kopia lustrzana https://github.com/weetmuts/wmbusmeters
120 wiersze
5.0 KiB
C++
120 wiersze
5.0 KiB
C++
/*
|
|
Copyright (C) 2020-2022 Fredrik Öhrström (gpl-3.0-or-later)
|
|
|
|
This program is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
|
|
#include"meters_common_implementation.h"
|
|
|
|
namespace
|
|
{
|
|
struct Driver : public virtual MeterCommonImplementation
|
|
{
|
|
Driver(MeterInfo &mi, DriverInfo &di);
|
|
|
|
void processContent(Telegram *t);
|
|
};
|
|
|
|
static bool ok = registerDriver([](DriverInfo&di)
|
|
{
|
|
di.setName("compact5");
|
|
di.setDefaultFields("name,id,total_kwh,current_kwh,previous_kwh,timestamp");
|
|
di.setMeterType(MeterType::WaterMeter);
|
|
di.addLinkMode(LinkMode::T1);
|
|
di.addLinkMode(LinkMode::C1);
|
|
di.addDetection(MANUFACTURER_TCH, 0x04, 0x45);
|
|
di.addDetection(MANUFACTURER_TCH, 0xc3, 0x45);
|
|
di.addDetection(MANUFACTURER_TCH, 0x43, 0x22);
|
|
di.addDetection(MANUFACTURER_TCH, 0x43, 0x45);
|
|
di.addDetection(MANUFACTURER_TCH, 0x43, 0x39);
|
|
di.usesProcessContent();
|
|
di.setConstructor([](MeterInfo& mi, DriverInfo& di){ return shared_ptr<Meter>(new Driver(mi, di)); });
|
|
});
|
|
|
|
Driver::Driver(MeterInfo &mi, DriverInfo &di) : MeterCommonImplementation(mi, di)
|
|
{
|
|
addNumericField("total",
|
|
Quantity::Energy,
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
"The total energy consumption recorded by this meter.");
|
|
|
|
addNumericField("current",
|
|
Quantity::Energy,
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
"Energy consumption so far in this billing period.");
|
|
|
|
addNumericField("previous",
|
|
Quantity::Energy,
|
|
DEFAULT_PRINT_PROPERTIES,
|
|
"Energy consumption in previous billing period.");
|
|
}
|
|
|
|
void Driver::processContent(Telegram *t)
|
|
{
|
|
// Unfortunately, the Techem Compact V is mostly a proprieatary protocol
|
|
// simple wrapped inside a wmbus telegram since the ci-field is 0xa2.
|
|
// Which means that the entire payload is manufacturer specific.
|
|
|
|
map<string,pair<int,DVEntry>> vendor_values;
|
|
vector<uchar> content;
|
|
|
|
t->extractPayload(&content);
|
|
|
|
if (content.size() < 9) return;
|
|
|
|
uchar prev_lo = content[3];
|
|
uchar prev_hi = content[4];
|
|
double prev = (256.0*prev_hi+prev_lo);
|
|
|
|
string prevs;
|
|
strprintf(&prevs, "%02x%02x", prev_lo, prev_hi);
|
|
int offset = t->parsed.size()+3;
|
|
vendor_values["0215"] = { offset, DVEntry(offset, DifVifKey("0215"), MeasurementType::Instantaneous, 0x15, {}, {}, 0, 0, 0, prevs) };
|
|
Explanation pe(offset, 2, prevs, KindOfData::CONTENT, Understanding::FULL);
|
|
t->explanations.push_back(pe);
|
|
t->addMoreExplanation(offset, " energy used in previous billing period (%f KWH)", prev);
|
|
|
|
uchar curr_lo = content[7];
|
|
uchar curr_hi = content[8];
|
|
double curr = (256.0*curr_hi+curr_lo);
|
|
|
|
string currs;
|
|
strprintf(&currs, "%02x%02x", curr_lo, curr_hi);
|
|
offset = t->parsed.size()+7;
|
|
vendor_values["0215"] = { offset, DVEntry(offset, DifVifKey("0215"), MeasurementType::Instantaneous, 0x15, {}, {}, 0, 0, 0, currs) };
|
|
Explanation ce(offset, 2, currs, KindOfData::CONTENT, Understanding::FULL);
|
|
t->explanations.push_back(ce);
|
|
t->addMoreExplanation(offset, " energy used in current billing period (%f KWH)", curr);
|
|
|
|
double total_energy_kwh = prev+curr;
|
|
setNumericValue("total", Unit::KWH, total_energy_kwh);
|
|
|
|
double curr_energy_kwh = curr;
|
|
setNumericValue("current", Unit::KWH, curr_energy_kwh);
|
|
|
|
double prev_energy_kwh = prev;
|
|
setNumericValue("previous", Unit::KWH, prev_energy_kwh);
|
|
}
|
|
}
|
|
|
|
// Test: Heating compact5 62626262 NOKEY
|
|
// telegram=|36446850626262624543A1_009F2777010060780000000A000000000000000000000000000000000000000000000000A0400000B4010000|
|
|
// {"media":"heat","meter":"compact5","name":"Heating","id":"62626262","total_kwh":495,"current_kwh":120,"previous_kwh":375,"timestamp":"1111-11-11T11:11:11Z"}
|
|
// |Heating;62626262;495;120;375;1111-11-11 11:11.11
|
|
|
|
// Test: Heating2 compact5 66336633 NOKEY
|
|
// telegram=|37446850336633663943a2_10672c866100181c01000480794435d50000000000000000000000000000000000000000000000000000000000|
|
|
// {"media":"heat","meter":"compact5","name":"Heating2","id":"66336633","total_kwh":25250,"current_kwh":284,"previous_kwh":24966,"timestamp":"1111-11-11T11:11:11Z"}
|
|
// |Heating2;66336633;25250;284;24966;1111-11-11 11:11.11
|