#include"dvparser.h"
#include"meters.h"
#include"meters_common_implementation.h"
#include"wmbus.h"
#include"wmbus_utils.h"
using namespace std;
struct MeterHydrus : public virtual WaterMeter, public virtual MeterCommonImplementation {
MeterHydrus(MeterInfo &mi);
// Total water counted through the meter
double totalWaterConsumption(Unit u);
double totalWaterConsumptionAtDate(Unit u);
bool hasTotalWaterConsumption();
double maxFlow(Unit u);
bool hasMaxFlow();
double flowTemperature(Unit u);
private:
void processContent(Telegram *t);
double total_water_consumption_m3_ {};
double total_water_consumption_at_date_m3_ {};
string at_date_;
double max_flow_m3h_ {};
double flow_temperature_c_ { 127 };
double remaining_battery_life_year_;
string status_; // TPL STS
map<int,string> error_codes_;
};
MeterHydrus::MeterHydrus(MeterInfo &mi) :
MeterCommonImplementation(mi, MeterType::HYDRUS)
{
setExpectedTPLSecurityMode(TPLSecurityMode::AES_CBC_IV);
addLinkMode(LinkMode::T1);
error_codes_ = { { 0x10, "TEMPERATURE_MEASUREMENT_ERROR" },
{ 0x30, "AIR_IN_PIPE" },
{ 0x70, "MEASUREMENT_ERROR" },
{ 0x90, "LEAKAGE_OR_NO_USAGE" },
{ 0xb0, "REVERSE_FLOW" },
{ 0xd0, "LOW_TEMPERATURE" },
{ 0xf0, "AIR_IN_PIPE" } };
addPrint("total", Quantity::Volume,
[&](Unit u){ return totalWaterConsumption(u); },
"The total water consumption recorded by this meter.",
true, true);
addPrint("max_flow", Quantity::Flow,
[&](Unit u){ return maxFlow(u); },
"The maxium flow recorded during previous period.",
true, true);
addPrint("flow_temperature", Quantity::Temperature,
[&](Unit u){ return flowTemperature(u); },
"The water temperature.",
false, true);
addPrint("total_at_date", Quantity::Volume,
[&](Unit u){ return totalWaterConsumptionAtDate(u); },
"The total water consumption recorded at date.",
false, true);
addPrint("at_date", Quantity::Text,
[&](){ return at_date_; },
"Date when total water consumption was recorded.",
false, true);
addPrint("remaining_battery_life", Quantity::Time, Unit::Year,
[&](Unit u){ return convert(remaining_battery_life_year_, Unit::Year, u); },
"How many more years the battery is expected to last",
false, true);
addPrint("status", Quantity::Text,
[&](){ return status_; },
"The status is OK or some error condition.",
true, true);
}
shared_ptr<WaterMeter> createHydrus(MeterInfo &mi)
{
return shared_ptr<WaterMeter>(new MeterHydrus(mi));
}
void MeterHydrus::processContent(Telegram *t)
{
// There are two distinctintly different Hydrus telegrams.
// Unfortunately there seems to be no markings on the
// physical meter that tells us which version it is.
//
// Fortunately the mfct,media,version bits does distinguish
// the meters!
//
// This driver currently only decodes parts of both telegrams.
// Eventually we should either split this driver into two.
// Or make more generic capabilities in drivers to switch
// between different telegrams formats, that are similar
// but not quite.
/*
New style telegram:
(hydrus) 11: 0C dif (8 digit BCD Instantaneous value)
(hydrus) 12: 13 vif (Volume l)
(hydrus) 13: * 50340000 total consumption (3.450000 m3)
(hydrus) 17: 0D dif (variable length Instantaneous value)
(hydrus) 18: FD vif (Second extension of VIF-codes)
(hydrus) 19: 11 vife (Customer)
(hydrus) 1a: 0A varlen=10
(hydrus) 1b: 38373130313442303241
(hydrus) 25: 0B dif (6 digit BCD Instantaneous value)
(hydrus) 26: 3B vif (Volume flow l/h)
(hydrus) 27: * 000000 max flow (0.000000 m3/h)
(hydrus) 2a: 02 dif (16 Bit Integer/Binary Instantaneous value)
(hydrus) 2b: FD vif (Second extension of VIF-codes)
(hydrus) 2c: 74 vife (Reserved)
(hydrus) 2d: * DC15 battery life days (5596)
(hydrus) 2f: C4 dif (32 Bit Integer/Binary Instantaneous value storagenr=1)
(hydrus) 30: 01 dife (subunit=0 tariff=0 storagenr=3)
(hydrus) 31: 6D vif (Date and time type)
(hydrus) 32: * 3B178D29 at date (2020-09-13 23:59)
(hydrus) 36: CC dif (8 digit BCD Instantaneous value storagenr=1)
(hydrus) 37: 01 dife (subunit=0 tariff=0 storagenr=3)
(hydrus) 38: 13 vif (Volume l)
(hydrus) 39: * 31340000 total consumption at date (3.431000 m3)
(hydrus) 3d: 2F skip
(hydrus) 3e: 2F skip
{"media":"warm water","meter":"hydrus","name":"Vatten","id":"65656565","total_m3":3.45,"max_flow_m3h":0,"flow_temperature_c":127,"total_at_date_m3":3.431,"at_date":"2020-09-13 23:59","battery_life_days":"5596","status":"OK","timestamp":"2020-09-27T08:54:42Z"}
Old style telegram
(hydrus) 11: 01 dif (8 Bit Integer/Binary Instantaneous value)
(hydrus) 12: FD vif (Second extension of VIF-codes)
(hydrus) 13: 08 vife (Access Number (transmission count))
(hydrus) 14: 30
(hydrus) 15: 0C dif (8 digit BCD Instantaneous value)
(hydrus) 16: 13 vif (Volume l)
(hydrus) 17: * 74110000 total consumption (1.174000 m3)
(hydrus) 1b: 7C dif (8 digit BCD Value during error state storagenr=1)
(hydrus) 1c: 13 vif (Volume l)
(hydrus) 1d: 00000000
(hydrus) 21: FC dif (8 digit BCD Value during error state storagenr=1)
(hydrus) 22: 10 dife (subunit=0 tariff=1 storagenr=1)
(hydrus) 23: 13 vif (Volume l)
(hydrus) 24: 00000000
(hydrus) 28: FC dif (8 digit BCD Value during error state storagenr=1)
(hydrus) 29: 20 dife (subunit=0 tariff=2 storagenr=1)
(hydrus) 2a: 13 vif (Volume l)
(hydrus) 2b: 00000000
(hydrus) 2f: 72 dif (16 Bit Integer/Binary Value during error state storagenr=1)
(hydrus) 30: 6C vif (Date type G)
(hydrus) 31: 0000
(hydrus) 33: 0B dif (6 digit BCD Instantaneous value)
(hydrus) 34: 3B vif (Volume flow l/h)
(hydrus) 35: * 000000 max flow (0.000000 m3/h)
(hydrus) 38: 02 dif (16 Bit Integer/Binary Instantaneous value)
(hydrus) 39: FD vif (Second extension of VIF-codes)
(hydrus) 3a: 74 vife (Reserved)
(hydrus) 3b: * 8713 battery life days (4999)
(hydrus) 3d: 02 dif (16 Bit Integer/Binary Instantaneous value)
(hydrus) 3e: 5A vif (Flow temperature 10⁻¹ °C)
(hydrus) 3f: * 6800 flow temperature (10.400000 °C)
(hydrus) 41: C4 dif (32 Bit Integer/Binary Instantaneous value storagenr=1)
(hydrus) 42: 01 dife (subunit=0 tariff=0 storagenr=3)
(hydrus) 43: 6D vif (Date and time type)
(hydrus) 44: * 3B177F2A at date (2019-10-31 23:59)
(hydrus) 48: CC dif (8 digit BCD Instantaneous value storagenr=1)
(hydrus) 49: 01 dife (subunit=0 tariff=0 storagenr=3)
(hydrus) 4a: 13 vif (Volume l)
(hydrus) 4b: * 00020000 total consumption at date (0.200000 m3)
{"media":"water","meter":"hydrus","name":"Votten","id":"64646464","total_m3":1.174,"max_flow_m3h":0,"flow_temperature_c":10.4,"total_at_date_m3":0.2,"at_date":"2019-10-31 23:59","battery_life_days":"4999","status":"OK","timestamp":"2020-09-27T08:54:42Z"}
*/
int offset;
string key;
if (findKey(MeasurementType::Unknown, ValueInformation::Volume, 0, 0, &key, &t->values)) {
extractDVdouble(&t->values, key, &offset, &total_water_consumption_m3_);
t->addMoreExplanation(offset, " total consumption (%f m3)", total_water_consumption_m3_);
}
if (findKey(MeasurementType::Unknown, ValueInformation::VolumeFlow, 0, 0, &key, &t->values)) {
extractDVdouble(&t->values, key, &offset, &max_flow_m3h_);
t->addMoreExplanation(offset, " max flow (%f m3/h)", max_flow_m3h_);
}
if (findKey(MeasurementType::Unknown, ValueInformation::FlowTemperature, 0, 0, &key, &t->values)) {
extractDVdouble(&t->values, key, &offset, &flow_temperature_c_);
t->addMoreExplanation(offset, " flow temperature (%f °C)", flow_temperature_c_);
}
if (findKey(MeasurementType::Unknown, ValueInformation::Volume, 3, 0, &key, &t->values)) {
extractDVdouble(&t->values, key, &offset, &total_water_consumption_at_date_m3_);
t->addMoreExplanation(offset, " total consumption at date (%f m3)", total_water_consumption_at_date_m3_);
}
if (findKey(MeasurementType::Unknown, ValueInformation::DateTime, 3, 0, &key, &t->values)) {
struct tm datetime;
extractDVdate(&t->values, key, &offset, &datetime);
at_date_ = strdatetime(&datetime);
t->addMoreExplanation(offset, " at date (%s)", at_date_.c_str());
}
uint16_t days {};
extractDVuint16(&t->values, "02FD74", &offset, &days);
remaining_battery_life_year_ = ((double)days) / 365.25;
t->addMoreExplanation(offset, " battery life (%d days %f years)", days, remaining_battery_life_year_);
status_ = decodeTPLStatusByte(t->tpl_sts, error_codes_);
}
double MeterHydrus::totalWaterConsumption(Unit u)
{
assertQuantity(u, Quantity::Volume);
return convert(total_water_consumption_m3_, Unit::M3, u);
}
double MeterHydrus::totalWaterConsumptionAtDate(Unit u)
{
assertQuantity(u, Quantity::Volume);
return convert(total_water_consumption_at_date_m3_, Unit::M3, u);
}
bool MeterHydrus::hasTotalWaterConsumption()
{
return true;
}
double MeterHydrus::maxFlow(Unit u)
{
assertQuantity(u, Quantity::Flow);
return convert(max_flow_m3h_, Unit::M3H, u);
}
bool MeterHydrus::hasMaxFlow()
{
return true;
}
double MeterHydrus::flowTemperature(Unit u)
{
assertQuantity(u, Quantity::Temperature);
return convert(flow_temperature_c_, Unit::C, u);
}