Wykres commitów

30 Commity (99ee355d03a1208390fdffde04b8785a5bd56703)

Autor SHA1 Wiadomość Data
Henning Geinitz b600c81c26 Added Mustek ScanExpress 1248 UB and new version of Mustek BearPaw 1200 CU Plus. 2004-08-08 10:00:02 +00:00
Henning Geinitz 75a39c06d7 Updated to backend version 61. Lots of fixes for coarse calibration, scanning
speed and several scanners. For details, see gt68xx.CHANGES.
2004-06-18 09:49:32 +00:00
Henning Geinitz f723898b2b Minor fixes for Mustek BearPaw 2448 TA Plus. 2004-04-19 18:01:48 +00:00
Henning Geinitz c187441e94 Minor fixes for Mustek A3 USB, Genius ColorPage Vivid4 and Mustek BearPaw 2448
CS/TA Plus.
2004-04-10 17:30:36 +00:00
Henning Geinitz 3593f24a3d Added BGR color order for pixel mode. Plustek OpticPro U16B works
in color mode now. Made 600 dpi mode for Mustek BearPaw 2400 TA
	  Plus a bit faster. Changed Mustek ScanExpress A3 linedistance
	  correction. Added detection of Visioneer Onetouch 7300.
2004-04-04 18:59:49 +00:00
Henning Geinitz 46ed7dab4d Plustek U16B: Added GT68XX_FLAG_SE_2400. Fixed color order.Increased debug level
for setup_scan. Fixed CCD ocarse calibration.
2004-03-28 18:26:38 +00:00
Henning Geinitz aafcfe6a8e Genius Vivid 4xe now has color order RGB. Removed 50 dpi for Mustek BearPaw 2448
as that resolution doesn't work. Make sure that the lamp of the Mustek A3 USB
gets warmed up. It's a CIS scanner with a lamp. That code is untested. Full scan
starts scanning from the start position of the white strip now. Added detection
for Genius Vivid 1200 EX. Fixed product id of Mustek BearPaw 2448 TA Plus. Other
minor updates.
2004-03-19 18:55:35 +00:00
Henning Geinitz 820b9ba269 Added basic support for Plustek OpticSlim 2400. Fixed calibration debug output. 2004-02-10 19:02:03 +00:00
Henning Geinitz 6026b31f36 Debug options are only enabled if the debug level is 1 and higher. Added product
id 0x0402 for Plustek U16B.
2004-01-19 17:35:57 +00:00
Henning Geinitz a4dc00b0ed Fixed a bug in the stop scan function for Plustek U16b. Added support for Genius
Vivid4xe.
2004-01-05 18:16:04 +00:00
Henning Geinitz 0de37be6f6 Updated code for Genius Vivid 4x and Mustek ScanExpress A3 USB. Added Genius
Colorpage Vivid3 V2 and Googlegear 2000 as supported devices.
2003-12-14 19:02:32 +00:00
Henning Geinitz 0ed2b19fd7 Added Mustek BearPaw 2448 TA Plus. Added special command set for Plustek
U16B. Added Plug-n-Scan 2400 M(T) to list of devices. No positive report yet.
Used request for memory writes and reads instead of a fixed value of 0x04. Set
Genius Vivid4x to GT6816. Untested. All changes have not been tested on their
respective scanners yet.  New version: 1.0.50.
2003-11-23 21:14:43 +00:00
Henning Geinitz 4de7e23e89 Added detection of Genius Vivid 4x. It won't work out-of-the-box, however. CCD coarse calib
shouldn't run into an endless loop anymore. Plustek 1248U is much faster now.
2003-09-30 17:37:56 +00:00
Gerhard Jaeger dbcb3c853f Added Plustek OpticSlim 1200 to gt68xx backend. 2003-09-30 06:48:42 +00:00
Henning Geinitz 05c12190be Added Genius 3x as working scanner, removed testing flag. Added Artec 2000 e+
to manpage. Added detection for the Plustek OpticPro U16B.
2003-04-27 12:43:43 +00:00
Henning Geinitz eda0c4bc5e Updated Mustek BearPaw 1200 CU Plus white strip value. Set Mustek ScanExpress
A3 USB to CCD. Black mark may be still wrong. Minor formatting changes in the
manpage.  Decreased ScanExpress A3 USB status to alpha because of CIS/CCD
change.
2003-04-11 09:37:24 +00:00
Henning Geinitz a84d4a611f Added Packard Bell Diamond 1200 Plus to .desc and manpage. New flag to avoid
running stop_scan before doing a scan. The Windows firmware of the BearPaw
1200 CU Plus doesn't seem to like that.
2003-03-13 17:18:29 +00:00
Henning Geinitz a04ea4b251 Make sure that the firmware for plustek-like scanners is loaded. Didn't work
for Genius vivid3xe.  Added both Genius scanners to man page. Removed warning
from Genius Vivid3xe.
2003-03-02 22:08:50 +00:00
Henning Geinitz 4b00890161 Added Genius Colorpage Vivid3xe. Added request_type and request fields to the
command set. Request is 0x01 or 0x04.
2003-02-27 17:31:52 +00:00
Henning Geinitz 57e852ea8a List BearPaw 2400 CS Plus as supported. Make fast preview the default
(otherwise BP 2400 TA Plus wouldn't work with 12/16 bits). Added vid/pid
0x07b3/0x0400, that's another Plustek OpticPro 1248U.
2003-02-16 21:31:45 +00:00
Henning Geinitz 5b79536901 Fixed resolutions for BearPaw 1200 TA. Increase the lowest black for CCD
coarse calibration. Adjusted internal gamma correction.  CCD scanners use
color mode for coarse+quality cal now. Preview isn't always in 8 bit mode now
(can be selected by option). Upper and lower limits for coarse calibration are
unified now. Added options for adjusting gain and offset.
2003-02-05 16:02:45 +00:00
Henning Geinitz 6d895dbc7b Removed wrong "untested" flag from Mustek AE USB and Lexmark X70/X73 scanners. 2003-01-18 11:46:15 +00:00
Henning Geinitz 9f0d82980b Updated manpage and .desc concerning Lexmark X70. Updated manpage concerning
kernel 2.4.21-pre3 containing the 1-endpoint fix. Fixed A3 USB resolution
setting. Updated A3 USB margins (Pedro Morais <morais@inocam.com>). Added
detection of Genius Colorpage Vivid3x.  It's unknown if it works. Updated
.desc file. Don't print calib line warnings by default.
2003-01-09 18:05:01 +00:00
Henning Geinitz b97a0721b5 Updated ScanExpress 2400 USB values. Added implementation of gt6801 lamp
control for CCD scanners. Added flag for SE 2400 USB, added some quirks in
gt68xx_gt6801.c. Fixed gt68xx_gt6801 -> lamp control. Adjusted Plustek 1248U
geometry and afe values. CCD gross calibration changed: start with the default
value from module struct. Is faster now for most cases. Only 2.5 mm of
calibration for GT-6801 scanners. Added "afe" option for gt68xx.conf for
selecting default afe values. Removed AFE and exposure SANE options. Added
documentation for afe option in gt68xx.conf. New version: 1.0-35.
2002-12-30 13:05:24 +00:00
Henning Geinitz 7f699acfe3 Coarse calibration for first scan only" is off by default now. Added gamma
table factor option (SANE_CAP_EMULATED). Setup gamma to 2.0 by default.  Fixed
(hopefully) sigpipe when cancelling. No geometry quantization anymore (not
necessary). Plustek 1248U: do linemode for every resolution, fix color
correction. Added comments for every Model member in gt68xx_devices.  Added
Plustek UT16B and Genius Vivid3x to .desc. Added implementation for inverted
offset for CCD scanners. Added Mustek ScanExpress 2400 USB. Well, at least
it's detected. Added NEW marker to .desc.
2002-12-08 21:00:31 +00:00
Henning Geinitz 089b24e539 Changed 150 to 200 dpi for Mustek BearPaw 2400 TA. Fixed warnings in
gt68xx_low.c. Used DBG instead of XDBG ing gt68xx_low.c.  Minor manpage
fixes. Added man page links to other backends.  gt68xx_low.h: Fixed
__FUNCTION__ bug on non-gcc compilers.  Added more details about the BSDs in
the manpage. Fixed color order for ScanExpress A3 USB.
2002-11-21 22:09:16 +00:00
Henning Geinitz 4ef48fd6e6 Added basic support for Plustek OpticPro 1248U (from Gerhard Jaeger
<gerhard@gjaeger.de>). Removed 50 and 1200 dpi from Lexmark X73.  Backend
status is BETA now.
2002-11-13 17:45:24 +00:00
Henning Geinitz 1eee8d286e Changed option titles and descriptions to make them better readable. Added
translation markers for all options. Added German translation for backend
options. Updated manpage and .desc file concerning scanner status. Added
untested flag for Mustek ScanEpress A3 USB and Lexmark X73.
2002-11-07 12:50:19 +00:00
Henning Geinitz 7b590a0cde Faster AFE calibration. Minor fixes. New version: 1.0-28. 2002-10-31 19:50:44 +00:00
Henning Geinitz 492b63060f Added gt68xx backend for scanners based on the Grandtech GT-6801
and GT-8616 chips like The Mustek BearPaw CU, and TA scanners
and some Artec Ultima 2000 clones.
2002-10-25 12:16:15 +00:00