HP ScanJet 4500C/4570C/5500C is supported by the 'hp5590' backend.
* doc/descriptions/hp5590.desc:
Updated backend version, added HP ScanJet 4500C as completely supported,
added HP ScanJet 5500C as untested, HP ScanJet 4570C/5550C/5590/7650
marked as completely supported
* tools/check-usb-chip.c:
Updated HP ScanJet model names displayed during the check_hp5590().
* backend/hp5590.c, backend/hp5590_cmds.c, backend/hp5590_cmds.h,
backend/hp5590_low.c, backend/hp5590_low.h, doc/sane-hp5590.man:
Updated the list of supported devices (added HP 5500C which is similar
to 4570C, 5500C which is similar to 4500C) - only strings/comments, no
code was changed. Updated backend version. Updated man page.
- Updated the list of supported devices (HP 5500C which is similar to
4570C, 5500C which is similar to 4500C) - only strings/comments, no
code was changed
- Updated backend version
- Updated man page
- Updated backend version
- Added HP ScanJet 4500C as completely supported
- Added HP ScanJet 5500C as untested
- HP ScanJet 4570C/5550C/5590/7650 marked as completely supported
Network fds are of no use to the Avahi process and can cause the net
backend to hang when saned is run in debug mode.
This only happens if the net backend tries to connect to saned a second
time and manages to establish the connection before saned has completed
its shutdown.
There is some potential for this to also occur when saned is run in
standalone mode but it's far less probable as the window is a lot smaller.
Add in missing $PTHREAD_LIBS to all backends that can make use of it.
Rename --enable-fork-process to --enable-pthread to maatch internal
logic. Also, stop linking in pthreads needlessly if its been
disabled.
* configure, configure.in: version 1.0.21cvs
* doc/releases.txt: minor updates for new build system
* doc/descriptions/canon_dr.desc, doc/descriptions/coolscan3.desc,
doc/descriptions/rts8891.desc, doc/descriptions/xerox_mfp.desc:
remove :new tag
with newer automake.
* backend/Makefile.am, tools/sane-config.in: Add missing
$GPHOTO2_LDFLAGS so library can be found.
* tools/Makefile.am: Add mising $SCSI_LIBS to sane-find-scanner.
* po/sane-backends.de.po: updates from Burkhard Luck
* po/Makefile.am, po/Makefile.in, po/sane-backends.en_GB.po: new
translation from Andrew Coles
* po/*.po: rebuilt with new strings
doc/descriptions/fujitsu.desc: add S1500 usb ids and status
* backend/canon_dr.c: update credits
* doc/sane-fujitsu.man doc/sane-canon_dr.man: update version numbers,
dates, credits and known issues
* doc/saned.man: remove section about uncontrolled data port range
- return cmd status for reads of sensor options
* backend/canon_dr.c, doc/descriptions/canon_dr.desc: backend v26
- return cmd status for reads of sensor options
- allow rs to adjust read length for all bad status responses