Wykres commitów

3122 Commity (4cf4d8dd7fe92ef92626b8498424a7494d276608)

Autor SHA1 Wiadomość Data
Julien BLACHE 4cf4d8dd7f Add an optional connection timeout option for the net backend. This can be used to prevent the backend from hanging for several minutes when the saned server is unresponsive. 2007-10-24 10:32:46 +00:00
Stéphane Voltz 76b0c6d7e8 - added rts8801/rts8891 detection 2007-10-19 15:12:48 +00:00
Pierre Willenbrock d60b98bfca use sizeof(Genesys_Register_Set) instead of 2 2007-10-13 14:36:49 +00:00
Bertrik Sikken 3583622d04 Updated with changes for 2007-10-07 2007-10-07 11:18:19 +00:00
Julien BLACHE 2b3275c001 Mark the Brother DCP-117C support as good and add USB IDs, based on user report. 2007-10-02 09:41:26 +00:00
Stéphane Voltz 148e4bb599 - fixed compilation warnings 2007-10-01 05:03:06 +00:00
Stéphane Voltz dce6df9182 - moved experimental version to current tree 2007-10-01 04:27:24 +00:00
Stéphane Voltz 8c638f5802 - added the 'Genius ColorPage-Life Pro' as supported by the
umax_pp backend
2007-10-01 03:53:56 +00:00
Bertrik Sikken c389f15de8 Added changes for 2007-09-28 2007-09-28 13:59:06 +00:00
Bertrik Sikken 8da8e2373f Added changes for 2007-09-25 2007-09-28 11:19:31 +00:00
Julien BLACHE 929f057596 Fix typos in backend-writing.txt. 2007-09-27 09:30:25 +00:00
Julien BLACHE 82602663f3 Added pointer to http://code.google.com/p/kvss905c/ for the Panasonic KV-SS905C and Panasonic KV-S3105C scanners. 2007-09-26 18:49:51 +00:00
Bertrik Sikken daaa446403 Added changes for 2007-09-23 (unsupported.desc) 2007-09-23 21:36:59 +00:00
Gerhard Jaeger 1b3fc23141 #305009 removed UMAX3400, as it is supported by the Plustek backend 2007-09-17 06:03:26 +00:00
Giuseppe Sacco d19db5e776 * Italian translation update
* Corrected a typo in backend/canon.c
2007-08-28 21:13:04 +00:00
Stéphane Voltz c0ee8a2143 - mail address update
- minor man update
2007-08-27 04:58:53 +00:00
Stéphane Voltz 825ff7335e * genesys/gl646: HP2400 warmup fix by Luke <iceyfor@gmail.com> 2007-08-26 09:49:18 +00:00
Henning Geinitz a55ccf9ad0 Name and email address change. 2007-08-19 13:33:24 +00:00
Henning Geinitz 4b83c2d24c Added Artec Ultima 2000 e+, Nortek Myscan 1200, NeatReceipts Scanalizer
Professional, Genius Colorpage Slim-1200. Name and email address changes.
2007-08-19 13:30:46 +00:00
Julien BLACHE f4a6016611 Added various USB IDs. 2007-08-18 12:06:36 +00:00
Henning Geinitz 6ca105af27 Added. 2007-08-12 16:58:06 +00:00
m. allan noah b2666cada5 scanimage: bugfix, dont round up negative user input values
fujitsu.desc: add/consolidate new models
2007-08-08 12:46:02 +00:00
Julien BLACHE 94f0ce1b00 Add the Epson Stylus CX-6600 (04b8:0813) based on user report. 2007-08-03 11:34:31 +00:00
Julien BLACHE 6d6e4271e0 Add the Epson Stylus Photo RX-700 (04b8:0810). 2007-08-03 11:31:15 +00:00
m. allan noah c8e8f2c41a scanimage.c: add default: blocks to switch statements so recent gcc will shutup
fujitsu.[ch]: update to backend v1.0.52:
- remove unused jpeg function
- reactivate look-up-table based brightness and contrast options
- change range of hardware brightness/contrast to match LUT versions
- call send_lut() from sane_control_option instead of sane_start
2007-07-31 18:07:53 +00:00
Julien BLACHE 2db8ec7d98 Add the Epson Stylus DX-5050 (04b8:082b). 2007-07-31 11:48:49 +00:00
Julien BLACHE ff5387ffa0 Apply patch from Nils Philippsen, turning 3 logical AND into bitwise AND (SANE bug #304363). 2007-07-30 13:42:39 +00:00
Julien BLACHE 964eccff2c Add Epson Stylus DX-5000 (04b8:082b) based on several reports. 2007-07-30 13:36:52 +00:00
Julien BLACHE ef05fcdbad Add Epson Stylus DX4050 (04b8:082f) based on several reports. 2007-07-30 13:32:34 +00:00
Julien BLACHE 08f6df7b48 Add a RUN rule to the udev rules to automatically disable USB suspend for all known scanners.
This effectively works around the hardware bugs exposed by CONFIG_USB_SUSPEND.

Works only with kernels >= 2.6.22 where /sys/bus/usb/devices/*/power/level exists.
2007-07-29 18:39:54 +00:00
m. allan noah 86c976274a update to backend v1.0.51, fix jpeg bug when using adf 2007-07-27 00:54:07 +00:00
Julien BLACHE d5d762f96e Revert my last commit and rework the one before to produce a backward compatible udev rules file. Yay. 2007-07-26 21:23:27 +00:00
Gerhard Jaeger c9fbdd4073 * doc/plustek/Plustek-USB.changes: Update
* backend/plustek.c: Bumped build number
* backend/plustek-usbhw.c: Force output bit set on misc I/O,
  when lamp is switched
* doc/descriptions/unsupported.desc: Updated some Plustek entries
2007-07-26 20:42:18 +00:00
Julien BLACHE 8dc1f4493c Update udev rules for use with Linux >= 2.6.22 and CONFIG_USB_DEVICE_CLASS=n. 2007-07-25 09:21:18 +00:00
Wittawat Yamwong c4af52e84a Updated pixma backend to version 0.13.1
Added PIXMA MP960
2007-07-19 22:17:21 +00:00
m. allan noah 44e085b331 update website in manpage 2007-07-16 00:42:24 +00:00
m. allan noah 048161249d * doc/descriptions/fujitsu.desc: update website and fi-60F status
* Authors, backend/dll.conf.in: added cardscan backend
2007-07-16 00:39:24 +00:00
m. allan noah 41761fede4 add new backend for Corex CardScan 800c, small-format sheetfed usb scanner
for cards/receipts, etc.
2007-07-15 01:46:47 +00:00
m. allan noah 5973ebe12d add new models and fix bug in man page
drop sanei_thread.lo from libsane-fujitsu.la (fujitsu backend single threaded)
2007-07-15 00:59:14 +00:00
Gerhard Jaeger aec768f551 * tools/check-usb-chip.c: Try to distinguish the various
GenesysLogic GeneScan ASICS - GL841, GL842 and GL843
2007-07-11 20:55:03 +00:00
m. allan noah e343cc59cf * backend/fujitsu.[ch], backend/fujitsu-scsi.h: update to v1.0.50,
add JPEG support, usb command sending and scan params cleanups
* include/sane/sane.h: add SANE_FRAME_JPEG
* frontend/scanimage.c: dont crash on unknown frame types
2007-07-10 16:07:25 +00:00
Gerhard Jaeger 05868435b9 * backend/plustek-usb.h backend/plustek-usbdevs.c backend/plustek.c:
Added flag to allow only 1- and 8-bit scanmodes. The Q-Scan does
  not seem to support 14-bit modes.
2007-07-10 09:02:22 +00:00
Gerhard Jaeger 5b31b57a3a doc/descriptions/plustek.desc: Fixed web entries 2007-07-10 06:19:10 +00:00
Gerhard Jaeger b0778e41a9 * backend/plustek-usb*.[ch] backend/plustek.[ch]:
Added sheetfed device Q-Scan USB001 from Portable Peripherals
  Fixed Mustek Bearpaw and made some speedup (bugreports #304343 and
  #301763)
  Fixed calibration for senororders other that RGB
* doc/descriptions/plustek.desc: Bumped version and added Q-Scan
* doc/descriptions/unsupported.desc: Removed Q-Scan
* doc/sane-plustek.man doc/plustek/Plustek-USB.changes: Update
2007-06-29 08:40:33 +00:00
m. allan noah 26d0e072ee update to v 1.0.49. add fi-5750C and S510 2007-06-28 17:53:09 +00:00
Julien BLACHE 5dcf165795 Switch sanei_scsi to the SG_IO ioctl interface, instead of the
asynchronous SG3 read/write interface.

Makes it possible to use SCSI scanners in 32/64bit mixed environments,
thanks to the ioctl 32bit compatibility layer, which is NOT possible
using the SG3 interface.
2007-06-21 19:35:53 +00:00
Gerhard Jaeger dd7aa7403b * doc/plustek/Plustek-PARPORT.changes: Update.
* backend/plustek_pp.c: Bumped build number.
* backend/plustek-pp_drv.c backend/plustek_pp_sysdep.h:
  Make the Kernelmodule work with Kernels > 2.6.15 w/o DEVFS
2007-06-18 20:29:45 +00:00
Ilia Sotnikov 9f6424d266 + Use libtool instead of ar/ranlib, which correctly handles dependencies
(eg. for parallel makes)
2007-06-12 06:40:29 +00:00
Mattias Ellert a75a509bcc Updated localization files 2007-05-08 11:46:24 +00:00
Ilia Sotnikov 18160038f1 * backend/hp5590_low.c: don't use libusb structs directly, define
necessary of them by ourselves ('struct usb_ctrl_setup' -> 'struct
  usb_in_usb_ctrl_setup')
* backend/hp5590_low.c: renamed 'struct usb_bulk_setup' to 'struct
  usb_in_usb_bulk_setup' to show its internal usage
2007-04-29 15:08:43 +00:00