Wykres commitów

35 Commity (41c181b062f699d4f2469839935e809d593d3a47)

Autor SHA1 Wiadomość Data
Mattias Ellert a65178b7bb Man page fixes 2005-11-24 20:17:43 +00:00
Henning Geinitz fb40be18dc Added support for Plustek OpticSlim M12 (untested). Based on patch from Gerhard
Jaeger <gerhard@gjaeger.de>. Fixed gt68xx homepage links in man page. Changed
minimum version of libusb to 0.1.8.
2005-09-29 18:22:30 +00:00
Henning Geinitz b19e6c5262 Fixed the problem concerning scanning on *BSD. Scanning only worked once (bug
#300597). Fixed compilation warnings.
2005-08-18 19:26:09 +00:00
Henning Geinitz 6fd1ee367e Start exposure with the settings from the scanner entry. CIS
Calibration and exposure uses a broader spectrum now. Expsoure
	  limit is increased to 50 loops. Genius Vivid 4x is reported to
	  work so the UNTESTED label is removed now. Visioneer 7300 is
	  reported to work so the UNTESTED label is removed now. Genius
	  ColorPage Vivid 1200XE: Removed UNTESTED label. Fixed
	  resolutions. Adjusted margins. Fixed color order. Fixed
	  linedistance. Adjusted AFE. Mustek ScanExpress 1248 UB: Fixed
	  margins. Adjusted AFE. Adjusted exposure. Adjusted
	  gamma. Changed status to "complete". Mustek BearPaw 2400 CU
	  Plus: Adsusted exposure and AFE parameters. Hopefully stripes
	  and similar trouble are gone now. Mustek BearPaw 1200 CU:
	  Increased exposure to avoid vertical lines. Updated manual page.
2005-05-29 19:58:56 +00:00
Henning Geinitz f5aaa34eed Updates of supported scanners. 2004-10-02 16:21:37 +00:00
Henning Geinitz 42aab25d25 Fixed firmware name for Mustek 1248 UB. Changed status to basic. Removed
"unsupported" warning.  Added workaround for shared memory compilation problem
on Windows. It's now possible to add a new vendor/product id line to gt68xx.conf
to test yet unsupported scanners without changing the source code.
2004-09-03 14:06:19 +00:00
Henning Geinitz c187441e94 Minor fixes for Mustek A3 USB, Genius ColorPage Vivid4 and Mustek BearPaw 2448
CS/TA Plus.
2004-04-10 17:30:36 +00:00
Henning Geinitz 3593f24a3d Added BGR color order for pixel mode. Plustek OpticPro U16B works
in color mode now. Made 600 dpi mode for Mustek BearPaw 2400 TA
	  Plus a bit faster. Changed Mustek ScanExpress A3 linedistance
	  correction. Added detection of Visioneer Onetouch 7300.
2004-04-04 18:59:49 +00:00
Henning Geinitz aafcfe6a8e Genius Vivid 4xe now has color order RGB. Removed 50 dpi for Mustek BearPaw 2448
as that resolution doesn't work. Make sure that the lamp of the Mustek A3 USB
gets warmed up. It's a CIS scanner with a lamp. That code is untested. Full scan
starts scanning from the start position of the white strip now. Added detection
for Genius Vivid 1200 EX. Fixed product id of Mustek BearPaw 2448 TA Plus. Other
minor updates.
2004-03-19 18:55:35 +00:00
Henning Geinitz 820b9ba269 Added basic support for Plustek OpticSlim 2400. Fixed calibration debug output. 2004-02-10 19:02:03 +00:00
Henning Geinitz 6026b31f36 Debug options are only enabled if the debug level is 1 and higher. Added product
id 0x0402 for Plustek U16B.
2004-01-19 17:35:57 +00:00
Henning Geinitz 561b7501e1 Added Packard Bell Diamond 2450. 2004-01-13 21:07:16 +00:00
Henning Geinitz a4dc00b0ed Fixed a bug in the stop scan function for Plustek U16b. Added support for Genius
Vivid4xe.
2004-01-05 18:16:04 +00:00
Henning Geinitz 0de37be6f6 Updated code for Genius Vivid 4x and Mustek ScanExpress A3 USB. Added Genius
Colorpage Vivid3 V2 and Googlegear 2000 as supported devices.
2003-12-14 19:02:32 +00:00
Gerhard Jaeger dbcb3c853f Added Plustek OpticSlim 1200 to gt68xx backend. 2003-09-30 06:48:42 +00:00
Henning Geinitz 7a6f2ddf61 Added Mustek ScanMagic 1200 UB Plus. Minor bugfix. 2003-08-27 11:49:52 +00:00
Henning Geinitz d5ce45d9c5 Added Fujitsu 1200CUS to man page, .conf and .desc. Changed .conf file to be
more readable.  Added RevScan 19200i to .conf file.  Added Plustek U16B to
.desc and .conf, updated UT16B.
2003-07-25 07:41:58 +00:00
Henning Geinitz 29635dcec2 Added RevScan 19200i. Updated device status entries. 2003-06-19 14:31:15 +00:00
Henning Geinitz 5a5dd8adb0 Fixed wrong example. 2003-05-15 11:09:54 +00:00
Henning Geinitz 05c12190be Added Genius 3x as working scanner, removed testing flag. Added Artec 2000 e+
to manpage. Added detection for the Plustek OpticPro U16B.
2003-04-27 12:43:43 +00:00
Henning Geinitz eda0c4bc5e Updated Mustek BearPaw 1200 CU Plus white strip value. Set Mustek ScanExpress
A3 USB to CCD. Black mark may be still wrong. Minor formatting changes in the
manpage.  Decreased ScanExpress A3 USB status to alpha because of CIS/CCD
change.
2003-04-11 09:37:24 +00:00
Henning Geinitz a84d4a611f Added Packard Bell Diamond 1200 Plus to .desc and manpage. New flag to avoid
running stop_scan before doing a scan. The Windows firmware of the BearPaw
1200 CU Plus doesn't seem to like that.
2003-03-13 17:18:29 +00:00
Henning Geinitz 0bb508a879 Small requests are done with a response buffer of 8 bytes (instead of 64)
now. Looks like GT-6816 based scanners return 8 bytes if the firmware is
loaded and 64 bytes if it's not loaded. Changed GT-6816 firmware check to
ignore errors from above change. GT-6816 scanners work with the BSDs now (at
least once). Updated manpage concerning the BSDs.
2003-03-06 14:27:54 +00:00
Henning Geinitz a04ea4b251 Make sure that the firmware for plustek-like scanners is loaded. Didn't work
for Genius vivid3xe.  Added both Genius scanners to man page. Removed warning
from Genius Vivid3xe.
2003-03-02 22:08:50 +00:00
Henning Geinitz a0251b6cc1 Added vid/pid 0x07b3/0x0400 to gt68xx.conf also. Added indormation about
Medion 4394. Mention ma1509 backend. Fix segfault when calling sane_open with
an empty device name.
2003-02-22 15:34:51 +00:00
Henning Geinitz 57e852ea8a List BearPaw 2400 CS Plus as supported. Make fast preview the default
(otherwise BP 2400 TA Plus wouldn't work with 12/16 bits). Added vid/pid
0x07b3/0x0400, that's another Plustek OpticPro 1248U.
2003-02-16 21:31:45 +00:00
Henning Geinitz 4b4f26f500 Updated status for the BSDs. 2003-01-11 23:47:30 +00:00
Henning Geinitz 9f0d82980b Updated manpage and .desc concerning Lexmark X70. Updated manpage concerning
kernel 2.4.21-pre3 containing the 1-endpoint fix. Fixed A3 USB resolution
setting. Updated A3 USB margins (Pedro Morais <morais@inocam.com>). Added
detection of Genius Colorpage Vivid3x.  It's unknown if it works. Updated
.desc file. Don't print calib line warnings by default.
2003-01-09 18:05:01 +00:00
Henning Geinitz b97a0721b5 Updated ScanExpress 2400 USB values. Added implementation of gt6801 lamp
control for CCD scanners. Added flag for SE 2400 USB, added some quirks in
gt68xx_gt6801.c. Fixed gt68xx_gt6801 -> lamp control. Adjusted Plustek 1248U
geometry and afe values. CCD gross calibration changed: start with the default
value from module struct. Is faster now for most cases. Only 2.5 mm of
calibration for GT-6801 scanners. Added "afe" option for gt68xx.conf for
selecting default afe values. Removed AFE and exposure SANE options. Added
documentation for afe option in gt68xx.conf. New version: 1.0-35.
2002-12-30 13:05:24 +00:00
Henning Geinitz 7f699acfe3 Coarse calibration for first scan only" is off by default now. Added gamma
table factor option (SANE_CAP_EMULATED). Setup gamma to 2.0 by default.  Fixed
(hopefully) sigpipe when cancelling. No geometry quantization anymore (not
necessary). Plustek 1248U: do linemode for every resolution, fix color
correction. Added comments for every Model member in gt68xx_devices.  Added
Plustek UT16B and Genius Vivid3x to .desc. Added implementation for inverted
offset for CCD scanners. Added Mustek ScanExpress 2400 USB. Well, at least
it's detected. Added NEW marker to .desc.
2002-12-08 21:00:31 +00:00
Henning Geinitz 7cd9688e1f Added missing quotes around PACKAGEVERSION. 2002-11-29 18:50:27 +00:00
Henning Geinitz 089b24e539 Changed 150 to 200 dpi for Mustek BearPaw 2400 TA. Fixed warnings in
gt68xx_low.c. Used DBG instead of XDBG ing gt68xx_low.c.  Minor manpage
fixes. Added man page links to other backends.  gt68xx_low.h: Fixed
__FUNCTION__ bug on non-gcc compilers.  Added more details about the BSDs in
the manpage. Fixed color order for ScanExpress A3 USB.
2002-11-21 22:09:16 +00:00
Henning Geinitz 4ef48fd6e6 Added basic support for Plustek OpticPro 1248U (from Gerhard Jaeger
<gerhard@gjaeger.de>). Removed 50 and 1200 dpi from Lexmark X73.  Backend
status is BETA now.
2002-11-13 17:45:24 +00:00
Henning Geinitz 1eee8d286e Changed option titles and descriptions to make them better readable. Added
translation markers for all options. Added German translation for backend
options. Updated manpage and .desc file concerning scanner status. Added
untested flag for Mustek ScanEpress A3 USB and Lexmark X73.
2002-11-07 12:50:19 +00:00
Henning Geinitz bc2a2f1d1c Added documentation for gt68xx backend. 2002-10-25 12:19:34 +00:00