Wykres commitów

4744 Commity (b29ea31da241e57d000e9bf1e2661919af45a548)

Autor SHA1 Wiadomość Data
Henning Geinitz 2dd4b1822c Fixed comment (we still use 30 seconds USB timeout by default). 2005-07-15 18:16:35 +00:00
Henning Geinitz e479c32503 Better 4->8 bit depth expansion algorithm (from Mattias Ellert
<mattias.ellert@tsl.uu.se>).
2005-07-15 18:12:49 +00:00
Oliver Schwartz 74ff64ae24 Updated descriptions for Epson 1670, 2480 and 2580 2005-07-15 17:43:39 +00:00
Rene Rebe e5a5f45497 Updated the Avision backend with the latest off-site maintained version:
fixed segmentation faults for some modes, many many new devices, two
different duplex modes are supported, vast speedup of multi page batch scans,
buttons as well a 7-segment LED readout and some quirks for old scanners not
filling all fields
2005-07-15 09:12:27 +00:00
Rene Rebe e5193fdcae Added support to set the USB timeout. 2005-07-15 09:02:02 +00:00
Henning Geinitz 38cc925c4b Changed resolution from 75 to 100 dpi and changed 16 bit/color to 12 based on a
user report for the Visioneer OneTouch 7300. Updated .desc. Moved check for
stable lamp to its own function. Mustek ScanExpress A3 USB: Use CIS
calibration. Use lamp warmup. Fixed CCD on GT6801 scanning (color scanning was
broken due to a change in motormode_2.
2005-07-10 20:58:58 +00:00
Henning Geinitz 56e3295552 Make sure that getopt is not built on OS/2 (from Franz Bakan <fbakan@gmx.net>). 2005-07-09 13:19:51 +00:00
Henning Geinitz 1cfaf7a3ce Updated Danish translation (from Mogens Jaeger <mogensjaeger@get2net.dk>). Made
sure that no errors occur because xgettext/xmsgfmt think that "%" is a C format
string. Regenerated all po files.
2005-07-09 12:58:20 +00:00
Frank Zago e3aceaf492 *** empty log message *** 2005-07-07 11:57:27 +00:00
Frank Zago 483e472841 New email address. 2005-07-07 11:55:43 +00:00
Gerhard Jaeger ae92358fed * doc/plustek/Plustek-USB.changes: Update.
* backend/plustek.c: Fixed scanarea calculation.
* backend/plustek-usbshading.c: Fixed fine-white calibration.
2005-07-07 09:59:26 +00:00
Gerhard Jaeger 9b7c4f73c8 Fixed fine-white calibration. 2005-07-07 09:59:04 +00:00
Gerhard Jaeger aeeaed58e4 Fixed scanarea calculation. 2005-07-07 09:57:35 +00:00
Gerhard Jaeger f3607fbb48 Update. 2005-07-07 09:56:58 +00:00
Gerhard Jaeger 5fed7f058e removed not needed backend status. 2005-07-05 06:50:04 +00:00
Gerhard Jaeger 5b97232b43 * doc/descriptions-external/epkowa.desc: Updated according to
the info provided by  Olaf Meeuwissen <olaf.meeuwissen@avasys.jp>
2005-07-05 06:46:14 +00:00
Gerhard Jaeger c34d40408f Updated according to the info provided by
Olaf Meeuwissen <olaf.meeuwissen@avasys.jp>
2005-07-05 06:45:11 +00:00
Gerhard Jaeger 0a91e0b533 * backend/plustek.[ch] backend/plustek-usbscan.c
backend/plustek-usbshading.c backend/plustek-usbdevs.c
  backend/plustek-usbdevs.c backend/plustek-usbimg.c
  backend/plustek-usbmap.c backend/plustek-usbhw.c
  backend/plustek-usbcal.c backend/plustek-usb.[ch]:
  Added button support, did some cleanup, added IPC between
  reader- and parent-process.
2005-07-04 09:55:01 +00:00
Gerhard Jaeger 18764ad4a9 Added button support, did some cleanup, added IPC between
reader- and parent-process.
2005-07-04 09:54:31 +00:00
Gerhard Jaeger 6002a6163d Update. 2005-07-04 09:50:22 +00:00
Ulrich Deiters a97d0bf43c inserted definition for SSIZE_MAX 2005-07-04 07:01:53 +00:00
Henning Geinitz 161a58ace0 Updated for sane-backends 1.0.16. 2005-07-03 16:12:10 +00:00
Henning Geinitz 3db60263e8 Typo/formatting fixes. 2005-07-03 13:58:21 +00:00
Henning Geinitz 9932061d41 Removed. Scanners have been moved to doc/descriptions/genesys.desc and
doc/descriptions/unsupported.desc.
2005-07-03 13:50:45 +00:00
Henning Geinitz 74cd84acb5 Added links to scanners with GL646 and GL841 chipsets. Moved all unsupported
scanners from doc/descriptions-external/genesys.desc to unsupported.desc. Minor
fixes for other scanners.
2005-07-03 13:46:52 +00:00
Henning Geinitz cb0ed1be00 Used "Medion/Lifetec/Tevion/Cytron" as manufacturer as in the other
backends. Used "ScanJet 2300C" as model name as in other backends.
2005-07-03 13:40:08 +00:00
Henning Geinitz e9f761d067 Don't check the result of usb_find_busses(). Based on patch from Julien BLACHE
<jb@jblache.org>.
2005-07-03 13:35:48 +00:00
Ulrich Deiters 20aff8e022 restored actual version of the Canon-SCSI backend 2005-07-01 19:21:55 +00:00
Stéphane Voltz 8f102afe79 - fixed missing modifications for genesys backend inclusion 2005-06-30 19:46:06 +00:00
Gerhard Jaeger 68a968ecd3 * tools/RenSaneDlls.cmd backend/dll.c: Fixed OS/2 restriction for
dlopening DLLs on OS/2, as it only works for 7.3 filenames for
  some reason (patches by Franz Bakan <fbakan@gmx.net>
2005-06-30 08:19:06 +00:00
Gerhard Jaeger b0dd4470cc Fixed OS/2 restriction for dlopening DLLs on OS/2, as
it only works for 7.3 filenames for some reason
(patches by Franz Bakan <fbakan@gmx.net>.
2005-06-30 08:18:29 +00:00
Stéphane Voltz bce76371c4 - added genesys backend from experimental area 2005-06-27 20:07:45 +00:00
Gerhard Jaeger 38e6ad0adb * backend/plustek.c: Fixed "double free" problem in sane_exit.
* doc/plustek/Plustek-USB.changes: Update.
2005-06-27 07:09:15 +00:00
Gerhard Jaeger e633318ba4 Update. 2005-06-27 07:08:33 +00:00
Gerhard Jaeger 25ad5f2280 Fixed "double free" problem in sane_exit. 2005-06-27 07:08:09 +00:00
Mattias Ellert a21fe44c4f sane-desc needs $(LIBLIB) 2005-06-26 09:56:24 +00:00
Mattias Ellert 4b5a6494fc Update Swedish translation 2005-06-26 04:40:54 +00:00
Henning Geinitz 67b85ddb0d Added "Ethernet" to list of possible interfaces. 2005-06-19 16:08:34 +00:00
Henning Geinitz 8cd6e6533f Added several models, updated others. 2005-06-19 16:04:20 +00:00
Henning Geinitz dbbc9e7820 Removed misleading comment. 2005-06-19 15:59:52 +00:00
Henning Geinitz 61409cb5bd Removed Samsung SCX-4216F (supported by samsung backend). Dell 1600n has also
network connection.
2005-06-19 15:56:23 +00:00
Henning Geinitz d4b441310f Added Canon CanoScan LiDE 500F. 2005-06-12 14:57:46 +00:00
Henning Geinitz 7dda4a0306 Fixed comments. 2005-06-04 13:45:26 +00:00
Henning Geinitz 04e085c532 New. Listed scanners supported by the new external brother2 backend. 2005-06-04 13:43:03 +00:00
Henning Geinitz 6de5708e4f Added Genius ColorPage-SF600. 2005-06-04 13:33:13 +00:00
Karl Heinz Kremer a245023c10 Added CX-4600 to desc file. 2005-05-31 01:14:55 +00:00
Henning Geinitz 6fd1ee367e Start exposure with the settings from the scanner entry. CIS
Calibration and exposure uses a broader spectrum now. Expsoure
	  limit is increased to 50 loops. Genius Vivid 4x is reported to
	  work so the UNTESTED label is removed now. Visioneer 7300 is
	  reported to work so the UNTESTED label is removed now. Genius
	  ColorPage Vivid 1200XE: Removed UNTESTED label. Fixed
	  resolutions. Adjusted margins. Fixed color order. Fixed
	  linedistance. Adjusted AFE. Mustek ScanExpress 1248 UB: Fixed
	  margins. Adjusted AFE. Adjusted exposure. Adjusted
	  gamma. Changed status to "complete". Mustek BearPaw 2400 CU
	  Plus: Adsusted exposure and AFE parameters. Hopefully stripes
	  and similar trouble are gone now. Mustek BearPaw 1200 CU:
	  Increased exposure to avoid vertical lines. Updated manual page.
2005-05-29 19:58:56 +00:00
Henning Geinitz ceaa2ddade Updated, mostly concerning kernel scanner driver (deprecated). Minor fixes. 2005-05-29 19:55:15 +00:00
Henning Geinitz 95be6202fa Status of Samsung SCX-4100 is "good" asit's reported to work. 2005-05-29 19:52:39 +00:00
Henning Geinitz 350c73aba3 Fixed missing link for Genius ColorPage-Slim 1200 USB2. 2005-05-28 18:56:25 +00:00