m. allan noah
56ae50027a
* doc/descriptions/fujitsu.desc, doc/sane-fujitsu.man: backend v80
2008-10-10 00:51:31 +00:00
Nicolas Martin
1aa1677ef2
Changes for ADF simplex and duplex scan, MP970 4800 dpi and TPU scan.
2008-10-05 20:42:19 +00:00
m. allan noah
48e23ca24e
* doc/descriptions/fujitsu.desc, backend/fujitsu.conf.in,
...
backend/fujitsu.[ch], backend/fujitsu-scsi.h: backend v79
- add usb ids for several models
- print additional hardware capability bits
- detect front-side endorser
- disable endorser-side controls if only one side installed
- add quirks for fi-6x70
2008-10-02 04:03:31 +00:00
Gerhard Jaeger
98de411d6c
Added entry for OpticSlim 2400plus
2008-10-01 11:44:54 +00:00
Gerhard Jaeger
bb2e71643b
Removed entry for UT12 devid 0x0013
...
Cleanup
2008-10-01 10:36:03 +00:00
Gerhard Jaeger
24f5d10762
Added entry for UT12 devid 0x0013
2008-10-01 10:35:36 +00:00
m. allan noah
0bbf8bac04
2008-09-25 m. allan noah <kitno455 a t gmail d o t com>
...
* backend/epjitsu.[ch], backend/epjitsu-cmd.h: backend v 13, 14 and 15:
- add working page-height control
- add working brightness, contrast and threshold controls
- add disabled threshold curve and geometry controls
- move initialization code to sane_get_devices, for hotplugging
- support S300 on USB power
- support S300 225x200 and 600x600 scans
- support for automatic paper length detection (parm.lines = -1)
- expose hardware buttons/sensors as options for S300
* doc/descriptions/epjitsu.desc: change S300 status to good
2008-09-25 03:15:49 +00:00
Nicolas Martin
5ab0b2024c
Changes for MP970 (to be continued), add MX7600 pid (untested yet).
2008-09-13 12:32:52 +00:00
Nicolas Martin
286dbd885d
Doc update, CCD sensors white lines padding fix, enhance scan area adjustments.
2008-09-07 19:08:25 +00:00
m. allan noah
72894d1e98
* doc/descriptions/fujitsu.desc: mark fi-6230 and fi-6240 complete
2008-08-27 17:50:47 +00:00
m. allan noah
08d54b457a
* backend/fujitsu.c, doc/descriptions/fujitsu.desc: backend v78
...
- recent model names (fi-6xxx) dont end in 'C'
- simplify flatbed area overrides
- call scanner_control to change source during sane_start
2008-08-26 17:04:30 +00:00
Gerhard Jaeger
8e75357955
Added entry for Strobe XP100
2008-08-25 20:29:56 +00:00
Gerhard Jaeger
8968a4a58a
Removed entry for Strobe XP100
2008-08-25 20:29:24 +00:00
m. allan noah
ad02a8f1ac
set lots of scanners to complete status :)
2008-08-24 02:40:54 +00:00
m. allan noah
852411f3f4
* backend/fujitsu.[ch]: backend v76
...
- add independent maximum area values for flatbed
- override said values for fi-4220C, fi-4220C2 and fi-5220C
* doc/descriptions/fujitsu.desc: bump version, add 2 untested scanners
2008-08-14 03:56:17 +00:00
Rene Rebe
b975ac1fcd
* backend/fujitsu.c, backend/fujitsu.conf.in,
...
doc/descriptions/fujitsu.desc: backend v75
- added fi-6230 ID, updated fi-6130, fi-6230 status
2008-08-07 08:21:51 +00:00
m. allan noah
ea2a506cba
fujitsu backend v73
...
- add fi-6130 usb ID
- correct overscan dimension calculation
- provide correct overscan size overrides for fi-5110C and fi-4x20C2
- fi-5750C can't handle 10 bit LUT via USB
2008-07-27 23:29:12 +00:00
m. allan noah
887b008e7c
* AUTHORS: Earle has commit perms
...
* doc/descriptions/unsupported.desc: add Lexmark X7170
* include/sane/sanei_config.h: remove typedef so doxygen will shutup
2008-07-26 05:34:28 +00:00
m. allan noah
4f4ce809ba
* backend/fujitsu.[ch]: backend v72,
...
- use mode_sense to determine background color support
- remove fi-5900 background color override
2008-07-14 00:59:26 +00:00
Nicolas Martin
b17fddd55b
A few changes for ADF source scanning, updated MX850 description.
2008-07-05 12:42:53 +00:00
m. allan noah
40e5aaa7fe
* backend/fujitsu.[ch], backend/fujitsu-scsi.h: backend v68,
...
- add halftone type and pattern options
- support M3097G with IPC and CMP options via modified VPD response
* doc/descriptions/fujitsu.desc, doc/sane-fujitsu.man: backend v68,
- manpage cleanup
2008-07-02 20:43:49 +00:00
m. allan noah
f3ed5342cc
backend version 65, add endorser support, add quirks for fi-4990
2008-06-25 02:30:54 +00:00
Ilia Sotnikov
249681dbc6
+ Added support for HP ScanJet 4570c (thanks to Markham Thomas)
2008-06-19 11:03:49 +00:00
m. allan noah
ad779e0865
backend version 64,
...
use model and serial to build sane.name (idea from Ryan Duryea),
allow both serial_name and device_name to sane_open scanner,
simulate missing VPD data for M3097G, probe scanner for color
interlacing mode instead of hardcoding, other minor cleanups
2008-05-30 08:47:38 +00:00
m. allan noah
2016e8f019
backend version 1.0.62, begin sane 1.1.0 compliance
2008-05-21 02:27:14 +00:00
m. allan noah
f6f4de5d5d
* doc/descriptions/cardscan.desc, doc/descriptions/epjitsu.desc,
...
doc/descriptions/hp3900.desc, doc/descriptions/hp5590.desc,
doc/descriptions/hpljm1005.desc, doc/descriptions/hs2p.desc:
remove 'new' tag from sane 1.0.19 backends
* doc/descriptions/fujitsu.desc, backend/fujitsu.conf.in:
add fi-5530C2 usb ID
* backend/cardscan.c: correct version number
* backend/epjitsu.conf.in: improved firmware directions
* backend/fujitsu.[ch]: update to backend v 1.0.61
2008-05-16 02:31:57 +00:00
Nicolas Martin
a2933d5207
USB IDs updates in imageClass backend (pixma), by Dennis Lou.
2008-05-07 06:51:01 +00:00
Stéphane Voltz
1eb416ba47
- description update for untested HP4400 model
...
- 150 dpi mode fix for HP4470 models sold with XPA
2008-05-06 20:00:32 +00:00
Nicolas Martin
3f86915941
Description and man updates for PIXMA MX300.
2008-05-05 21:20:50 +00:00
Nicolas Martin
9ee0385130
Code cleanup patch to imageClass backend (pixma) by Dennis Lou.
2008-05-04 17:34:20 +00:00
m. allan noah
16f5a83f8d
fujitsu: support new fi-6x20
...
epjitsu: mention new S300M
2008-04-23 01:55:34 +00:00
Nicolas Martin
8e5710ca1c
Updated release version of pixma backend.
2008-04-22 19:30:14 +00:00
Nicolas Martin
fcc26f51e1
Update descriptions for Canon ImageCLASS series MFPs.
2008-04-21 19:24:46 +00:00
m. allan noah
39458249b5
backend version 1.0.58:
...
- page code 32 is not color interlacing, rename to 'unknown'
- increase number of bytes in response buffer of init_ms()
- protect debug modification code in init_ms() if NDEBUG is set
- proper async sane_cancel support
- re-enable JPEG support
- replace s->img_count with s->side
- sane_get_parameters(): dont round up larger than current paper size
- sane_start() rewritten, shorter, more clear
- return values are SANE_Status, not int
- hide unused functions
2008-04-20 01:31:29 +00:00
Nicolas Martin
983e8c0eeb
Update for MP970 (yet for color scan, all resolutions) and bug fix for MP220 at 1200 dpi (reported to work OK)
2008-04-15 21:27:34 +00:00
Nicolas Martin
d9d44cbe72
Added a tempo before failing in NO PAPER in ADF scan, declared MX850, changed MP970 to Generation 3.
2008-04-02 20:13:48 +00:00
Stéphane Voltz
b85ec879da
- rts8891 backend inclusion
2008-03-22 14:33:36 +00:00
Nicolas Martin
52ec47a434
Added Canon PIXMA MX700, declared MX300 and MX310, and updated some descriptions.
2008-03-16 16:33:53 +00:00
Stéphane Voltz
5be6af9c72
- removed scanners supported by the lexmark backend from
...
unsupported.desc
- umax_pp small copyright refresh
2008-03-02 15:01:13 +00:00
Gerard Klaver
430d0d77ed
Update with Dexxa 4800 support information
2008-03-01 12:32:02 +00:00
Nicolas Martin
bf6f5936e8
Update for PIXMA MP140 now working with pixma backend
2008-02-24 09:24:49 +00:00
Nicolas Martin
5ff80f5f36
Changed MP140 comment to not working yet
2008-02-22 21:43:46 +00:00
Nicolas Martin
2738f8f5b8
Changed name: MultiPass MP710 and MP740 to Pixma MP710 and MP740
2008-02-18 20:49:46 +00:00
Nicolas Martin
a1265b6dad
New models changes:
...
- added: Pixma MP210, MP470, MP520, MP610
- added: MultiPASS MP710
- declared untested: MP140, MP220, MultiPASS MP740
- declared experimental and untested: MP970
Bugs and fixes
- multipage documents scan no more fails with non-ADF MPs
- IO Fail bug when scanning large pages e.g. with Xsane
- implement send_time message form MP710, MP730 family
- run indent -gnu on all pixma_* source files.
2008-02-17 15:49:43 +00:00
Jonathan Bravo Lopez
e1f9664106
Added support for a new scanner: HP ScanJet G2710
...
Minor changes
2008-02-13 06:35:26 +00:00
m. allan noah
2c5ba93ff4
add usb id
2008-02-09 23:57:59 +00:00
m. allan noah
65fa50cd4d
add usb ids
2008-02-08 00:27:50 +00:00
m. allan noah
a330f4b2d8
fix snapscan bug, add LiDE 600F
2008-01-29 17:48:42 +00:00
Alessandro Zummo
6322e207ef
added epson2 .desc file
2008-01-23 17:06:46 +00:00
m. allan noah
6f8f3765f1
remove 'new' flag
2008-01-23 01:51:09 +00:00
m. allan noah
5afcaa4489
adding hpljm1005 backend (i know, i know, so much for feature freeze :)
...
latest .fr updates
2008-01-18 01:27:22 +00:00
m. allan noah
58045b775b
updated fr translation from Yann E. MORIN, added S500M usb id to fujitsu
2008-01-17 01:03:43 +00:00
m. allan noah
522ec3b895
oops- added wrong id for CX-6600
2008-01-09 00:52:05 +00:00
m. allan noah
777c3f4d9c
added cx-6300 (same as 64 and 6600?)
2008-01-08 01:58:32 +00:00
m. allan noah
45665e35c8
missed one
2008-01-07 09:41:55 +00:00
m. allan noah
17a7caebaf
various description updates to clean up the bug tracker.
2008-01-07 09:37:56 +00:00
m. allan noah
a006d79939
mark epson unsupported, remove ricoh and fujitsu from unsupported list
2008-01-06 21:38:58 +00:00
m. allan noah
dc61dc4471
add new hs2p backend for ricoh is450 series scanners
2008-01-03 02:42:32 +00:00
m. allan noah
d3cc1b13a8
backend version 1.0.10- fix missing function
2007-12-19 22:14:19 +00:00
Mattias Ellert
4bb074f81c
New translation keys for hp3900 backend. Updated Swedish translation
2007-12-19 10:47:04 +00:00
m. allan noah
5a574ccb66
html converter only likes lowercase hex
2007-12-18 03:08:13 +00:00
m. allan noah
559212e96e
Adding v1.0.9 of the epjitsu backend: supports Epson-based Fujitsu scanners,
...
currently the fi-60F flatbed and ScanSnap S300 duplex ADF machines
2007-12-18 02:02:51 +00:00
Jonathan Bravo Lopez
46376814f2
Added files for 'hp3900' backend
2007-12-13 00:26:08 +00:00
m. allan noah
b4e05e5e23
update to backend version 1.0.53
...
- add ID for S510
- note jblache's NUM_OPTS type fix
2007-11-18 01:48:20 +00:00
Gerhard Jaeger
85c089c91d
Added support for TravelScan464
2007-11-08 19:53:14 +00:00
Gerhard Jaeger
09742ab30a
Updated some entries
2007-11-08 19:47:12 +00:00
Julien BLACHE
f5a4d0af2b
Added the Epson DX-6000 (04b8:082e) based on user report.
2007-10-28 09:57:44 +00:00
Julien BLACHE
4cf4d8dd7f
Add an optional connection timeout option for the net backend. This can be used to prevent the backend from hanging for several minutes when the saned server is unresponsive.
2007-10-24 10:32:46 +00:00
Bertrik Sikken
e510006077
Added Epson Stylus DX4450 description
2007-10-08 18:50:52 +00:00
Bertrik Sikken
ca35c21cfc
Added Brother MFC-2500 description
2007-10-08 18:44:23 +00:00
Bertrik Sikken
c64f523589
Added CanoScan LiDE 90 description
2007-10-07 11:15:42 +00:00
Bertrik Sikken
abe3c7326d
Added Plustek OpticSlim 500 description
2007-10-07 11:11:08 +00:00
Bertrik Sikken
b57a00502f
Added Visioneer 9420 description
2007-10-07 11:05:20 +00:00
Bertrik Sikken
ff482a9207
Updated Agfa Duoscan T2000XL description
2007-10-07 10:54:30 +00:00
Bertrik Sikken
f7d50cd5e4
Added Kodak i260 description
2007-10-07 10:48:44 +00:00
Bertrik Sikken
1d3e9cfe89
Updated Visioneer Onetouch 8900 description
2007-10-07 10:42:34 +00:00
Bertrik Sikken
2af6357bc5
Added Lexmark X3450 description
2007-10-07 10:29:16 +00:00
Bertrik Sikken
aed8b74913
Added Ricoh IS450 description
2007-10-07 10:01:52 +00:00
Bertrik Sikken
6f0b681ea5
Added DR-4010C description
2007-10-07 09:40:06 +00:00
Bertrik Sikken
f1bd5626d8
Added Benq 5450 description
2007-10-07 09:26:09 +00:00
Stéphane Voltz
dce6df9182
- moved experimental version to current tree
2007-10-01 04:27:24 +00:00
Stéphane Voltz
8c638f5802
- added the 'Genius ColorPage-Life Pro' as supported by the
...
umax_pp backend
2007-10-01 03:53:56 +00:00
Bertrik Sikken
55d33cf903
Added Plustek PL812 description
2007-09-28 13:50:19 +00:00
Bertrik Sikken
eff43923d4
Added Benq 5550 description
2007-09-28 13:44:21 +00:00
Bertrik Sikken
6bf8170e17
Added ScanMaker S400 description
2007-09-28 13:10:11 +00:00
Bertrik Sikken
ed31842a08
Added Fujitsu fi-60F description
2007-09-28 12:59:55 +00:00
Bertrik Sikken
214252d178
Added Microtek ScanMaker 3860 description
2007-09-28 12:44:31 +00:00
Julien BLACHE
82602663f3
Added pointer to http://code.google.com/p/kvss905c/ for the Panasonic KV-SS905C and Panasonic KV-S3105C scanners.
2007-09-26 18:49:51 +00:00
Bertrik Sikken
2b00ac844a
Added Nikon LS-9000 ED description
2007-09-25 19:36:41 +00:00
Bertrik Sikken
35a0a657c8
Added Canon DR-7580 description
2007-09-25 18:46:35 +00:00
Bertrik Sikken
45c0fb7cc1
Added Tamarack Artiscan 2400FS description
2007-09-25 18:28:47 +00:00
Bertrik Sikken
53f7c2d377
Added Primax Onetouch 8920 description
2007-09-25 18:20:26 +00:00
Bertrik Sikken
d6dbb069ab
Added Microtek artixscanDI 2020 description
2007-09-25 17:57:39 +00:00
Bertrik Sikken
a19a40ae0b
Fixed uppercase USB id for Samsung SCX-4725FN
2007-09-23 22:47:32 +00:00
Bertrik Sikken
753deea4ab
Added Hewlett-Packard ScanJet G4050 description.
2007-09-23 21:48:17 +00:00
Bertrik Sikken
9c3ffc119d
Added Plustek PL806 description.
2007-09-23 21:31:10 +00:00
Bertrik Sikken
d2b5f0bbe8
Added Visioneer Strobe XP 300 description.
2007-09-23 21:16:31 +00:00
Bertrik Sikken
96c6e7b163
Fixed Hewlett-Packard Scanjet G4000 link. Added G4010.
2007-09-23 21:06:00 +00:00
Bertrik Sikken
222682dbfc
Added Samsung SCX-4725FN description.
2007-09-23 20:37:17 +00:00
Bertrik Sikken
5ba33efd1c
Added Lexmark X1250 and X1290 descriptions.
2007-09-23 20:23:36 +00:00
Bertrik Sikken
fdd9ab1be6
Added Hewlett-Packard Photosmart C3180 info
2007-09-23 19:30:35 +00:00
Bertrik Sikken
d40a256e14
Removed Genius ColorPage Slim 1200 because it is already listed as 'untested' for the gt68xx backend
2007-09-23 18:56:00 +00:00
Bertrik Sikken
3b88cf6cd2
Added PIE PF3650 description
2007-09-23 18:34:58 +00:00
Bertrik Sikken
ba47afd344
Added LexMark X8350 info
2007-09-23 18:13:04 +00:00
Gerhard Jaeger
1b3fc23141
#305009 removed UMAX3400, as it is supported by the Plustek backend
2007-09-17 06:03:26 +00:00
Henning Geinitz
4b83c2d24c
Added Artec Ultima 2000 e+, Nortek Myscan 1200, NeatReceipts Scanalizer
...
Professional, Genius Colorpage Slim-1200. Name and email address changes.
2007-08-19 13:30:46 +00:00
Julien BLACHE
f4a6016611
Added various USB IDs.
2007-08-18 12:06:36 +00:00
m. allan noah
b2666cada5
scanimage: bugfix, dont round up negative user input values
...
fujitsu.desc: add/consolidate new models
2007-08-08 12:46:02 +00:00
Julien BLACHE
94f0ce1b00
Add the Epson Stylus CX-6600 (04b8:0813) based on user report.
2007-08-03 11:34:31 +00:00
Julien BLACHE
6d6e4271e0
Add the Epson Stylus Photo RX-700 (04b8:0810).
2007-08-03 11:31:15 +00:00
Julien BLACHE
2db8ec7d98
Add the Epson Stylus DX-5050 (04b8:082b).
2007-07-31 11:48:49 +00:00
Julien BLACHE
964eccff2c
Add Epson Stylus DX-5000 (04b8:082b) based on several reports.
2007-07-30 13:36:52 +00:00
Julien BLACHE
ef05fcdbad
Add Epson Stylus DX4050 (04b8:082f) based on several reports.
2007-07-30 13:32:34 +00:00
Gerhard Jaeger
890735a81e
Updated some Plustek entries
2007-07-26 20:41:24 +00:00
Wittawat Yamwong
c4af52e84a
Updated pixma backend to version 0.13.1
...
Added PIXMA MP960
2007-07-19 22:17:21 +00:00
m. allan noah
048161249d
* doc/descriptions/fujitsu.desc: update website and fi-60F status
...
* Authors, backend/dll.conf.in: added cardscan backend
2007-07-16 00:39:24 +00:00
m. allan noah
41761fede4
add new backend for Corex CardScan 800c, small-format sheetfed usb scanner
...
for cards/receipts, etc.
2007-07-15 01:46:47 +00:00
Gerhard Jaeger
1af405f31d
Fixed web entries
2007-07-10 06:18:46 +00:00
Gerhard Jaeger
64382b400b
Bumped version and moved Q-Scan to plustek.desc
2007-06-29 08:34:54 +00:00
m. allan noah
26d0e072ee
update to v 1.0.49. add fi-5750C and S510
2007-06-28 17:53:09 +00:00
Ilia Sotnikov
345ef5a7fe
+ Added description for 'hp5590' backend which supports
...
HP ScanJet 5550/5590/7650 scanners
2007-04-24 17:58:33 +00:00
Mattias Ellert
78ff28cb83
Adding new external backend hp5590
2007-04-21 16:17:56 +00:00
Troy Rollo
ee413cf781
HP3500 backend:
...
Improve speed and reduce noise of most resolutions
Deal with an escape code discovered in the scanner's protocol
Use hardware detailed calibrations for resolutions up to 300
Use improved software detailed calibration for other resolutions
Add more debug information
Drop the 25dpi resolution
Make 200dpi the default (the same as the Windows frontend)
Add code (not used yet) to deal partially with grayscale and
lineart scanning
Use I18N strings where appropriate
2007-04-21 07:19:14 +00:00
m. allan noah
51965d59ec
move some models to 'untested', everything else to good!
2007-04-15 19:20:55 +00:00
m. allan noah
641a50e7e5
add a couple models, move some discontinued ones.
2007-04-15 19:02:53 +00:00
Wittawat Yamwong
efced87595
Remove Canon PIXMA MP160 & MP600 from unsupported. (supported by pixma)
2007-04-14 23:32:40 +00:00
Mattias Ellert
833ae68aca
Moved 3 scanners from unsupported to hp3900
2007-04-13 20:17:05 +00:00
m. allan noah
47cb655c19
update to backend v1.0.47
2007-04-13 15:50:20 +00:00
Wittawat Yamwong
459d5c7e8e
* Updated to version 0.13.0
...
* Added MP160, MP180, MP460, MP510 and MP600
* Fixed a buffer-overflow bug in sane_read()
2007-04-09 20:41:25 +00:00
m. allan noah
5f60b3ac4a
add usbid
2007-03-09 02:15:18 +00:00
Henning Geinitz
e486896f0e
Added Canon Imagerunnerseries.
2007-01-28 16:58:19 +00:00
Henning Geinitz
313a5f80b6
Added .conf entry for Pluste OpticPro S12 and S24. Updated .desc file.
2007-01-28 15:58:40 +00:00
Henning Geinitz
e8a59a97df
Added UMAX Astra 2850.
2007-01-28 15:58:09 +00:00
m. allan noah
4eabb3820c
updated to backend version 1.0.44, updated maintainer email addy
2007-01-27 01:42:13 +00:00
Jochen Eisinger
50a260fee3
2006-01-21 Jochen Eisinger <jochen@penguin-breeder.org>
...
* doc/descriptions/mustek_pp.desc: Cybercom is a CIS scanner
2007-01-21 21:51:00 +00:00
Mattias Ellert
cc8acd0d7e
Adding Visioneer Strobe Pro USB to unsupported
2007-01-19 14:52:14 +00:00
Henning Geinitz
7bb5933bca
Updated.
2007-01-15 23:46:37 +00:00
Henning Geinitz
db352cc1b7
Updated status of UMAX 2000.
2006-11-22 20:17:30 +00:00
Henning Geinitz
b8b81f00d5
Added several scanners, fixed the USB id for Microtek 4850 (bug #304151 ).
2006-11-22 20:16:09 +00:00
Henning Geinitz
9b46fe372c
Added HP Photosmart C5100 and ScanJet 8390.
2006-10-31 19:22:19 +00:00
Henning Geinitz
8cd0f282a9
Added Canon Canoscan 4400F, LiDE 70, Corex Cardscan 700 C, Umax Astra 4900,
...
Visioneer Onetouch 7700. Updated other scanners.
2006-10-24 20:53:47 +00:00
Henning Geinitz
2df19bcd0b
Added Support for Genius Colorpage SF600.
2006-10-03 21:24:39 +00:00
Henning Geinitz
a0b7aed86d
Added EDT BizCardReader 900C. Moved Genius ColorPage-SF600 to gt68xx.desc. Minor
...
updates.
2006-10-03 21:19:31 +00:00
m. allan noah
2eb55005c6
update to v1.0.43
2006-09-19 12:04:54 +00:00
Henning Geinitz
69914baf00
Added several scanners.
2006-09-14 18:14:13 +00:00
m. allan noah
3a78258ac5
update to v1.0.42
2006-09-01 00:31:45 +00:00
m. allan noah
5bbc2fef6c
update to v1.0.41
2006-08-28 23:45:25 +00:00
Wittawat Yamwong
12bade88f5
* Removed Smartbase MP360 (supported by pixma backend)
2006-08-27 12:59:42 +00:00
Wittawat Yamwong
788b7eb0aa
* add MP360,MP530 and MP800R product ID
2006-08-27 12:54:36 +00:00
m. allan noah
e47693e107
updated to v 1.0.40
2006-08-27 00:49:43 +00:00
Karl Heinz Kremer
0da1bfb49a
Added V700/V750 scanner information
2006-08-23 21:45:51 +00:00
Jon Chambers
5b5b49783f
updated driver info
2006-08-12 12:59:40 +00:00
m. allan noah
4d357d0fa1
updated to backend v1.0.39
2006-07-18 00:08:10 +00:00
m. allan noah
6a453bd191
update to backend v1.0.38
2006-07-15 15:15:52 +00:00
m. allan noah
8b9df6bcbf
update to backend v1.0.37
2006-07-15 01:17:33 +00:00
m. allan noah
05aa6cc323
update to v1.0.36
2006-07-06 23:47:13 +00:00
m. allan noah
cdbe31d245
update to backend v1.0.35
2006-07-05 22:46:42 +00:00
m. allan noah
f9927937af
update fujitsu backend to v 1.0.34
2006-07-05 00:42:05 +00:00
Wittawat Yamwong
4e7271defb
Updated status of MP760 and MP780.
2006-07-01 12:21:22 +00:00
m. allan noah
b998ccced7
add S500 usb id and status.
2006-06-27 18:22:00 +00:00
m. allan noah
b4d76b6923
update to backend v 1.0.33, add fi-5900 usb id, print sane version during
...
sane_init.
2006-06-24 17:48:53 +00:00
Henning Geinitz
1bf3a5be5f
Added Xerox WorkCentre PE120i.
2006-06-22 18:45:28 +00:00
Henning Geinitz
1cb470ae02
Fixed USB id of CX6600 (patch from Olaf Meeuwissen <olaf.meeuwissen@avasys.jp>).
2006-06-22 18:37:52 +00:00
m. allan noah
f61d6d2b80
update backend to v1.0.32, just adds a usb id.
2006-06-14 17:46:40 +00:00
m. allan noah
fe0a606b98
update fujitsu backend to v 1.0.31. minor changes
2006-06-13 16:10:39 +00:00
Jochen Eisinger
0b44f2adc4
2006-06-12 Jochen Eisinger <jochen@penguin-breeder.org>
...
* doc/descriptions/mustek_pp.desc: Added Micromaxx MM-0851
2006-06-12 16:27:05 +00:00
Jochen Eisinger
30e10da51b
2006-06-12 Jochen Eisinger <jochen@penguin-breeder.org>
...
* doc/descriptions/mustek_pp.desc: Added Micromaxx MM-0851
2006-06-12 16:24:18 +00:00
Henning Geinitz
a110271f46
Added Canon 9950. Removed Epson 4490 (supported by epkowa). Removed Nikon
...
scanners (supported by coolscan2 backend). Updated PLANon DocuPen R700.
2006-06-11 21:46:47 +00:00
Henning Geinitz
ee5542ebc1
Added (minimal) support for Nikon LS 50 ED, Coolscan V ED and (probably) Super
...
Coolscan LS-5000 ED (patch from Giuseppe Sacco
<giuseppe@eppesuigoccas.homedns.org>).
2006-06-11 21:35:19 +00:00
Karl Heinz Kremer
3d057d04c6
Applied Henning's patch, Fixed some compiler warnings.
2006-06-11 19:46:09 +00:00
Wittawat Yamwong
f0c5deb436
Removed experimental flag from MP750, MP760 and MP780.
2006-06-10 10:50:43 +00:00
Wittawat Yamwong
e6bf801f40
Updated status of MP750.
2006-06-08 17:50:41 +00:00
m. allan noah
c62006fd47
update to v1.0.30
2006-06-07 02:42:27 +00:00
Rene Rebe
91255bd85a
the last remaining Avision usbid without tailing zeros, sorry
2006-06-06 11:35:12 +00:00
Rene Rebe
ead7bf6036
hopefully fixed the remaining Avision usbids to make the scripts happy
2006-06-06 11:32:00 +00:00
Rene Rebe
66fe987c4d
Avision backend update (Build 182 -> 201), the ChaneLog has the details
2006-06-06 11:24:18 +00:00
Gerard Klaver
67ab594a6c
first release file for stv680 backend
2006-06-05 18:19:56 +00:00
m. allan noah
8f80793464
updated to v 1.0.29, the 'ram-eater' release
2006-06-04 03:59:48 +00:00
Wittawat Yamwong
4284b35d78
Updated device status.
2006-06-03 00:39:09 +00:00
m. allan noah
022ae0f5ab
update to v 1.0.28
2006-06-01 23:43:04 +00:00
m. allan noah
3adfe84214
update to fujitsu backend v 1.0.27
2006-05-31 03:01:06 +00:00
Jon Chambers
07f13bd712
added dell1600n_net description
2006-05-29 16:11:38 +00:00
Gerhard Jaeger
c41669198f
Added support for CIS-based sheetfed scanners, namely
...
TravelScan662.
Added support for saving calibration data for CIS
devices - should speedup CanoScan devices.
2006-05-28 11:25:53 +00:00
Wittawat Yamwong
258b7934af
Added pixma backend.
...
Moved doc/descriptions-external/pixma.desc to doc/descriptions
2006-05-26 07:49:24 +00:00
m. allan noah
ad3b5f989d
fujitsu: fix bug, update desc with comment and version number
2006-05-24 01:50:40 +00:00
m. allan noah
06f66d476c
add usb id
2006-05-22 02:52:52 +00:00
Henning Geinitz
6e29f278bd
Added support for Plustek OpticPro S24 (some models). Added .conf entry for
...
Plustek OpticPro S12.
2006-05-21 16:50:30 +00:00
Henning Geinitz
a07ee8c7ff
Updated comment for Plustek OpticPro S24.
2006-05-21 16:47:08 +00:00
Henning Geinitz
cc0439aa4f
Removed models that are now in pixma.desc.
2006-05-21 15:30:36 +00:00
m. allan noah
11be734353
minor updates for status/usbids
2006-05-18 17:26:06 +00:00
m. allan noah
8098c5a432
minor updates to usbids and comments
2006-05-18 14:42:39 +00:00
m. allan noah
97b8366fc3
hmm- status not valid for backend, only model
2006-05-12 20:21:47 +00:00
m. allan noah
4d773bc57b
updated desc file, more usb ids, many more models, better urls, etc
2006-05-12 20:00:11 +00:00
Henning Geinitz
d0e8603f62
Added Epson Stylus CX-5800 and some PLANon scanners.
2006-05-10 19:38:29 +00:00
Henning Geinitz
b9696cfcd7
X1150 is reported to work.
2006-05-06 07:08:35 +00:00
Henning Geinitz
5277837ae0
Added Microtek Scanmaker 3880.
2006-04-20 17:23:15 +00:00
Henning Geinitz
92e629e922
Added missing scanners from libsane.usermap.
2006-04-18 15:41:34 +00:00
Henning Geinitz
67941f9032
Added missing devices.
2006-04-18 14:39:16 +00:00
Henning Geinitz
955a75979e
Added USB ids. Splitted some entries which have two different USB ids. Clarified
...
comment about UMAX 3400.
2006-04-18 12:34:01 +00:00
Henning Geinitz
3126bc3135
Used avision-desc.sh to update the .desc file to current SANE CVS avision.c
...
code. Added USB ids.
2006-04-18 12:32:02 +00:00
Henning Geinitz
4301acdbe7
Added most USB vendor and product ids. Minor cleanup.
2006-04-18 12:23:47 +00:00
Henning Geinitz
66dff39d19
Moved scanners supported by the external pixma backend to pixma.desc. Added
...
Canon PIXMA MP730.
2006-04-17 14:53:27 +00:00
Henning Geinitz
709da66159
Make UMAX 2100U (and probably 1600U and 2000U) work. Code from Patrick Lessard
...
<palessar@cgocable.ca>. Updated manual page and .desc file.
2006-04-17 12:46:41 +00:00
Henning Geinitz
828ed95b6e
Added Lexmark X5150.
2006-04-09 22:01:50 +00:00
Henning Geinitz
2f6ae4a1b3
Added links to Patrick Lessard's patch.
2006-04-09 11:57:19 +00:00
Henning Geinitz
87d4a3c10d
Added C-Channel scanners.
2006-04-03 18:36:16 +00:00
Henning Geinitz
1f28f3d134
Added Canon PIXMA760, Tevion MD 90090, Microtek ScanMaker 4600, and Visioneer
...
Onetouch 9320. Removed Canon CanoScan 3200F (now in external backends).
2006-03-29 22:01:57 +00:00
Henning Geinitz
f79d1cf747
Added Iris Iriscan and Xerox Documate 510.
2006-03-24 22:25:50 +00:00
Henning Geinitz
d3cd1c9d6d
Added Microtek ScanMaker 4850 II and Plustek OpticPro ST 64+.
2006-03-16 13:04:46 +00:00
Henning Geinitz
c782ab3921
Added Brother MFC 9600, Canon PIXMA MP450, and Plustek ScanCopy 115.
2006-03-05 14:56:12 +00:00
Henning Geinitz
6b15d3635b
Removed HP ScanJet 8200 (supported by Avision backend). Minor updates.
2006-02-12 13:09:54 +00:00
Henning Geinitz
a946b95e22
Removed Trust Office Scan USB 19200 (now in niash.desc), added Xerox 4800 One
...
Touch.
2006-02-04 17:04:45 +00:00
Ullrich Sigwanz
28346f5111
adding trust office scan 19200
2006-02-04 10:28:51 +00:00
Henning Geinitz
b7f314ad8c
Added Benq 7400UT and Genius Colorpage CS.
2006-01-29 21:37:56 +00:00
Henning Geinitz
7be3113c60
Added Scanshell 800N and Canon Smartbase MP360.
2006-01-22 16:35:43 +00:00
Henning Geinitz
98d5d821a5
Added USB vendor and product ids. Changed status of X1150 and X1170 according to
...
reports on sane-devel.
2006-01-15 18:17:38 +00:00
Henning Geinitz
c7787a23e8
Added Mustek BearPaw 1248 CU.
2006-01-15 18:15:53 +00:00
Henning Geinitz
31a2b3ff35
Added Yakumo Scan50. Minor cleanup.
2006-01-15 18:15:02 +00:00
Henning Geinitz
4370559a08
Added USB vendor and product ids. Minor cleanup.
2006-01-15 18:12:41 +00:00
Oliver Schwartz
b27979a8ee
Added Epson Stylus CX-1500
2006-01-10 19:32:39 +00:00
Henning Geinitz
0b40e2d429
Added interfaces to Panasonic scanners.
2006-01-09 21:59:58 +00:00
Henning Geinitz
34886d6c8c
Added USB id.
2006-01-09 21:59:03 +00:00
Oliver Schwartz
cec8cca5b2
Added USB IDs
2006-01-08 22:49:16 +00:00
Henning Geinitz
5bd238fe0b
Missed one USb id.
2006-01-08 22:12:04 +00:00
Henning Geinitz
7baf54b170
Added USB vendor and product ids. Minor cleanups.
2006-01-08 22:01:51 +00:00
Henning Geinitz
60a4f9e3ed
Added vendor and product ids for all scanners.
2006-01-08 15:59:22 +00:00
Henning Geinitz
68374c3448
Added Xerox 4800.
2006-01-08 12:48:14 +00:00
Henning Geinitz
55455adf47
Added Medion MD 85264 finger print sensor and Trust Office Scan USB 19200.
2006-01-07 16:33:03 +00:00
Henning Geinitz
7b03fc2168
Added option "source" which can be used to simulate an Automatic Document Feeder
...
(ADF). Added copyright header to test.h.
2006-01-02 22:55:44 +00:00
Henning Geinitz
78f4ed984b
Added Visioneer 9450 USB. Updated comments for Plustek S(T)12.
2006-01-02 17:24:58 +00:00
Henning Geinitz
e891ffb8ab
Added Plustek OpticPro S(T)12 (product id 0x040b). Mostly untested. Print warmup
...
message 5 seconds after starting the warm-up.
2006-01-02 16:59:03 +00:00
Oliver Schwartz
9a24efc4ea
Added calibration data for Benq 5150 / 5250, preliminary support for Epson Stylus CX 1500
2006-01-01 22:57:02 +00:00
Henning Geinitz
12d53d9d43
Added/updated several old Acer (Benq) and Agfa parport scanners.
2005-12-29 17:51:01 +00:00
Henning Geinitz
069094b52c
HP Scanjet 3690 uses GL646_HP chipset.
2005-12-28 13:07:53 +00:00
Henning Geinitz
8256fe8b3b
Added external hp3900 backend. Moved (possibly) supported scanners from
...
unsupported.desc.
2005-12-27 13:10:36 +00:00
Henning Geinitz
97ca232626
Added Lexmark X2330.
2005-12-24 12:00:36 +00:00
Henning Geinitz
0f1f4fca58
Changed status of Artec AT6 to "good" as reported in bug #302749 .
2005-12-23 13:10:18 +00:00
Henning Geinitz
a2b1327736
Added Canon Pixma MP500.
2005-12-23 13:05:06 +00:00
Henning Geinitz
5ca80b197e
Removed "NEW!" markers.
2005-12-20 18:01:41 +00:00
Henning Geinitz
07757d4c85
Added hp3500 backend which supports the HP ScanJet 3500 series, including the
...
3500C, 3530C and 3570C (patch from Troy Rollo <sane@troy.rollo.name>) (bug
#302687 ).
2005-12-20 17:55:45 +00:00
Henning Geinitz
df2a8b6180
Fixed dynamic loading on current HP/UX systems (bug #302732 ).
2005-12-20 17:15:39 +00:00
Henning Geinitz
25e5788220
Added Trust Direct WebScan 19200 (reported on sane-devel).
2005-12-18 13:28:27 +00:00
Henning Geinitz
901945fc89
Added link to Lexmark X6170.
2005-12-18 13:16:48 +00:00
Karl Heinz Kremer
463ad7ef64
doc/descriptions/epson.desc: Added a few new scanners based on messages to the sane-devel mailing list.
2005-12-18 01:26:10 +00:00
Henning Geinitz
d73e02a34e
Removed HP 3500, 3530, and 3570 (now in hp3500.desc).
2005-12-10 16:03:16 +00:00
Henning Geinitz
7d332297b6
Silenced non-fatal warnings/error messages. Several fixes for avoiding
...
freezes/timeouts after cancelling a scan. Several fixes for warming up of
lamp. Decreased scan width of Plustek OpticPro 1248U.
2005-12-09 11:55:11 +00:00
Henning Geinitz
c8fb998804
Added Lexmark X6170. Removed Brother MFC 4600 USB.
2005-12-09 11:45:39 +00:00
Henning Geinitz
8ed6601f69
Added .desc file for new external backend for Primax
...
Colorado 2400U.
2005-12-07 19:03:41 +00:00
Henning Geinitz
ade247b0c9
Added Brother MFC-7300c.
2005-12-07 18:42:21 +00:00
Henning Geinitz
f1b29682ac
Changed status of Canon LiDE 50 and 60 to "good". Added comment for untested
...
LiDE 40 to report any success/failure.
2005-12-06 10:50:07 +00:00