backend/epson.c: Allow more than 8 bit color depth for
preview mode since Xsane can handle this. Some code cleanup.
Removed ancient code that was used to determine the resolution
back when the backend still had a slider for the resolution
selection.
backend/epson.desc: Updated version number, added new scanners.
and config_line bug. Removed entry about make uninstall and
sanei_wire.c bug. Removed entry about microtek update. Added point
about adding sane(7) to any manual page.
Henning Meier-Geinitz <henning@meier-geinitz.de>
Added sense handler to support the GT-8000 scanner.
Also added experimental (and #ifdef protected) USB scanner probing
code - requires patch to USB scanner driver.
* removed a bug in saned (patch by Matthias Trute <mtrute@topmail.de>)
calculation of the reader buffer index was not correct:
if (reader >= sizeof (buf))
- reader = 0;
+ reader -= sizeof(buf);
backend/epson.c:
- Removed check for '\n' before end of line
- Free memory malloced in sane_get_devices() in sane_exit() again
- Check first if the scanner does support the set film type and set
focus position before the GUI elements are displayed.
- This caused problems with older (B4 level) scanners when a TPU
was connected.
help the SANE project. Added comments about possible problems
with old installaitions of SANE and /etc/ld.so.conf. Added section
"REPORTING BUGS".
Henning Meier-Geinitz <henning@meier-geinitz.de>
and to free alloced memory. A bit of reformating. Used
#include "../include/sane/...". Fixed some warnings.
Henning Meier-Geinitz <henning@meier-geinitz.de>
* applied a patch by Douglas Gilbert to sanei_scsi.c
it solves the Problem that the scanner is not
found on linux systems when the order of the
scsi devices is not coverd by the order of
devices listed by /proc/scsi/scsi, it prefers
new kernel 2.4 methods when available
for existing sane installations and plustek memory access violation.
Added Canon FB620S and FS2710 backend and entries about Tru64
compilation problems and installation procedure for translations.
Generate sane-backends.html in doc/. New target: install-mostang.
Installs the sane standard (.ps, .ps.gz and html), the html manpages,
and sane-backends.html on www.mostang.com.
* backend/artec.c: Fixed bug causing possible dereference of a NULL
pointer.
* backend/artec.desc: Modified USB entry to say AS6E scanner supported
by SANE AS6E backend.
* PROJECTS: Added entry for the Fujitsu M3091DCd. Updated my email
address.
* TODO: Added entry for the Fujitsu M3091DCd and a combined Fujitsu
backend. Clarified that "printf" also shouldn't be used.
* backend/dll.desc: Added my email as contact address.
* backend/m3091.desc: New file for the Fujitsu M3091DCd.
* doc/sane-mustek.man: Updated URL.
* backend/mustek.CHANGES backend/umax.CHANGES backend/umax.FAQ
backend/umax.TODO: Moved to doc/mustek respectively doc/umax.
* doc/canon.CHANGES doc/canon.install2700F.txt doc/canon:
Moved canon-specific documentation to doc/canon.
* doc/mustek: New subdirectory for mustek-specific documentation.
* doc/sane-umax*.html doc/sane-umax*.jpg doc/sane-umax-doc.tex
doc/sane-umax-doc.dvi doc/umax: Moved all the umax-specific
documentation to new subdirectory umax.
* backend/agfafogus.c: Moved PATH_MAX after sanei_backend.h include
to avoid warning. Changed printf to DBG.
* backend/mustek.c backend/mustek.CHANGES backend/mustek.desc: Added
support for translating options. Used only PACKAGE_VERSION for
output. Updated email address. New version: 1.0-107.
* include/sane/sanei_backend.h include/sane/saneopts.h: Added macro
SANE_I18N. It's used to mark strings that can be translated and
used by a frontend. Usually these are option titles and descriptions
as well as the contents of string lists. Used this macro to mark
the translatable strings in saneopts.h. More translation support
will follow.
* PROBLEMS: Point to pnm/saned security risks.
* TODO: Removed the entries about epson usb mis-detection and check
for installed sane versions.
* configure configure.in backend/Makefile.in: Added detection of older
versions of SANE. The pnm backend is now disabled by default.
* backend/dll.c backend/dll.desc: Fixed file descriptor leak (found by
Douglas Gilbert). New version: 1.0.2.
* backend/net.desc: Added Jochen Eisinger's email address as contact
for the net backend.
* doc/sane-pnm.man: Point to pnm/saned security risks.
* AUTHORS: Added Michael Herder and me for pnm. Updated my email
address.
* TODO: Removed pnm entry about adding more options. Added entry about
epson backend freezing when trying to detect non-epson USB scanner.
Added entry about adding contact adresses to .desc files. Added
comment about me working on a sane man page. Removed entry about OS/2
problems in sanei_scsi.c.
* configure configure.in: Removed a newline in --help message.
* backend/pnm.c: Added several options: gamma tables
(-> arrays), resolution option (word list), read only test option
(SANE_CAP_SOFT_DETECT), several options for returning status codes
in sane_read (all of this is from Michael Herder <crapsite@gmx.net>).
Added build version info, print version information in sane_init.
Use ../include/sane/ for includes. Version is 1.0.1.
* backend/pnm.desc: Updated contact info and version.
* backend/dc210.desc backend/dc240.desc backend/microtek2.desc:
Update contact information for backends. dc240 status is :NEW.
* TODO: added entries about as6e status shouldn't be :new, and
installing all documentation files.
* README: Updated xsane link.
* configure configure.in backend/dll.c backend/dll.desc
backend/net.c backend/net.desc include/sane/config.h.in
Yet another change in the version system for dll and net.
For sane_init return the version of the package but use
own internal version number in the source (printed with
debugging enabled) and in *.desc. The internal versions
of both net and dll are set to 1.0.1. Please increase the
build number with every change on the source files.
* doc/realeases.txt -> doc/releases.txt. Fixed spelling error.
Added entries about sane-backends.html, sane.ps, man pages,
platforms page.
* PROJECTS TODO: Added entry about E3 USB chipset.
* backend/dll.c backend/dll.desc: New version is 1.0.5. Version and
PACKAGE_VERSION is printed with debug level set to 1 or higher.
The version numbers of all backends that are loaded are printed
at debug level 3 or higher. Print error if backend with wrong
major version number is loaded. Some standardization changes
concerning the DBG messages.
* backend/net.c backend/net.desc: New version is 1.0.5. Version and
PACKAGE_VERSION is printed with debug level set to 1 or higher.
Some standardization changes concerning the DBG messages.
* backend/pnm.c: Return SANE_INFO_RELOAD_PARAMS even if the pnm
file doesn't exist or can't be loaded (from mh <crapsite@gmx.net>).
* doc/backend-writing.txt: Added AUTHORS to the list of things that
should be updated when including a new backend. Added points about
avoiding printf and exit in backends.
* doc/releases.txt: New file. This text summarizes some points to
pay attention to when a new release of sane-backends is made.
Additions and corrections are appreciated.
* doc/scanimage.man: Add some more information about the -V option.
* frontend/scanimage.c: The option -V now also prints the version of
the backend (ususally dll).
* backend/mustek.c backend/mustek.desc backend/mustek.CHANGES
Added detection of the TA for the Paragon 1200 SP Pro. Added
warning about not supported Trust scanners. Changed description
of contarst and brightness settings. Backend status is "stable"
now. New version: 1.0-106.
* acinclude.m4 aclocal.m4: Fixed comment concerning dc240.
* configure configure.in include/sane/config.h.in: Added test for
socklen_t in sys/socket.h. This fixes the compilation problem on
Irix.
* doc/sane-avision.man doc/sane-ricoh.man doc/sane-s9036.man
doc/sane-tamarack.man: find-scanner is now called
sane-find-scanner and installed on the system so it's not
necessary to point to the tools directory.
* frontend/scanimage.c: Fixed too long line in output.
* sane-config.in: Name is sane-config again (was sane-backends-config
due to the renaming of the package).
* TODO: Removed entry about net.c not compiling on Irix and
references to find-scanner in the man pages. Updated numbers of
the compilation warnings. Still too many, however.
* backend/sc240.c backend/dc240.h backend/dc240.conf
backend/dc240.desc backend/dll.conf doc/sane-dc240.man:
Added dc240 backend for the Kodak DC240 Digital camera (from
Peter Fales <peter@fales.com>).
* doc/Makefile.in: Added sane-dc240 in section 5.
* backend/Makefile.in: Added dc240.
* configure configure.in: If the jpeg libs are not available,
dc240 is also disabled.
* AUTHORS: Added entry for dc240 and updated email address of
Peter Fales.
* NEWS: First version of the news entry for 1.0.5.
* PROJECTS: Removed dc240. Added Microrec ScanMaker 3600.
* README: Added dc240.
* TODO: Removed dc240. Added entry about keep-alive mechanism in saned.
* sane-backends.lsm: Added dc240.
* testsuite/.cvsignore: New file. Added entry for Makefile.
* backend/mustek.c backend/mustek.desc backend/mustek.h
backend/mustek.CHANGES: Fixed grascale gamma for the 600 II N.
Fixed ADF problems when selecting windows smaller than the
whole scan area. Fixed linedistcnace corrections issues concerning
ADF and concerning 1200SP V 1.00. New version: 1.0-105.
* backend/bh.c backend/bh.h doc/sane-bh.man
added support for Copiscan 8000 series by Mark Temple
added options deskew and rotation
inquiry compares product to COPISCAN rather than COPISCAN II
* AUTHORS: Added Tom Martone.
* PROJECTS: Removed bh (now included in sane).
* README: Added entry for sane-bh(5).
* TODO: Removed bh. Updated BearPaw entry. Added entry about v4l
problem.
* backend/v4l.c: Changed comment as v4l is part of the sane package.
* backend/bh.c backend/bh.conf backend/bh.h doc/sane-bh.man
Added new backend Bell and Howell Copiscan scanners
* backend/bh.desc
Updated version from (0.1) to 1.0-4
Referenced manpage
* backend/Makefile.in
Added bh to PRELOADABLE_BACKENDS
Added libsane-bh.la dependencies
* doc/Makefile.in
Added sane-bh.5 to SECT5
* backend/mustek.c backend/mustek.desc backend/mustek.h
backend/mustek.CHANGES doc/sane-mustek.man:
Added 36 bit mode for Pro models. Removed support for "special"
modes, used options instead. Code cleanup. Updated manpage
concerning sane-find-scanner. New version: 1.0-104.
* configure: regenerated from configure.in.
* tools/find-scanner.c: Removed. Now called sane-find-scanner.
* tools/sane-find-scanner: New file (was find-scanner).
* tools/.cvsignore tools/Makefile.in tools/README: Updated because
of name change. sane-find-scanner is installed now.
* README README.linux: Updated because of sane-find-scanner.
* frontend/scanimage.man: Updated because of sane-find-scanner.
* doc/sane-find-scanner.man: New file.
* doc/.cvsignore doc/Makefile.in: Added sane-find-scanner(1).
* TODO: Updated concerning sane-find-scanner. Added entry about
qcam /tmp file handling. Some spelling corrections.
* backend/mustek.CHANGES backend/mustek.c backend/mustek.desc
backend/mustek.h doc/sane-mustek.man: Added calibration for Pro
scanners and the SE 12000 SP Plus. Added option to use the full
legal size of the Paragon 1200 LS scanner. Added fast preview for
Pro scanners. Bug fixes. New version: 1.0-103.
Added bit-depth selection again.
Fixed problem with bilevel scanning with Perfection610: The
line count has to be an even number with this scanner.
Several initialization fixes regarding bit depth selection.
This version goes back into the CVS repository, the 1.0.4
release is out and therefore the code freeze is over.
Some general cleanup, added more comments
* TODO: Removed entry about net/saned crashes.
* backend/net.c: Fixed segfault when using SANE_TYPE_STRING options
(e.g. scanimage on localhost). Added checks to prevent other
segfaults. Fixed some warnings.
* backend/snapscan.desc: Changed to use new homepage.