| 
									
										
										
										
											2002-11-29 20:15:39 +00:00
										 |  |  | .TH sane-st400 5 "08 Mar 1999" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy" | 
					
						
							| 
									
										
										
										
											2000-08-12 15:11:46 +00:00
										 |  |  | .IX sane-st400 | 
					
						
							|  |  |  | .SH NAME | 
					
						
							| 
									
										
										
										
											2002-11-29 20:15:39 +00:00
										 |  |  | sane-st400 \- SANE backend for Siemens ST/Highscan flatbed scanners | 
					
						
							| 
									
										
										
										
											2000-08-12 15:11:46 +00:00
										 |  |  | .SH DESCRIPTION | 
					
						
							|  |  |  | The | 
					
						
							|  |  |  | .B sane-st400 | 
					
						
							|  |  |  | library implements a SANE (Scanner Access Now Easy) backend that | 
					
						
							|  |  |  | provides access to Siemens ST400 flatbed scanners and compatibles. | 
					
						
							|  |  |  | At present, the following scanners are supported by this backend: | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | .RS | 
					
						
							|  |  |  | Siemens ST400 (6 bit gray scale) | 
					
						
							|  |  |  | .br | 
					
						
							|  |  |  | Siemens ST800 (6 bit gray scale) | 
					
						
							|  |  |  | .br | 
					
						
							|  |  |  | .RE | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | The driver supports line art and gray scans up to 8bpp. | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | The Siemens ST/Highscan series includes several more models, e.g. the ST300 | 
					
						
							|  |  |  | and ST600.  If you own one of these scanners, or a scanner other than the | 
					
						
							|  |  |  | ones listed above that works with this backend, please let us know by sending | 
					
						
							|  |  |  | the scanner's model name, SCSI ID, and firmware revision to | 
					
						
							| 
									
										
										
										
											2003-09-24 14:55:50 +00:00
										 |  |  | .IR sane\-devel@lists.alioth.debian.org . | 
					
						
							|  |  |  | Have a look at http://www.sane\-project.org/mailing\-lists.html concerning subscription | 
					
						
							| 
									
										
										
										
											2001-10-09 19:30:58 +00:00
										 |  |  | to sane-devel. | 
					
						
							| 
									
										
										
										
											2000-08-12 15:11:46 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | .SH "DEVICE NAMES" | 
					
						
							|  |  |  | This backend expects device names of the form: | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | .RS | 
					
						
							|  |  |  | .I special | 
					
						
							|  |  |  | .RE | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | Where | 
					
						
							|  |  |  | .I special | 
					
						
							|  |  |  | is either the path-name for the special device that corresponds to a | 
					
						
							|  |  |  | SCSI scanner. For SCSI scanners, the special device name must be a | 
					
						
							|  |  |  | generic SCSI device or a symlink to such a device.  Under Linux, such | 
					
						
							|  |  |  | a device name could be | 
					
						
							|  |  |  | .I /dev/sga | 
					
						
							|  |  |  | or | 
					
						
							|  |  |  | .IR /dev/sge , | 
					
						
							|  |  |  | for example.  See sane-scsi(5) for details. | 
					
						
							|  |  |  | .SH CONFIGURATION | 
					
						
							|  |  |  | The contents of the | 
					
						
							|  |  |  | .I st400.conf | 
					
						
							|  |  |  | file is a list of device names that correspond to Siemens | 
					
						
							|  |  |  | scanners.  Empty lines and lines starting with a hash mark (#) are | 
					
						
							|  |  |  | ignored.  A sample configuration file is shown below: | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | .RS | 
					
						
							|  |  |  | /dev/scanner | 
					
						
							|  |  |  | .br | 
					
						
							|  |  |  | # this is a comment | 
					
						
							|  |  |  | .br | 
					
						
							|  |  |  | /dev/sge | 
					
						
							|  |  |  | .RE | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | The default configuration file that is distributed with SANE looks like | 
					
						
							|  |  |  | this: | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | .RS | 
					
						
							|  |  |  | scsi SIEMENS "ST 400" Scanner * * 3 0 | 
					
						
							|  |  |  | .RE | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | In this configuration, the driver can only access the ST400 model | 
					
						
							|  |  |  | at SCSI ID 3 LUN 0 (see section "BUGS" below for the reason). | 
					
						
							|  |  |  | To use the driver with other scanner models, add an appropriate line to | 
					
						
							|  |  |  | the configuration file.  For example, to use it with an ST800 at SCSI | 
					
						
							|  |  |  | ID 3 LUN 0, add the line: | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | .RS | 
					
						
							|  |  |  | scsi SIEMENS "ST 800" Scanner * * 3 0 | 
					
						
							|  |  |  | .RE | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH FILES | 
					
						
							|  |  |  | .TP | 
					
						
							|  |  |  | .I @CONFIGDIR@/st400.conf | 
					
						
							|  |  |  | The backend configuration file (see also description of | 
					
						
							|  |  |  | .B SANE_CONFIG_DIR | 
					
						
							|  |  |  | below). | 
					
						
							|  |  |  | .TP | 
					
						
							|  |  |  | .I @LIBDIR@/libsane-st400.a | 
					
						
							|  |  |  | The static library implementing this backend. | 
					
						
							|  |  |  | .TP | 
					
						
							|  |  |  | .I @LIBDIR@/libsane-st400.so | 
					
						
							|  |  |  | The shared library implementing this backend (present on systems that | 
					
						
							|  |  |  | support dynamic loading). | 
					
						
							|  |  |  | .SH ENVIRONMENT | 
					
						
							|  |  |  | .TP | 
					
						
							|  |  |  | .B SANE_CONFIG_DIR | 
					
						
							|  |  |  | This environment variable specifies the list of directories that may | 
					
						
							|  |  |  | contain the configuration file.  Under UNIX, the directories are | 
					
						
							|  |  |  | separated by a colon (`:'), under OS/2, they are separated by a | 
					
						
							|  |  |  | semi-colon (`;').  If this variable is not set, the configuration file | 
					
						
							|  |  |  | is searched in two default directories: first, the current working | 
					
						
							|  |  |  | directory (".") and then in /etc/sane.d.  If the value of the | 
					
						
							|  |  |  | environment variable ends with the directory separator character, then | 
					
						
							|  |  |  | the default directories are searched after the explicitly specified | 
					
						
							|  |  |  | directories.  For example, setting | 
					
						
							|  |  |  | .B SANE_CONFIG_DIR | 
					
						
							|  |  |  | to "/tmp/config:" would result in directories "tmp/config", ".", and | 
					
						
							|  |  |  | "/etc/sane.d" being searched (in this order). | 
					
						
							|  |  |  | .TP | 
					
						
							|  |  |  | .B SANE_DEBUG_ST400 | 
					
						
							|  |  |  | If the library was compiled with debug support enabled, this environment | 
					
						
							|  |  |  | variable controls the debug level for this backend. E.g., a value of 128 | 
					
						
							|  |  |  | requests all debug output to be printed. Smaller levels reduce verbosity. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH MISSING FUNCTIONALITY | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Everything but the most basic stuff. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH BUGS | 
					
						
							|  |  |  | Currently, the backend does not check if the attached device really is | 
					
						
							|  |  |  | a ST400.  It will happily accept everything that matches the configuration | 
					
						
							|  |  |  | entries.  This makes it easy to test the backend with other scanners: | 
					
						
							|  |  |  | Just add an appropriate line to the configuration file.  The configuration | 
					
						
							|  |  |  | file as distributed (see above) only works with the ST400.  Be careful: | 
					
						
							|  |  |  | If there is no config file at all, the backend defaults to /dev/scanner. | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | The ST400 answers on all eight SCSI LUNs.  Normally this is not a problem, | 
					
						
							|  |  |  | as LUN support is usually disabled in SCSI drivers, but if you are seeing | 
					
						
							|  |  |  | multiple instances of the scanner in a device list, either disable LUNs in | 
					
						
							|  |  |  | your SCSI setup or change the entry in the configuration file to match | 
					
						
							|  |  |  | LUN 0 only. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH DEBUG | 
					
						
							|  |  |  | If you encounter a bug please set the environment variable | 
					
						
							|  |  |  | SANE_DEBUG_ST400 to 128 and try to regenerate the problem. Then | 
					
						
							|  |  |  | send me a report with the log attached. | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | If you encounter a SCSI bus error or trimmed and/or displaced images please | 
					
						
							|  |  |  | also set the environment variable SANE_DEBUG_SANEI_SCSI to 128 before sending | 
					
						
							|  |  |  | me the report. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH "SEE ALSO" | 
					
						
							| 
									
										
										
										
											2001-06-10 14:28:46 +00:00
										 |  |  | sane(7), sane\-scsi(5) | 
					
						
							| 
									
										
										
										
											2000-08-12 15:11:46 +00:00
										 |  |  | .br | 
					
						
							|  |  |  | http://www.informatik.uni-oldenburg.de/~ingo/sane/  | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH AUTHOR | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Ingo Wilken <Ingo.Wilken@informatik.uni\-oldenburg.de> |