wmbusmeters/src/driver_minomess.cc

230 wiersze
8.4 KiB
C++

/*
Copyright (C) 2021 Olli Salonen (gpl-3.0-or-later)
2022 Fredrik Öhrström (gpl-3.0-or-later)
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#include"meters_common_implementation.h"
struct MeterMinomess : public virtual MeterCommonImplementation
{
MeterMinomess(MeterInfo &mi, DriverInfo &di);
private:
double total_water_consumption_m3_ {};
string meter_date_;
double target_water_consumption_m3_ {};
string target_date_;
string status_;
};
static bool ok = registerDriver([](DriverInfo&di)
{
di.setName("minomess");
di.setMeterType(MeterType::WaterMeter);
di.setExpectedELLSecurityMode(ELLSecurityMode::AES_CTR);
di.addLinkMode(LinkMode::C1);
di.addDetection(MANUFACTURER_ZRI, 0x07, 0x00);
di.setConstructor([](MeterInfo& mi, DriverInfo& di){ return shared_ptr<Meter>(new MeterMinomess(mi, di)); });
});
MeterMinomess::MeterMinomess(MeterInfo &mi, DriverInfo &di) : MeterCommonImplementation(mi, di)
{
addNumericFieldWithExtractor(
"total",
Quantity::Volume,
NoDifVifKey,
VifScaling::Auto,
MeasurementType::Instantaneous,
VIFRange::Volume,
StorageNr(0),
TariffNr(0),
IndexNr(1),
PrintProperty::JSON | PrintProperty::FIELD | PrintProperty::IMPORTANT,
"The total water consumption recorded by this meter.",
SET_FUNC(total_water_consumption_m3_, Unit::M3),
GET_FUNC(total_water_consumption_m3_, Unit::M3));
/* If the meter is recently commissioned, the target water consumption value is bogus.
The bits store 0xffffffff. Should we deal with this? Now a very large value is printed in the json. */
addStringFieldWithExtractor(
"meter_date",
Quantity::Text,
NoDifVifKey,
MeasurementType::Instantaneous,
VIFRange::Date,
StorageNr(0),
TariffNr(0),
IndexNr(1),
PrintProperty::JSON,
"Date when measurement was recorded.",
SET_STRING_FUNC(meter_date_),
GET_STRING_FUNC(meter_date_));
addNumericFieldWithExtractor(
"target",
Quantity::Volume,
NoDifVifKey,
VifScaling::Auto,
MeasurementType::Instantaneous,
VIFRange::Volume,
StorageNr(8),
TariffNr(0),
IndexNr(1),
PrintProperty::JSON | PrintProperty::FIELD | PrintProperty::IMPORTANT,
"The total water consumption recorded at the beginning of this month.",
SET_FUNC(target_water_consumption_m3_, Unit::M3),
GET_FUNC(target_water_consumption_m3_, Unit::M3));
addStringFieldWithExtractor(
"target_date",
Quantity::Text,
NoDifVifKey,
MeasurementType::Instantaneous,
VIFRange::Date,
StorageNr(8),
TariffNr(0),
IndexNr(1),
PrintProperty::JSON,
"Date when target water consumption was recorded.",
SET_STRING_FUNC(target_date_),
GET_STRING_FUNC(target_date_));
/*
According to data sheet, there are two status/info bytes, byte A and byte B.
Unfortunately we do not now is byte A is the first or second byte. Oh well.
Now we guess that A is the hi byte. I.e. 0x8000 is byte A bit 7.
In the telegram the byte order is: lo byte first followed by the hi byte.
So the defacto telegram bytes would be 0x0080 for byte A bit 7.
Byte A:
bit 7 removal active in the past
bit 6 tamper active in the past
bit 5 leak active in the past
bit 4 temporary error (in connection with smart functions)
bit 3 permanent error (meter value might be lost)
bit 2 battery EOL (measured)
bit 1 abnormal error
bit 0 unused
Byte B:
bit 7 burst
bit 6 removal
bit 5 leak
bit 4 backflow in the past
bit 3 backflow
bit 2 meter blocked in the past
bit 1 meter undersized
bit 0 meter oversized
*/
addStringFieldWithExtractorAndLookup(
"status",
Quantity::Text,
DifVifKey("02FD17"),
MeasurementType::Unknown,
VIFRange::Any,
AnyStorageNr,
AnyTariffNr,
IndexNr(1),
PrintProperty::JSON | PrintProperty::FIELD,
"Status and error flags.",
SET_STRING_FUNC(status_),
GET_STRING_FUNC(status_),
{
{
{
"ERROR_FLAGS",
Translate::Type::BitToString,
0xffff,
"OK",
{
{ 0x8000, "WAS_REMOVED" },
{ 0x4000, "WAS_TAMPERED" },
{ 0x2000, "WAS_LEAKING" },
{ 0x1000, "TEMPORARY_ERROR" },
{ 0x0800, "PERMANENT_ERROR" },
{ 0x0400, "BATTERY_EOL" },
{ 0x0200, "ABNORMAL_ERROR" },
// 0x0100 not used
{ 0x0080, "BURSTING" },
{ 0x0040, "REMOVED" },
{ 0x0020, "LEAKING" },
{ 0x0010, "WAS_BACKFLOWING" },
{ 0x0008, "BACKFLOWING" },
{ 0x0004, "WAS_BLOCKED" },
{ 0x0002, "UNDERSIZED" },
{ 0x0001, "OVERSIZED" }
}
},
},
});
}
// 00: 66 length (102 bytes)
// 01: 44 dll-c (from meter SND_NR)
// 02: 496a dll-mfct (ZRI)
// 04: 10640355 dll-id (55036410)
// 08: 14 dll-version
// 09: 37 dll-type (Radio converter (meter side))
// 0a: 72 tpl-ci-field (EN 13757-3 Application Layer (long tplh))
// 0b: 51345015 tpl-id (15503451)
// 0f: 496a tpl-mfct (ZRI)
// 11: 00 tpl-version
// 12: 07 tpl-type (Water meter)
// 13: 76 tpl-acc-field
// 14: 00 tpl-sts-field (OK)
// 15: 5005 tpl-cfg 0550 (AES_CBC_IV nb=5 cntn=0 ra=0 hc=0 )
// 17: 2f2f decrypt check bytes
// 19: 0C dif (8 digit BCD Instantaneous value)
// 1a: 13 vif (Volume l)
// 1b: * 55140000 total consumption (1.455000 m3)
// 1f: 02 dif (16 Bit Integer/Binary Instantaneous value)
// 20: 6C vif (Date type G)
// 21: * A92B meter date (2021-11-09)
// 23: 82 dif (16 Bit Integer/Binary Instantaneous value)
// 24: 04 dife (subunit=0 tariff=0 storagenr=8)
// 25: 6C vif (Date type G)
// 26: * A12B target consumption reading date (2021-11-01)
// 28: 8C dif (8 digit BCD Instantaneous value)
// 29: 04 dife (subunit=0 tariff=0 storagenr=8)
// 2a: 13 vif (Volume l)
// 2b: * 71000000 target consumption (0.071000 m3)
//
// 2f: 8D dif (variable length Instantaneous value)
// 30: 04 dife (subunit=0 tariff=0 storagenr=8)
// 31: 93 vif (Volume l)
// 32: 13 vife (Reverse compact profile without register)
// 33: 2C varlen=44
// This register has 24-bit integers for the consumption of the past months n-2 until n-15.
// If the meter is commissioned less than 15 months ago, you will see FFFFFF as the value.
// n-2 n-3 n-4 n-5 n-6 n-7 n-8 n-9 n-10 n-11 n-12 n-13 n-14 n-15
// 34: FBFE 000000 FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF FFFFFF
//
// 60: 02 dif (16 Bit Integer/Binary Instantaneous value)
// 61: FD vif (Second extension FD of VIF-codes)
// 62: 17 vife (Error flags (binary))
// 63: * 0000 info codes (OK)
// Test: Mino minomess 15503451 NOKEY
// telegram=|6644496A1064035514377251345015496A0007EE0050052F2F#0C1359000000026CBE2B82046CA12B8C0413FFFFFFFF8D0493132CFBFEFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF02FD1700002F2F|
// {"media":"water","meter":"minomess","name":"Mino","id":"15503451","total_m3":0.059,"meter_date":"2021-11-30","target_m3":244444.442,"target_date":"2021-11-01","status":"OK","timestamp":"1111-11-11T11:11:11Z"}
// |Mino;15503451;0.059000;244444.442000;OK;1111-11-11 11:11.11