.TH BEAK 1
|
|
.SH NAME
|
|
wmbusmeters \- listen to wireless mbus radio traffic and relay the decoded telegrams to other software
|
|
|
|
.SH SYNOPSIS
|
|
.B wmbusmeters [options] <device> (<meter_name> <meter_type> <meter_id> meter_key>)*
|
|
|
|
.B wmbusmetersd <pid_file>
|
|
|
|
.SH DESCRIPTION
|
|
|
|
Wmbusmeters acquires wmbus telegrams, decodes them and relays them to
|
|
some other software for further processing. It can for example listen
|
|
to radio traffic using dedicated wmbus dongles like (im871a/amb8465)
|
|
or a generic software defined radio dongle (rtl_sdr).
|
|
|
|
After the received telegram has been decrypted and parsed, it can then
|
|
be relayed using a shell command, or stored in a log file. The shell
|
|
commands can for example relay the telegram using MQTT (eg
|
|
mqtt_publish) sent to a REST API (eg curl) or store it in a database
|
|
(eg psql).
|
|
|
|
.SH OPTIONS
|
|
\fB\--c1\fR listen to C1 messages when no meters are supplied
|
|
|
|
\fB\--debug\fR for a lot of information
|
|
|
|
\fB\--exitafter=\fR<time> exit program after time, eg 20h, 10m 5s
|
|
|
|
\fB\--format=\fR(hr|json|fields) for human readable, json or semicolon separated fields
|
|
|
|
\fB\--logfile=\fR<dir> use this file instead of stdout
|
|
|
|
\fB\--logtelegrams\fR log the contents of the telegrams for easy replay
|
|
|
|
\fB\--meterfiles=\fR<dir> store meter readings in dir
|
|
|
|
\fB\--meterfilesaction=\fR(overwrite|append) overwrite or append to the meter readings file
|
|
|
|
\fB\--oneshot\fR wait for an update from each meter, then quit
|
|
|
|
\fB\--separator=\fR<c> change field separator to c
|
|
|
|
\fB\--shell=\fR<cmdline> invokes cmdline with env variables containing the latest reading
|
|
|
|
\fB\--shellenvs\fR list the env variables available for the meter
|
|
|
|
\fB\--t1\fR listen to T1 messages when no meters are supplied
|
|
|
|
\fB\--useconfig=\fR<dir> load config files from dir/etc
|
|
|
|
\fB\--verbose\fR for more information
|
|
|
|
.SH DEVICES
|
|
.TP
|
|
\fB/dev/ttyUSB0\fR to which an im871a or amb8456 dongle is attached
|
|
|
|
.TP
|
|
\fBauto\fR look for /dev/im871a or /dev/amb8465 or /dev/rtlsdr (these will only show up automatically if the appropriate udev rules have been installed)
|
|
|
|
.TP
|
|
\fBrtlwmbus\fR use software defined radio rtl_sdr|rtl_wmbus to receive wmbus telegrams.This defaults to 868.95MHz, use for example \fBrtlwmbus:868.9M\fR to tune the rtl_sdr dongle to slightly lower frequency.
|
|
|
|
.TP
|
|
\fBsimulation_xxx.txt\fR read telegrams from file to replay telegram feed (use --logtelegrams to acquire feed for replay)
|
|
|
|
.SH METER QUADRUPLES
|
|
.TP
|
|
\fBmeter_name\fR a mnemonic for your utility meter
|
|
.TP
|
|
\fBmeter_type\fR multical21/flowiq3100/supercom587/iperl/multical302/omnipower/qcaloric/apator162/amiplus
|
|
.TP
|
|
\fBmeter_id\fR one or more 8 digit numbers separated with commas, or a single '*' wildcard.
|
|
.TP
|
|
\fBmeter_key\fR a unique key for the meter, if meter telegrams are not encrypted, you must supply an empty key: ""
|
|
|
|
.SH EXAMPLES
|
|
.TP
|
|
|
|
Listen to T1 traffic using a wmbus dongle attached to ttyUSB0.
|
|
|
|
% wmbusmeters --t1 /dev/ttyUSB0
|
|
|
|
.TP
|
|
Listen to C1 traffic and assume that a wmbus dongle is either /dev/im871a or /dev/amb8465 or /dev/rtlsdr
|
|
|
|
% wmbusmeters --c1 auto
|
|
|
|
.TP
|
|
Listen to both T1 and C1 traffic using rtl_sdr|rtl_wmbus and the standard frequency 868.95M, which
|
|
might need tweaking depending on the rtl_sdr dongle you are using.
|
|
|
|
% wmbusmeters rtlwmbus:868.95M
|
|
|
|
.TP
|
|
Execute using config file /home/me/etc/wmbusmeters.conf and meter config files in /home/me/etc/wmbusmeters.d
|
|
|
|
% wmbusmeters --useconfig=/home/me
|
|
|
|
.TP
|
|
Start a daemon using config file /etc/wmbusmeters.conf and meter config files in /etc/wmbusmeters.d
|
|
|
|
% wmbusmetersd --useconfig=/ /var/run/wmbusmeters/wmbusmeters.pid
|
|
|
|
.TP
|
|
An example wmbusmeters.conf:
|
|
|
|
.nf
|
|
loglevel=normal
|
|
device=auto
|
|
logtelegrams=false
|
|
meterfiles=/var/log/wmbusmeters/meter_readings
|
|
meterfilesaction=overwrite
|
|
logfile=/var/log/wmbusmeters/wmbusmeters.log
|
|
shell=/usr/bin/mosquitto_pub -h localhost -t "wmbusmeters/$METER_ID" -m "$METER_JSON"
|
|
.fi
|
|
|
|
.TP
|
|
An example wmbusmeters.d file:
|
|
|
|
.nf
|
|
name=MyTapWater
|
|
type=multical21
|
|
id=12345678
|
|
key=001122334455667788AABBCCDDEEFF
|
|
|
|
.SH AUTHOR
|
|
Written by Fredrik Öhrström.
|
|
|
|
.SH COPYRIGHT
|
|
Copyright \(co 2017-2019 Fredrik Öhrström.
|
|
.br
|
|
License GPLv3+: GNU GPL version 3 or later <http://gnu.org/licenses/gpl.html>.
|
|
.br
|
|
This is free software: you are free to change and redistribute it.
|
|
.br
|
|