| 
									
										
										
										
											2002-11-29 20:15:39 +00:00
										 |  |  | .TH sane-coolscan 5 "4 July 2000" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy" | 
					
						
							| 
									
										
										
										
											2000-08-12 15:11:46 +00:00
										 |  |  | .IX sane-coolscan | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH NAME | 
					
						
							| 
									
										
										
										
											2002-11-29 20:15:39 +00:00
										 |  |  | sane-coolscan \- SANE backend for Nikon film-scanners | 
					
						
							| 
									
										
										
										
											2000-08-12 15:11:46 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | .SH ABOUT THIS FILE | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | This file is a short descripton of the coolscan-backend for sane!  | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH DESCRIPTION | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The | 
					
						
							|  |  |  | .B sane-coolscan | 
					
						
							|  |  |  | library implements a SANE backend that provides the interface to the following Nikon Coolscan Film scanners: Nikon LS20, LS30, LS1000, LS2000. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2001-06-10 13:32:31 +00:00
										 |  |  | .B Even though the backend has worked for a number of people, there are still some problems, especially in combination with some SCSI card/drivers (AHA-1505/aha152x.o) and the autofocus command. You should consider this backend 'alpha' and be carefull when using it the first time. | 
					
						
							| 
									
										
										
										
											2000-08-12 15:11:46 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | .SH CONFIGURATION | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The configuration file for this backend resides in  | 
					
						
							| 
									
										
										
										
											2001-06-10 15:42:45 +00:00
										 |  |  | @CONFIGDIR@/coolscan.conf.  | 
					
						
							| 
									
										
										
										
											2000-08-12 15:11:46 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | Its contents is a list of device names that correspond to Nikon Coolscan scanners. Empty lines | 
					
						
							|  |  |  | and lines starting with a hash mark (#) are ignored. A sample configuration file is | 
					
						
							|  |  |  | shown below:  | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  |  #scsi Vendor Model Type  | 
					
						
							|  |  |  |  scsi Nikon * Scanner  | 
					
						
							|  |  |  |  /dev/scanner  | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The special device name must be a generic SCSI device or a symlink to such a device. | 
					
						
							|  |  |  | To find out to which device your scanner is assigned and how you have to set the | 
					
						
							|  |  |  | permissions of that device, have a look at sane-scsi.  | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH SCSI ADAPTER TIPS | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Some SCSI-adapters and low-level SCSI drivers do not work correctly with this backend and the | 
					
						
							|  |  |  | Coolscan scanners. These systems hang when the autofocus command is send to the Scanner. | 
					
						
							|  |  |  | To see a list of which card/driver combinations work or dont work have a look at: | 
					
						
							|  |  |  | http://andreas.rick.free.fr/sane/autofocus.html. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH FILES | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | The backend configuration file: | 
					
						
							| 
									
										
										
										
											2001-06-10 15:42:45 +00:00
										 |  |  |  @CONFIGDIR@/coolscan.conf.  | 
					
						
							| 
									
										
										
										
											2000-08-12 15:11:46 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | The static library implementing this backend: | 
					
						
							| 
									
										
										
										
											2001-06-10 16:25:53 +00:00
										 |  |  |  @LIBDIR@/libsane-coolscan.a | 
					
						
							| 
									
										
										
										
											2000-08-12 15:11:46 +00:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2001-06-10 15:42:45 +00:00
										 |  |  | The shared library implementing this backend: | 
					
						
							| 
									
										
										
										
											2001-06-10 16:25:53 +00:00
										 |  |  |  @LIBDIR@/libsane-coolscan.so | 
					
						
							| 
									
										
										
										
											2000-08-12 15:11:46 +00:00
										 |  |  |  (present on systems that support dynamic loading) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH ENVIRONMENT | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .B SANE_DEBUG_COOLSCAN | 
					
						
							|  |  |  |  If the library was compiled with debug support enabled, this environment | 
					
						
							|  |  |  | variable controls the debug level for this backend. E.g., a value of 128 | 
					
						
							|  |  |  | requests all debug output to be printed. Smaller levels reduce verbosity: | 
					
						
							|  |  |  | SANE_DEBUG_COOLSCAN values | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Examples: | 
					
						
							|  |  |  |  on bash: | 
					
						
							|  |  |  |  export SANE_DEBUG_COOLSCAN=8 | 
					
						
							|  |  |  |  on csh | 
					
						
							|  |  |  |  setenv SANE_DEBUG_COOLSCAN 8 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH BUGS | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  |  The autofocus command does not work with some SCSI card/driver combinations | 
					
						
							|  |  |  |  The gamma table is not implemented for the LS1000 yet. | 
					
						
							|  |  |  |  The dust-removal is not working yet | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH SEE ALSO | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  |  http://andreas.rick.free.fr/sane/ The homepage of this backend | 
					
						
							|  |  |  |  http://www.sema.be/coolscan/  The original version of the coolscan backend by Didier | 
					
						
							| 
									
										
										
										
											2001-06-10 13:32:31 +00:00
										 |  |  |  sane(7), sane\-scsi(5) | 
					
						
							| 
									
										
										
										
											2000-08-12 15:11:46 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | .SH THANKS TO | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  |  Didier Carlier - For writing the original Coolscan backend (without it I would not have started this)  | 
					
						
							|  |  |  |  Oliver.Rauch - For adapting xsane so quickly to the infrared stuff. | 
					
						
							|  |  |  |  All the other people working on SANE. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH AUTHOR | 
					
						
							|  |  |  | Andreas Rick | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH EMAIL-CONTACT | 
					
						
							|  |  |  | andreas.rick@free.fr |