kopia lustrzana https://github.com/weetmuts/wmbusmeters
90 wiersze
3.4 KiB
C++
90 wiersze
3.4 KiB
C++
/*
|
|
Copyright (C) 2021-2022 Fredrik Öhrström (gpl-3.0-or-later)
|
|
|
|
This program is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
|
|
#include"meters_common_implementation.h"
|
|
|
|
namespace
|
|
{
|
|
struct Driver : public virtual MeterCommonImplementation
|
|
{
|
|
Driver(MeterInfo &mi, DriverInfo &di);
|
|
};
|
|
|
|
static bool ok = registerDriver([](DriverInfo&di)
|
|
{
|
|
di.setName("weh_07");
|
|
di.setDefaultFields("name,id,total_m3,timestamp");
|
|
di.setMeterType(MeterType::WaterMeter);
|
|
di.addLinkMode(LinkMode::C1);
|
|
di.addDetection(MANUFACTURER_WEH, 0x07, 0xfe);
|
|
di.addDetection(MANUFACTURER_WEH, 0x07, 0x03);
|
|
|
|
di.setConstructor([](MeterInfo& mi, DriverInfo& di){ return shared_ptr<Meter>(new Driver(mi, di)); });
|
|
});
|
|
|
|
Driver::Driver(MeterInfo &mi, DriverInfo &di) : MeterCommonImplementation(mi, di)
|
|
{
|
|
addNumericFieldWithExtractor(
|
|
"total",
|
|
"The total water consumption recorded by this meter.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Volume,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::Volume)
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"target",
|
|
"The most recent billing period date.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::PointInTime,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::Date)
|
|
.set(StorageNr(1)),
|
|
Unit::DateLT
|
|
);
|
|
|
|
addNumericFieldWithExtractor(
|
|
"target",
|
|
"The total water consumption at the most recent billing period date.",
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
Quantity::Volume,
|
|
VifScaling::Auto,
|
|
FieldMatcher::build()
|
|
.set(MeasurementType::Instantaneous)
|
|
.set(VIFRange::Volume)
|
|
.set(StorageNr(1))
|
|
);
|
|
}
|
|
}
|
|
|
|
// Test: Vatten weh_07 86868686 NOKEY
|
|
// Comment: Techem radio convert + Wehrle water meter combo.
|
|
// telegram=|494468509494949495377286868686A85CFE07A90030052F2F_0413100000000F52FCF6A52A90A8D83CA8F7FEAE86990502323D0C70EFF49833C7C1696F75BCABC1E52E6305308D0F31FB|
|
|
// {"media":"water","meter":"weh_07","name":"Vatten","id":"86868686","total_m3":0.016,"timestamp":"1111-11-11T11:11:11Z"}
|
|
// |Vatten;86868686;0.016;1111-11-11 11:11.11
|
|
|
|
// Test: Vattenn weh_07 27604781 NOKEY
|
|
// Comment: A normal water meter.
|
|
// telegram=|5244A85C8147602703077A5B0840252F2F_0413B39100004413000000004D931E2C73FE0000000000000000000000000000000000000000000000000000000000000000000000009885001A0C002F2F426CBE29|
|
|
// {"id": "27604781","media": "water","meter": "weh_07","name": "Vattenn","target_date": "2021-09-30","target_m3": 0,"timestamp": "1111-11-11T11:11:11Z","total_m3": 37.299 }
|
|
// |Vattenn;27604781;37.299;1111-11-11 11:11.11
|