// #define BUTTON_NEED_PULLUP // if set we need to turn on the internal CPU pullup during sleep #define I2C_SDA 21 #define I2C_SCL 22 #define BUTTON_PIN 36 // The middle button GPIO on the Nano G1 //#define BUTTON_PIN_ALT 13 // Alternate GPIO for an external button if needed. Does anyone use this? It is not documented anywhere. #define EXT_NOTIFY_OUT 13 // Default pin to use for Ext Notify Module. // common pinout for their SX1262 vs RF95 modules - both can be enabled and we will probe at runtime for RF95 and if // not found then probe for SX1262 #define USE_RF95 #define USE_SX1262 #define LORA_DIO0 26 // a No connect on the SX1262 module #define LORA_RESET 23 #define LORA_DIO1 33 // SX1262 IRQ #define LORA_DIO2 32 // SX1262 BUSY #define LORA_DIO3 // Not connected on PCB #ifdef USE_SX1262 #define SX126X_CS RF95_NSS // FIXME - we really should define LORA_CS instead #define SX126X_DIO1 LORA_DIO1 #define SX126X_BUSY LORA_DIO2 #define SX126X_RESET LORA_RESET //#define SX126X_E22 // Not really an E22 // Internally the module hooks the SX1262-DIO2 in to control the TX/RX switch (which is the default for the sx1262interface // code) #define SX126X_MAX_POWER 16 //Ensure the PA does not exceed the saturation output power. More Info:https://uniteng.com/wiki/doku.php?id=meshtastic:station#rf_design_-_lora_station_edition_g1 #endif #define BATTERY_PIN 35 // A battery voltage measurement pin, voltage divider connected here to measure battery voltage #define BATTERY_SENSE_SAMPLES 30 //Set the number of samples, It has an effect of increasing sensitivity. #define ADC_MULTIPLIER 6.45 #define BAT_FULLVOLT 12600 #define BAT_EMPTYVOLT 8200 #define BAT_CHARGINGVOLT 12600 #define BAT_NOBATVOLT 6690 // different screen #define USE_SH1106