Calibration and exposure uses a broader spectrum now. Expsoure
limit is increased to 50 loops. Genius Vivid 4x is reported to
work so the UNTESTED label is removed now. Visioneer 7300 is
reported to work so the UNTESTED label is removed now. Genius
ColorPage Vivid 1200XE: Removed UNTESTED label. Fixed
resolutions. Adjusted margins. Fixed color order. Fixed
linedistance. Adjusted AFE. Mustek ScanExpress 1248 UB: Fixed
margins. Adjusted AFE. Adjusted exposure. Adjusted
gamma. Changed status to "complete". Mustek BearPaw 2400 CU
Plus: Adsusted exposure and AFE parameters. Hopefully stripes
and similar trouble are gone now. Mustek BearPaw 1200 CU:
Increased exposure to avoid vertical lines. Updated manual page.
"unsupported" warning. Added workaround for shared memory compilation problem
on Windows. It's now possible to add a new vendor/product id line to gt68xx.conf
to test yet unsupported scanners without changing the source code.
in color mode now. Made 600 dpi mode for Mustek BearPaw 2400 TA
Plus a bit faster. Changed Mustek ScanExpress A3 linedistance
correction. Added detection of Visioneer Onetouch 7300.
as that resolution doesn't work. Make sure that the lamp of the Mustek A3 USB
gets warmed up. It's a CIS scanner with a lamp. That code is untested. Full scan
starts scanning from the start position of the white strip now. Added detection
for Genius Vivid 1200 EX. Fixed product id of Mustek BearPaw 2448 TA Plus. Other
minor updates.
A3 USB to CCD. Black mark may be still wrong. Minor formatting changes in the
manpage. Decreased ScanExpress A3 USB status to alpha because of CIS/CCD
change.
now. Looks like GT-6816 based scanners return 8 bytes if the firmware is
loaded and 64 bytes if it's not loaded. Changed GT-6816 firmware check to
ignore errors from above change. GT-6816 scanners work with the BSDs now (at
least once). Updated manpage concerning the BSDs.
kernel 2.4.21-pre3 containing the 1-endpoint fix. Fixed A3 USB resolution
setting. Updated A3 USB margins (Pedro Morais <morais@inocam.com>). Added
detection of Genius Colorpage Vivid3x. It's unknown if it works. Updated
.desc file. Don't print calib line warnings by default.
control for CCD scanners. Added flag for SE 2400 USB, added some quirks in
gt68xx_gt6801.c. Fixed gt68xx_gt6801 -> lamp control. Adjusted Plustek 1248U
geometry and afe values. CCD gross calibration changed: start with the default
value from module struct. Is faster now for most cases. Only 2.5 mm of
calibration for GT-6801 scanners. Added "afe" option for gt68xx.conf for
selecting default afe values. Removed AFE and exposure SANE options. Added
documentation for afe option in gt68xx.conf. New version: 1.0-35.
table factor option (SANE_CAP_EMULATED). Setup gamma to 2.0 by default. Fixed
(hopefully) sigpipe when cancelling. No geometry quantization anymore (not
necessary). Plustek 1248U: do linemode for every resolution, fix color
correction. Added comments for every Model member in gt68xx_devices. Added
Plustek UT16B and Genius Vivid3x to .desc. Added implementation for inverted
offset for CCD scanners. Added Mustek ScanExpress 2400 USB. Well, at least
it's detected. Added NEW marker to .desc.
gt68xx_low.c. Used DBG instead of XDBG ing gt68xx_low.c. Minor manpage
fixes. Added man page links to other backends. gt68xx_low.h: Fixed
__FUNCTION__ bug on non-gcc compilers. Added more details about the BSDs in
the manpage. Fixed color order for ScanExpress A3 USB.
translation markers for all options. Added German translation for backend
options. Updated manpage and .desc file concerning scanner status. Added
untested flag for Mustek ScanEpress A3 USB and Lexmark X73.