kopia lustrzana https://github.com/jgromes/RadioLib
[SX1278] Add support for coding rate 4/4
rodzic
47bc673bc5
commit
b7fbf2fc23
|
@ -29,7 +29,8 @@ class SX1276: public SX1278 {
|
|||
\param freq Carrier frequency in MHz. Allowed values range from 137.0 MHz to 1020.0 MHz.
|
||||
\param bw %LoRa link bandwidth in kHz. Allowed values are 7.8, 10.4, 15.6, 20.8, 31.25, 41.7, 62.5, 125, 250 and 500 kHz.
|
||||
\param sf %LoRa link spreading factor. Allowed values range from 6 to 12.
|
||||
\param cr %LoRa link coding rate denominator. Allowed values range from 5 to 8.
|
||||
\param cr %LoRa link coding rate denominator. Allowed values range from 4 to 8. Note that a value of 4 means no coding,
|
||||
is undocumented and not recommended without your own FEC.
|
||||
\param syncWord %LoRa sync word. Can be used to distinguish different networks. Note that value 0x34 is reserved for LoRaWAN networks.
|
||||
\param power Transmission output power in dBm. Allowed values range from 2 to 17 dBm.
|
||||
\param preambleLength Length of %LoRa transmission preamble in symbols. The actual preamble length is 4.25 symbols longer than the set number.
|
||||
|
|
|
@ -149,7 +149,7 @@ int16_t SX1277::checkDataRate(DataRate_t dr) {
|
|||
} else if(modem == RADIOLIB_SX127X_LORA) {
|
||||
RADIOLIB_CHECK_RANGE(dr.lora.spreadingFactor, 6, 9, RADIOLIB_ERR_INVALID_SPREADING_FACTOR);
|
||||
RADIOLIB_CHECK_RANGE(dr.lora.bandwidth, 0.0f, 510.0f, RADIOLIB_ERR_INVALID_BANDWIDTH);
|
||||
RADIOLIB_CHECK_RANGE(dr.lora.codingRate, 5, 8, RADIOLIB_ERR_INVALID_CODING_RATE);
|
||||
RADIOLIB_CHECK_RANGE(dr.lora.codingRate, 4, 8, RADIOLIB_ERR_INVALID_CODING_RATE);
|
||||
return(RADIOLIB_ERR_NONE);
|
||||
|
||||
}
|
||||
|
|
|
@ -29,7 +29,8 @@ class SX1277: public SX1278 {
|
|||
\param freq Carrier frequency in MHz. Allowed values range from 137.0 MHz to 1020.0 MHz.
|
||||
\param bw %LoRa link bandwidth in kHz. Allowed values are 7.8, 10.4, 15.6, 20.8, 31.25, 41.7, 62.5, 125, 250 and 500 kHz.
|
||||
\param sf %LoRa link spreading factor. Allowed values range from 6 to 9.
|
||||
\param cr %LoRa link coding rate denominator. Allowed values range from 5 to 8.
|
||||
\param cr %LoRa link coding rate denominator. Allowed values range from 4 to 8. Note that a value of 4 means no coding,
|
||||
is undocumented and not recommended without your own FEC.
|
||||
\param syncWord %LoRa sync word. Can be used to distinguish different networks. Note that value 0x34 is reserved for LoRaWAN networks.
|
||||
\param power Transmission output power in dBm. Allowed values range from 2 to 17 dBm.
|
||||
\param preambleLength Length of %LoRa transmission preamble in symbols. The actual preamble length is 4.25 symbols longer than the set number.
|
||||
|
|
|
@ -209,6 +209,9 @@ int16_t SX1278::setCodingRate(uint8_t cr) {
|
|||
|
||||
// check allowed coding rate values
|
||||
switch(cr) {
|
||||
case 4:
|
||||
newCodingRate = RADIOLIB_SX1278_CR_4_4;
|
||||
break;
|
||||
case 5:
|
||||
newCodingRate = RADIOLIB_SX1278_CR_4_5;
|
||||
break;
|
||||
|
@ -281,7 +284,7 @@ int16_t SX1278::checkDataRate(DataRate_t dr) {
|
|||
} else if(modem == RADIOLIB_SX127X_LORA) {
|
||||
RADIOLIB_CHECK_RANGE(dr.lora.spreadingFactor, 6, 12, RADIOLIB_ERR_INVALID_SPREADING_FACTOR);
|
||||
RADIOLIB_CHECK_RANGE(dr.lora.bandwidth, 0.0f, 510.0f, RADIOLIB_ERR_INVALID_BANDWIDTH);
|
||||
RADIOLIB_CHECK_RANGE(dr.lora.codingRate, 5, 8, RADIOLIB_ERR_INVALID_CODING_RATE);
|
||||
RADIOLIB_CHECK_RANGE(dr.lora.codingRate, 4, 8, RADIOLIB_ERR_INVALID_CODING_RATE);
|
||||
return(RADIOLIB_ERR_NONE);
|
||||
|
||||
}
|
||||
|
|
|
@ -49,7 +49,8 @@
|
|||
#define RADIOLIB_SX1278_BW_125_00_KHZ 0b01110000 // 7 4 125.00 kHz
|
||||
#define RADIOLIB_SX1278_BW_250_00_KHZ 0b10000000 // 7 4 250.00 kHz
|
||||
#define RADIOLIB_SX1278_BW_500_00_KHZ 0b10010000 // 7 4 500.00 kHz
|
||||
#define RADIOLIB_SX1278_CR_4_5 0b00000010 // 3 1 error coding rate: 4/5
|
||||
#define RADIOLIB_SX1278_CR_4_4 0b00000000 // 3 1 error coding rate: 4/4 (undocumented)
|
||||
#define RADIOLIB_SX1278_CR_4_5 0b00000010 // 3 1 4/5
|
||||
#define RADIOLIB_SX1278_CR_4_6 0b00000100 // 3 1 4/6
|
||||
#define RADIOLIB_SX1278_CR_4_7 0b00000110 // 3 1 4/7
|
||||
#define RADIOLIB_SX1278_CR_4_8 0b00001000 // 3 1 4/8
|
||||
|
@ -120,7 +121,8 @@ class SX1278: public SX127x {
|
|||
\param freq Carrier frequency in MHz. Allowed values range from 137.0 MHz to 525.0 MHz.
|
||||
\param bw %LoRa link bandwidth in kHz. Allowed values are 7.8, 10.4, 15.6, 20.8, 31.25, 41.7, 62.5, 125, 250 and 500 kHz.
|
||||
\param sf %LoRa link spreading factor. Allowed values range from 6 to 12.
|
||||
\param cr %LoRa link coding rate denominator. Allowed values range from 5 to 8.
|
||||
\param cr %LoRa link coding rate denominator. Allowed values range from 4 to 8. Note that a value of 4 means no coding,
|
||||
is undocumented and not recommended without your own FEC.
|
||||
\param syncWord %LoRa sync word. Can be used to distinguish different networks. Note that value 0x34 is reserved for LoRaWAN networks.
|
||||
\param power Transmission output power in dBm. Allowed values range from 2 to 17 dBm.
|
||||
\param preambleLength Length of %LoRa transmission preamble in symbols. The actual preamble length is 4.25 symbols longer than the set number.
|
||||
|
@ -174,7 +176,8 @@ class SX1278: public SX127x {
|
|||
virtual int16_t setSpreadingFactor(uint8_t sf);
|
||||
|
||||
/*!
|
||||
\brief Sets %LoRa link coding rate denominator. Allowed values range from 5 to 8. Only available in %LoRa mode.
|
||||
\brief Sets %LoRa link coding rate denominator. Allowed values range from 4 to 8. Only available in %LoRa mode.
|
||||
Note that a value of 4 means no coding, is undocumented and not recommended without your own FEC.
|
||||
\param cr %LoRa link coding rate denominator to be set.
|
||||
\returns \ref status_codes
|
||||
*/
|
||||
|
|
|
@ -29,7 +29,8 @@ class SX1279: public SX1278 {
|
|||
\param freq Carrier frequency in MHz. Allowed values range from 137.0 MHz to 960.0 MHz.
|
||||
\param bw %LoRa link bandwidth in kHz. Allowed values are 7.8, 10.4, 15.6, 20.8, 31.25, 41.7, 62.5, 125, 250 and 500 kHz.
|
||||
\param sf %LoRa link spreading factor. Allowed values range from 6 to 12.
|
||||
\param cr %LoRa link coding rate denominator. Allowed values range from 5 to 8.
|
||||
\param cr %LoRa link coding rate denominator. Allowed values range from 4 to 8. Note that a value of 4 means no coding,
|
||||
is undocumented and not recommended without your own FEC.
|
||||
\param syncWord %LoRa sync word. Can be used to distinguish different networks. Note that value 0x34 is reserved for LoRaWAN networks.
|
||||
\param power Transmission output power in dBm. Allowed values range from 2 to 17 dBm.
|
||||
\param preambleLength Length of %LoRa transmission preamble in symbols. The actual preamble length is 4.25 symbols longer than the set number.
|
||||
|
|
Ładowanie…
Reference in New Issue