Update BME68X and BME690 examples

pull/1073/head
Hel Gibbons 2025-04-15 11:14:16 +01:00
rodzic 575e3a17bc
commit f8548e4d34
4 zmienionych plików z 135 dodań i 17 usunięć

Wyświetl plik

@ -11,23 +11,25 @@
## Getting Started
Construct new `PimoroniI2C` and `BreakoutBME68X` instances:
Construct new `I2C` and `BreakoutBME68X` instances:
```python
from breakout_bme68x import BreakoutBME68X
from pimoroni_i2c import PimoroniI2C
PINS_BREAKOUT_GARDEN = {"sda": 4, "scl": 5}
PINS_PICO_EXPLORER = {"sda": 20, "scl": 21}
i2c = PimoroniI2C(**PINS_PICO_EXPLORER)
i2c = machine.I2C()
bme = BreakoutBME68X(i2c)
```
The `breakout_bme68x` module includes constants for the possible I2C addresses:
The default I2C address is `0x76`. If you've cut the trace to change the I2C address of the sensor, you can specify the alternate I2C address like this:
* `ADDRESS_DEFAULT`
* `ADDRESS_ALT`
``` python
bme = BreakoutBME68X(i2c, 0x77)
```
The `breakout_bme68x` module also includes constants for the possible I2C addresses:
* `I2C_ADDRESS_DEFAULT`
* `I2C_ADDRESS_ALT`
## Reading Data From The Sensor

Wyświetl plik

@ -2,18 +2,14 @@
This demo will work for both the BME680 and BME688.
"""
import machine
import time
from breakout_bme68x import BreakoutBME68X, STATUS_HEATER_STABLE
from pimoroni_i2c import PimoroniI2C
PINS_BREAKOUT_GARDEN = {"sda": 4, "scl": 5}
PINS_PICO_EXPLORER = {"sda": 20, "scl": 21}
i2c = PimoroniI2C(**PINS_BREAKOUT_GARDEN)
bme = BreakoutBME68X(i2c)
bme = BreakoutBME68X(machine.I2C(), 0x76)
# If this gives an error, try the alternative address
# bme = BreakoutBME68X(i2c, 0x77)
# bme = BreakoutBME68X(machine.I2C(), 0x77)
while True:
temperature, pressure, humidity, gas, status, _, _ = bme.read()

Wyświetl plik

@ -0,0 +1,101 @@
# BME69X <!-- omit in toc -->
- [Getting Started](#getting-started)
- [Reading Data From The Sensor](#reading-data-from-the-sensor)
- [Configuring The Sensor](#configuring-the-sensor)
- [Filter Settings](#filter-settings)
- [Oversampling Settings](#oversampling-settings)
- [Mode Settings](#mode-settings)
- [Standby/Output Data Rate Settings](#standbyoutput-data-rate-settings)
- [Defaults](#defaults)
## Getting Started
Construct new `I2C` and `BreakoutBME69X` instances:
```python
from breakout_bme69x import BreakoutBME69X
i2c = machine.I2C()
bme = BreakoutBME69X(i2c)
```
The default I2C address is `0x76`. If you've cut the trace to change the I2C address of the sensor, you can specify the alternate I2C address like this:
``` python
bme = BreakoutBME69X(i2c, 0x77)
```
The `breakout_bme69x` module also includes constants for the possible I2C addresses:
* `I2C_ADDRESS_DEFAULT`
* `I2C_ADDRESS_ALT`
## Reading Data From The Sensor
The `read` method will return a tuple containing Temperature (degrees C), Pressure (Pa), relative humidity (%rH), and gas resistance (Ω) values, plus the status code and gas/measurement indexes:
```python
temperature, pressure, humidity, gas_resistance, status, gas_index, meas_index = bme.read()
```
In all cases `gas_index` and `meas_index` will be zero, since these refer to the measurement profile used to gather the current readings. The MicroPython bindings currently only support a single measurement profile with a default of 300c for 100ms.
You can pass a custom temperature and duration into `read`:
```python
temperature, pressure, humidity, gas_resistance, status, gas_index, meas_index = bme.read(heater_temp=250, heater_duration=50)
```
## Configuring The Sensor
The `configure` method allows you to set up the oversampling, filtering and operation mode.
```python
bme.configure(filter, standby_time, os_pressure, os_temp, os_humidity)
```
The `breakout_bme69x` module includes constants for these:
### Filter Settings
* `FILTER_COEFF_OFF`
* `FILTER_COEFF_1`
* `FILTER_COEFF_3`
* `FILTER_COEFF_8`
* `FILTER_COEFF_15`
* `FILTER_COEFF_31`
* `FILTER_COEFF_63`
* `FILTER_COEFF_127`
### Oversampling Settings
* `NO_OVERSAMPLING`
* `OVERSAMPLING_1X`
* `OVERSAMPLING_2X`
* `OVERSAMPLING_4X`
* `OVERSAMPLING_8X`
* `OVERSAMPLING_16X`
### Mode Settings
* `SLEEP_MODE`
* `FORCED_MODE`
* `NORMAL_MODE`
### Standby/Output Data Rate Settings
* `STANDBY_TIME_0_59_MS`
* `STANDBY_TIME_62_5_MS`
* `STANDBY_TIME_125_MS`
* `STANDBY_TIME_250_MS`
* `STANDBY_TIME_500_MS`
* `STANDBY_TIME_1000_MS`
* `STANDBY_TIME_10_MS`
* `STANDBY_TIME_20_MS`
### Defaults
```python
bme.configure(FILTER_COEFF_3, STANDBY_TIME_1000_MS, OVERSAMPLING_16X, OVERSAMPLING_2X, OVERSAMPLING_1X)
```

Wyświetl plik

@ -0,0 +1,19 @@
"""BME69X demo
Demo of how to read the BME690 sensor.
"""
import machine
import time
from breakout_bme69x import BreakoutBME69X, STATUS_HEATER_STABLE
bme = BreakoutBME69X(machine.I2C(), 0x76)
# If this gives an error, try the alternative address
# bme = BreakoutBME69X(machine.I2C(), 0x77)
while True:
temperature, pressure, humidity, gas, status, _, _ = bme.read()
heater = "Stable" if status & STATUS_HEATER_STABLE else "Unstable"
print("{:0.2f}c, {:0.2f}Pa, {:0.2f}%, {:0.2f} Ohms, Heater: {}".format(
temperature, pressure, humidity, gas, heater))
time.sleep(1.0)