Wykres commitów

2681 Commity (28c514bf73ae20f174b55dd8a1756165f17e3d83)

Autor SHA1 Wiadomość Data
Henning Geinitz 5c4b3d9a0e Mustek BearPaw 2448 TA Pro has status "good" now. 2005-08-31 20:45:53 +00:00
Henning Geinitz e401121ef1 Removed Mustek 1800 A3 Pro (this is actually a P3600 A3 Pro). 2005-08-31 20:44:47 +00:00
Henning Geinitz e80ac97c60 New external Backend for Mustek BearPaw 2448 TA Pro. 2005-08-30 20:22:27 +00:00
Henning Geinitz 1c9f419660 Removed Mustek BearPaw 2448 TA Pro (now supported by external Mustek USB2
backend). Added comments about that backend to some other scanners that may be
supported later.
2005-08-30 20:21:26 +00:00
Henning Geinitz e51df58fc8 Canon LiDE 60 is GL841 based. 2005-08-29 16:43:43 +00:00
Henning Geinitz 8f789e594c Changed status of Canon 636u too "good". 2005-08-28 14:37:33 +00:00
Henning Geinitz f191ed670d Brother MFC-5440CN is reported to work (bug #302105). 2005-08-27 11:06:57 +00:00
Stéphane Voltz 8c463cfb76 - added EPP support for UMAX Astra 610P 2005-08-24 05:35:06 +00:00
Henning Geinitz 492e322adf Added Canon LiDE 60. Reflecta Digitdia 3600 is not GL841-based. 2005-08-23 16:30:28 +00:00
Stéphane Voltz f9f48fafa4 - Added rts8858c (used by lexmark X1100 series) detection 2005-08-22 18:59:26 +00:00
Henning Geinitz d202ddbe93 Mention problems with library names. 2005-08-22 17:18:26 +00:00
Henning Geinitz 821ca4d53c Added some Genius scanners. Fixed Visioneer Onetouch 7300 USB. Added Plustek
OpticSlim 2400.
2005-08-22 15:48:48 +00:00
Gerhard Jaeger e65d96c5b0 * doc/plustek/Plustek-USB.changes: Update.
* backend/plustek.c: Bumped build number.
* backend/plustek-usb.c backend/plustek-usbscan.c: Fixed problem,
  when trying to scan at resolutions beyond the optical one
  (sensor stops too early).
* tools/hotplug/libsane.usermap: Added USB ID for LiDE25.
2005-08-22 07:29:14 +00:00
Henning Geinitz dc9efdd920 Marked microtek2 backend as unsupported. Changed link to point to old website
directly. Listed Microtek ScanMaker 9800XL as supported (bug #301515).
2005-08-21 14:41:54 +00:00
Mattias Ellert dcec1b5385 Updated from libtool 1.5.18. 2005-08-21 08:12:42 +00:00
Henning Geinitz 93d43e0be8 Increased number limit of scanners that can work with this backend to 50. Added
support for Genius ColorPage Vivid 1200 X (untested).
2005-08-20 17:54:34 +00:00
Henning Geinitz 46be471fd0 Disabled link to backend homepage which doesn't seem to contain anything
sane-related.
2005-08-19 15:59:01 +00:00
Henning Geinitz 3c38ba02f4 Enabled GT68XX_FLAG_NO_STOP for Mustek BearPaw 2400 CU Plus. Some of these
scanners don't seem to like that command.
2005-08-19 15:54:31 +00:00
Henning Geinitz e50187fb8f Fixed check for usbcalls.h on OS/2 (patch from Paul Smedley <paul@smedley.info>). 2005-08-19 15:26:50 +00:00
Gerhard Jaeger 269fd05fb2 * doc/plustek/Plustek-USB.changes: Update.
* backend/plustek-usb.h backend/plustek-usbdevs.c: Removed obsolete
  _WAF_BLACKFINE. LiDE20 does not seem to have a reliable black
  calibration area, so the devices now will switch off the lamp
  for dark calibration.
* backend/plustek-usbcal.c backend/plustek-usbscan.c: Cleanup.
* backend/plustek-usbshading.c: Fixed line statistics and added
  calibration data output.
* backend/plustek.c: Bumped build number.
2005-08-19 11:56:52 +00:00
Henning Geinitz b19e6c5262 Fixed the problem concerning scanning on *BSD. Scanning only worked once (bug
#300597). Fixed compilation warnings.
2005-08-18 19:26:09 +00:00
Henning Geinitz 9f9339fd92 Min. libusb version is 0.1.8. 2005-08-17 18:01:37 +00:00
Julien BLACHE 94ad270193 Added USB IDs for the sm3600-supported scanners. If you know the exact model name corresponding to the above IDs, please mail sane-devel:
0x05da/0x40b3, 0x05da/0x40b8, 0x05da/0x40ca, 0x05da/0x40dd, 0x05da/0x40ff
2005-08-17 16:36:49 +00:00
Henning Geinitz 621dc84b90 Added check for Toshiba M011 chips as used in Microtek ScanMaker 3600, 3700, and
3750.
2005-08-16 20:28:46 +00:00
Oliver Schwartz 0f98b4adfe Removed C++-style comment 2005-08-16 20:15:10 +00:00
Henning Geinitz a2f1183de1 Removed direct dependence of sm3600 on libusb. Used sanei_usb instead. Based on
patch from Francois Revol <revol@free.fr>.  Updated documentation
accordingly. Fixed compilation warnings.
2005-08-16 19:50:34 +00:00
Henning Geinitz ee11f5abcf Added check for combination of a PowerVision PV8630 (USB->parport bridge) and
National Semiconductor LM9830 as used in the HP 4200. Fixed compilation warning.
2005-08-16 18:23:42 +00:00
Henning Geinitz 53fe9ae549 Don't print anything else but the found messages in "-q" mode. 2005-08-16 18:19:41 +00:00
Oliver Schwartz 159782bd7f Make compileable again 2005-08-16 17:19:20 +00:00
Henning Geinitz 921f7d7cbc Added Canon PIXMA MP780 and Lexmark P6250. 2005-08-16 09:32:21 +00:00
Oliver Schwartz 7f9b7c4646 Added temporary debug code for 2480/2580 distinction 2005-08-15 18:56:55 +00:00
Oliver Schwartz 59fc80c118 Added support for Epson 3490/3590 (thanks to Matt Judge) 2005-08-15 18:06:38 +00:00
Gerhard Jaeger a4a88fccbf * doc/plustek/Plustek-USB.changes: Update.
* doc/descriptions/plustek.desc: Updated version number.
* backend/plustek.h. backend/plustek-usb.h backend/plustek-usbcalfile.c
  backend/plustek-usbimg.c backend/plustek-usbmap.c
  backend/plustek-usbdevs.c backend/plustek-usbscan.c: Cleanup.
* backend/plustek.c: Bumped version and build number.
  Activated IPC between reader-process and parent.
* backend/plustek-usbio.c: usbio_DetectLM983x() now returns error if
  register could not be red, usbio_ResetLM983x() checks for reg7
  value before writing.
* backend/plustek-usbhw.c: Added button support for Plustek/Genius
  devices. Changed behaviour of usb_IsScannerReady().
  Added special misc I/O setup for CIS devices (usb_ResetRegisters).
* backend/plustek-usb.c: Minor fix for startup reset.
  Removed unnecessary calls to usbio_ResetLM983x().
* backend/plustek-usbshading.c: Readded kCIS670 to add 5% extra to
  LiDE20 fine calibration.
* backend/plustek-usbcal.c: Tried to use the settings from SANE-1.0.13.
  Added _TWEAK_GAIN to allow increasing GAIN during lamp coarse
  calibration. Added call to speedtest function.
2005-08-15 15:02:22 +00:00
Henning Geinitz 3ae9b03454 Don't exit with error when trying to set inactive options. This especially
happens in connection with geometry options and the v4l backend (bugs #300321,
#301977).
2005-08-14 14:51:06 +00:00
Henning Geinitz 46cfa92d35 Enabled backtracking by default. This is slower but avois bumping the scan head
at the end of the scan area and also missing parts of the scanned
image. Increased safety margin for backtracking. This fixes the "garbled image"
bug. Set default gamma value to 2. Manpage update. Status set to "basic".
2005-08-14 12:59:32 +00:00
Henning Geinitz dccf9e2fa2 Added Changelog-1.0.16 to DISTFILES. 2005-08-14 08:22:32 +00:00
Henning Geinitz 2ce6d33e26 Moved CPPFLAGS definition down to avoid problems with libtool tests for -fPIC. 2005-08-13 16:02:50 +00:00
Henning Geinitz 78a02e266b Removed (backend is now included). 2005-08-13 15:32:12 +00:00
Henning Geinitz 3c5ea794ba Added hp4200 backend. Code from Julien BLACHE's sane-backends-extras debian
package, based on Frank Zago's patches based on Adrian Perez Jorge's code. Fixed
compilation warnings. Fixed bug when no sane device was given. Code indented by
indent -gnu. Added man page.
2005-08-13 15:30:02 +00:00
Henning Geinitz 6953fd4e2c Removed ":new". 2005-08-13 15:18:48 +00:00
Gerhard Jaeger 3a4c35c470 * backend/plustek_pp.c: Bumped build number.
* backend/plustek_pp-genericio.c: Fixed bug, that causes ASIC96003/1
  based devices to move their sensors too fast in lineart mode at
  200 and 300dpi.
* doc/plustek/Plustek-PARPORT.changes: Update.
2005-08-10 20:41:09 +00:00
Henning Geinitz 784791758e Added Hewlett-Packard Scanjet 4370. 2005-08-09 17:16:32 +00:00
Henning Geinitz 4b2d240870 Minor fixes for usbcalls interface (patch from Paul Smedley <paul@smedley.info>). 2005-08-09 16:28:38 +00:00
Gerhard Jaeger 4877fb0d98 * acinclude.m4 configure: Locking feature will be disabled on OS/2
per default (according to Paul Smedley <paul@smedley.info>).
* doc/plustek/Plustek-USB.changes: Update.
* backend/plustek.c: Bumped build number.
* doc/plustek/Plustek-USB.txt doc/descriptions/plustek.desc
  doc/sane-plustek.man backend/plustek-usb.c backend/plustek-usbdevs.c:
  Added support for CanoScan LiDE25.
2005-08-08 07:43:14 +00:00
Henning Geinitz b29ea31da2 Fixed some compilation warnings. 2005-08-07 15:53:03 +00:00
Henning Geinitz 2d224c4a75 Added support for usb functionality on OS/2 using the usbcalls interface (patch
from Paul Smedley <paul@smedley.info>).
2005-08-07 14:26:33 +00:00
Henning Geinitz 5cd850ee6a Updated from libtool 1.5.18. 2005-08-07 13:03:32 +00:00
Oliver Schwartz f283eedc6b Corrected date in ChangeLog 2005-08-07 12:38:33 +00:00
Oliver Schwartz 417ef8eac5 Use first known device if no device is specified 2005-08-07 12:37:29 +00:00
Henning Geinitz 1ee59e30eb Typo fix. 2005-08-07 12:32:37 +00:00
Henning Geinitz 92b8f5e33f Updated version. Enabled compilation warnings. 2005-08-07 12:08:07 +00:00
Henning Geinitz 26a01ae380 ****** Release of sane-backends 1.0.16. End of code freeze ****** 2005-08-07 10:05:21 +00:00
Henning Geinitz 34a5bc2fb8 New version 1.0.16. 2005-08-07 10:04:34 +00:00
Stéphane Voltz 9857b4cf6c - fixed endianess issue in genesys backend when creating
slope table
2005-08-05 12:18:35 +00:00
Henning Geinitz bf897c3502 Updated Danish translation (from Mogens Jaeger <mogensjaeger@get2net.dk). 2005-08-02 17:21:34 +00:00
Mattias Ellert 3758711bdb Update Swedish translation. 2005-08-02 15:09:21 +00:00
Eddy De Greef 2fd060fe23 Updated URL for additional CIS driver info. 2005-08-01 19:14:50 +00:00
Henning Geinitz 5c255ba9e0 Updated. 2005-07-31 15:44:13 +00:00
Henning Geinitz 292d5db30a ---- CODE FREEZE FOR SANE 1.0.16 --- 2005-07-31 15:38:28 +00:00
Henning Geinitz a1a5e6de83 Disabled compilation warnings. 2005-07-31 15:37:53 +00:00
Karl Heinz Kremer 4c4a945d1b Applied Olaf Meuwissen's patch to add new device IDs. 2005-07-30 16:52:28 +00:00
Henning Geinitz 4fcd19f065 Avoid error messages in locking test. Make sure that io/cam/cam.h header file
will be detected correctly.
2005-07-30 16:39:00 +00:00
Henning Geinitz 443cfa28bb libsane and documentation is installed correctly again. 2005-07-30 14:15:50 +00:00
Henning Geinitz faf4c8c57e Added Xerox Workcentre 470cx. Added link for Canon DR-2080C. 2005-07-30 13:42:46 +00:00
Gerard Klaver acd978ec7e Update teco2.c .h sane-teco2.man teco2.desc teco2.txt 2005-07-29 20:44:12 +00:00
Julien BLACHE 51cc4e0797 Added various Epson IDs from Olaf Meeuwissen; reodered some misplaced Epson entries. 2005-07-29 10:15:00 +00:00
Julien BLACHE 051d5c0d3a Added Visioneer OneTouch 7300 (0x0444,0x0211), from Derek J Frye. 2005-07-29 10:03:50 +00:00
Gerhard Jaeger ea61868394 * doc/descriptions-external/epkowa.desc: Updated according to
the info provided by  Olaf Meeuwissen <olaf.meeuwissen@avasys.jp>
2005-07-25 09:12:30 +00:00
Henning Geinitz 9c81b97d4a Added unsupported scanners from hp_rts88xx.desc. Removed HP ScanJet 3770 (now in
hp3770 backend). Added Lexmark X75 PrinTrio.
2005-07-24 21:01:52 +00:00
Henning Geinitz e137eecca5 Added external hp3770 and hp8200 backends. 2005-07-24 20:59:21 +00:00
Henning Geinitz cd7606938a Moved unsupported devices to unsupported.desc. 2005-07-24 20:57:45 +00:00
Henning Geinitz b5089cfd10 Brother DCP 7025 is reported to work (bug #301960). 2005-07-24 20:56:37 +00:00
Giuseppe Sacco 10ab7e64db italian translation update 2005-07-22 09:10:41 +00:00
Julien BLACHE 06972e5d57 Added HP ScanJet 7400C (0x03f0, 0x0801). 2005-07-22 07:25:25 +00:00
Henning Geinitz aaf3c69627 Testing commit messages. 2005-07-21 18:02:41 +00:00
Henning Geinitz 67eb059c49 Testing commit mails. 2005-07-21 17:55:50 +00:00
Henning Geinitz e74185c76b Testing commit messages. 2005-07-21 17:50:13 +00:00
Gerhard Jaeger 547c0bb0a7 * doc/plustek/Plustek-USB.changes: Update.
* backend/plustek.c: Bumped build number.
* backend/plustek-usbcal.c: Fixed lampsettings for CIS devices.
2005-07-21 10:01:18 +00:00
Oliver Schwartz 74190c064c Changed TPO scanning area for 2480/2580, reenabled 2400 DPI for 2480/2580 2005-07-20 21:37:29 +00:00
Oliver Schwartz 260f7d83eb ZETA changes for SnapScan backend 2005-07-18 17:37:37 +00:00
Henning Geinitz 1276d174e7 ---- FEATURE FREEZE FOR SANE 1.0.16 --- 2005-07-17 18:32:44 +00:00
Henning Geinitz 2342c2c6f2 Updated. 2005-07-17 18:31:43 +00:00
Henning Geinitz 00e9b16d58 Removed "const" to make gcc on OS/2 happy. 2005-07-17 16:18:34 +00:00
Henning Geinitz 9cf32060ac Make sure that all the necessary files will be in the distribution .tar.gz file. 2005-07-17 12:27:59 +00:00
Henning Geinitz 6c3427c52d Changes to support SANE on ZETA. Not all
patches have been applied yet, but it's a start. The backends
	  are not installed as shared libs but as add-ons, which are shared libs
	  but in a specific folder in [/system|~]/config/add-ons/ named SANE/.
	  The install target has been changed to account for this,
	  Some files don't exist in BeOS/ZETA (ipc.h, ...).
	  Bbackend function names get a prefix, I suppose to avoid namespace clashes.
	  Though we do have a libdl to implement dl_open, the native way is prefered.
	  Added a --with-docdir= configure arg.
	  BeOS has a broken get[name|addr]info() from bind. This is fixed in ZETA R1.
	  libtool needs -no-undefined. Various VPATH fixes.
	  Check for <be/drivers/USB_scanner.h>, but not used yet.
	  No S_IFSOCK (sockets are fds to /dev/net/api). Stub pio code, untested.
	  Patch from Francois Revol <revol@free.fr>.
2005-07-15 21:59:25 +00:00
Henning Geinitz 2dd4b1822c Fixed comment (we still use 30 seconds USB timeout by default). 2005-07-15 18:16:35 +00:00
Henning Geinitz e479c32503 Better 4->8 bit depth expansion algorithm (from Mattias Ellert
<mattias.ellert@tsl.uu.se>).
2005-07-15 18:12:49 +00:00
Oliver Schwartz 74ff64ae24 Updated descriptions for Epson 1670, 2480 and 2580 2005-07-15 17:43:39 +00:00
Rene Rebe e5a5f45497 Updated the Avision backend with the latest off-site maintained version:
fixed segmentation faults for some modes, many many new devices, two
different duplex modes are supported, vast speedup of multi page batch scans,
buttons as well a 7-segment LED readout and some quirks for old scanners not
filling all fields
2005-07-15 09:12:27 +00:00
Rene Rebe e5193fdcae Added support to set the USB timeout. 2005-07-15 09:02:02 +00:00
Henning Geinitz 38cc925c4b Changed resolution from 75 to 100 dpi and changed 16 bit/color to 12 based on a
user report for the Visioneer OneTouch 7300. Updated .desc. Moved check for
stable lamp to its own function. Mustek ScanExpress A3 USB: Use CIS
calibration. Use lamp warmup. Fixed CCD on GT6801 scanning (color scanning was
broken due to a change in motormode_2.
2005-07-10 20:58:58 +00:00
Henning Geinitz 56e3295552 Make sure that getopt is not built on OS/2 (from Franz Bakan <fbakan@gmx.net>). 2005-07-09 13:19:51 +00:00
Henning Geinitz 1cfaf7a3ce Updated Danish translation (from Mogens Jaeger <mogensjaeger@get2net.dk>). Made
sure that no errors occur because xgettext/xmsgfmt think that "%" is a C format
string. Regenerated all po files.
2005-07-09 12:58:20 +00:00
Frank Zago e3aceaf492 *** empty log message *** 2005-07-07 11:57:27 +00:00
Gerhard Jaeger ae92358fed * doc/plustek/Plustek-USB.changes: Update.
* backend/plustek.c: Fixed scanarea calculation.
* backend/plustek-usbshading.c: Fixed fine-white calibration.
2005-07-07 09:59:26 +00:00
Gerhard Jaeger 5b97232b43 * doc/descriptions-external/epkowa.desc: Updated according to
the info provided by  Olaf Meeuwissen <olaf.meeuwissen@avasys.jp>
2005-07-05 06:46:14 +00:00
Gerhard Jaeger 0a91e0b533 * backend/plustek.[ch] backend/plustek-usbscan.c
backend/plustek-usbshading.c backend/plustek-usbdevs.c
  backend/plustek-usbdevs.c backend/plustek-usbimg.c
  backend/plustek-usbmap.c backend/plustek-usbhw.c
  backend/plustek-usbcal.c backend/plustek-usb.[ch]:
  Added button support, did some cleanup, added IPC between
  reader- and parent-process.
2005-07-04 09:55:01 +00:00
Ulrich Deiters a97d0bf43c inserted definition for SSIZE_MAX 2005-07-04 07:01:53 +00:00
Henning Geinitz 161a58ace0 Updated for sane-backends 1.0.16. 2005-07-03 16:12:10 +00:00
Henning Geinitz 3db60263e8 Typo/formatting fixes. 2005-07-03 13:58:21 +00:00
Henning Geinitz 9932061d41 Removed. Scanners have been moved to doc/descriptions/genesys.desc and
doc/descriptions/unsupported.desc.
2005-07-03 13:50:45 +00:00
Henning Geinitz 74cd84acb5 Added links to scanners with GL646 and GL841 chipsets. Moved all unsupported
scanners from doc/descriptions-external/genesys.desc to unsupported.desc. Minor
fixes for other scanners.
2005-07-03 13:46:52 +00:00
Henning Geinitz cb0ed1be00 Used "Medion/Lifetec/Tevion/Cytron" as manufacturer as in the other
backends. Used "ScanJet 2300C" as model name as in other backends.
2005-07-03 13:40:08 +00:00
Henning Geinitz e9f761d067 Don't check the result of usb_find_busses(). Based on patch from Julien BLACHE
<jb@jblache.org>.
2005-07-03 13:35:48 +00:00
Ulrich Deiters 20aff8e022 restored actual version of the Canon-SCSI backend 2005-07-01 19:21:55 +00:00
Stéphane Voltz 8f102afe79 - fixed missing modifications for genesys backend inclusion 2005-06-30 19:46:06 +00:00
Gerhard Jaeger 68a968ecd3 * tools/RenSaneDlls.cmd backend/dll.c: Fixed OS/2 restriction for
dlopening DLLs on OS/2, as it only works for 7.3 filenames for
  some reason (patches by Franz Bakan <fbakan@gmx.net>
2005-06-30 08:19:06 +00:00
Gerhard Jaeger 38e6ad0adb * backend/plustek.c: Fixed "double free" problem in sane_exit.
* doc/plustek/Plustek-USB.changes: Update.
2005-06-27 07:09:15 +00:00
Mattias Ellert a21fe44c4f sane-desc needs $(LIBLIB) 2005-06-26 09:56:24 +00:00
Henning Geinitz 67b85ddb0d Added "Ethernet" to list of possible interfaces. 2005-06-19 16:08:34 +00:00
Henning Geinitz 8cd6e6533f Added several models, updated others. 2005-06-19 16:04:20 +00:00
Henning Geinitz dbbc9e7820 Removed misleading comment. 2005-06-19 15:59:52 +00:00
Henning Geinitz 61409cb5bd Removed Samsung SCX-4216F (supported by samsung backend). Dell 1600n has also
network connection.
2005-06-19 15:56:23 +00:00
Henning Geinitz d4b441310f Added Canon CanoScan LiDE 500F. 2005-06-12 14:57:46 +00:00
Henning Geinitz 7dda4a0306 Fixed comments. 2005-06-04 13:45:26 +00:00
Henning Geinitz 04e085c532 New. Listed scanners supported by the new external brother2 backend. 2005-06-04 13:43:03 +00:00
Henning Geinitz 6de5708e4f Added Genius ColorPage-SF600. 2005-06-04 13:33:13 +00:00
Karl Heinz Kremer a245023c10 Added CX-4600 to desc file. 2005-05-31 01:14:55 +00:00
Henning Geinitz 6fd1ee367e Start exposure with the settings from the scanner entry. CIS
Calibration and exposure uses a broader spectrum now. Expsoure
	  limit is increased to 50 loops. Genius Vivid 4x is reported to
	  work so the UNTESTED label is removed now. Visioneer 7300 is
	  reported to work so the UNTESTED label is removed now. Genius
	  ColorPage Vivid 1200XE: Removed UNTESTED label. Fixed
	  resolutions. Adjusted margins. Fixed color order. Fixed
	  linedistance. Adjusted AFE. Mustek ScanExpress 1248 UB: Fixed
	  margins. Adjusted AFE. Adjusted exposure. Adjusted
	  gamma. Changed status to "complete". Mustek BearPaw 2400 CU
	  Plus: Adsusted exposure and AFE parameters. Hopefully stripes
	  and similar trouble are gone now. Mustek BearPaw 1200 CU:
	  Increased exposure to avoid vertical lines. Updated manual page.
2005-05-29 19:58:56 +00:00
Henning Geinitz ceaa2ddade Updated, mostly concerning kernel scanner driver (deprecated). Minor fixes. 2005-05-29 19:55:15 +00:00
Henning Geinitz 95be6202fa Status of Samsung SCX-4100 is "good" asit's reported to work. 2005-05-29 19:52:39 +00:00
Henning Geinitz 350c73aba3 Fixed missing link for Genius ColorPage-Slim 1200 USB2. 2005-05-28 18:56:25 +00:00
Henning Geinitz e75fa70160 Added Avision DS310F. Added link for the UMAX Astra 4000. 2005-05-28 18:42:07 +00:00
Henning Geinitz 03e378e10b Mention RPC codes explicitely and explain what request and reply means. based on
patch from Johannes Berg <johannes@sipsolutions.net>.
2005-05-26 14:28:01 +00:00
Henning Geinitz c63843df35 Mention RPC codes explicitely and explain what request and reply means. based on
patch from Johannes Berg <johannes@sipsolutions.net>.
2005-05-26 09:30:47 +00:00
Jochen Eisinger 66ff43083a 2005-05-25 Jochen Eisinger <jochen@penguin-breeder.org>
* doc/descriptions/mustek_pp.desc: added scanner
2005-05-25 13:24:03 +00:00
Julien BLACHE 2917422aa2 doc/sane-find-scanner.man, doc/gamma4scanimage.man: spelling fixes from A Costa. 2005-05-23 16:44:44 +00:00
Henning Geinitz ebd956bcae Changed status of Medion MD 6471 to "basic". Removed comment about not-existing
backend.
2005-05-22 13:41:49 +00:00
Henning Geinitz cfb5d0856a Added Konica Minolta Dimage 5400 2. Fixed bus type for Mustek 800 II EP. 2005-05-22 13:38:34 +00:00
Oliver Schwartz 649853f7e1 Disabled 2400 DPI for Epson 2480 2005-05-22 11:50:24 +00:00
Henning Geinitz 1b1eb09205 Regenerated translation files. Updated German translation. 2005-05-20 17:31:07 +00:00
Henning Geinitz 7d0d083b8d Mustek BearPaw 1200 CU Plus model 0x21b works now. Fixed firmware and offset
settings. Calibration is not completely ok yet, however.  Code cleanup for
setup_scan (only one function for all chipsets).  Simplified line mode/pixel
mode setting Updated TODO.  Mustek BearPaw 2448 TA Plus is now only "basic". Too
much trouble for "good".  Removed option "fast preview". By default for preview
mode 8 bits/pixel are used.  Fixed indentation.  Full scan really scans from y=0
on gt6816 scanners now.
2005-05-20 17:21:56 +00:00
Henning Geinitz e659b95cc0 Added Kodak i30 and Minolta Dual Scan IV. Updated link to Konica Minolta website. 2005-05-16 13:06:05 +00:00
Henning Geinitz 31b676a0f5 Minor updates and line-wrap fixes. 2005-05-16 13:03:18 +00:00
Frank Zago 6e2052d795 *** empty log message *** 2005-05-15 19:38:56 +00:00
Julien BLACHE e93887d425 libsane.usermap: Added Epson Stylus RX620 (04b8/0811). From Mike Talbot. 2005-05-13 11:00:26 +00:00
Gerhard Jaeger c411be9bd6 * backend/plustek-pp_misc.c: Applied patch (see bug #301605).
* doc/plustek/Plustek-PARPORT.changes: Update.
* backend/plustek-pp.c: Bumped build number.
2005-05-11 14:46:39 +00:00
Gerhard Jaeger b13a55e34c * sanei/sanei_access.c: Added PATH_MAX, in case it's
not defined by any header (i.e. OS/2).
2005-05-10 06:51:57 +00:00
Mattias Ellert 6219f5471c Readme update 2005-05-07 19:08:56 +00:00
Henning Geinitz ea9ad9a396 Plustek OpticSlim 2400: Fixed list of resolutions. That fixed the
preview. Removed "untested" warning. Adjusted scan area.  Updated gt68xx.TODO.
Find firmwares independent of capitalization (bug #301580).
2005-05-07 17:16:30 +00:00
Julien BLACHE 155790c61d libsane.usermap: Added Microtek ScanMaker 3700 (05da/40cb). From Ian Beckwith. 2005-05-07 09:18:09 +00:00
Gerard Klaver c33139cc82 - indent -gnu
- free (devlist) added so memory allocated by sane_get_devices() will be released (bugreport 300128)
- added more DEBUG lines and some small fixes.
2005-05-06 21:12:21 +00:00
Henning Geinitz b3669f8d6e Added options to set the time after which the lamp of the A3 Pro is shut off
and to shut it off immediately.
2005-05-05 17:28:38 +00:00
Henning Geinitz 2cba59f874 Added Dell 922. 2005-05-05 15:53:22 +00:00
Peter Fales 88df3af0bb When no port is specified in the gphoto2.conf config file, an attempt
was being made to strdup() a bad pointer.
2005-05-05 03:52:03 +00:00
Henning Geinitz 486e6b24a9 Fixed link. 2005-04-29 18:22:11 +00:00
Henning Geinitz 3d75c6a2bd Added ScanPartner 600C (bug #301528). 2005-04-29 17:22:43 +00:00
Julien BLACHE 390e9b4884 backend/v4l.c: duplicate capability.name in attach() so that each device is listed with its actual name, not with the name of the last discovered device. Reported by Andreas Hartmann. 2005-04-28 21:18:41 +00:00
Mattias Ellert 23b39a25f1 Missing braces 2005-04-28 12:49:01 +00:00
Gerhard Jaeger 3f893c5e03 * doc/descriptions/plustek.desc: Added UMAX Astranet ia101. 2005-04-27 07:35:10 +00:00