#!/bin/sh
|
|
|
|
PROG="$1"
|
|
|
|
if [ "$PROG" = "" ]
|
|
then
|
|
echo Please supply the binary to be tested as the first argument.
|
|
exit 1
|
|
fi
|
|
|
|
TEST=testoutput
|
|
LOGFILE=$TEST/logfile
|
|
LOGFILE_EXPECTED=$TEST/logfile.expected
|
|
|
|
TESTNAME="Test listen and print any meter heard in logfile"
|
|
TESTRESULT="ERROR"
|
|
|
|
mkdir -p $TEST
|
|
rm -f $LOGFILE
|
|
|
|
cat > $LOGFILE_EXPECTED <<EOF
|
|
No meters configured. Printing id:s of all telegrams heard!
|
|
Received telegram from: 12345678
|
|
manufacturer: (SON) Sontex, Switzerland (0x4dee)
|
|
type: Warm Water (30°C-90°C) meter (0x06)
|
|
ver: 0x3c
|
|
driver: supercom587
|
|
Received telegram from: 11111111
|
|
manufacturer: (SON) Sontex, Switzerland (0x4dee)
|
|
type: Water meter (0x07)
|
|
ver: 0x3c
|
|
driver: supercom587
|
|
Received telegram from: 27282728
|
|
manufacturer: (SON) Sontex, Switzerland (0x4dee)
|
|
type: Heat Cost Allocator (0x08)
|
|
ver: 0x16
|
|
driver: sontex868
|
|
Received telegram from: 12345699
|
|
manufacturer: (SEN) Sensus Metering Systems, Germany (0x4cae)
|
|
type: Water meter (0x07)
|
|
ver: 0x68
|
|
driver: iperl
|
|
Received telegram from: 33225544
|
|
manufacturer: (SEN) Sensus Metering Systems, Germany (0x4cae)
|
|
type: Water meter (0x07)
|
|
ver: 0x68
|
|
driver: iperl
|
|
Received telegram from: 10101010
|
|
manufacturer: (APA) Apator, Poland (0x601)
|
|
type: Electricity meter (0x02)
|
|
ver: 0x02
|
|
driver: amiplus
|
|
Received telegram from: 00254358
|
|
manufacturer: (DEV) Develco Products, Denmark (0x10b6)
|
|
type: Electricity meter (0x02)
|
|
ver: 0x00
|
|
driver: amiplus
|
|
Received telegram from: 34333231
|
|
manufacturer: (TCH) Techem Service (0x5068)
|
|
type: Warm water (0x62)
|
|
ver: 0x74
|
|
driver: mkradio3
|
|
Received telegram from: 02410120
|
|
manufacturer: (TCH) Techem Service (0x5068)
|
|
type: Warm water (0x62)
|
|
ver: 0x95
|
|
driver: mkradio4
|
|
Received telegram from: 58234965
|
|
manufacturer: (TCH) Techem Service (0x5068)
|
|
type: Heat meter (0xc3)
|
|
ver: 0x27
|
|
driver: vario451
|
|
Received telegram from: 11776622
|
|
manufacturer: (TCH) Techem Service (0x5068)
|
|
type: Heat Cost Allocator (0x80)
|
|
ver: 0x69
|
|
driver: fhkvdataiii
|
|
Received telegram from: 11111234
|
|
manufacturer: (TCH) Techem Service (0x5068)
|
|
type: Heat Cost Allocator (0x80)
|
|
ver: 0x94
|
|
driver: fhkvdataiii
|
|
Received telegram from: 14542076
|
|
manufacturer: (TCH) Techem Service (0x5068)
|
|
type: Heat Cost Allocator (0x08)
|
|
ver: 0x94
|
|
driver: fhkvdataiv
|
|
Received telegram from: 88018801
|
|
manufacturer: (INE) INNOTAS Elektronik, Germany (0x25c5)
|
|
type: Heat Cost Allocator (0x08)
|
|
ver: 0x55
|
|
Concerning meter: 88018801
|
|
manufacturer: (INE) INNOTAS Elektronik, Germany (0x25c5)
|
|
type: Heat Cost Allocator (0x08)
|
|
ver: 0x55
|
|
driver: eurisii eurisii
|
|
Received telegram from: 00010204
|
|
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
|
|
type: Smoke detector (0x1a)
|
|
ver: 0x03
|
|
driver: lansensm
|
|
Received telegram from: 00010204
|
|
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
|
|
type: Smoke detector (0x1a)
|
|
ver: 0x03
|
|
driver: lansensm
|
|
Received telegram from: 00010203
|
|
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
|
|
type: Room sensor (eg temperature or humidity) (0x1b)
|
|
ver: 0x07
|
|
driver: lansenth
|
|
Received telegram from: 00010205
|
|
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
|
|
type: Reserved for sensors (0x1d)
|
|
ver: 0x07
|
|
driver: lansendw
|
|
Received telegram from: 00010205
|
|
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
|
|
type: Reserved for sensors (0x1d)
|
|
ver: 0x07
|
|
driver: lansendw
|
|
Received telegram from: 00010206
|
|
manufacturer: (LAS) Lansen Systems, Sweden (0x3033)
|
|
type: Other (0x00)
|
|
ver: 0x14
|
|
driver: lansenpu
|
|
Received telegram from: 11772288
|
|
manufacturer: (BMT) BMETERS, Italy (0x9b4)
|
|
type: Room sensor (eg temperature or humidity) (0x1b)
|
|
ver: 0x10
|
|
driver: rfmamb
|
|
Received telegram from: 64646464
|
|
manufacturer: (DME) DIEHL Metering, Germany (0x11a5)
|
|
type: Water meter (0x07)
|
|
ver: 0x70
|
|
driver: hydrus
|
|
Received telegram from: 65656565
|
|
manufacturer: (DME) DIEHL Metering, Germany (0x11a5)
|
|
type: Warm Water (30°C-90°C) meter (0x06)
|
|
ver: 0x70
|
|
driver: hydrus
|
|
Received telegram from: 81100028
|
|
manufacturer: (HYD) Hydrometer (0x2324)
|
|
type: Bus/System component (0x0e)
|
|
ver: 0x64
|
|
Concerning meter: 64745666
|
|
manufacturer: (DME) DIEHL Metering, Germany (0x11a5)
|
|
type: Water meter (0x07)
|
|
ver: 0x70
|
|
driver: hydrus
|
|
Received telegram from: 86868686
|
|
manufacturer: (BMT) BMETERS, Italy (0x9b4)
|
|
type: Water meter (0x07)
|
|
ver: 0x13
|
|
driver: hydrodigit
|
|
Received telegram from: 67452301
|
|
manufacturer: (BMT) BMETERS, Italy (0x9b4)
|
|
type: Warm Water (30°C-90°C) meter (0x06)
|
|
ver: 0x13
|
|
driver: hydrodigit
|
|
Received telegram from: 72727272
|
|
manufacturer: (AXI) UAB Axis Industries, Lithuania (0x709)
|
|
type: Water meter (0x07)
|
|
ver: 0x10
|
|
driver: q400
|
|
Received telegram from: 72727273
|
|
manufacturer: (AXI) UAB Axis Industries, Lithuania (0x709)
|
|
type: Water meter (0x07)
|
|
ver: 0x10
|
|
driver: q400
|
|
Received telegram from: 22992299
|
|
manufacturer: (EBZ) eBZ, Germany (0x145a)
|
|
type: Radio converter (meter side) (0x37)
|
|
ver: 0x02
|
|
Concerning meter: 22992299
|
|
manufacturer: (EBZ) eBZ, Germany (0x145a)
|
|
type: Electricity meter (0x02)
|
|
ver: 0x01
|
|
driver: ebzwmbe
|
|
Received telegram from: 77997799
|
|
manufacturer: (ESY) EasyMeter (0x1679)
|
|
type: Radio converter (meter side) (0x37)
|
|
ver: 0x30
|
|
Concerning meter: 77997799
|
|
manufacturer: (ETY) Unknown (0x1699)
|
|
type: Electricity meter (0x02)
|
|
ver: 0x11
|
|
driver: esyswm
|
|
Received telegram from: 77997799
|
|
manufacturer: (ESY) EasyMeter (0x1679)
|
|
type: Radio converter (meter side) (0x37)
|
|
ver: 0x30
|
|
Concerning meter: 77997799
|
|
manufacturer: (ESY) EasyMeter (0x1679)
|
|
type: Electricity meter (0x02)
|
|
ver: 0x11
|
|
driver: esyswm
|
|
Received telegram from: 55995599
|
|
manufacturer: (EMH) EMH metering formerly EMH Elektrizitatszahler (0x15a8)
|
|
type: Electricity meter (0x02)
|
|
ver: 0x02
|
|
driver: ehzp
|
|
Received telegram from: 004444dd
|
|
manufacturer: (APT) Unknown (0x8614)
|
|
type: Gas meter (0x03)
|
|
ver: 0x03
|
|
driver: apator08
|
|
Received telegram from: 74737271
|
|
manufacturer: (BMT) BMETERS, Italy (0x9b4)
|
|
type: Water meter (0x07)
|
|
ver: 0x05
|
|
driver: rfmtx1
|
|
Received telegram from: 20096221
|
|
manufacturer: (DWZ) Lorenz, Germany (0x12fa)
|
|
type: Warm Water (30°C-90°C) meter (0x06)
|
|
ver: 0x02
|
|
driver: waterstarm
|
|
Received telegram from: 78563412
|
|
manufacturer: (AMT) INTEGRA METERING (0x5b4)
|
|
type: Water meter (0x07)
|
|
ver: 0xf1
|
|
driver: topaseskr
|
|
Received telegram from: 95969798
|
|
manufacturer: (APA) Apator, Poland (0x601)
|
|
type: Cold water meter (0x16)
|
|
ver: 0x01
|
|
driver: ultrimis
|
|
Received telegram from: 12345679
|
|
manufacturer: (EFE) Engelmann Sensor, Germany (0x14c5)
|
|
type: Heat meter (0x04)
|
|
ver: 0x00
|
|
driver: sensostar
|
|
Received telegram from: 99993030
|
|
manufacturer: (ELR) Elster Metering, United Kingdom (0x1592)
|
|
type: Water meter (0x07)
|
|
ver: 0x0d
|
|
driver: ev200
|
|
Received telegram from: 95949392
|
|
manufacturer: (ELR) Elster Metering, United Kingdom (0x1592)
|
|
type: Radio converter (meter side) (0x37)
|
|
ver: 0x11
|
|
driver: emerlin868
|
|
Received telegram from: 91633569
|
|
manufacturer: (TCH) Techem Service (0x5068)
|
|
type: Smoke detector (0xf0)
|
|
ver: 0x76
|
|
driver: tsd2
|
|
Received telegram from: 62626262
|
|
manufacturer: (TCH) Techem Service (0x5068)
|
|
type: Heat meter (0x43)
|
|
ver: 0x45
|
|
driver: compact5
|
|
Received telegram from: 79787776
|
|
manufacturer: (MAD) Maddalena, Italy (0x3424)
|
|
type: Water meter (0x07)
|
|
ver: 0x50
|
|
driver: evo868
|
|
Received telegram from: 18046178
|
|
manufacturer: (GSS) R D Gran System S, Belarus (0x1e73)
|
|
type: Electricity meter (0x02)
|
|
ver: 0x01
|
|
driver: gransystems
|
|
Received telegram from: 20100117
|
|
manufacturer: (GSS) R D Gran System S, Belarus (0x1e73)
|
|
type: Electricity meter (0x02)
|
|
ver: 0x01
|
|
driver: gransystems
|
|
Received telegram from: 68926025
|
|
manufacturer: (HYD) Hydrometer (0x2324)
|
|
type: Heat meter (0x04)
|
|
ver: 0x20
|
|
driver: sharky
|
|
Received telegram from: 00050901
|
|
manufacturer: (APA) Unknown (0x8601)
|
|
type: Radio converter (meter side) (0x37)
|
|
ver: 0x18
|
|
Concerning meter: 01885619
|
|
manufacturer: (APA) Apator, Poland (0x601)
|
|
type: Heat meter (0x04)
|
|
ver: 0x40
|
|
driver: elf
|
|
Received telegram from: 93929190
|
|
manufacturer: (DME) DIEHL Metering, Germany (0x11a5)
|
|
type: Water meter (0x07)
|
|
ver: 0x7b
|
|
driver: dme_07
|
|
Received telegram from: 60897379
|
|
manufacturer: (HYD) Hydrometer (0x2324)
|
|
type: Water meter (0x07)
|
|
ver: 0x8b
|
|
driver: hydrus
|
|
Received telegram from: 60904720
|
|
manufacturer: (HYD) Hydrometer (0x2324)
|
|
type: Warm Water (30°C-90°C) meter (0x06)
|
|
ver: 0x8b
|
|
driver: hydrus
|
|
Received telegram from: 18001698
|
|
manufacturer: (HYD) Hydrometer (0x2324)
|
|
type: Water meter (0x07)
|
|
ver: 0x85
|
|
driver: izar
|
|
Received telegram from: 61070071
|
|
manufacturer: (AAA) Aventies, Germany (0x421)
|
|
type: Water meter (0x07)
|
|
ver: 0x25
|
|
Concerning meter: 61070071
|
|
manufacturer: (AAA) Aventies, Germany (0x421)
|
|
type: Water meter (0x07)
|
|
ver: 0x25
|
|
driver: aventieswm aventieswm
|
|
Received telegram from: 00043094
|
|
manufacturer: (AMX) APATOR METRIX, Poland (0x5b8)
|
|
type: Gas meter (0x03)
|
|
ver: 0x01
|
|
driver: unismart
|
|
Received telegram from: 71727374
|
|
manufacturer: (BMT) BMETERS, Italy (0x9b4)
|
|
type: Heat/Cooling load meter (0x0d)
|
|
ver: 0x0b
|
|
driver: hydrocalm3
|
|
Received telegram from: 00013482
|
|
manufacturer: (WEP) Weptech elektronik, Germany (0x5cb0)
|
|
type: Room sensor (eg temperature or humidity) (0x1b)
|
|
ver: 0x02
|
|
driver: munia
|
|
Received telegram from: 37027095
|
|
manufacturer: (QDS) Qundis, Germany (0x4493)
|
|
type: Radio converter (meter side) (0x37)
|
|
ver: 0x23
|
|
Concerning meter: 67228058
|
|
manufacturer: (QDS) Qundis, Germany (0x4493)
|
|
type: Heat meter (0x04)
|
|
ver: 0x23
|
|
driver: qheat
|
|
Received telegram from: 45797086
|
|
manufacturer: (QDS) Qundis, Germany (0x4493)
|
|
type: Smoke detector (0x1a)
|
|
ver: 0x21
|
|
driver: qsmoke
|
|
EOF
|
|
|
|
RES=$($PROG --logfile=$LOGFILE --t1 simulations/simulation_t1.txt 2>&1)
|
|
|
|
if [ ! "$RES" = "" ]
|
|
then
|
|
echo ERROR: $TESTNAME
|
|
echo Expected no output on stdout and stderr
|
|
echo but got------------------
|
|
echo $RES
|
|
echo ---------------------
|
|
exit 1
|
|
fi
|
|
|
|
RES=$(diff $LOGFILE $LOGFILE_EXPECTED)
|
|
|
|
if [ ! -z "$RES" ]
|
|
then
|
|
echo ERROR: $TESTNAME
|
|
echo -----------------
|
|
diff $LOGFILE $LOGFILE_EXPECTED
|
|
echo -----------------
|
|
exit 1
|
|
else
|
|
echo OK: $TESTNAME
|
|
fi
|
|
|
|
TESTNAME="Test listen and print any meter heard on stdout"
|
|
TESTRESULT="ERROR"
|
|
|
|
$PROG --t1 simulations/simulation_t1.txt 2> $LOGFILE
|
|
|
|
RES=$(diff $LOGFILE $LOGFILE_EXPECTED)
|
|
|
|
if [ ! -z "$RES" ]
|
|
then
|
|
echo ERROR: $TESTNAME
|
|
echo -----------------
|
|
diff $LOGFILE $LOGFILE_EXPECTED
|
|
echo -----------------
|
|
exit 1
|
|
else
|
|
echo OK: $TESTNAME
|
|
fi
|