
mode available for preview. This is supported for the 3-pass
scanners (was option "preview in gray") and some of the
ScanExpress scanners (6000 SP, 12000 SP Plus). Use #include
"../include/sane/...". Put option force-wait into mustek.conf
(disabled). Removed block mode for Paragon 6000 SP and 8000 SP.
Code cleanup. More debug output. Details in backend/mustek.CHANGES.
* doc/.cvsignore: Added sane-as6e.5 and sane-nec.5.
* configure configure.in acinclude.m4 aclocal.m4
include/sane/config.h.in: Added test for PTAL library and headers
(patch from David Paschal <paschal@rcsis.co>). Some reformating of
the output of configure --help.
* backend/GUIDE: Updated entry about #include.
* AUTHORS: Removed authors of xscanimage and xcam (now in
sane-frontends).
* README.unixware2, README.unixware7: X-frontends are no longer
included. Removed comments and sourcecode of "rev" (not supported/used
in backends/Makefile anymore).
* sane.lsm: X-frontends are no longer included. Used blanks instead of
tabs.
* doc/scanimage.man: Removed links to backends, added generic link
instead.
* doc/.cvsignore frontend/.cvsignore: X-frontends are no longer included.
* changed configure.in, configure frontend/Makefile.in
and backend/Makfile.in:
The shared libraries required by the backends are linked to
the backends (they have been linked to the frontends before).
Only libintl is linked to the frontend.
* changed tool/sane-config.in, sane-config --libs => "-lsane",
all other libraries are linked to the backend libs now
* doc/scanimage.man doc/saned.man: updated description of password
file
* sanei/sanei_auth.c frontend/saned.c frontend/scanimage.c: replaced
index() by strchr(). Changed style of password file
* backend/net.c: the net backend now prepends net:host: to the
resource before calling the auth_callback function
* changed configure.in and frontend/Makefile.in,
"-lintl" is not added to @LIBS@ any more, @INTLLIBS@
is defined instead now, this is necessary because "-lintl"
has to be added to the frontends and not to a backend and
sane-config --libs must not list it.
* removed xcam.c xscanimage.c sane-style.rc progress.c progress.h preview.c preview.h preferences.c preferences.h gtkglue.c gtkglue.h
from frontend/
* removed parts for xcam and xscanimage from frontend/Makefile.in,
configure.in and updated confiugre
* NEWS: Updated for SANE 1.0.4. Please check.
* README.aix: Removed paragraph about shared libs not working.
* README.linux: Added paragraph about excessive warnings due to glibc
bug (from Peter Kirchgessner).
* TODO: Removed entry about shared libs not working on AIX. Added entry
about PTAL checks. Removed entry about DBG and microtek2. Added entry
about dc210 and jpeg functions. Added entry about using strchr()
instead of index().
* sane.lsm: Added NEC.
* backend/microtek2.c: (from karsten.festag@t-online.de (Karsten
Festag)) Use DBG instead of printf/fprintf. Use
#include "../sane/include/..." instead of #include "sane/...". Fixed
warnings.
* changed configure and configure.in, removed test for sting.h/strings.h
this is not needed because we use strchr instead (always in string.h)
of index (sometimes in string.h, sometimes in strings.h)
* changed ltconfig for aix4*, repleace -o $objdir/$soname by -o $lib,
the shared libraries are handled correct now
* AUTHORS: Added FUKUDA Kazuya for the nec Backend. Used spaces instead
of tabs.
* PROJECTS: Removed entry about NEC. Added/updated entries about Mustek
USB scanners.
* README: Added link to sane-nec(5).
* TODO: Removed entries about sanei_authorize and plain text passwords.
* backend/Makefile.in backend/dll.conf backend/nec.conf backend/nec.c
backend/nec.desc backend/nec.h doc/Makefile.in doc/sane-nec.man:
Added nec backend for the NEC scanners PC-IN500/4C (from Kazuya Fukuda
<fukuda@pjs.nevt.nec.co.jp>)
* configure configure.in: Added test for /dev/urandom and
index() in string.h or strings.h
* backend/net.c: Fixed SANE_NET_AUTHORIZE call handling
* doc/net.tex: Clarified definition of SANE_NET_AUTHORIZE, added
definition of MD5 authorization
* doc/sane.tex: Upgraded to version 1.0.2, changed definition of
SANE_MAX_USERNAME_LEN & SANE_MAX_PASSWORD_LEN to 128 chars
* doc/saned.man: added description of SANE_CONFIG_DIR/saned.users
* doc/scanimage.man: added description of ~/.sane/pass and
--accept-md5-only
* frontend/saned.c: implemented user authorization on a per backend
basis
* frontend/scanimage.c: fixed bug (option -b wasn't present)
implemented auth_callback
* include/sane/sane.h: changed definition of SANE_MAX_USERNAME_LEN &
SANE_MAX_PASSWORD_LEN to 128 chars
* lib/Makefile.in sanei/Makefile.in: updated Makefiles
* PROJECTS: Added entry about Visioneer OneTouch 8600.
* TODO: Added entries about net backend crashing after timeout, stiff.c
problems, and more details about Irix cc jpeg problems.
* doc/sane.tex: Fixed a typo.
* doc/.cvsignore: Added the files produced by make ps.
* README: Removed X-frontends. Point to sane-frontends and website.
Some reformatting.
* TODO: Updated concerning frontends split.
* PROJECTS: Removed entries about frontends (now in
sane-frontends/README)
* PROBLEMS: Removed entries about frontends (now in
sane-frontends/PROBLEMS)
* sanei/sanei_constrain_value.c: If constraint_type is
SANE_CONSTRAINT_RANGE and quantization is used, the results may
be outside the limits of the range because quantization uses the
orginal value. Fixed by doing quantization with the already
checked value.
* TODO: Updated. Added entries for viceo backend and addition to hp
backend. Updated entries about the include issue. Added point about
additional options for pnm backend, install problem of libsane.la,
and some build problems and the --without-x problem. Some more
details for detecting older SANE versions.
* LEVEL2: Added entry about sending messages from backend to frontend.
Removed entry about image polarity.
* backend/mustek.c backend/mustek.h backend/mustek.CHANGES
backend/mustek.desc: Update to Mustek backend 1.0-99. Better
transparency adapter support for ScanExpress scanners. Changed
color support for ScanExpress scanners (faster at some resolutions
now). Paragon 1200 SP color mode should work now without garbage at
the end of an image. Some bugfixes. Details in
backend/mustek.CHANGES.
* tools/find-scanner.c: Explicitly state that find-scanner won't
find non-SCSI scanners.
* doc/scanimage.man: Add examples for SANE device names.
* frontend/scanimage.c: Output message when no devices are found.
Add example for devicename to --help message. Print warning
when a Unix devicename is used instead of a SANE device. Removed
compiler warning.
* TODO: Removed entries about the fgets and include issues in
umax. Removed entries about scanimage device name
documentation. Added a point about xscanimage problems with the
new GIMP API.
* backend/mustek.* doc/sane-mustek.man: Update to Mustek backend
1.0-98. Fixed segmentation fault in sane_init. Enabled double
buffering. Clear inquiry buffer before using. Paragon 1200 SP now
uses LD_BLOCK color correction. Removed LD MFS (wasn't used
anymore). Fix sane_cancel for Paragon series II scanners. Fix
halftone and grain for Paragon series II scanners. Backtracking is
used automaticly by all scanners now. Some safety checks, code
cleanup and more debug output. Details are in
backend/mustek.CHANGES.
if checked option is a range and the value is out of
range the value is now corrected to the minimum or maximum
allowed value and SANE_INFO_INEXACT is set.
The old version returned with an error. This caused problems
when the value was a little bit out of range because of rounding
errors.
Oliver Rauch
* backend/pnm.c: Fixed three segfaults due to buffer overruns:
maximum length of filename wasn't checked; maximum length in
sane_read wasn't always checked; ppm_type wasn't always set in
getparmfromfile. Added some checks for safety and removal of
warnings. Added DBG lines for every SANE API call.
* TODO: Added entries about the backend:devicename issue. Add a
comment about fronends not to crash when length is -1. Added entry
about sane-pie. Added point about fronends not checking if too
much data is delivered with sane_read.
* PROJECTS: Added entry about sane-pie.
* backend/mustek.*: Update to Mustek backend 1.0-97. This is a
development version and is only tested for three-pass scanners.
Added support for Paragon 1200 SP Pro and ScanExpress A3 SP.
Removed detection of " C04" and " C12" (don't seem to exist).
Changed SCSI request scheme. Sane_read can read more than 4096
bytes from pipe. Minimum dpi is 30 now. Fixed LD correction for
Paragon 1200SP 1.06 and 1.11. Read SCSI buffer into big block and
do LD after that for Paragon one-pass scanners. New option
"blocksize" in mustek.conf. Better detection of the scanner type
(three-pass, Paragon I, ...). Fixed possible segmentation faults
in Paragon 600 II N LD code, scsi_sense_wait_ready and
sense_handler. Decreased maximum scan size of Paragon 800 II
SP. For three-pass scanners: fixed stop_scan and speed code, scan
area is in pixels now, added RGB brightness and contrast, use
+-100% for brightness and contrast. Return SANE_STATUS_CANCELLED
when scan was cancelled. Option "force backtracking" is enabled by
default, "scan speed" is set to "fastest". Added option
"force-warn" for mustek.conf. Rewrote halftone mode. Better error
handling and more debug output.
* TODO: Clarified point about image data polarity. Moved point about
xscanimage not updating the progress bar for 3pass scanners to
frontend section. Removed umax entry in "frontends". Removed entry
about alpha channel (was added to LEVEL2 file).
* LEVEL2: Add point about image data polarity.
* frontend/scanimage.c: Removed some warnings.
* README: Removed comment about xscanimage error message. Added
comment about find-scanner (may find scanners not supported by
SANE).
* tools/README: Added comment about find-scanner and some lines
about sane-desc.el and sane-config.
* tools/find-scanner.c: Added comment about scanners not supported
by SANE. Removed some warnings.
* TODO LEVEL2: Removed xscanimage error comment from TODO and moved
ideas for SANE 2.0 from TODO to LEVEL2.
* frontend/xscanimage.c: Fixed gtk_main_quit bug (based on patch
from <moloch@nikocity.de>). An error message was printed when
no sane device was found.