Oliver Schirrmeister
86a3214291
patch from Ron Cemer <ron@roncemer.com>
...
fixes the broken "ADF empty" detection on the Fujitsu scanners
when connected via USB. It also fixes a sense-request issues,
which were required in order to determine whether the ADF is
empty. It also eliminates some duplicate code blocks.
renamed some functions
2003-03-14 18:21:22 +00:00
Henning Geinitz
7d03b5c4df
Removed fujitsu and ma1509 entries. Updated .desc files and global variables
...
entry.
2003-03-13 17:30:13 +00:00
Henning Geinitz
39a2dd7f0a
Added some Boeder, Brother, HP and Trust scanners.
2003-03-13 17:27:31 +00:00
Henning Geinitz
a84d4a611f
Added Packard Bell Diamond 1200 Plus to .desc and manpage. New flag to avoid
...
running stop_scan before doing a scan. The Windows firmware of the BearPaw
1200 CU Plus doesn't seem to like that.
2003-03-13 17:18:29 +00:00
Oliver Schirrmeister
711bb118b4
displays the offending byte when something is wrong in the
...
window descriptor block.
2003-03-10 12:38:36 +00:00
Eddy De Greef
b743fe4641
Fixed two calibration bugs in mustek_pp_cis.[ch].
2003-03-09 20:33:37 +00:00
Eddy De Greef
61c2a6aa24
Fixed two calibration bugs: one occasionally caused overexposed images
...
at all resolutions; the other one occasionally caused color inbalances
when scanning narrow areas at high resolutions.
2003-03-09 20:32:49 +00:00
Henning Geinitz
f87050d7b0
Removed link to everex (timeout).
2003-03-09 20:05:12 +00:00
Henning Geinitz
646fbd05bc
Wait for the completion of all SCSI commands in sanei_scsi_flush_all_extended
...
(Linux). Without this fix, especially long running commands and command
queuing would cause memory corruption if the buffer was invalid after the
flush command.
2003-03-09 19:22:43 +00:00
Henning Geinitz
8d9c13ed82
Minor debug message updates. Fixed a little bug in sane_control_option (gamma
...
control). Removed the signal blocking again. That only hides the segfault in
sanei_scsi. Check if there are documents in ADF for Paragon 2. Otherwise
return error. Fix some minor issues in reading the config file.
2003-03-07 19:31:26 +00:00
Peter Fales
35391a21a3
doc/descriptions/dc210.desc, doc/descriptions/dc240.desc
2003-03-07 14:16:16 +00:00
Peter Fales
cd8e633206
Update Kodak URLs
2003-03-07 14:12:00 +00:00
Henning Geinitz
0bb508a879
Small requests are done with a response buffer of 8 bytes (instead of 64)
...
now. Looks like GT-6816 based scanners return 8 bytes if the firmware is
loaded and 64 bytes if it's not loaded. Changed GT-6816 firmware check to
ignore errors from above change. GT-6816 scanners work with the BSDs now (at
least once). Updated manpage concerning the BSDs.
2003-03-06 14:27:54 +00:00
Henning Geinitz
6a0dd9cd5e
Added missing option size (avoids crash on network scanning). Patch from Milon
...
Firikis <milonf@hotpop.com>.
2003-03-05 18:04:33 +00:00
Oliver Schirrmeister
f9d7350534
* backend/fujitsu.c, backend/fujitsu.h: renamed some variables
...
* backend/fujitsu.c: gray duplex scanning now works with the 4097D
when disconnect is enabled in the scsi-controller
* doc/descriptions/unsupported.desc: remove fujitsu fi4120C
* doc/descriptions/fujitsu.desc added fi4120C, ScanParter 93GX
2003-03-05 12:56:44 +00:00
Henning Geinitz
a4b5a465fd
Removed Umax AstraSlim (now supported by artec_eplus48u backend).
2003-03-04 23:58:23 +00:00
Henning Geinitz
bf357a6b9a
Changed the example to use /dev/sg0 instead of /dev/sge.
2003-03-04 23:55:47 +00:00
Henning Geinitz
df7d2cda19
Added function sanei_check_value in addition to the existing
...
sanei_constrain_value. It checks if the value of a sane option fits into the
constraint but doesn't try to do any fixing/rounding.
2003-03-04 22:37:39 +00:00
Gerhard Jaeger
ca786b2c28
Bug-fix update for Genius, HP2100c and EPSON Photo devices.
2003-03-03 14:34:20 +00:00
Henning Geinitz
a04ea4b251
Make sure that the firmware for plustek-like scanners is loaded. Didn't work
...
for Genius vivid3xe. Added both Genius scanners to man page. Removed warning
from Genius Vivid3xe.
2003-03-02 22:08:50 +00:00
Michael Herder
6520e41917
*** empty log message ***
2003-03-02 06:55:18 +00:00
Henning Geinitz
f8b385aca1
Updated Microtek scanners. Added Umax AstraSlim SE.
2003-03-01 17:39:57 +00:00
Henning Geinitz
175a070af6
Added Ricoh IS-430.
2003-03-01 17:38:27 +00:00
Ulrich Deiters
bf3546ca14
adjusted backend/canon-sane.c to use the new sanei_constrain_value()
...
made some cosmetic changes to reduce the number of compiler warnings
2003-02-28 09:35:24 +00:00
Henning Geinitz
4558610025
Added Compaq S4 100 and Microtek Scanmaker 4800.
2003-02-27 23:06:09 +00:00
Henning Geinitz
4b00890161
Added Genius Colorpage Vivid3xe. Added request_type and request fields to the
...
command set. Request is 0x01 or 0x04.
2003-02-27 17:31:52 +00:00
Henning Geinitz
6df6af8d0e
Round a word list value to the nearest entry (if necessary). Code was taken
...
from canon backend.
2003-02-26 18:52:55 +00:00
Ulrich Deiters
540656fd72
mentioned the new FB1200S in the man pages
2003-02-26 17:52:40 +00:00
Henning Geinitz
0dcf319756
Added :new token.
2003-02-26 15:34:27 +00:00
Henning Geinitz
113152bbed
Removed hp5400 series (now in hp5400.conf). Added Lexmark, Medion and Primax
...
scanners.
2003-02-26 14:31:38 +00:00
Henning Geinitz
1bbf2101e6
Added Visioneer OneTouch 8600.
2003-02-26 14:29:48 +00:00
Henning Geinitz
ccb0bbe80d
Added description for hp5400 backend. It supports the Hewlett-Packard 5400,
...
5470 and (maybe) 5490 scanners.
2003-02-26 14:25:46 +00:00
Ulrich Deiters
4fe497b559
* modified the Canon SCSI backend (now version 1.12):
...
* backend/canon.c, canon-sane.c, canon.h: Added support for
the FB1200S flatbed scanner.
* backend/canon.c: Made the sense handler generate meaningful
status information for new scanner models (solved the Mandrake
crash problem).
* backend/canon.c, canon-sane.c, canon.h: Moved model-dependent
declarations and decisions to a common location.
* backend/canon-sane.c: Fixed the out-of-memory problem of
xscanimage when doing previews with scanners using hardware
scan resolutions only.
2003-02-26 13:50:00 +00:00
Henning Geinitz
ed9cd94046
Updated French translation (from Yann E. MORIN <yann dot morin dot 1998 at
...
anciens dot enib dot fr>).
2003-02-25 23:01:12 +00:00
Stéphane Voltz
5ed8c99cb7
- changed 'gain' option name to 'brightness'
...
- changed 'highlight' option name to 'contrast'
2003-02-25 07:04:12 +00:00
Henning Geinitz
141a7159d9
Some parts concerning PRJECTS/.desc files are rewritten. Added information
...
about initializing global variables and sizeof (void *) != sizeof (int) (from
Martijn van Oosterhout <kleptog@svana.org>).
2003-02-24 21:16:44 +00:00
Henning Geinitz
b1564e705a
Updated for ma1509.
2003-02-24 21:11:02 +00:00
Henning Geinitz
bb2da8d6c7
Added ma1509.
2003-02-24 21:07:10 +00:00
Henning Geinitz
d452194baa
Removed.
2003-02-24 21:06:31 +00:00
Henning Geinitz
47d5a76da0
Added documentation for ma1509 backend.
2003-02-24 21:05:18 +00:00
Henning Geinitz
747619ae5f
Added new backend ma1509 for Mustek BearPaw 1200F scanners.
2003-02-24 21:04:08 +00:00
Simon Munton
d152930b5e
incremented BUILD in pie.c (missed in last change)
2003-02-23 17:12:51 +00:00
Simon Munton
0423675807
fixed segmentation faults in pie.c when sane_init/sane_exit called more than once
2003-02-23 13:32:52 +00:00
Stéphane Voltz
711f602c76
- reset global vars when needed
...
- fixed a bug when th device name used was ""
2003-02-23 08:54:16 +00:00
Frank Zago
591cd41fa4
Changes.
2003-02-22 19:45:47 +00:00
Frank Zago
d5a3bf7234
Added Mitsubishi to the list of vendors.
2003-02-22 19:45:24 +00:00
Frank Zago
711d1bb348
Added more sane_init/sane_exit tests. Added Fujistu and Relisys to the list of valid vendor names.
2003-02-22 19:41:08 +00:00
Frank Zago
3d92598acd
Added Relisys in the list of vendors. Bumped the revision date.
2003-02-22 18:43:45 +00:00
Henning Geinitz
1a6da620ab
Add ma1509 backend. Add segfault when running sane_init more than
...
once. Removed sanei_usb interface issue.
2003-02-22 17:25:41 +00:00
Henning Geinitz
3cf8377bee
Initialize global variables in sane_init.
2003-02-22 16:54:22 +00:00