* backend/mustek.CHANGES backend/mustek.c backend/mustek.desc
backend/mustek.h doc/sane-mustek.man: Added calibration for Pro
scanners and the SE 12000 SP Plus. Added option to use the full
legal size of the Paragon 1200 LS scanner. Added fast preview for
Pro scanners. Bug fixes. New version: 1.0-103.
Added bit-depth selection again.
Fixed problem with bilevel scanning with Perfection610: The
line count has to be an even number with this scanner.
Several initialization fixes regarding bit depth selection.
This version goes back into the CVS repository, the 1.0.4
release is out and therefore the code freeze is over.
Some general cleanup, added more comments
* TODO: Removed entry about net/saned crashes.
* backend/net.c: Fixed segfault when using SANE_TYPE_STRING options
(e.g. scanimage on localhost). Added checks to prevent other
segfaults. Fixed some warnings.
* backend/snapscan.desc: Changed to use new homepage.
* NEWS: Added date of release.
* TODO: Removed entries about PATH_MAX, sanei_scsi_find_devices, and
shm.h. Added entry about the necessity to check HAVE_SYS_SHM_H.
* configure configure.in include/sane/config.h.in: Default to
--enable-warnings again. Don't set "-ansi" for OS/2. Test for
sys/shm.h.
* backend/GUIDE: Moved to doc/backend-writing.txt.
* doc/backend-writing.txt: New file (moved from backend/GUIDE).
Added comments about sanei-backend.h and PATH_MAX.
* include/sane/sanei_backend.h: Added define for PATH_MAX (if
necessary).
* sanei/sanei_scsi.c: Implemented sanei_scsi_find_devices for FreeBSD
(from ports@FreeBSD.org).
* tools/Makefile.in: Use INSTALL_SCRIPT instead of INSTALL_PROGRAM for
sane-config (from ports@FreeBSD.org).
* backend/mustek.c backend/mustek.desc backend/mustek.CHANGES:
Fixed wrong comment in encode_resolution. Added missing test for
return status in sane_start. Fixed wrong calculation of tlx and
tly for Pro series scanners. Increased version number.
* NEWS: Updated backend versions. Added point about compilation fixes
on Irix and FreeBSD.
* backend/mustek.c backend/mustek.desc backend/mustek.CHANGES:
Fixed problem with lamp control of SE scanners and reduced
length of scan area for Paragon 1200 SP PRO. Removed warning for
this scanner. Increased version number.
* TODO: Updated. Added point about plustek-share.h using c++ comment
and reminder to check config.in.h. Removed entriy about as6e.c stat
result check.
* backend/as6e.c backend/as63.h: Comitted patch from Eugene Weiss
<eweiss@sas.upenn.edu>. Fixes: Use only DBG (no printfs). Check result
of stat. Add GPL header.
Removed changes regarding 12/14 bit support because of SANE
feature freeze for 1.0.4.
The following fixes are in the software compared to the version
prior to the feature freeze:
- refresh UI after a change in the scan mode setting (was not updated
when going from Binary to Gray or vice versa)
- Read values for "line distance" from the scanner instead of using
hardcoded values. This makes sure the backend always uses the correct
values regardless of firmware version.
- Fixed an "off-by-one" error in the color reordering routine that
caused weird artifacts in some instances.
wrong old installation of libsane.la
$(INSTALL_PROGRAM) libsane.la $(libdir)/libsane.la
to this:
$(LIBTOOL) $(MINST) $(INSTALL_PROGRAM) libsane.la $(libdir)/libsane.la
Oliver Rauch
* AUTHORS: Added Karsten Festag as maintainer of microtek2.
* backend/mustek.* doc/sane-mustek.man: Update to Mustek backend
1.0-100. Added option fast-preview that tries to use the fastest
mode available for preview. This is supported for the 3-pass
scanners (was option "preview in gray") and some of the
ScanExpress scanners (6000 SP, 12000 SP Plus). Use #include
"../include/sane/...". Put option force-wait into mustek.conf
(disabled). Removed block mode for Paragon 6000 SP and 8000 SP.
Code cleanup. More debug output. Details in backend/mustek.CHANGES.
* doc/.cvsignore: Added sane-as6e.5 and sane-nec.5.
* configure configure.in acinclude.m4 aclocal.m4
include/sane/config.h.in: Added test for PTAL library and headers
(patch from David Paschal <paschal@rcsis.co>). Some reformating of
the output of configure --help.
* backend/GUIDE: Updated entry about #include.
* changed configure.in, configure frontend/Makefile.in
and backend/Makfile.in:
The shared libraries required by the backends are linked to
the backends (they have been linked to the frontends before).
Only libintl is linked to the frontend.
* changed tool/sane-config.in, sane-config --libs => "-lsane",
all other libraries are linked to the backend libs now
* doc/scanimage.man doc/saned.man: updated description of password
file
* sanei/sanei_auth.c frontend/saned.c frontend/scanimage.c: replaced
index() by strchr(). Changed style of password file
* backend/net.c: the net backend now prepends net:host: to the
resource before calling the auth_callback function
* NEWS: Updated for SANE 1.0.4. Please check.
* README.aix: Removed paragraph about shared libs not working.
* README.linux: Added paragraph about excessive warnings due to glibc
bug (from Peter Kirchgessner).
* TODO: Removed entry about shared libs not working on AIX. Added entry
about PTAL checks. Removed entry about DBG and microtek2. Added entry
about dc210 and jpeg functions. Added entry about using strchr()
instead of index().
* sane.lsm: Added NEC.
* backend/microtek2.c: (from karsten.festag@t-online.de (Karsten
Festag)) Use DBG instead of printf/fprintf. Use
#include "../sane/include/..." instead of #include "sane/...". Fixed
warnings.
* AUTHORS: Added FUKUDA Kazuya for the nec Backend. Used spaces instead
of tabs.
* PROJECTS: Removed entry about NEC. Added/updated entries about Mustek
USB scanners.
* README: Added link to sane-nec(5).
* TODO: Removed entries about sanei_authorize and plain text passwords.
* backend/Makefile.in backend/dll.conf backend/nec.conf backend/nec.c
backend/nec.desc backend/nec.h doc/Makefile.in doc/sane-nec.man:
Added nec backend for the NEC scanners PC-IN500/4C (from Kazuya Fukuda
<fukuda@pjs.nevt.nec.co.jp>)
* configure configure.in: Added test for /dev/urandom and
index() in string.h or strings.h
* backend/net.c: Fixed SANE_NET_AUTHORIZE call handling
* doc/net.tex: Clarified definition of SANE_NET_AUTHORIZE, added
definition of MD5 authorization
* doc/sane.tex: Upgraded to version 1.0.2, changed definition of
SANE_MAX_USERNAME_LEN & SANE_MAX_PASSWORD_LEN to 128 chars
* doc/saned.man: added description of SANE_CONFIG_DIR/saned.users
* doc/scanimage.man: added description of ~/.sane/pass and
--accept-md5-only
* frontend/saned.c: implemented user authorization on a per backend
basis
* frontend/scanimage.c: fixed bug (option -b wasn't present)
implemented auth_callback
* include/sane/sane.h: changed definition of SANE_MAX_USERNAME_LEN &
SANE_MAX_PASSWORD_LEN to 128 chars
* lib/Makefile.in sanei/Makefile.in: updated Makefiles
* backend/pnm.c: Fixed three segfaults due to buffer overruns:
maximum length of filename wasn't checked; maximum length in
sane_read wasn't always checked; ppm_type wasn't always set in
getparmfromfile. Added some checks for safety and removal of
warnings. Added DBG lines for every SANE API call.
* TODO: Added entries about the backend:devicename issue. Add a
comment about fronends not to crash when length is -1. Added entry
about sane-pie. Added point about fronends not checking if too
much data is delivered with sane_read.
* PROJECTS: Added entry about sane-pie.
* backend/mustek.*: Update to Mustek backend 1.0-97. This is a
development version and is only tested for three-pass scanners.
Added support for Paragon 1200 SP Pro and ScanExpress A3 SP.
Removed detection of " C04" and " C12" (don't seem to exist).
Changed SCSI request scheme. Sane_read can read more than 4096
bytes from pipe. Minimum dpi is 30 now. Fixed LD correction for
Paragon 1200SP 1.06 and 1.11. Read SCSI buffer into big block and
do LD after that for Paragon one-pass scanners. New option
"blocksize" in mustek.conf. Better detection of the scanner type
(three-pass, Paragon I, ...). Fixed possible segmentation faults
in Paragon 600 II N LD code, scsi_sense_wait_ready and
sense_handler. Decreased maximum scan size of Paragon 800 II
SP. For three-pass scanners: fixed stop_scan and speed code, scan
area is in pixels now, added RGB brightness and contrast, use
+-100% for brightness and contrast. Return SANE_STATUS_CANCELLED
when scan was cancelled. Option "force backtracking" is enabled by
default, "scan speed" is set to "fastest". Added option
"force-warn" for mustek.conf. Rewrote halftone mode. Better error
handling and more debug output.
* TODO: Clarified point about image data polarity. Moved point about
xscanimage not updating the progress bar for 3pass scanners to
frontend section. Removed umax entry in "frontends". Removed entry
about alpha channel (was added to LEVEL2 file).
* LEVEL2: Add point about image data polarity.
* frontend/scanimage.c: Removed some warnings.
- Added support for flatbed HP OfficeJets
- (PK) fix problem with cancel preview
hp-backend V 0.91, V 0.90, 02-Sep-2000, PK:
- fix timing problem between killing child and writing to pipe
- change fprintf(stderr,...) to DBG
- change include <sane..> to "sane.." in hp.h
- change handling of options that have global effects.
i.e. if option scanmode is received (has global effect),
all options that "may change" are send to the scanner again.
This fixes a problem that --resolution specified infront of
--mode on command line of scanimage was ignored.
NOTE: This change does not allow to specify --depth 12 infront of
--mode color, because --depth is only enabled with --mode color.
- add depth greater 8 bits for mode grayscale
- add option for 8 bit output but 10/12 bit scanning
* TODO: Updated. Added entries for viceo backend and addition to hp
backend. Updated entries about the include issue. Added point about
additional options for pnm backend, install problem of libsane.la,
and some build problems and the --without-x problem. Some more
details for detecting older SANE versions.
* LEVEL2: Added entry about sending messages from backend to frontend.
Removed entry about image polarity.
* backend/mustek.c backend/mustek.h backend/mustek.CHANGES
backend/mustek.desc: Update to Mustek backend 1.0-99. Better
transparency adapter support for ScanExpress scanners. Changed
color support for ScanExpress scanners (faster at some resolutions
now). Paragon 1200 SP color mode should work now without garbage at
the end of an image. Some bugfixes. Details in
backend/mustek.CHANGES.
* tools/find-scanner.c: Explicitly state that find-scanner won't
find non-SCSI scanners.
* doc/scanimage.man: Add examples for SANE device names.
* frontend/scanimage.c: Output message when no devices are found.
Add example for devicename to --help message. Print warning
when a Unix devicename is used instead of a SANE device. Removed
compiler warning.
* TODO: Removed entries about the fgets and include issues in
umax. Removed entries about scanimage device name
documentation. Added a point about xscanimage problems with the
new GIMP API.
* backend/mustek.* doc/sane-mustek.man: Update to Mustek backend
1.0-98. Fixed segmentation fault in sane_init. Enabled double
buffering. Clear inquiry buffer before using. Paragon 1200 SP now
uses LD_BLOCK color correction. Removed LD MFS (wasn't used
anymore). Fix sane_cancel for Paragon series II scanners. Fix
halftone and grain for Paragon series II scanners. Backtracking is
used automaticly by all scanners now. Some safety checks, code
cleanup and more debug output. Details are in
backend/mustek.CHANGES.
* backend/mustek.*: Update to Mustek backend 1.0-97. This is a
development version and is only tested for three-pass scanners.
Added support for Paragon 1200 SP Pro and ScanExpress A3 SP.
Removed detection of " C04" and " C12" (don't seem to exist).
Changed SCSI request scheme. Sane_read can read more than 4096
bytes from pipe. Minimum dpi is 30 now. Fixed LD correction for
Paragon 1200SP 1.06 and 1.11. Read SCSI buffer into big block and
do LD after that for Paragon one-pass scanners. New option
"blocksize" in mustek.conf. Better detection of the scanner type
(three-pass, Paragon I, ...). Fixed possible segmentation faults
in Paragon 600 II N LD code, scsi_sense_wait_ready and
sense_handler. Decreased maximum scan size of Paragon 800 II
SP. For three-pass scanners: fixed stop_scan and speed code, scan
area is in pixels now, added RGB brightness and contrast, use
+-100% for brightness and contrast. Return SANE_STATUS_CANCELLED
when scan was cancelled. Option "force backtracking" is enabled by
default, "scan speed" is set to "fastest". Added option
"force-warn" for mustek.conf. Rewrote halftone mode. Better error
handling and more debug output.
* TODO: Clarified point about image data polarity. Moved point about
xscanimage not updating the progress bar for 3pass scanners to
frontend section. Removed umax entry in "frontends". Removed entry
about alpha channel (was added to LEVEL2 file).
* LEVEL2: Add point about image data polarity.
* frontend/scanimage.c: Removed some warnings.
Man page and mustek.desc now list all the known scanner names
Added maintainer infos to AUTHORS and mustek.c; web page link to mustek.desc and man page
* backend/umax.c, bachend/umax-scanner.c, backend/umax.desc,
doc/umax/sane-umax-config-doc.html, doc/umax/umax.CHANGES,
doc/sane-umax.man:
update to sane-umax-1.0 build 30:
- added EDGE KTX-9600US as supported scanner
- Changing scansource does not change lower left selection
edge if not necessary
* backend/umax*: bugfixes:
* bugfix for DOR:
- bottom-right edge keeps in position if possible when DOR is switched on
* bugfix for Astra 610S color mode:
- scale_y is set to 0.5 if y_resolutions is smaller than optical_res/2
this does fix the color scan problems for Astra 610S.
Not tested for Astra 600S.
* Changelog: added snapshot marker 2001-06-17
* backend/umax*: bugfixes:
- removed "#include <assert.h>" from umax.c: assert() is never called
- bugfix for 3 pass scanning:
reposition_scanner is called in sane_start for 2nd and 3rd pass of 3 pass scan
- bugfix for UTA and DOR geometry offsets