Wykres commitów

7703 Commity (5c70148451cdcad571870367ca6ec1bbd92a3502)

Autor SHA1 Wiadomość Data
Rolf Bensch 5c70148451 changelog for recent work 2013-03-15 22:58:19 +01:00
Rolf Bensch 64b5884b30 update doc files for MG6300 2013-03-15 22:49:49 +01:00
Rolf Bensch 8c075ae0a0 fix image post processing for 1200dpi and 2400dpi 2013-03-15 22:44:22 +01:00
Rolf Bensch d8242a49a5 new scanner Canon Pixma MG6300 2013-03-15 22:39:54 +01:00
m. allan noah cb943124b8 Fujitsu backend v115
- separate s->mode into s_mode and u_mode
- separate s->params into s_params and u_params
- generate grayscale and binary in software if required (iX500)
2013-03-11 21:11:38 -04:00
Stéphane Voltz 7e4095d30d change HAVE_USBCALL define back to HAVE_USBCALLS 2013-03-07 07:24:33 +01:00
Oliver Schwartz cfecc1fbf6 Added support for Acer/Benq Scanwit 2720S film scanner by Andrew Goodbody in snapscan backend. 2013-03-04 23:40:44 +01:00
m. allan noah a56d62356a ignore genesys doxygen conf file 2013-03-01 21:57:54 -05:00
m. allan noah 3c2bbdc7c3 Fujitsu backend v114
- support resolutions > 300 for iX500 using diag_preread()
- remove most communication with scanner during sane_control_option()
2013-03-01 21:57:54 -05:00
Stéphane Voltz f93258f047 changelog for sanei_usb.c change 2013-02-28 22:25:05 +01:00
Stéphane Voltz ef52b75473 free devname only in the case of a reused device slot 2013-02-28 22:23:03 +01:00
Rolf Bensch d9b2fa3c87 ease installation procedure
- use ldconfig instead of symbolic links
- use subchapters
2013-02-28 18:02:12 +01:00
Stéphane Voltz e2924f062e remove extra blank 2013-02-27 21:32:41 +01:00
Stéphane Voltz ab4fd6450b entry for genesys.desc change 2013-02-27 21:32:04 +01:00
Stéphane Voltz 37999a9672 update changelog entry for rts8891/lexmark changes 2013-02-27 21:30:27 +01:00
Stéphane Voltz 8d1f440c27 chnage G2410 status to at basic 2013-02-27 21:28:09 +01:00
Stéphane Voltz 80a00344f9 changelog for lexmark and rts8891 backends cleanups 2013-02-27 21:28:09 +01:00
Stéphane Voltz 54742a1831 cppcheck errors and warnings fixes 2013-02-27 21:26:29 +01:00
Stéphane Voltz 6b78c69876 cppcheck errors and warings fixes 2013-02-27 21:26:28 +01:00
Rolf Bensch d7d91aa1e0 fix installation path for libsane.la 2013-02-27 12:49:38 +01:00
m. allan noah b7361d987c Oops- should not have enabled new frame types 2013-02-23 15:05:37 -05:00
m. allan noah 36523e547d fujitsu backend v113
- support for ScanSnap iX500
- fix bug with jpeg de-interlacing code
- allow has_MS_* and has_pixelsize to be set in init_model
- fix use of uninitialized buffer in send_lut
- add send_q_table()
- allow wait_scanner() to be bypassed in object_position
- moved send_lut() to after set_window
2013-02-23 14:57:00 -05:00
m. allan noah 96628ed13f fujitsu backend v112
some scanners (fi-6x70 and later) don't enable IPC by default
fix minor compiler warning
2013-02-22 21:06:12 -05:00
Gerhard Jaeger 8e9f89c1b2 Update to reflect recent changes. 2013-02-22 09:08:29 +01:00
Gerhard Jaeger 69a2ec6801 Fix another bug in the libusb1 part of functioin check_libusb_device()
that prevents sanner detection for certain devices.
2013-02-22 09:07:32 +01:00
Gerhard Jaeger 65773982fe Reflect latest change 2013-02-20 20:03:16 +01:00
Gerhard Jaeger 54f6a05c0f Fixed typo 2013-02-20 20:01:53 +01:00
Gerhard Jaeger e42af77c2a Update to reflect recent changes. 2013-02-20 08:30:55 +01:00
Gerhard Jaeger ef5820ce62 Free heap memory, acquired via strdup for
devname, in sanei_usb_close().
2013-02-20 08:30:34 +01:00
Gerhard Jaeger 74eb71fa19 Setup libusb1 debugging after initialization
otherwise a segfault appears in triple -v mode.
2013-02-20 08:24:52 +01:00
Rolf Bensch 985bd91064 changelog for recent work 2013-02-18 18:53:30 +01:00
Rolf Bensch b3d96a3a4a update doc files 2013-02-18 18:53:06 +01:00
Rolf Bensch 0349a3ddda push backend version to 0.17.2 2013-02-18 18:48:13 +01:00
Rolf Bensch a087139805 update German translations for Canon Pixma scanners 2013-02-18 18:33:30 +01:00
Rolf Bensch 11ad6252fb scan IR channel with CS9000F 2013-02-18 18:07:50 +01:00
Rolf Bensch df33c7223f ease crop scan resolution to allowed values
add crop scan resolution for PIXMA_SCAN_MODE_TPUIR
2013-02-18 17:54:57 +01:00
Rolf Bensch f254809c0b new capability PIXMA_CAP_TPUIR
new scan mode PIXMA_SCAN_MODE_TPUIR
2013-02-18 17:37:30 +01:00
Rolf Bensch bb3806313d new device parameters tpuir_min_dpi and tpuir_max_dpi
only for Canoscan devices
2013-02-18 17:17:55 +01:00
Rolf Bensch 18c2ceb66f ease create_mode_list() and create_dpi_list()
- read the settings direct from (pixma_sane_t *ss)
2013-02-18 16:20:57 +01:00
Rolf Bensch 53c87a381e rename ext* to adftpu* 2013-02-18 16:03:18 +01:00
Stéphane Voltz 15bdce9211 changelog entry for genesys backend changes 2013-02-13 22:01:26 +01:00
Stéphane Voltz 93e0d5f9b1 correct freeing of data 2013-02-13 21:53:17 +01:00
Stéphane Voltz 46c398e33f add declaration for unit tests
remove USB mode set
2013-02-13 21:53:17 +01:00
Stéphane Voltz b0edb1cd99 putative fix for SUB data transfer problem 2013-02-13 21:53:17 +01:00
Stéphane Voltz c62d5879a7 cppcheck fixes
- cppcheck fixes
- new macro to hanlde free on error path
- better error message in RIEx macros
2013-02-13 21:53:17 +01:00
Stéphane Voltz 1fb646582b cppcheck fixes 2013-02-13 21:53:17 +01:00
Gerhard Jaeger 58b896ee60 Updated 2013-02-13 14:31:52 +01:00
Gerhard Jaeger 67c57fb1e6 Added recent changes/updates for Plustek-PARPORT backend to Changelog. 2013-02-13 14:31:18 +01:00
Gerhard Jaeger 947197f508 Update to support Kernel version 3. 2013-02-13 14:30:26 +01:00
Gerhard Jaeger ac564e89f6 Fixed kernel module build for recent kernels
Defined internal "ULong" types to be in fact 32 bit wide,
this should fix issues on 64 bit machines.
2013-02-13 14:29:52 +01:00